0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
ELVH-001D-HNNH-C-N2A4

ELVH-001D-HNNH-C-N2A4

  • 厂商:

    AMPHENOL(安费诺)

  • 封装:

    SIP4

  • 描述:

    ELVH 1 PSI DIFF NN LID SIP COMME

  • 数据手册
  • 价格&库存
ELVH-001D-HNNH-C-N2A4 数据手册
ELV Series - Analog and Digital Pressure Sensor Product Families all sensors Table of Contents Features & Applications ................................... 2 Maximum Ratings ............................................ 2 Environmental Specifications ........................... 2 Equivalent Circuit ............................................ 2 ELVI & ELVE ..................................... 8 Introduction ELVA ................................................. 9 The ELV Analog and Digital Pressure Sensor Series consists of four new product families featuring All Sensors’ ultra low pressure CoBeam2 TM Technology. This innovative sensing element technology provides best-in-class stability for low and ultra low pressure ranges, with the ability to customize calibrations and pressure ranges from a proven world class supplier. How to Order Tables ELVH ............................................... 10 ELVI................................................. 11 ELVE ................................................ 12 ELVA ............................................... 13 Parylene Coating ........................................... 14 Soldering Recommendations ......................... 14 Digital Interfaces ELVH: I2C & SPI ......................... 15-18 ELVI: I2C .................................... 19-20 ELVE: SPI .................................... 21-22 Product Labeling & Pin Indicator ................... 23 Pressure Tubing Recommendations ............... 23 Pad Layouts ................................................... 23 Dimensional Package Drawings DIP ............................................. 24-26 SMT ............................................ 27-28 The ELV series gives design engineers outstanding flexibility with an exceptional number of choices in package combination. The digital interface eases integration of the sensors into a variety of process control and measurement systems, allowing direct connection to serial communications channels. These calibrated and compensated sensors provide accurate, stable output over a wide temperature range. This series is intended for use with non-corrosive, non-ionic working fluids such as air and other dry gases. A protective parylene coating is optionally available for moisture/harsh media protection. https://www.allsensors.com/products/elv-series SIP H-Lead ................................. 29-30 SIL F-Lead ................................... 31-33 All Sensors DS-0376 Rev A Page 1 of 34 f 408 225 2079 ELVH ................................................. 7 p 408 225 4314 Performance Characteristics a 16035 Vineyard Blvd. Morgan Hill, CA 95037 Pressure Ranges ............................................ 4-6 e www.allsensors.com Product Family Highlights ............................... 3 ELV Series: Analog & Digital Pressure Sensors Features • Pressure Ranges from ±0.5 inH2O to 150 psi and ±2.5mbar to ±10 bar • Precision ASIC Conditioning • Digital I2C or SPI Interface or Analog Only Options • 3V, 3.3V and 5V Supply Voltage Options Applications Wetted Media • Medical Devices • Silicon • Medical Instrumentation • RTV • Respiratory • Gold • Portable / Hand-Held Equipment • Ceramic • Environmental Controls • Epoxy • Environmental Instrumentation • Nylon Plastic • Environmental Monitoring • Aluminum • HVAC • Industrial Controls • Altimeters • Chemical Analysis • Meteorology Pressure Sensor Maximum Ratings Supply Voltage (Vs) Environmental Specifications Temperature Ranges Compensated: Standard Industrial 2.7 to 5.5 Vdc Maximum Device Temperature 245° Operating Storage -25°C to 85°C -40°C to 125°C 0°C to 50°C -20°C to 85°C Humidity Limits (non condensing) 0 to 95% RH Equivalent Circuit Analog I2C +Vs SPI +Vs SCL Vout GND SDA GND +Vs MISO CLK SS MOSI GND See package drawings for pinouts. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 2 of 34 ELVI, ELVE & ELVA Product Family Highlights Table of Contents a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 • 100 mbar up to 10 bar pressure ranges • Offered in Differential, Gage and Absolute pressure modes • -20 to 85°C Temperature compensation • Output options offered: • ELVI I2C only, non-ratiometric • ELVE SPI only, non-ratiometric • ELVA Analog only, ratiometric • 3V and 5V Supply Voltage offerings • Available in Numerous Port options: • No port • Barbed axial port • Needle big port • Other packages also available, check with factory • Numerous lead options: • SMT J-lead • DIP lead • SIL lead • Parylene Coating offered on pressure ranges of 100 mbar and above All Sensors e www.allsensors.com f 408 225 2079 • 0.5 inH2O up to 30 inH2O and 1 psi up to 150 psi pressure ranges. 100 mbar up to 10 bar pressure ranges • Offered in Differential, Gage and Absolute pressure modes • 0 to 50°C and -20 to 85°C Temperature compensation options • Output offered as • Digital I2C or SPI in 14 bit output or Ratiometric Analog option • 6 unique I2C address options • 4 unique transfer function options • 3.3V and 5V Supply Voltage offerings • Available in Numerous Port options: • No port • Barbed axial port • Needle big port • Side port • Other packages also available, check with factory • Numerous lead options: • SMT J-lead • DIP lead • SIP lead • Parylene Coating offered on pressure ranges of 10 inH2O and above all sensors ELVH Product Family Highlights DS-0376 Rev A Page 3 of 34 ELVH Series Pressure Ranges Pmin CODE Pmax Pressure Range1 Pressure Mode Common Mode Burst Pressure3 Pressure4 inH2O kPa inH2O kPa inH2O kPa F50D -0.5 0.5 Differential 0.1 270 67 415 103 415 103 L01D -1 1 Differential 0.2 270 67 415 103 415 103 L02D -2 2 Differential 0.5 270 67 415 103 415 103 L04D -4 4 Differential 1.0 300 75 415 103 415 103 L05D -5 5 Differential 1.2 300 75 415 103 415 103 L10D -10 10 Differential 2.5 350 87 415 103 415 103 L20D -20 20 Differential 5.0 350 87 415 103 415 103 L30D -30 30 Differential 7.5 350 87 415 103 415 103 L01G 0 1 Gage 0.2 270 67 415 103 415 103 L02G 0 2 Gage 0.5 270 67 415 103 415 103 L04G 0 4 Gage 1.0 300 75 415 103 415 103 L05G 0 5 Gage 1.2 300 75 415 103 415 103 L10G 0 10 Gage 2.5 350 87 415 103 415 103 L20G 0 20 Gage 5.0 350 87 415 103 415 103 L30G 0 30 Gage 7.5 350 87 415 103 415 103 CODE Pmax kPa Pmin inH2O Proof Pressure2 Pressure kPa psi kPa psi kPa psi kPa Mode psi 001D -1 1 Differential 7 10 69 15 103 15 103 005D -5 5 Differential 34 15 103 75 517 250 1724 015D -15 15 Differential 103 30 207 150 1034 250 1724 030D -30 30 Differential 207 60 414 250 1724 250 1724 060D -60 60 Differential 414 120 827 250 1724 250 1724 001G 0 1 Gage 7 10 69 15 103 15 103 005G 0 5 Gage 34 15 103 15 103 15 103 015G 0 15 Gage 103 30 207 75 517 250 1724 030G 0 30 Gage 207 60 414 150 1034 250 1724 060G 0 60 Gage 414 120 827 