HFA140NJ60D

HFA140NJ60D

  • 厂商:

    IRF

  • 封装:

  • 描述:

    HFA140NJ60D - Ultrafast, Soft Recovery Diode - International Rectifier

  • 数据手册
  • 价格&库存
HFA140NJ60D 数据手册
PD -2.514 rev. A 02/99 HFA140NJ60D HEXFRED Features • Reduced RFI and EMI • Reduced Snubbing • Extensive Characterization of Recovery Parameters TM Ultrafast, Soft Recovery Diode Anode 1 Cathode 2 Base AC VR = 600V VF(typ.)ƒ = 1.2V IF(AV) = 140A Qrr (typ.) = 340nC IRRM (typ.) = 8.5A trr(typ.) = 33ns di(rec)M/dt (typ.)ƒ = 220A/µs Description HEXFRED diodes are optimized to reduce losses and EMI/RFI in high frequency power conditioning systems. An extensive characterization of the recovery behavior for different values of current, temperature and di/dt simplifies the calculations of losses in the operating conditions. The softness of the recovery eliminates the need for a snubber in most applications. These devices are ideally suited for power converters, motors drives and other applications where switching losses are significant portion of the total losses. TM TO-244AB Absolute Maximum Ratings (per Leg) Parameter VR IF @ TC = 25°C IF @ TC = 100°C IFSM EAS PD @ TC = 25°C PD @ TC = 100°C TJ TSTG Cathode-to-Anode Voltage Continuous Forward Current Continuous Forward Current Single Pulse Forward Current  Non-Repetitive Avalanche Energy ‚ Maximum Power Dissipation Maximum Power Dissipation Operating Junction and Storage Temperature Range Max. 600 126 63 400 220 310 125 -55 to +150 Units V A µJ W C Thermal - Mechanical Characteristics Parameter RthJC RthCS Wt Junction-to-Case, Single Leg Conducting Junction-to-Case, Both Legs Conducting Case-to-Sink, Flat, Greased Surface Weight Mounting Torque „ Mounting Torque Center Hole Terminal Torque Vertical Pull 2 inch Lever Pull Min. –––– –––– –––– –––– 30 (3.4) 12 (1.4) 30 (3.4) –––– –––– Typ. –––– –––– 0.10 79 (2.8) –––– –––– –––– –––– –––– Max. 0.48 0.24 –––– –––– 40 (4.6) 18 (2.1) 40 (4.6) 80 35 Units °C/W K/W g (oz) lbf•in (N•m) lbf•in Note:  Limited by junction temperature ‚ L = 100µH, duty cycle limited by max TJ ƒ 125°C „ Mounting surface must be smooth, flat, free or burrs or other protrusions. Apply a thin even film or thermal grease to mounting surface. Gradually tighten each mounting bolt in 5-10 lbf•in steps until desired or maximum torque limits are reached. Module 1 HFA140NJ60D PD-2.514 rev. A 02/99 Electrical Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified) Parameter VBR V FM Cathode Anode Breakdown Voltage Max Forward Voltage Min. Typ. Max. Units 600 ––– ––– ––– ––– ––– ––– ––– ––– 1.3 1.5 1.2 4.0 1.0 140 7.0 ––– 1.5 1.7 1.4 20 4.0 250 ––– V V µA mA pF nH Test Conditions IR = 100µA IF = 70A IF = 140A See Fig. 1 IF = 70A, T J = 125°C VR = VR Rated See Fig. 2 TJ = 125°C, VR = 480V VR = 200V See Fig. 3 From top of terminal hole to mounting plane IRM CT LS Max Reverse Leakage Current Junction Capacitance Series Inductance