0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
APTM20AM06S

APTM20AM06S

  • 厂商:

    ADPOW

  • 封装:

  • 描述:

    APTM20AM06S - Phase leg Series & parallel diodes MOSFET Power Module - Advanced Power Technology

  • 数据手册
  • 价格&库存
APTM20AM06S 数据手册
APTM20AM06S Phase leg Series & parallel diodes MOSFET Power Module VDSS = 200V RDSon = 6mW max @ Tj = 25°C ID = 300A @ Tc = 25°C Application · Motor control · Switched Mode Power Supplies · Uninterruptible Power Supplies Features · Power MOS 7® MOSFETs - Low RDSon - Low input and Miller capacitance - Low gate charge - Fast intrinsic reverse diode - Avalanche energy rated - Very rugged Kelvin source for easy drive Very low stray inductance - Symmetrical design - M5 power connectors High level of integration · · · Benefits · · · · G1 S1 VBUS 0/VBUS O UT S2 G2 Outstanding performance at high frequency operation Direct mounting to heatsink (isolated package) Low junction to case thermal resistance Low profile Absolute maximum ratings Symbol VDSS ID IDM VGS RDSon PD IAR EAR EAS Parameter Drain - Source Breakdown Voltage Continuous Drain Current Pulsed Drain current Gate - Source Voltage Drain - Source ON Resistance Maximum Power Dissipation Avalanche current (repetitive and non repetitive) Repetitive Avalanche Energy Single Pulse Avalanche Energy Tc = 25°C Tc = 80°C Max ratings 200 300 225 1200 ±30 6 1250 24 30 1300 Unit V A V mW W A mJ These Devices are sensitive to Electrostatic Discharge. Proper Handing Procedures Should Be Followed. APT website – http://www.advancedpower.com 1-6 APTM20AM06S – Rev 1 May, 2004 Tc = 25°C APTM20AM06S All ratings @ Tj = 25°C unless otherwise specified Electrical Characteristics Symbol Characteristic BVDSS Drain - Source Breakdown Voltage IDSS RDS(on) VGS(th) IGSS Zero Gate Voltage Drain Current Drain – Source on Resistance Gate Threshold Voltage Gate – Source Leakage Current Test Conditions VGS = 0V, ID = 1.5mA VGS = 0V,VDS = 200V VGS = 0V,VDS = 160V Tj = 25°C Tj = 125°C Min 200 Typ Max 500 3 6 5 ±500 VGS = 10V, ID = 150A VGS = VDS, ID = 6mA VGS = ±30 V, VDS = 0V 3 Unit V µA mA mW V nA Dynamic Characteristics Symbol Ciss Coss Crss Qg Qgs Qgd Td(on) Tr Td(off) Tf Eon Eoff Eon Eoff Characteristic Input Capacitance Output Capacitance Reverse Transfer Capacitance Total gate Charge Gate – Source Charge Gate – Drain Charge Turn-on Delay Time Rise Time Turn-off Delay Time Fall Time Turn-on Switching Energy u Turn-off Switching Energy v Turn-on Switching Energy u Turn-off Switching Energy v Test Conditions VGS = 0V VDS = 25V f = 1MHz VGS = 10V VBus = 100V ID = 300A Inductive switching @ 125°C VGS = 15V VBus = 133V ID = 300A RG = 0.8Ω Inductive switching @ 25°C VGS = 15V, VBus = 133V ID = 300A, RG = 0.8Ω Inductive switching @ 125°C VGS = 15V, VBus = 133V ID = 300A, RG = 0.8Ω Min Typ 18.5 6.03 0.58 325 144 156 28 56 81 99 1543 1517 2027 1770 µJ µJ Max Unit nF nC ns u Eon includes diode reverse recovery. v In accordance with JEDEC standard JESD24-1. Series diode ratings and characteristics Symbol Characteristic Maximum Average Forward Current IF(AV) VF Diode Forward Voltage Test Conditions 50% duty cycle IF = 120A IF = 240A IF = 120A IF = 120A VR = 133V di/dt = 400A/µs Min Tc = 85°C Typ 120 1.1 1.4 0.9 31 60 120 500 Max 1.15 V Unit A Tj = 125°C Tj = 25°C Tj = 125°C Tj = 25°C Tj = 125°C Qrr Reverse Recovery Charge nC APT website – http://www.advancedpower.com 2-6 APTM20AM06S – Rev 1 May, 2004 trr Reverse Recovery Time ns APTM20AM06S Parallel diode ratings and characteristics Symbol Characteristic Maximum Average Forward Current IF(AV) VF Diode Forward Voltage Test Conditions 50% duty cycle IF = 120A IF = 240A IF = 120A IF = 120A VR = 130V di/dt = 400A/µs Min Tc = 85°C Typ 120 1.1 1.4 0.9 