250 1724 250 1724 100G 0 100 Gage 690 250 1724 250 1724 250 1724 150G 0 150 Gage 1034 250 1724 250 1724 250 1724 015A 0 15 Absolute 103 15 103 15 103 15 103 030A 0 30 Absolute 207 60 414 150 1034 250 1724 060A 0 60 Absolute 414 120 827 250 1724 250 1724 100A 0 100 Absolute 690 250 1724 250 1724 250 1724 150A 0 150 Absolute 1034 250 1724 250 1724 250 1724 Note 1: Pressure ranges in Pa and kPa are expressed as an approximate value. Note 2: Differential Proof Pressure: The maximum pressure which may safely be applied to one port of the product for it to remain in specification once pressure is returned to the operating pressure range. Exposure to higher pressures may cause permanent damage to the product. Note 3: Differential Burst Pressure: The maximum pressure that may be applied to one port of the product without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the burst pressure. Note 4: Common Mode Pressure: The maximum pressure that can be applied simultaneously to both ports of a differential pressure sensor without causing escape of pressure media. Product should not be expected to function after exposure to any pressure beyond the this maximum pressure. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 4 of 34 ELVH Series Pressure Ranges (Cont'd) MF12D -12.5 12.5 kPa mbar kPa mbar kPa Differential 0.25 675 67.5 1034 103 1034 103 1.25 750 75 1034 103 1034 103 -25 25 Differential 2.5 850 85 1034 103 1034 103 M050D -50 50 Differential 5 850 85 1034 103 1034 103 M075D -75 75 Differential 7.5 850 85 1034 103 1034 103 M100D -100 100 Differential 10 850 85 1034 103 1034 103 M250D -250 250 Differential 25 850 85 5171 517 17237 1724 M500D -500 500 Differential 50 2000 200 5171 517 17237 1724 MF25G 0 2.5 Gage 0 675 68 1034 103 1034 103.4 MF12G 0 12.5 Gage 1.25 675 67.5 1034 103 1034 103 M025G 0 25 Gage 3 750 75 1034 103 1034 103.4 M050G 0 50 Gage 5 850 85 1034 103 1034 103 M075G 0 75 Gage 8 850 85 1034 103 1034 103.4 M100G 0 100 Gage 10 850 85 1034 103 1034 103 0 250 Gage 25 1034 103 1034 103 1034 103.4 0 500 Gage 50 1034 103 5171 517 17237 1724 MN50G -500 0 Gage -50 to 0 1034 103 5171 517 17237 1724 M611A 600 1100 Absolute 60 to 110 1034 103 5171 517 17237 1724 CODE kPa bar kPa bar kPa bar kPa Pmax M250G M500G Pmin Differential M025D bar Pressure Mode B001D -1 1 Differential 100 3.1 310 10.3 1034 17.2 1724 BF25D -2.5 2.5 Differential 250 7.2 720 17.2 1724 17.2 1724 B005D -5 5 Differential 500 12.4 1240 17.2 1724 17.2 1724 B010D -10 10 Differential 1000 17 1700 17.2 1724 17.2 1724 BN01G -1 0 Gage -100 to 0 2 200 5.2 517 17.2 1724 B001G 0 1 Gage 100 2 200 5.2 517 17.2 1724 BF25G 0 2.5 Gage 250 6.2 620 10.3 1034 17.2 1724 B005G 0 5 Gage 500 8 800 17.2 1724 17.2 1724 B010G 0 10 Gage 1000 17 1700 17.2 1724 17.2 1724 B001A 0 1 Absolute 100 1 100 1.0 103 1.0 103 B002A 0 2 Absolute 200 5 500 10.3 1034 17.2 1724 All Sensors Table of Contents DS-0376 Rev A Page 5 of 34 all sensors 2.5 mbar Mode e www.allsensors.com -2.5 kPa Pressure Pressure4 f 408 225 2079 MF25D Burst Pressure3 p 408 225 4314 mbar Common Mode Proof Pressure2 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 Pmin CODE Pmax Pressure Range1 ELVI, ELVE, ELVA Series Pressure Ranges Pmax CODE Pmin Pressure Range1 mbar Pressure Mode Common Mode Proof Pressure2 Burst Pressure3 kPa mbar kPa mbar kPa mbar kPa Pressure4 Differential 10 1034 103 1034 103 1034 103 M250D -250 250 Differential 25 1034 103 5171 517 17237 1724 M500D -500 500 Differential 50 1034 103 5171 517 17237 1724 M100G 0 100 Gage 10 1034 103 1034 103 1034 103 M250G 0 250 Gage 25 1034 103 5171 517 17237 1724 M500G 0 500 Gage 50 1034 103 5171 517 17237 1724 CODE Pmax -100 100 Pmin M100D Pressure kPa bar kPa bar kPa bar kPa bar Mode 1 Differential 100 3.1 310 10.3 1034 17.2 1724 0 1 Gage 100 3.1 310 10.3 1034 17.2 1724 BF25G 0 2.5 Gage 250 6 620 17.2 1724 17.2 1724 B005G 0 5 Gage 500 12 1240 17.2 1724 17.2 1724 B010G 0 10 Gage 1000 14 1400 17.2 1724 17.2 1724 B001A 0 1 Absolute 100 1 100 1.0 103 1.0 103 B002A 0 2 Absolute 200 5 500 10.3 1034 17.2 1724 CODE Pmax -1 B001G Pmin B001D Pressure kPa psi kPa psi kPa psi kPa psi Mode 001D -1 1 Differential 7 15 103 15 103 15 103 001G 0 1 Gage 7 15 103 15 103 15 103 100G 0 100 Gage 690 200 1379 250 1724 250 1724 ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 6 of 34 ELVH Output Series Performance Table 3.3V or 5V, Ref temp 25°C. Positive Pressure applied to Port B (top port) Digital Parameter Max Analog Min Typ Units xxxD (Differential) - ±6553 - Count (Dec) xxxG (Gage), xxxA (Absolute) - 13107 - Count (Dec) xxxD (Differential) - ±7373 - Count (Dec) xxxG (Gage), xxxA (Absolute) - 14746 - Count (Dec) xxxD (Differential) - 8192 - Count (Dec) xxxG (Gage), xxxA (Absolute) - 1638 - Count (Dec) xxxD (Differential) - 8192 - xxxG (Gage), xxxA (Absolute) - 819 - xxxD (Differential) - 7373 xxxG (Gage), xxxA (Absolute) - 819 xxxD (Differential) - xxxG (Gage), xxxA (Absolute) - Notes Min Typ Max Units Notes 5 - ±40% VS - V 5 5 - 80% VS - V 5 5 - ±45% VS - V 5 5 - 90% VS - V 5 - - 50% VS - V - - - 10% VS - V - Count (Dec) - - 50% VS - V - Count (Dec) - - 5% VS - V - - Count (Dec) - - 45% VS - V - - Count (Dec) - - 5% VS - V - 8028 - Count (Dec) - - 49% VS - V - 655 - Count (Dec) - - 4% VS - V - - - ±0.25 %FSS 6 - - ±0.25 %FSS 6 F50D & L01G - ±0.5 ±3 %FSS 7 - ±0.5 ±3 %FSS 7 L01D & L02G - ±0.5 ±2 %FSS 7 - ±0.5 ±2 %FSS 7 L04G - ±0.5 ±1.5 %FSS 7 - ±0.5 ±1.5 %FSS 7 Remaining ranges - ±0.5 ±1 %FSS 7 - ±0.5 ±1 %FSS 7 L02x and Below - ±0.2 - %FSS 8 - ±0.2 - %FSS Above L02x %FSS Full Scale Span (10% - 90%, 5% - 85% Transfer Function Options) Offset (10% - 90% Transfer Function Option) (5% - 95% Transfer Function Option) all sensors (5% - 95%, 4% - 94% Transfer Function Options) 8 Position Sensitivity - ±0.1 - %FSS 8 - ±0.1 - Startup Time - - 3 ms - - - 5 ms - Response Time - 0.46 - ms - - 1 - ms - 3.3V Supply Option - 3.1 3.9 mA - - 2.1 2.8 mA - 5V Supply Option - 3.7 4.6 mA - - 2.7 3.5 mA - Supply Current ELVH Output Performance Specification Notes Note 5: Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specfied pressure. Note 6: Accuracy is the measured deviation based on Best Fit Straight Line (BFSL). Note 7: Total Error Band is calculated from a combination of all possible errors, including offset, span temperature, calibration, linearity, pressure hysteresis, offset warm-up shift, offset position sensitivity, and long term offset drift. Note 8: Parameter is characterized and not 100% tested. All Sensors Table of Contents DS-0376 Rev A Page 7 of 34 f 408 225 2079 Total Error Band (TEB) p 408 225 4314 Accuracy a 16035 Vineyard Blvd. Morgan Hill, CA 95037 (4% - 94% Transfer Function Option) e www.allsensors.com (5% - 85% Transfer Function Option) ELVI & ELVE Output Series Performance Table 3 or 5V, Ref temp 25°C. Positive Pressure applied to Port B (top port) Digital Parameter Min Typ Max Units Notes - 27000 - Count (Dec) 5 Min Pressure 2595 3000 3405 Count (Dec) - Max Pressure 29595 30000 30405 Count (Dec) - xxxD (Differential) 16095 16500 16905 Count (Dec) - xxxG (Gage), xxxA (Absolute) 2595 3000 3405 Count (Dec) - Accuracy - - ±0.25 %FSS 6 Total Error Band (TEB) - - ±1.5 %FSS 7 A/D Resolution - 12 - bit - Response Delay - 0.5 - ms 9 3V Supply Option - 4.5 - mA - 5V Supply Option - 5.3 - mA - Full Scale Span (FSS) Full Scale Output (FSO) Offset Current Consumption ELVI & ELVE Output Performance Specification Notes Note 5: Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. Note 6: Accuracy is the measured deviation based on Best Fit Straight Line (BFSL). Note 7: Total Error Band is calculated from a combination of all possible errors, including offset, span temperature, calibration, linearity, pressure hysteresis, offset warm-up shift, offset position sensitivity, and long term offset drift. Note 9: Max. delay time between pressure change at the pressure die and signal change at the output. