RH401

RH401

  • 厂商:

    EXTECH

  • 封装:

  • 描述:

    RH401 - Digital Psychrometer IR Thermometer - Extech Instruments Corporation.

  • 数据手册
  • 价格&库存
RH401 数据手册
User's Guide Digital Psychrometer + IR Thermometer Models RH401 and RH405 (kit) DP Wb C % Humi Introduction Congratulations on your purchase of the Extech RH401 Digital Psychrometer + InfraRed Thermometer. This device measures Humidity, Air Temperature, Dew Point and Wet Bulb. Advanced features include Infrared Non-Contact Surface Temperature Measurement, Data Hold and programmable Auto Power Off, and an RS-232 interface for capturing readings to a PC using optional 407752 software. The retractable probe protects the sensors when the meter is not in use. Careful use of this meter will provide years of reliable service. Meter Description 1. 2. 3. 4. 5. 6. 7. 8. 9. Emissivity adjust indicator Laser pointer on indicator Low Battery indicator IR Surface Temperature button ON/OFF/Setup button Back Light button Laser/Down button °F/°C/Up button Dew Point/Wet Bulb button 4 5 6 15 9 14 8 7 1 2 3 DP Wb 13 C % Humi 12 11 10 10. % Humidity display 11. Air Temperature, Dew Point or Wet Bulb display 12. IR Surface Temperature display 13. Extended probe with Humidity & Air Temperature Sensors 14. PC interface port 15. AC adaptor jack Note: The battery compartment is located on the rear of the instrument Warranty EXTECH INSTRUMENTS CORPORATION (A FLIR COMPANY) warrants this instrument to be free of defects in parts and workmanship for one year from date of shipment (a six month limited warranty applies to sensors and cables). If it should become necessary to return the instrument for service during or beyond the warranty period, contact the Customer Service Department at (781) 890-7440 ext. 210 for authorization or visit our website www.extech.com for contact information. A Return Authorization (RA) number must be issued before any product is returned to Extech. The sender is responsible for shipping charges, freight, insurance and proper packaging to prevent damage in transit. This warranty does not apply to defects resulting from action of the user such as misuse, improper wiring, operation outside of specification, improper maintenance or repair, or unauthorized modification. Extech specifically disclaims any implied warranties or merchantability or fitness for a specific purpose and will not be liable for any direct, indirect, incidental or consequential damages. Extech's total liability is limited to repair or replacement of the product. The warranty set forth above is inclusive and no other warranty, whether written or oral, is expressed or implied. 2 RH401 V1.5 8/08 Operation Retractable Humidity and Air Temperature Sensor Press down on the sensor, located at the top of the meter, to release it. Humidity and air temperature will not be displayed if the sensor is not extended. After use, press the sensor into the stored (protected) position. Power ON/OFF (or the button) to turn power on. The Press the meter will perform a short self-test when turned on. button for three seconds to turn power off. Press and hold the Humidity and Air Temperature measurements 1. Hold the meter in the area to be tested. 2. Allow adequate time for readings to stabilize. 3. View the Relative Humidity measurement in the lower display. 4. View the Air (probe)Temperature measurement in the middle display Wet Bulb and Dew Point measurements 1. To display the Dew Point measurement, press and hold the symbol DP appears in the middle display. 2. Dew Point temperature is now displayed. button until the Press Here Sensor Extended Sensor Stored button until the 3. To display the Wet Bulb measurement, press and hold the symbol Wb appears in the middle display . 4. Wet Bulb temperature is now displayed. 5. To display IR temp –DP temp (IR surface temperature-Dew Point), press and hold the button for more than 2 seconds then press the IR Temp button. The reading can now be viewed in the top display. 6. Press and hold the to IR temperature. button for more than 2 seconds to toggle the display back Non-Contact InfraRed Surface Temperature measurements 1. Point the meter toward the surface to be measured. button. 2. Press and hold the 3. View the temperature measurement in the upper display 4. Release the nd the reading will be held on the display until a new reading is taken. button, press the button to toggle the laser 5. While holding down the targeting pointer on/off. The symbol will appear in the middle left of the display indicating that surface temperature measurement is active and the laser pointer is on. WARNING! The Laser button enables/disables the Laser pointer. When button turns on the Laser beam. Avoid looking directly enabled, each press of the into the path of the Laser or pointing the Laser toward anyone’s eyes. Mirrored surfaces near a measurement object can redirect the Laser, use extreme caution. Do not allow the Laser beam to be directed toward explosive gases. 3 RH401 V1.5 8/08 IR Emissivity Adjustment Emissivity is adjustable from 0.3 to 0.99. The default value is 0.95 which is the typical emissivity value of many non-metallic surfaces. If the surface to be measured is highly reflective and the emissivity is not known, cover the surface with paint or tape to improve measurement accuracy. If the emissivity of the surface is known, follow this procedure to set the value. key twice to enter the Emissivity setting procedure. 1. With the meter on, Press the will flash on the top left side of the display. 2. Use the up key and the down key to adjust the value. 3. When the desired setting appears in the display, press again to save and return back to normal operation. Emissivity Factors for Common Materials Material under test Asphalt Concrete Cement Sand Soil Water Ice Snow Glass Ceramic Marble Plaster Mortar Brick Emissivity 0.90 to 0.98 0.94 0.96 0.90 0.92 to 0.96 0.92 to 0.96 0.96 to 0.98 0.83 0.90 to 0.95 0.90 to 0.94 0.94 0.80 to 0.90 0.89 to 0.91 0.93 to 0.96 Material under test Cloth (black) Skin (human) Lather Charcoal (powder) Lacquer Lacquer (matt) Rubber (black) Plastic Timber Paper Chromium Oxides Copper Oxides Iron Oxides Textiles Emissivity 0.98 0.98 0.75 to 0.80 0.96 0.80 to 0.95 0.97 0.94 0.85 to 0.95 0.90 0.70 to 0.94 0.81 0.78 0.78 to 0.82 0.90 Spot to Distance Ratio The 8:1 spot to distance ratio determines the size of the measured surface area with respect to the distance the meter is held away from the surface. 4 RH401 V1.5 8/08 Selecting temperature units of measure (C/F) o o Press and hold the C/ F button momentarily to toggle the temperature units. Automatic Power OFF The meter automatically shuts off after a programmed period of time. and . When “n” appears, To disable auto power off, with the meter off, press release the keys and the meter is now in Non-Sleep Mode. The power off time is adjustable from 5 to 600 seconds. To change the auto power off key to enter the setting procedure. Use the up key and the setting, press the down key to set the value. When the desired power-off time appears in the display, key again to save the parameters. press the Backlight Press the BKLT button to turn the display backlight on. The backlight will remain on until the BKLT button is pressed again or the meter is turned off. Error Messages An error message will appear on the display if the meter fails an internal diagnostic test. 1. E1 (Top display): IR temperature failure. Repair/replacement is necessary. 2. E2 (Top display): IR temperature >932°F (500°C). 3. E3 (Top display): IR temperature
RH401 价格&库存

很抱歉,暂时无法提供与“RH401”相匹配的价格&库存,您可以联系我们找货

免费人工找货