S URFACE MOUNT FUSES
WICKMANN
SMQ / No. 419
UL 248-14, 125V
125V,, F
Specifications
Time-Current Characteristic
Packaging Code and Info
Quick Acting (F)
000: Blister Tape/∅180mm Reel (1000 pcs.)
010: Blister Tape (5000 pcs.) contact WICKMANN
Standard
Materials
UL 248-14
CSA C22.2 No. 248.14
Housing:
Element:
Terminals:
Approvals
cULus Listed: File No. E 67006
cULus Recognized: File No. E 67006
Operating TTemperature
emperature
-65ºC to +125ºC (consider de-rating)
Features
Climatic Category
Heat resistant ceramic housing
For line or low voltage applications
Low voltage drop
Internationally approved
Dimensions (mm)
6,1 ±0,2
-40ºC/+85ºC/21 days (IEC 60068-2-1...3)
Stock Conditions
+10ºC to +60ºC
relative humidity ≤ 75% yearly average,
without dew, maximum value for 30 days-95%
max. 2,7
WebLinks
V ibration Resistance
Data Sheet - latest version
www.wickmannusa.com/products/419.pdf
Approval Certificates
1,45 -0,2
www.wickmannusa.com/approvals
1,45 -0,2
Soldering Heat Resistance
Packaging
260ºC, 10 sec. (IEC 60068-2-58)
www.wickmannusa.com/pack
Minimum Cross Section, Copper
For Application Information refer to
3,15 +0,05
2,95 +0,05
1,96 +0,05
235ºC, 3 sec. (IEC 60068-2-58)
www.wickmannusa.com/itcurves
Pad Layout
24 cycles at 15 min. each (IEC 60068-2-6)
10 - 60Hz at 0.75mm amplitude
60 - 2000Hz at 10g acceleration
Solderability
Time-Current Curve
Pad Size 2410
Ceramic
Wire
Copper alloy, tin plated
www.wickmannusa.com/download/fuseology.pdf
Wave &
Reflow
Conducting path - 0.1mm2
Path thickness - 0.035mm
Mounting
Avoid circuit traces below the fuse
Marking
1,96 +0,05
F, Current Rating
Unit Weight
0.23g (approx.)
Limits for Pre-arcing Time
2.0 x IRated
62mA ... 10.00A
< 60s
< 5s
Permissible continuous operating current is ≤ 7 0% at ambient temperature of 23ºC (73.4ºF).
Rated
Amp
Voltage
Breaking Voltage Drop Power Dissipation
Current
Code
Rating
Capacity
1.0 x IRated
1.0 x IRated
typ. (mV)
typ. (mW)
62mA
125mA
250mA
500mA
750mA
1.00A
1.50A
2.00A
2.50A
3.00A
4.00A
5.00A
7.00A
8.00A
10.00A
Order
Information
020709
0062
0125
0250
0500
0750
1100
1150
1200
1250
1300
1400
1500
1700
1800
2100
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
125V
Qty.
WebSite: www.wickmann.com
50A / 125VAC/DC
50-60Hz
cos ϕ = 1.0
35A / 125VAC
50-60Hz; cos ϕ = 1.0
100A / 125VDC
OrderNumber
1600
1300
950
360
350
210
250
180
220
160
140
130
130
110
100
Series
419
• Europe Tel: +49 (2302) 662-107
E-mail: sales@wickmann.com
Melting Integral
10 x IRated
max. (A2s)
typ. (A2s)
85
120
150
200
300
230
500
400
550
600
670
750
1200
1300
1400
Amp Code
0.00014
0.00085
0.0065
0.093
0.25
0.50
1.1
1.1
1.2
2.0
4.3
7.5
13.6
17.5
27
0.000095
0.00067
0.0052
0.074
0.20
0.42
0.95
0.90
0.95
1.7
3.42
6.8
11.6
13.8
23.5
Approvals
cURus
2.0 x IRated
cULus
Rated Current
•
•
•
•
•
•
•
•
•
•
•
•
•
•
•
Pack. Code
Specifications are subject to change without notice.
• Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk
SURFACE MOUNT FUSES
WICKMANN
00
0,0
10
SMQ / No. 419
I-t Characteristics
(Min-Max Limit)
0
,00
10
UL 248-14
Test value
0
1,0
0
10
Time (sec.)
0
10
1
0.1
1
0.0
01
0.0
1
1.5
2
3
4
5
6
7 8 9 10
15
I Fault / IRated
Contact WICKMANN for individual I-t curves
020709
WebSite: www.wickmann.com
• Europe Tel: +49 (2302) 662-107
E-mail: sales@wickmann.com
• Americas Tel: +1 (404) 699-7820
• Asia Tel: +852 26 14-1108
E-mail: service@wickmannusa.com E-mail: sales@wickmann.com.hk