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 8 of 34 ELVA Output Series Performance Table 3 or 5V, Ref temp 25°C. Positive Pressure applied to Port B (top port) Parameter Analog Min Typ Max Units Notes 3V Supply Option - 2.4 - V 5 5V Supply Option - 4 - V 5 Min Pressure 0.26 0.3 0.34 V - Max Pressure 2.66 2.7 2.74 V - Min Pressure 0.44 0.5 0.56 V - Max Pressure 4.44 4.5 4.56 V - xxxD (Differential) 1.46 1.5 1.54 V - xxxG (Gage), xxxA (Absolute) 0.26 0.3 0.34 V - xxxD (Differential) 2.44 2.5 2.56 V - xxxG (Gage), xxxA (Absolute) 0.44 0.5 0.56 V - Accuracy - - ±0.25 %FSS 6 Total Error Band (TEB) - - ±1.5 %FSS 7 A/D Resolution - 12 - bit - D/A Resolution - - 11 bit - Response Delay - 0.5 - ms 9 3V Supply Option - 4.5 - mA - 5V Supply Option - 5.3 - mA - Current Consumption ELVA Output Performance Specification Notes Note 5: Full Scale Span (FSS) is the algebraic difference between the output signal for the highest and lowest specified pressure. Note 6: Accuracy is the measured deviation based on Best Fit Straight Line (BFSL). Note 7: Total Error Band is calculated from a combination of all possible errors, including offset, span temperature, calibration, linearity, pressure hysteresis, offset warm-up shift, offset position sensitivity, and long term offset drift. Note 9: Max. delay time between pressure change at the pressure die and signal change at the output. All Sensors Table of Contents DS-0376 Rev A Page 9 of 34 e www.allsensors.com Offset (5V Option) f 408 225 2079 Offset (3V Option) p 408 225 4314 Full Scale Output (FSO) (5V Option) a 16035 Vineyard Blvd. Morgan Hill, CA 95037 Full Scale Output (FSO) (3V Option) all sensors Full Scale Span (FSS) How to Order ELVH Series For example, ELVH-L01D-HRRD-C-NAA4 defines an All Sensors ELVH Series Analog + Digital Presure Sensor, 1 inH2O differential pressure range, HRRD package (DIP with dual same side barbed ports), compensated temperature range from 0°C to 50°C, no parylene coating, Analog output,10 to 90% of Vsupply transfer function, 3.3 Vdc supply voltage. ELVH - L01D - HRRD - C - N A A 4 Product Series ELV Digital and Analog Series Supply Voltage Coating Pressure Ranges Note 10 Differential Gage Absolute N No Parylene P Parylene 4 3.3 Vdc 5 5.0 Vdc Transfer Function F50D ± 0.5 inH2O L01G 0 to 1 inH2O 015A 0 to 15 psi A 10% to 90% of Vsupply (analog), 214 counts (digital) L01D ± 1 inH2O L02G 0 to 2 inH2O 030A 0 to 30 psi B 5% to 95% of Vsupply (analog), 214 counts (digital) L02D ± 2 inH2O L04G 0 to 4 inH2O 060A 0 to 60 psi C 5% to 85% of Vsupply (analog), 214 counts (digital) L04D ± 4 inH2O L05G 0 to 5 inH2O 100A 0 to 100 psi D 4% to 94% of Vsupply (analog), 214 counts (digital) L05D ± 5 inH2O L10G 0 to 10 inH2O 150A 0 to 150 psi L10D ± 10 inH2O L20G 0 to 20 inH2O M611A 600 to 1100 mbar C 0°C to 50°C L20D ± 20 inH2O L30G 0 to 30 inH2O B001A 0 to 1 bar I -20°C to 85°C L30D ± 30 inH2O 001G 0 to 1 psi B002A 0 to 2 bar 001D ± 1 psi 005G 0 to 5 psi 005D ± 5 psi 015G 0 to 15 psi A 015D ± 15 psi 030G 0 to 30 psi S Compensated Temperature Range Package Pinout Offering Code* Output Interface DIP (8 pin) SMT (8 pin) 3 3 4 SPI 2 2 Not Available 2 Analog, (H-Style) 030D ± 30 psi 060G 0 to 60 psi 2 I C, Address 0x28 1 060D ± 60 psi 100G 0 to 100 psi 3 I2C, Address 0x38 MF25D ± 2.5 mbar 150G 0 to 150 psi 4 MF25G 0 to 2.5 mbar MF12D ± 12.5 mbar 5 MF12G 0 to 12.5 mbar M025D ± 25 mbar M050D ± 50 mbar M025G 0 to 25 mbar M075D ± 75 mbar M050G 0 to 50 mbar M100D ± 100 mbar M075G 0 to 75 mbar M250D ± 250 mbar M100G 0 to 100 mbar M500D ± 500 mbar M250G 0 to 250 mbar B001D ± 1 bar M500G 0 to 500 mbar BF25D ± 2.5 bar MN50G -500 to 0 mbar B005D ± 5 bar BN01G -1 to 0 bar B010D ± 10 bar B001G 0 to 1 bar 6 7 SIP (4 pin) 1 5 1 1 5 2 1 1 5 2 1 1 5 2 1 1 5 2 1 1 5 I C, Address 0x48 I C, Address 0x58 I C, Address 0x68 I C, Address 0x78 Package Selection (4 Character Code) Note 10 DIP BF25G 0 to 2.5 bar B005G 0 to 5 bar SMT J-Lead SIP HNND HNNJ HNNH HAND HANJ HANH B010G 0 to 10 bar — — *Package Pinout Offering Code Legend Pin Code Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 1 GND VS SDA SCL N/C N/C N/C Pin 8 N/C 2 GND VS MISO SCLK SS N/C N/C N/C 3 N/C VS VOUT GND N/C N/C N/C N/C 4 N/C VS VOUT GND - - - - 5 GND VS SDA SCL - - - - N/C: Not Internally Connected HAAH HRND HRNJ HRNH HRRD HRRJ HRRH HDRD HDRJ HDRH HKND HKNJ — Note 10: Sideport packages (HRNx, HRRx, HDRx) are limied to maximum pressure ranges of 60 psid / 60 psig / 60 psia. Refer to the Part Number Builder application on All Sensors’ website for help with cross reference to alternative suppliers’ part numbers. Note: Parylene Coating is not availble for pressure ranges below 10 inH2O or for J-Lead configurations. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 10 of 34 How to Order ELVI Series For example, ELVI-M100D-HNNJ-C-N2E3 defines an All Sensors ELVI Series Digital Presure Sensor, 100 mbar differential pressure range, HNNJ package (SMT J-Lead with no ports), compensated temperature range from 0°C to 50°C, no parylene coating, I2C Output, Address 0x28, 9.16% to 91.55% of 215 counts (digital) transfer function and 3 Vdc supply voltage. HNNJ - C - N 2 E 3 Product Series ELV Digital and Analog Series Supply Voltage Coating Pressure Ranges Note 10 Differential Gage Absolute N No Parylene P Parylene 3 3 Vdc 5 5 Vdc Transfer Function M100D ± 100 mbar M100G 0 to 100 mbar B001A 0 to 1 bar M250D ± 250 mbar M250G 0 to 250 mbar B002A 0 to 2 bar M500D ± 500 mbar M500G 0 to 500 mbar B001D ± 1 bar B001G 0 to 1 bar 001D ± 1 psi BF25G 0 to 2.5 bar B005G 0 to 5 bar C 0°C to 50°C B010G 0 to 10 bar I -20°C to 85°C 001G 0 to 1 psi 100G 0 to 100 psi 9.16% to 91.55% of 215 counts (digital) E Compensated Temperature Range Package Pinout Offering Code* Output Interface 2 3 SMT (8 pin) SIL (4 pin) 1 1 5 2 1 1 5 2 I2C, Address 0x28 I C, Address 0x38 DIP (8 pin) 4 I C, Address 0x48 1 1 5 5 I2C, Address 0x58 1 1 5 6 I2C, Address 0x68 1 1 5 7 I2C, Address 0x78 1 1 5 Package Selection (4 Character Code) Note 10 SMT J-Lead DIP HNND *Package Pinout Offering Code Legend