31 60 120 500 Min Transistor Diode serie Diode parallel 2500 -40 -40 -40 3 2 Typ Max 0.10 0.46 0.46 150 125 100 5 3.5 280 Max 1.15 V Unit A Tj = 125°C Tj = 25°C Tj = 125°C Tj = 25°C Tj = 125°C trr Qrr Reverse Recovery Time Reverse Recovery Charge ns nC Thermal and package characteristics Symbol Characteristic RthJC VISOL TJ TSTG TC Torque Wt Junction to Case Unit °C/W V °C N.m g RMS Isolation Voltage, any terminal to case t =1 min, I isol ID(on)xRDS(on)MAX 250µs pulse test @ < 0.5 duty cycle 8V T J=125°C 200 6V TJ=25°C TJ=-55°C 0 0 2.5 5 7.5 10 12.5 15 VDS, Drain to Source Voltage (V) RDS(on) vs Drain Current 1.2 1.15 1.1 1.05 1 0.95 0.9 0 100 VGS=20V VGS=10V 2 3 4 5 6 7 8 9 10 VGS, Gate to Source Voltage (V) RDS(on) Drain to Source ON Resistance DC Drain Current vs Case Temperature 320 ID, DC Drain Current (A) 600 280 240 200 160 120 80 40 0 25 50 75 100 125 TC, Case Temperature (°C) 150 May, 2004 Normalized to VGS=10V @ 44.5A 200 300 400 500 ID, Drain Current (A) APT website – http://www.advancedpower.com 4-6 APTM20AM06S – Rev 1 APTM20AM06S RDS(on), Drain to Source ON resistance (Normalized) Breakdown Voltage vs Temperature BVDSS, Drain to Source Breakdown Voltage (Normalized) 1.2 1.1 1.0 0.9 0.8 0.7 -50 -25 0 25 50 75 100 125 150 TJ, Junction Temperature (°C) Threshold Voltage vs Temperature 1.2 VGS(TH), Threshold Voltage (Normalized) 1.1 1.0 0.9 0.8 0.7 0.6 -50 -25 0 25 50 75 100 125 150 TC, Case Temperature (°C) Capacitance vs Drain to Source Voltage 100000 C, Capacitance (pF) Ciss 10000 Coss 1 2.5 2.0 1.5 1.0 0.5 0.0 -50 -25 0 25 50 75 100 125 150 TJ, Junction Temperature (°C) Maximum Safe Operating Area ON resistance vs Temperature VGS=10V ID= 150A 10000 ID, Drain Current (A) 1000 limited by RDSon 100µs 1ms 10ms 100 10 Single pulse TJ=150°C DC line 1 10 100 1000 VDS, Drain to Source Voltage (V) Gate Charge vs Gate to Source Voltage 12 VDS=40V ID=300A 10 TJ=25°C V =100V DS VGS, Gate to Source Voltage (V) 8 6 4 2 0 0 60 120 180 240 VDS=160V 1000 Crss 100 0 10 20 30 40 50 VDS, Drain to Source Voltage (V) 300 360 Gate Charge (nC) May, 2004 APT website – http://www.advancedpower.com 5-6 APTM20AM06S – Rev 1 APTM20AM06S Delay Times vs Current 90 80 td(on) and td(off) (ns) 70 60 50 40 30 20 VDS=133V RG=0.8Ω TJ=125°C L=100µH Rise and Fall times vs Current 160 140 td(off) tr and tf (ns) 120 100 80 60 40 20 0 100 150 200 250 300 350 400 450 500 ID, Drain Current (A) Switching Energy vs Gate Resistance 6000 Switching Energy (µJ) 5000 4000 3000 2000 1000 0 2 4 6 8 10 Gate Resistance (Ohms) Source to Drain Diode Forward Voltage 10000 VDS=133V ID=300A TJ=125°C L=100µH VDS=133V RG=0.8Ω TJ=125°C L=100µH tf tr td(on) 10 100 150 200 250 300 350 400 450 500 ID, Drain Current (A) Switching Energy vs Current 4000 3500 Eon and Eoff (µJ) 3000 2500 2000 1500 1000 500 VDS=133V RG=0.8Ω TJ=125°C L=100µH Eon Eoff Eoff Eon 0 100 150 200 250 300 350 400 450 500 ID, Drain Current (A) Operating Frequency vs Drain Current 350 Frequency (kHz) 300 250 200 150 100 50 0 30 60 90 120 150 180 210 240 270 ID, Drain Current (A) VDS=133V D=50% RG=0.8Ω TJ=125°C IDR, Reverse Drain Current (A) 400 1000 TJ=150°C TJ=25°C 100 10 1 0.3 0.5 0.7 0.9 1.1 1.3 1.5 1.7 1.9 VSD, Source to Drain Voltage (V) May, 2004 APT's products are covered by one or more of U.S patents 4,895,810 5,045,903 5,089,434 5,182,234 5,019,522 5,262,336 6,503,786 5,256,583 4,748,103 5,283,202 5,231,474 5,434,095 5,528,058 and foreign patents. U.S and Foreign patents pending. All Rights Reserved. APT website – http://www.advancedpower.com 6-6 APTM20AM06S – Rev 1 APT reserves the right to change, without notice, the specifications and information contained herein
APTM20AM06S 价格&库存

很抱歉,暂时无法提供与“APTM20AM06S”相匹配的价格&库存,您可以联系我们找货

免费人工找货