0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SWI5-5-E-P6R

SWI5-5-E-P6R

  • 厂商:

    CUI

  • 封装:

  • 描述:

    AC/DC WALL MOUNT ADAPTER 5V 5W

  • 数据手册
  • 价格&库存
SWI5-5-E-P6R 数据手册
Additional Resources: Product Page | 3D Model date 04/24/2022 page 1 of 5 SERIES: SWI5-E │ DESCRIPTION: AC-DC POWER SUPPLY FEATURES • • • • • • • • • • up to 6 W continuous power CoC Tier 2 compliant universal input voltage range ultra-compact case no load power consumption < 0.075 W over current, over voltage, and short circuit protections CE safety approvals Class II construction IEC 62368 black and white case options MODEL input voltage input frequency output voltage output current output power ripple and noise1 range (Vac) range (Hz) nom (Vdc) max (A) max (W) max (mVp-p) average3 (%) 10% (%) typ (W) SWI5-5-E 90 ~ 264 47 ~ 63 5 1.0 5.0 300 74.9 66.2 0.05 SWI5-5B-E 90 ~ 264 47 ~ 63 5 1.2 6.0 300 75.2 72.0 0.06 SWI5-9-E 90 ~ 264 47 ~ 63 9 0.6 5.4 300 78.4 72.2 0.05 SWI5-12-E 90 ~ 264 47 ~ 63 12 0.5 6.0 300 80.9 72.9 0.06 Notes: efficiency level2 no load power consumption 1. At full load, nominal AC input voltage, 25°C, 20 MHz bandwidth oscilloscope, output terminated with 0.1 µF and 10 µF capacitors to ground. 2. CoC Tier 2 compliant. 3. Average efficiency is measured at 25%, 50%, 75%, and 100% load. PART NUMBER KEY SWI5 - XX - EX- XXX - CXX Reserved for Custom Configurations Base Number Output Voltage AC Input Type: Europe Case color: “Blank” = black W = white cui.com DC Plug Type: XXX = See output plug options on page 4 for more details Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI5-E │ DESCRIPTION: AC-DC POWER SUPPLY date 04/24/2022 │ page 2 of 5 INPUT parameter conditions/description min voltage typ 90 frequency 47 current at nominal input voltage leakage current at nominal input voltage & frequency no load power consumption at 115/230 Vac, 60/50 Hz max units 264 Vac 63 Hz 0.2 A 0.25 mA 0.075 W max units OUTPUT parameter conditions/description min typ line regulation ±5 load regulation ±5 start-up time hold-up time % % 3 at nominal input voltage & full load 5 s ms PROTECTIONS parameter conditions/description over voltage protection 5 Vdc output model 5 Vdc output B model 9 Vdc output model 12 Vdc output model min over current protection output shut down, auto recovery 5 Vdc output model 5 Vdc output B model 9 Vdc output model 12 Vdc output model typ max units 6.5 8.0 18.0 15.6 Vdc Vdc Vdc Vdc 1.8 2.4 1.2 0.9 A A A A max units short circuit protection SAFETY & COMPLIANCE parameter conditions/description min isolation voltage input to output at 10 mA for 1 minute safety approvals EN 62368 EMI/EMC CE MTBF as per Telcordia SR-332 (Issue 2), at 115/230 Vac, full load, 0°C~40°C RoHS 2011/65/EU typ 3,000 4,242 Vac Vdc 50,000 hours ENVIRONMENTAL parameter conditions/description min operating temperature storage temperature typ max units 0 40 °C -20 60 °C operating humidity non-condensing 20 85 % storage humidity non-condensing 5 95 % cui.com Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI5-E │ DESCRIPTION: AC-DC POWER SUPPLY date 04/24/2022 │ page 3 of 5 MECHANICAL parameter conditions/description dimensions 66 x 25 x 71.2 inlet plug Europe min typ max units mm weight 67 MECHANICAL DRAWING units: mm DC CORD units: mm Table 1 MODEL NO. CABLE CORD LENGTH SWI5-5-E UL2468, 24 AWG 1,500 mm ±50 SWI5-5B-E UL2468, 24 AWG 1,500 mm ±50 SWI5-9-E UL2468, 24 AWG 1,500 mm ±50 SWI5-12-E UL2468, 24 AWG 1,500 mm ±50 cui.com g Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI5-E │ DESCRIPTION: AC-DC POWER SUPPLY date 04/24/2022 │ page 4 of 5 DC PLUG TYPE PART NUMBER KEY XXX Plug Polarity: P = Center Positive Plug Code: X = Choose a code from the options below Plug Angle: “blank” = Straight R = Right Angle N = Center Negative Plug Polarity Code Dimensions (mm) Plug Angle Center Pos. Center Neg. Option Type A B C Straight Right ● ● 5 Standard 5.5 2.1 9.5 ● ● ● ● 6 Standard 5.5 2.5 9.5 ● ● ● ● 7 Standard 3.5 1.35 9.5 ● ● ● ● 8 Standard 3.8 1.35 9.5 ● ● ● ● 9 Standard 3.8 1.05 9.5 ● ● ● ● 10 Locking2 5.5 2.1 9.5 ● N/A ● ● 11 Locking2 5.5 2.5 9.5 ● N/A ● ● 12 EIAJ-1 2.35 0.7 9.5 ● ● ● ● 13 EIAJ-2 4.0 1.7 9.5 ● ● ● ● 14 EIAJ-3 4.75 1.7 9.5 ● ● N/A N/A ST N/A N/A N/A MUB ● N/A N/A USB Micro USB Type B 1. Contact CUI for additional plug options 2. Maximum insertion depth is 10mm Locking C A B B C Right Angle (R) C A C Straight Straight Right Angle (R) Stripped & Tinned USB 5.8±0.5 2.5±0.3 A B C EIAJ A A B Standard B Note: Stripped & Tinned P5(-) cui.com P1(+) Additional Resources: Product Page | 3D Model CUI Inc │ SERIES: SWI5-E │ DESCRIPTION: AC-DC POWER SUPPLY date 04/24/2022 │ page 5 of 5 REVISION HISTORY rev. description date 1.0 initial release 11/23/2016 1.01 features update, logo update 06/22/2020 1.02 model table updated 11/27/2020 1.03 safeties updated 12/11/2020 1.04 updated datasheet 08/09/2021 1.05 product image updated 08/20/2021 1.06 minimum current ratings updated 11/12/2021 dc plugs updated 04/24/2022 1.07 The revision history provided is for informational purposes only and is believed to be accurate. Headquarters 20050 SW 112th Ave. Tualatin, OR 97062 800.275.4899 Fax 503.612.2383 cui.com techsupport@cui.com This device complies with part 15 of the FCC Rules. Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. CUI offers a one (1) year limited warranty. Complete warranty information is listed on our website. CUI reserves the right to make changes to the product at any time without notice. Information provided by CUI is believed to be accurate and reliable. However, no responsibility is assumed by CUI for its use, nor for any infringements of patents or other rights of third parties which may result from its use. CUI products are not authorized or warranted for use as critical components in equipment that requires an extremely high level of reliability. A critical component is any component of a life support device or system whose failure to perform can be reasonably expected to cause the failure of the life support device or system, or to affect its safety or effectiveness.
SWI5-5-E-P6R 价格&库存

很抱歉,暂时无法提供与“SWI5-5-E-P6R”相匹配的价格&库存,您可以联系我们找货

免费人工找货