HNNF HNNJ HAND SIL F-Lead Pin Code Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 1 Vs GND N/C N/C SCL N/C N/C SDA 5 Vs GND SCL SDA - - - - HANF HANJ N/C: Not Internally Connected HKND — HKNF HKNJ HCND HAAF p 408 225 4314 — — — Note 10: Sideport packages (HRNx, HRRx, HDRx) are limied to maximum pressure ranges of 60 psid / 60 psig / 60 psia. Refer to the Part Number Builder application on All Sensors’ website for help with cross reference to alternative suppliers’ part numbers. Note: Parylene Coating is not availble for pressure ranges below 10 inH2O or for J-Lead configurations. All Sensors Table of Contents all sensors - e www.allsensors.com M100D f 408 225 2079 - DS-0376 Rev A Page 11 of 34 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 ELVI How to Order ELVE Series For example, ELVE-M100D-HNND-C-NTE3 defines an All Sensors ELVE Series Digital Presure Sensor, 100 mbar differential pressure range, HNNF package (DIP with no ports), compensated temperature range from 0°C to 50°C, no parylene coating, SPI Output, 9.16% to 91.55% of 215 counts transfer function and 3 Vdc supply voltage. ELVE - M100D - HNND - C - N T E 3 Product Series ELV Digital and Analog Series Supply Voltage Coating Pressure Ranges Note 10 Differential Gage Absolute N No Parylene P Parylene M100D ± 100 mbar M100G 0 to 100 mbar B001A 0 to 1 bar M250D ± 250 mbar M250G 0 to 250 mbar B002A 0 to 2 bar M500D ± 500 mbar M500G 0 to 500 mbar B001D ± 1 bar B001G 0 to 1 bar 001D ± 1 psi BF25G 0 to 2.5 bar B005G 0 to 5 bar C 0°C to 50°C B010G 0 to 10 bar I -20°C to 85°C 001G 0 to 1 psi 100G 0 to 100 psi 3 3 Vdc 5 5 Vdc Transfer Function 9.16% to 91.55% of 215 counts (digital) E Compensated Temperature Range Package Pinout Offering Code* Output Interface SPI T DIP (8 pin) SMT (8 pin) SIL (4 pin) 2 2 Not Available Package Selection (4 Character Code) SMT J-Lead DIP HNND HNNJ HAND HANJ HKND HKNJ HCND — *Package Pinout Offering Code Legend Pin Code Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 2 Vs GND N/C MISO SCLK SS N/C MOSI N/C: Not Internally Connected Note 10: Sideport packages (HRNx, HRRx, HDRx) are limied to maximum pressure ranges of 60 psid / 60 psig / 60 psia. Refer to the Part Number Builder application on All Sensors’ website for help with cross reference to alternative suppliers’ part numbers. Note: Parylene Coating is not availble for pressure ranges below 10 inH2O or for J-Lead configurations. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 12 of 34 How to Order ELVA Series For example, ELVA-M100D-HNNF-C-NBF3 defines an All Sensors ELVA Series Analog Presure Sensor, 100 mbar differential pressure range, HNNF package (SIL with no ports), compensated temperature range from 0°C to 50°C, no parylene coating, Analog Output, 10 to 90% Vsupply transfer function and 3 Vdc supply voltage. M100D - HNNF - C - N B F 3 Product Series ELV Digital and Analog Series Supply Voltage Coating Pressure Ranges Note 10 Gage Absolute No Parylene P Parylene M100D ± 100 mbar M100G 0 to 100 mbar B001A 0 to 1 bar M250D ± 250 mbar M250G 0 to 250 mbar B002A 0 to 2 bar M500D ± 500 mbar M500G 0 to 500 mbar B001D ± 1 bar B001G 0 to 1 bar 001D ± 1 psi BF25G 0 to 2.5 bar B005G 0 to 5 bar C 0°C to 50°C B010G 0 to 10 bar I -20°C to 85°C 001G 0 to 1 psi 100G 0 to 100 psi 3 Vdc 5 5 Vdc Transfer Function F 10% to 90% of Vsupply (analog) Compensated Temperature Range Package Pinout Offering Code* Output Interface Analog B DIP (8 pin) SMT (8 pin) SIL (4 pin) 3 3 4 Package Selection (4 Character Code) Note 10 SMT J-Lead HNND HNNJ HNNF HAND HANJ HANF — HAAF — HKND HKNF HKNJ HCND f 408 225 2079 SIL F-Lead p 408 225 4314 DIP — — *Package Pinout Offering Code Legend Pin Code Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Pin 6 Pin 7 Pin 8 3 Vs GND VOUT N/C N/C N/C N/C N/C 4 Vs GND VOUT N/C - - - - N/C: Not Internally Connected Note 10: Sideport packages (HRNx, HRRx, HDRx) are limied to maximum pressure ranges of 60 psid / 60 psig / 60 psia. Refer to the Part Number Builder application on All Sensors’ website for help with cross reference to alternative suppliers’ part numbers. Note: Parylene Coating is not availble for pressure ranges below 10 inH2O or for J-Lead configurations. All Sensors Table of Contents DS-0376 Rev A Page 13 of 34 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 Differential N 3 all sensors - e www.allsensors.com ELVA Device Options Parylene Coating: Parylene coating provides a moisture barrier and protection from some harsh media. Unlike other pressure sensor suppliers offering a Parylene coating, All Sensors performs this process in-house and uses an advanced production system to achieve the highest accuracy and reliability. This avoids transferring products out of and back to the pressure sensor manufacturing facility, provides complete quality control and improves the delivery time to customers. Specially designed masking techniques allow All Sensors to apply a cost-effective, high-volume Parylene coating in-house. Consult factory for applicability of Parylene for the target application and sensor type. This option is only available for pressure ranges of ±10 inH2O and above and is not available for J-lead configurations. Soldering Recommendations: 1) If possible, solder parts as a second operation only. 2) Post reflow and other high temperature processes, wait for 48 hrs before performing any calibration operations. 3) Perform spot cleaning as necessary only by hand. DO NOT wash or submerge device in cleaning liquid. 4) Max 270°C lead temperature (manual soldering 2-4 sec.) If these devices are to be subjected to solder reflow assembly or other high temperature processing, they must be baked for 1 hour at 125°C within 24 hours prior to exposure. Failure to comply may result in cracking and/or delamination of critcal interfaces within the package, and is not covered by warranty. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 14 of 34 I2C Interface for ELVH Series The part enters Free Running mode (see table 1) after power-up: it performs an initial complete measurement, writes the calculated data to the output registers, sets the INT pin high, then starts the next reading. Note that a “special cycle” occurs every 255 cycles (~120 msec), which adds 400 μsec to the update time for that cycle. Acknowledge (A or N): Data is transferred in units of 8 bits (1 byte) at a time, MSB first. Each data-receiving device, whether master or slave, is required to pull the data line LOW to acknowledge receipt of the data. The Master must generate an extra clock pulse for this purpose. If the receiver does not pull the data line down, a NACK condition exists, and the slave transmitter becomes inactive. The master determines whether to send the last command again or to set the STOP condition, ending the transfer. DATA valid (Dn): State of data line represents valid data when, after a START condition, data line is stable for duration of HIGH period of clock signal. Data on line must be changed during LOW period of clock signal. There is one clock pulse per data bit. DATA operation: The sensor starts to send 4 data bytes containing the current pressure and temperature values. The transmission may be halted by the host after any of the bytes by responding with a NACK. STOP condition (P): LOW to HIGH transition of the SDA line while clock (SCL) is HIGH indicates a STOP condition. STOP conditions are always generated by the master. All Sensors Table of Contents DS-0376 Rev A Page 15 of 34 e www.allsensors.com Slave address (An): The I2C-bus requires a unique address for each device. After setting a START condition the master sends the address byte containing the 7 bit sensor address followed by a data direction bit (R/W). A "0" indicates a transmission from master to slave (WRITE), a "1" indicates a data request (READ). f 408 225 2079 START condition (ST): A HIGH to LOW transition of SDA line while the clock (SCL) is HIGH is interpreted as START condition. START conditions are always set by the master. Each initial request for a pressure value has to begin with a START condition. p 408 225 4314 Bus not Busy (I): During idle periods both data line (SDA) and clock line (SCL) remain HIGH. a 16035 Vineyard Blvd. Morgan Hill, CA 95037 The I2C interface uses a set of signal sequences for communication. The following is a description of the supported sequences. Refer to Figure 3 for usage. all sensors I2C Communications Overview I2C Exceptions 1. Sending a Start condition, then a Stop condition, without any transitions on the CLK line, creates a communication error for the next communication, even if the next start condition is correct and the clock pulse is applied. A second Start condition must be set, which clears the error and allows communication to proceed. 2. The Restart condition—a falling SDA edge during data transmission when the CLK clock line is still high— creates the same stall/deadlock. In the following data request, an additional Start condition must be sent for correct communication. 3. A falling SDA edge is not allowed between the start condition and the first rising SCL edge. If using an I2C address with the first bit 0, SDA must be held low from the start condition through the first bit. Figure 3 - I2C Communication Diagram I2C Communications Diagram 1. Read Data ( with examples of reading pressure, pressure plus 8 bits of temperature and pressure plus 11 bits of temperature ) A Set by bus master: -I - - ST - A6 A5 A4 A3 A2 A1 A0 R D23 … D16 Set by sensor ( pressure plus status ): - - - - - - - - - - - -A- -D31 - - -…- -D24 …then, one of the following: a) Set by bus master, to stop transfer after pressure data received: - - - - - - - - - - - - - -N- - -SP - - - I- - - --OR-b) Set by bus master, to stop transfer after first temperature data byte received: - - - - -A- - - - - - - - - N SP I Set by sensor ( high order 8 bits of temperature ): - - - - - - - - - - - - - - - - - - - - - - - - - - - D15 - - - -… - - -D8 --OR-A N SP I c) Set by bus master, to stop transfer after last temperature data byte received: - - - - - A- - - - - - - - D7 … D0 Set by sensor ( all 11 bits of temperature plus padding bits ): - - - - - - - - - - - - - - - - - - - D15 - - - -… - - -D8 - Bus states Idle: Start: Stop: Ack: Nack: “Read” bit (1): “Write” bit (0): I ST SP A N R W Sensor Address A6 … A0 Data format Status: Pressure data: Temperature data: (padding bits:) D31 D29 D15 D4 D30 … D16 … D5 … D0 Figure 3 illustrates the sequence of signals set by both the host and the sensor for each command. Note that for the ReadData command, the host has the option of responding to the second or third bytes of data with a NACK instead of ACK. This terminates the data transmission after the pressure data, or after the pressure data and upper byte of temperature, have been transmitted. See Figure 6 for the I2C timing details. ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 16 of 34 SPI Interface for ELVH Series After power-up, the part enters Free Running mode and begins its periodic conversion cycle. The only bus interaction with the host is the SPI DataRead operation. Polling the sensor at a rate slower than the internal update rate will minimize bus activity and ensure that new values are presented with each transfer. Note that the Status bits should still be checked to verify updated data and the absence of error conditions. SPI Bit Pattern e www.allsensors.com The sequence of bits and bus signals are shown in the following illustration (Figure 4). Refer to Figure 5 in the Interface Timing Diagram section for detailed timing data. As previously described, the incoming data may be terminated by raising SS after 2, 3, or 4 bytes have been received as illustrated below. all sensors ELVH sensors using the SPI interface option provide 3 signals for communication: SCLK, SS (Slave Select), and MISO. a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 Figure 4 - SPI Bit Pattern All Sensors Table of Contents DS-0376 Rev A Page 17 of 34 Interface Timing Diagrams for ELVH Series Figure 5 - SPI Timing Diagram tSCLK tLOW tSSCLK tHIGH SCLK MISO (HI•Z) (HI•Z) tCLKD tCLKD SS tCLKSS P ARAMETER S CLK clock frequency (4MHz clock) S CLK clock frequency (1MHz clock) S S drop to firs t clock edge Minimum S CLK clock low width Minimum S CLK clock high width Clock edge to data trans ition Ris e of S S relative to las t clock edge Bus free time between ris e and fall of S S S YMBOL MIN f SCLK f SCLK 50 50 2.5 0.6 0.6 0 0.1 2 tSSCLK tLOW tHIGH tCLKD tCLKSS tIDLE TYP - tIDLE MAX 800 200 0.1 - UNITS kHz kHz µs µs µs µs µs µs Figure 6 - I2C Timing Diagram tH STA tHIGH tLOW SCL SDA tSUSTA tSUDAT P ARAMETER tH DAT S YMBOL S CL clock frequency S tart condition hold time relative to S CL edge Minimum S CL clock low width Minim um S CL clock high width S tart condition s etup time relative to S CL edge Data hold time on S DA relative to S CL edge Data s etup time on S DA relative to S CL edge S top condition s etup time on S CL Bus free time between s top condition and s tart cond . fSCL tHSTA tLOW tHIGH tSUSTA tHDA T tSUDA T tSUSTP tIDLE MIN 100 0.6 0.6 0.6 0.1 0 0.1 0.6 2 tSUSTP TYP - tIDLE MAX 400 - UNITS kHz kHz µs µs µs µs µs µs µs ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 18 of 34 I2C Interface for ELVI Series Acknowledge (A) : HIGH to LOW transition of SDA line while clock (SCL) is HIGH is interpreted as START condition. START conditions are always generated by the master. Each initial request for a pressure value has to begin with a START condition. According to the I2C-bus specification, the bus is controlled by a master device, which generates the clock signal, controls the bus access, and generates START and STOP conditions. These sensors are designed to work as slave devices, and will only respond to requests from a master device. Slave address : The I2C-bus master-slave concept requires a unique address for each device. These sensors have a preconfigured slave address, see the ELVI “How to Order” table on page 11. The sensor will then listen to both this address and 0x78. After generating a START condition the master sends the address byte containing a 7 bit address followed by a data direction bit (R/W). A “0” indicates a trasmission from master to slave (WRITE), a “1” indicates a data request (READ). Digital I2C Interface These devices comply with the following protocol in Figure 7, and timing as specified in Table 1 and Figure 8. Bus not busy : During idle periods, both data line (SDA) and clock line (SCL) remain HIGH. START condition (S) : HIGH to LOW transition of SDA line while clock (SCL) is HIGH is interpreted as START condition. START conditions are always generated by the master. Each initial request for a pressure value has to begin with a START condition. DATA operation : The sensor sends 2 data bytes containing the current pressure value as a 15 bit value placed in the output registers. f 408 225 2079 STOP condition (P) : LOW to HIGH transition of SDA line while clock (SCL) is HIGH determines STOP condition. STOP conditions are always generated by the master. More than one request for the current pressure value can be transmitted without genration of intermediate STOP condition. e www.allsensors.com The ELVI series sensors provide a digital output signal. The device runs a continuous program, which will store a corrected pressure value every 0.5 ms in the output registers of the internal ASIC. all sensors DATA valid (D) : State of data line represents valid data when, after START condition, data line is stable for duration of HIGH period of clock signal. Data on line must be changed during LOW period of clock signal. There is one clock pulse per bit of data. Introduction p 408 225 4314 SCL SDA Data valid 1 S Slave Address R/W A Data allowed to change Data Byte 1 A STOP condition Data Byte 2 Read out of first pressure value generated by master generated by slave A Data Byte 1 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 START condition P Read out of next pressure values (optional) S = START condition Data Byte 1 = High Byte (MSB first) A = Acknowledge Data Byte 2 = Low Byte (LSB last) P = STOP condition Figure 7: I²C bus protocol All Sensors Table of Contents DS-0376 Rev A Page 19 of 34 ELVI I2C BUS INTERFACE (Cont'd) Table 1 I2C Interface Parameters Parameter Specification Symbol Minimum Nominal Maximum Unit Input High Level - 90 - 100 % of Vs Input Low Level - 0 - 10 % of Vs 8 Output Low Level - - - 10 % of Vs 8 - 500 - - Ω 8 CSDA - - 400 pF 8 Pull-Up Resistor Load Capacitance @ SDA Notes 8 CI2C_IN - - 10 pF 8 Signal Clock Frequency FSCL 100* - 400 kHZ 8 Bus Free Time Between STOP and START Condition tBUF 1.3 - - µs 8 Input Capacitance @ SDA/SCL tHD.STA 0.8 - - µs 8 Low Period of SCL tLow 1.3 - - µs 8 High Period of SCL Hold Time (Repeated) START Condition, to First Clock Pulse tHigh 0.6 - - µs 8 Setup Time Repeated START Condition tSU.STA 1 - - µs 8 Data Hold Time tHD.DAT 0 - - µs 8 Data Setup Time tSU.DAT 0.2 - - µs 8 Rise Time of Both SDA and SCL tR - - 0.3 µs 8 Fall Time of Both SDA and SCL tF - - 0.3 µs 8 tSU.STO 0.6 - - µs 8 Setup Time for STOP Condition Note 8: Parameter is characterized and not 100% tested. Note: All Sensors recommends communication speeds of at least 100 kHz (max. 640 kHz). Please contact your nearest All Sensors sales office for further information. tS U;DAT tHD;DAT tS U;S TA tHD;S TA tR tS U;S TO tBUF tHD;S TA tF S CL S DA tHIGH tLOW S CL S DA Figure 8. Timing Characteristics ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 20 of 34 SPI - SERIAL PERIPHERAL INTERFACE for ELVE Series Introduction The ELVE series supports clock phase (CPHA)=0 and polarity (CPOL)=0, which means that SCK is low when idle and data is sampled on the rising edge. The ELVE series sensors present a digital output signal. The device runs a continuous program, which will store a corrected sensor value about every 0.5 ms in the output registers of the internal ASIC. This cyclic program runs independently from the bus communication. Slave Select The SPI protocol specifies four signals: The clock (CLK) is generated by the master and input to all slaves. MOSI carries data from master to slave. MISO carries data from slave back to master. A slave select line (SS) allows individual selection of a slave device. Data Operation The MOSI line should always be set to high level. Because of internal configuration, the slave will answer the first byte with a value of 0xFF. The second and third byte contain the 15 bit pressure information (see Figure 10.) Timing requirements for these signals is shown in Table 2 and Figure 11. SPI Modes SCK Cycle 1 2 3 4 5 6 7 e www.allsensors.com A pair of parameters called clock polarity (CPOL) and clock phase (CPHA) determine the edges of the clock signal on which the data are driven and sampled. Each of the two parameters has two possible states, which allows for four possible combinations, all of which are incompatible with one another. 8 LSB MSB MISO f 408 225 2079 SCK (CPOL=0) MOSI MSB LSB p 408 225 4314 SS Sampling Figure 9: Example of a standard 1 byte SPI data transfer for CPHA=0 and CPOL=0 Data Byte 2 1 1 1 1 1 Data Byte 3 MOSI 1 1 1 1 1 1 1 1 1 1 1 1 1 MISO X X X X X X X X X P15 P14 P12 P11 P10 P9 P8 P7 P6 P5 P4 P3 P2 P1 P0 1 1 1 1 1 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 Data Byte 1 1 Relevant data Figure 10: 3 byte data stream between ELVF sensor and master containing the pressure value as a 15 bit value. All Sensors Table of Contents all sensors The falling edge of the SS line indicates the beginning of the transfer. Additionally, the SS line must not be negated and reasserted between the three bytes to be transmitted. DS-0376 Rev A Page 21 of 34 ELVE SPI - SERIAL PERIPHERAL INTERFACE (Cont'd) Table 2 Interface Parameters Parameter Specification Symbol Minimum Nominal Maximum Unit Input High Level - 90 - 100 % of Vs 8 Input Low Level - 0 - 10 % of Vs 8 Output Low Level - - - 10 % of Vs 8 Pull-Up Resistor - 500 - - Ω 8 Load Capacitance @ MISO CMISO - - 400 pF 8 Input Capacitance @ Each Pin CSPI_IN - - 10 pF 8 fSCK 100 - 640 kHZ 8 MISO Hold Time after SCK Sample Slope tSPI_HD_MISO 200 - - ns 8 MOSI Setup Time Before SCK Sample Slope tSPI_SU_MOSI 2/fCLK - - - 8 /SS Setup Time Before SCK Sample Slope tSPI_SU_SS 10 - - ns 8 /SS Hold Time After SCK Sample Slope tSPI_HD_SS 1/fCLK - - - 8 Signal Clock Frequency Notes Note 8: Parameter is characterized and not 100% tested. Note: All Sensors recommends SPI communication speeds of at least 100 kHz (max. 640 kHz). Please contact your nearest All Sensors sales office for further information. t t SPI_SU_SS SPI_HD_SS t SPI_SU_MOSI SCK (CPOL=0) t SPI_HD_MISO MOSI MISO SS Figure 11: Timing characteristics ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 22 of 34 Product Labeling and Pin Indicator Product Marking HMF25GCNAA4 all sensors Lot Number R20A0101 Example Product Laser Marking: HMF25GCNAA4 H MF25G C N A A 4 Product Family: ELVH, ELVI, ELVE, ELVA Pressure Range& Pressure Mode e www.allsensors.com Compensated Temperature Range Pin 1 Indicator Pin 1 Output Interface Transfer Function Pressure Tubing Recommendations Tubing Recommendations Lid Type ID A R C K N 5/32" 1/16" 1/8" 3/32" Material* Low Pressure High Pressure 1/4" Silicone Polyurethane 1/8" Silicone Polyurethane 1/4" Silicone Polyurethane 5/32" Silicone Polyurethane O-ring face seal OD Low Pressure is defined as pressure ranges below 15 psi. High Pressure is defined as pressure ranges above 15 psi. Note: 15 psi absolute is considered low pressure, whereas 15 psi differential and gage are considered high pressure. Suggested Pad Layouts DIP [ 0.89~0.99 mm] .035~.039 inch (Finished Size) SMT 2.03 0.080 2.54 0.100 (typ.) 1.14 0.045 0.89~0.99 mm] 0.035~0.039 inch (Finished Size) 2.54 0.100 (typ.) SIP & SIL [ 2.54 0.100 (typ.) 13.08 0.515 PAD-01 All Sensors Table of Contents PAD-31 9.40 0.370 PAD-32 DS-0376 Rev A Page 23 of 34 p 408 225 4314 f 408 225 2079 Supply Voltage a 16035 Vineyard Blvd. Morgan Hill, CA 95037 Coating Dimensional Drawings - DIP Packages Package Dimensions DIP NN: No Port (Flat) 9.9 .390 0.3 .012 2.91 .114 8 7 6 6.24 .246 0.64 .025 5 12.8 .504 13.3 .524 6.99 .275 1 B Port High Pressure 2 3 1.14 .045 4 3.44 .135 2.54 .100 0.25 .010 7.62 .300 HNND Package 9.3 .366 0.64 .025 A Port Low Pressure 5.59 .220 9.31 .367 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. 0.46 .018 DIP AN: Barbed Top Port Gage 9.9 .390 0.3 .012 2.91 .114 8 7 6 3.5 .138 6.24 .246 4.93 .194 5 6.4 .252 12.8 .504 13.3 .524 6.99 .275 1.5 .059 1 2 3 1.14 .045 4 3.44 .135 0.25 .010 2.54 .100 B Port High Pressure 7.62 .300 9.3 .366 11.39 .448 A Port Low Pressure HAND Package 0.64 .025 9.31 .367 3.44 .135 8.39 .330 5.59 .220 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. 0.46 .018 DIP RN: Barbed Side Port Gage 9.9 .390 6.2 .244 13.3 .524 8 A Port Low Pressure HRND Package 5 12.8 .504 8.4 .331 1.57 .062 2.76 .109 1 1.38 .054 B Port High Pressure 6 9.9 .390 6.99 .275 0.25 .010 7 1.53 .060 1.93 .076 2.93 .115 2 3 7.62 .300 9.3 .366 4 1.14 .045 2.54 .100 0.64 .025 6.22 .245 0.46 .018 9.95 .392 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. * Refer to How to Order Tables for pinouts ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 24 of 34 Dimensional Drawings - DIP Packages (Cont'd) Package Dimensions 9.9 .390 2 3 4 1.14 .045 2.54 .100 7.62 .300 1.53 .060 9.3 .366 0.64 .025 1.93 .076 6.22 .245 2.93 .115 B Port High Pressure HRRD Package 12.8 .504 all sensors 1 1.38 .054 A Port Low Pressure 5 8.4 .331 1.57 .062 2.76 .109 0.25 .010 6 9.9 .390 6.99 .275 4 .157 7 9.95 .392 0.46 .018 DIP DR: Barbed Opposite Side Port Differential 9.9 .390 0.3 .012 2.91 .114 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. 8 7 6 6.16 .242 5 4.4 .173 A Port Low Pressure 1 4.4 .173 2 3 1.14 .045 4 2.76 .109 2.54 .100 15.76 .620 0.64 .025 1.53 .060 9.3 .366 6.22 .245 9.95 .392 0.25 .010 7.62 .300 B Port High Pressure HDRD Package 13.3 .524 6.99 .275 1.93 .076 3.78 .149 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. 1.38 .054 0.46 .018 DIP CN: Barbed Top Port 9.9 .390 0.3 .012 2.91 .114 2.7 .106 8 7 6 5 12.8 .504 6.99 .275 13.3 .524 1.5 .059 1 2 3 4 B Port High Pressure 1.14 .045 2.8 .110 2.54 .100 9.3 .366 A Port Low Pressure 0.25 .010 7.62 .300 6.1 .240 0.64 .025 9.95 .392 6.24 .246 3.4 .134 6.4 .252 HCND Package f 408 225 2079 12.8 .504 9.94 .391 3.44 .135 12.94 .509 4.23 .166 6.22 .245 0.46 .018 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. * Refer to How to Order Tables for pinouts All Sensors Table of Contents e www.allsensors.com 13.3 .524 8 DS-0376 Rev A Page 25 of 34 p 408 225 4314 6.16 .242 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 DIP RR: Barbed Side Port Differential Dimensional Drawings - DIP Packages (Cont'd) Package Dimensions DIP KN: Non Barbed Needle Top Port 9.9 .390 0.3 .012 2.91 .114 6.1 .240 8 7 6 5 6.24 .246 2.8 .110 6.4 .252 6.99 .275 12.8 .504 1 2 3 B Port High Pressure 9.3 .366 4 1.14 .045 2.8 .110 2.54 .100 13.64 .537 0.64 .025 9.95 .392 0.25 .010 7.62 .300 A Port Low Pressure HKND Package 13.3 .524 1.5 .059 3.44 .135 4.22 .166 6.22 .245 0.46 .018 8.14 .320 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-31. * Refer to How to Order Tables for pinouts ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 26 of 34 Dimensional Drawings - SMT Packages Package Dimensions SMT NN: No Port (Flat) 9.9 .390 6 6.24 .246 0.64 .025 5 12.8 .504 13.3 .524 6.99 .275 1 2 3 1.14 .045 4 B Port High Pressure 11.92 .469 2.8 .110 2.54 .100 all sensors 7 0.25 .010 7.62 .300 A Port Low Pressure Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-32. 4.73 .186 0.46 .018 1.27 .050 SMT AN: Barbed Top Port Gage 9.9 .390 0.3 .012 2.91 .114 8 7 6 3.5 .138 6.24 .246 4.93 .194 5 6.4 .252 12.8 .504 6.99 .275 1.5 .059 1 2 3 1.14 .045 4 B Port High Pressure 2.8 .110 2.54 .100 13.3 .524 11.92 .469 f 408 225 2079 HNNJ Package 9.3 .366 0.64 .025 0.25 .010 7.62 .300 9.3 .366 HANJ Package 11.39 .448 A Port Low Pressure 0.64 .025 8.39 .330 3.44 .135 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-32. 4.73 .186 1.27 .050 0.46 .018 SMT RN: Barbed Side Port Gage 9.9 .390 6.2 .244 13.3 .524 0.25 .010 B Port High Pressure A Port Low Pressure 7 6 5 9.9 .390 6.99 .275 11.92 .469 HRNJ Package 8 12.8 .504 8.4 .331 1 1.57 .062 2 3 2.76 .109 1.38 .054 1.53 .060 7.62 .300 9.3 .366 4 1.14 .045 2.54 .100 0.64 .025 1.93 .076 4.73 .186 2.93 .115 1.27 .050 0.46 .018 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-32. * Refer to How to Order Tables for pinouts All Sensors Table of Contents e www.allsensors.com 8 DS-0376 Rev A Page 27 of 34 p 408 225 4314 2.91 .114 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 0.3 .012 Dimensional Drawings - SMT Packages (Cont'd) Package Dimensions SMT RR: Barbed Side Port Differential B Port High Pressure 6.16 .242 3.78 .149 13.3 .524 A Port Low Pressure 11.92 .469 9.9 .390 8 1 2 3 2.76 .109 4 1.14 .045 9.3 .366 0.64 .025 1.93 .076 1.27 .050 0.46 .018 9.9 .390 0.3 .012 2.91 .114 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-32. 4.73 .186 2.93 .115 SMT DR: Barbed Opposite Side Port Differential 12.8 .504 2.54 .100 7.62 .300 1.38 .054 1.53 .060 HRRJ Package 5 8.4 .331 1.57 .062 0.25 .010 6 9.9 .390 6.99 .275 4 .157 7 8 7 6 6.16 .242 5 4.4 .173 12.8 .504 A Port Low Pressure 1 4.4 .173 2 3 1.14 .045 4 2.76 .109 0.25 .010 7.62 .300 15.76 .620 0.64 .025 1.53 .060 9.3 .366 4.83 .190 1.93 .076 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-32. 3.78 .149 1.27 .050 SMT KN: Non Barbed Needle Top Port 11.92 .469 2.54 .100 B Port High Pressure HDRJ Package 13.3 .524 6.99 .275 1.38 .054 0.46 .018 9.9 .390 0.3 .012 2.91 .114 6.1 .240 8 7 6 5 6.24 .246 2.8 .110 6.4 .252 6.99 .275 12.8 .504 1.5 .059 1 2 3 4 1.14 .045 2.8 .110 2.54 .100 B Port High Pressure 9.3 .366 13.3 .524 11.92 .469 0.25 .010 7.62 .300 13.64 .537 A Port Low Pressure HKNJ Package 0.64 .025 3.44 .135 4.73 .186 1.27 .050 4.22 .166 0.46 .018 8.14 .320 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-32. * Refer to How to Order Tables for pinouts ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 28 of 34 Dimensional Drawings - SIP H-Lead Packages Package Dimensions 9.9 .390 3 4 1.36 .054 1.14 .045 2.54 .100 0.51 .020 A Port Low Pressure 7.62 .300 SIP H-Lead AN: Barbed Top Port Gage 0.25 .010 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 9.9 .390 6.24 .246 2.8 .110 9.3 .366 0.3 .012 1.5 .059 2.96 .116 6.99 .275 1.1 .043 6.45 .254 1 2 3 0.64 .025 4 f 408 225 2079 10.5 .413 all sensors 2 10.17 .400 HNNH Package 6.99 .275 1.1 .043 1 0.64 .025 1.36 .054 10.17 .400 B Port High Pressure 7.62 .300 HANH Package 4.93 .194 A Port Low Pressure 3.5 .138 8.39 .330 SIP H-Lead AA: Barbed Top Port Differential 11.39 .448 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 9.9 .390 0.64 .025 1.5 .059 2.96 .116 10.5 .413 6.24 .246 2.8 .110 9.3 .366 0.3 .012 1.1 .043 6.45 .254 1 2 3 6.99 .275 4 1.36 .054 10.17 .400 0.51 .020 B Port High Pressure 7.62 .300 3.5 .138 0.25 .010 1.14 .045 2.54 .100 4.93 .194 HAAH Package 0.25 .010 1.14 .045 2.54 .100 0.51 .020 8.39 .330 11.39 .448 A Port Low Pressure 22.14 .872 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. * Refer to How to Order Tables for pinouts All Sensors Table of Contents e www.allsensors.com 0.64 .025 2.96 .116 10.5 .413 B Port High Pressure 6.24 .246 2.8 .110 9.3 .366 DS-0376 Rev A Page 29 of 34 p 408 225 4314 0.3 .012 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 SIP H-Lead NN: No Port (Flat) Dimensional Drawings - SIP H-Lead Packages (Cont'd) Package Dimensions SIP H-Lead RN: Barbed Side Port Gage 6.2 .244 9.9 .390 2.76 .109 1.57 .062 6.99 .275 8.45 .333 9.95 .392 1 2 4 3 1.1 .043 10.17 .400 1.36 .054 0.25 .010 B Port High Pressure HRNH Package 7.62 .300 1.38 .054 0.64 .025 2.93 .115 SIP H-Lead RR: Barbed Side Port Differential 6.16 .242 9.9 .390 2.76 .109 1.57 .062 6.99 .275 4 .157 8.45 .333 3.78 .149 9.95 .392 1 2 4 3 10.17 .400 0.25 .010 1.1 .043 1.14 .045 2.54 .100 7.62 .300 1.38 .054 1.53 .060 9.3 .366 0.64 .025 1.93 .076 B Port High Pressure 2.93 .115 SIP H-Lead DR: Barbed Opposite Side Port Differential 9.9 .390 0.3 .012 10.5 .413 1.36 .054 0.51 .020 A Port Low Pressure 2.21 .087 2.76 .109 9.3 .366 2.96 .116 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 6.16 .242 0.64 .025 6.99 .275 10.5 .413 4.45 .175 1 2 3 10.17 .400 B Port High Pressure 4 1.1 .043 1.36 .054 0.51 .020 7.62 .300 12.83 .505 A Port Low Pressure HDRH Package Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 1.93 .076 A Port Low Pressure HRRH Package 1.14 .045 2.54 .100 0.51 .020 1.53 .060 10.5 .413 0.25 .010 1.14 .045 2.54 .100 1.93 .076 3.78 .149 1.38 .054 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. * Refer to How to Order Tables for pinouts ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 30 of 34 Dimensional Drawings - SIL F-Lead Packages Package Dimensions SIL F-Lead NN: No Port (Flat) 9.9 .390 0.64 .025 2 3 4 0.46 .018 1.14 .045 2.54 .100 7.62 .300 0.25 .010 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. SIL F-Lead AN: Barbed Top Port Gage 9.9 .390 1.5 .059 2.96 .116 10.5 .413 6.45 .254 1 2 3 4 1.27 .050 15.12 .595 1.14 .045 2.54 .100 0.46 .018 7.62 .300 A Port Low Pressure 4.93 .194 HANF Package 3.5 .138 8.39 .330 SIL F-Lead AA: Barbed Top Port Differential 11.39 .448 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 1.1 .043 6.45 .254 1 2 3 6.99 .275 4 1.36 .054 10.17 .400 0.51 .020 7.62 .300 3.5 .138 HAAF Package 0.25 .010 1.14 .045 2.54 .100 4.93 .194 A Port Low Pressure 0.64 .025 1.5 .059 2.96 .116 B Port High Pressure 6.24 .246 2.8 .110 9.3 .366 1.72 .068 0.25 .010 9.9 .390 0.3 .012 0.64 .025 6.99 .275 1 .039 B Port High Pressure 10.5 .413 6.24 .246 2.8 .110 9.3 .366 0.3 .012 f 408 225 2079 HNNF Package 1.72 .068 1.27 .050 15.12 .595 all sensors 6.99 .275 1 .039 1 0.64 .025 8.39 .330 11.39 .448 22.14 .872 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. * Refer to How to Order Tables for pinouts All Sensors Table of Contents e www.allsensors.com 2.96 .116 A Port Low Pressure 6.24 .246 2.8 .110 9.3 .366 DS-0376 Rev A Page 31 of 34 p 408 225 4314 10.5 .413 0.3 .012 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 B Port High Pressure Dimensional Drawings - SIL F-Lead Packages (Cont'd) Package Dimensions SIL F-Lead RN: Barbed Side Port Gage 6.2 .244 9.9 .390 2.76 .109 1.57 .062 6.99 .275 9.95 .392 8.45 .333 1 1.72 .068 2 3 4 1 .039 1.27 .050 15.12 .595 0.46 .018 0.25 .010 HRNF Package 1.14 .045 2.54 .100 7.62 .300 1.38 .054 1.53 .060 B Port High Pressure 10.5 .413 9.3 .366 0.64 .025 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 1.93 .076 A Port Low Pressure 2.93 .115 SIL F-Lead RR: Barbed Side Port Differential 6.16 .242 9.9 .390 0.3 .012 10.5 .413 3.78 .149 2.76 .109 9.3 .366 2.96 .116 4.45 .175 2 3 1 .039 4 15.12 B Port High Pressure .595 1.72 .068 1.27 .050 0.46 .018 A Port Low Pressure 1.14 .045 2.54 .100 7.62 .300 12.83 .505 HRRF Package 0.25 .010 1.93 .076 1.38 .054 SIL F-Lead DR: Barbed Opposite Side Port Differential 9.9 .390 0.3 .012 9.3 .366 2.96 .116 6.16 .242 0.64 .025 6.99 .275 4.45 .175 1 HDRF Package Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. 2.21 .087 2.76 .109 10.5 .413 A Port Low Pressure 4 .157 6.99 .275 1 B Port High Pressure 0.64 .025 2 3 4 1 .039 1.72 .068 1.27 .050 15.12 .595 0.46 .018 7.62 .300 12.83 .505 1.14 .045 2.54 .100 0.25 .010 1.93 .076 3.78 .149 1.38 .054 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. * Refer to How to Order Tables for pinouts ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 32 of 34 Dimensional Drawings - SIL F-Lead Packages (Cont'd) Package Dimensions 6.1 .240 9.9 .390 2.8 .110 0.3 .012 10.5 .413 2.8 .110 1.5 .059 2.96 .116 1 2 3 4 1.72 .068 1.27 .050 15.12 .595 0.46 .018 B Port High Pressure 9.3 .366 7.62 .300 0.64 .025 6.99 .275 1 .039 6.45 .254 6.24 .246 all sensors SIL F-Lead KN: Non Barbed Needle Top Port 1.14 .045 2.54 .100 0.25 .010 A Port Low Pressure 3.44 .135 4.22 .166 8.24 .324 Notes: 1) Dimensions are in inches [mm]. 2) Pad Layout: PAD-1. All Sensors reserves the right to make changes to any products herein. All Sensors does not assume any liability arising out of the application or use of any product or circuit described herein, neither does it convey any license under its patent rights nor the rights of others. All Sensors Table of Contents DS-0376 Rev A Page 33 of 34 a 16035 Vineyard Blvd. Morgan Hill, CA 95037 p 408 225 4314 f 408 225 2079 * Refer to How to Order Tables for pinouts e www.allsensors.com 13.64 .537 HKNF Package Revisions Rev Date A 02/03/20 Change Description(s) Initial Release ELV Series - Digital and Analog Pressure Sensor Product Families Table of Contents Page 34 of 34
ELVH-001D-HNNH-C-N2A4 价格&库存

很抱歉,暂时无法提供与“ELVH-001D-HNNH-C-N2A4”相匹配的价格&库存,您可以联系我们找货

免费人工找货