Dynamic Recovery Characteristics (per Leg) @ TJ = 25°C (unless otherwise specified) Parameter trr trr1 trr2 IRRM1 IRRM2 Qrr1 Qrr2 di(rec)M /dt1 di(rec)M /dt2 Reverse Recovery Time Min. Typ. Max. Units ––– ––– ––– ––– ––– ––– ––– ––– ––– Test Conditions Peak Recovery Current Reverse Recovery Charge Peak Rate of Fall of Recovery Current During tb 33 ––– IF = 1.0A, dif/dt = 200A/µs, V R = 30V 80 120 ns TJ = 25°C 140 220 TJ = 125°C IF = 70A 8.5 15 TJ = 25°C A 14 25 TJ = 125°C VR = 200V 340 900 TJ = 25°C nC 980 2300 TJ = 125°C dif/dt = 200A/µs 300 ––– TJ = 25°C A/µs 220 ––– TJ = 125°C 80.01 (3.150) 40.26 (1.585) 39.75 (1.565) 2 10.41 (0.410) DIA. 9.65 (0.380) 20.32 (0.800) 17.78 (0.700) 7.49 (0.295) DIA. 6.99 (0.275) (2 PLCS.) LEAD ASSIGNMENTS 1 - ANODE 2 - CATHODE 3 - ANODE 34.925 (1.375) REF. 4.95 (0.195) DIA. 4.70 (0.185) 1/4-20 SLOTTED HEX 63.50 (2.500) 60.96 (2.400) 1 3 23.55 (0.927) 20.42 (0.804) 15.75 (0.620) 14.99 (0.590) 3.35 (0.132) CONFORMS TO JEDEC OUTLINE TO-244AB Dimensions in Millimeters and (Inches) 92.71 (3.650) 90.17 (3.550) 3.02 (0.119) 2 HFA140NJ60D PD-2.514 rev. A 02/99 1000 10000 Reverse Current - I R (µA) T = 150 °C J 1000 Instantaneous Forward Current - I F (A) 100 T = 125°C J 10 100 TJ = 150°C TJ = 125°C TJ = 25°C 1 TJ = 25°C 0.1 0 200 400 600 Junction Capacitance - C T (pF) 10 Fig. 2 - Typical Reverse Current vs. Reverse Voltage, (per Leg) 10000 Reverse Voltage - VR (V) A 1000 TJ = 25 °C 1 0.0 100 1.0 2.0 3.0 Forward Voltage Drop - V FM (V) Fig. 1 - Maximum Forward Voltage Drop vs. Instantaneous Forward Current, (per Leg) 10 1 10 100 1000 Reverse Voltage - VR (V) Fig. 3 - Typical Junction Capacitance vs. Reverse Voltage, (per Leg) 1 Thermal Impedance - Z thJC (K/W) 0.1 D = 0.50 D = 0.33 D = 0.25 D = 0.17 D = 0.08 P DM t 0.01 S ingle Pulse (Thermal Resistance) 2 Notes: 1. Duty factor D = t / t 12 1 t 2. Peak T = PDM x Z thJC + T J C 0.0001 0.001 0.01 0.1 1 10 100 0.001 0.00001 t 1 , Rectangular Pulse Duration (Seconds) Fig. 4 - Maximum Thermal Impedance Zthjc Characteristics, (per Leg) 3 HFA140NJ60D PD-2.514 rev. A 02/99 250 100 VR = 200V TJ = 125°C TJ = 25°C 200 VR = 200V TJ = 125°C TJ = 25°C I F = 140A t rr - (ns) 150 I IRRM - (A) I F = 70A I F = 30A 10 I F = 140A 100 I F = 70A IF = 30A 50 0 100 di f /dt - (A/µs) 1000 1 100 di f /dt - (A/µs) 1000 Fig. 5 - Typical Reverse Recovery vs. dif/dt, (per Leg) 4000 Fig. 6 - Typical Recovery Current vs. dif/dt, (per Leg) 10000 VR = 200V TJ = 125 °C TJ = 25°C 3000 VR = 200V TJ = 125°C TJ = 25°C I F = 140A 2000 di(rec)M/dt - (A/µs) Q RR - (nC) IF = 30A 1000 I F = 70A I F = 30A 1000 IF = 70A IF =140A 0 100 di f /dt - (A/µs) 1000 100 100 di f /dt - (A/µs) 1000 Fig. 7 - Typical Stored Charge vs. dif/dt, (per Leg) 4 Fig. 8 - Typical di(rec)M/dt vs. dif/dt, (per Leg) HFA140NJ60D PD-2.514 rev. A 02/99 3 IF t rr ta tb 4 REVERSE RECOVERY CIRCUIT VR = 200V 0 Q rr I RRM 2 0.5 I RRM di(rec)M/dt 0.75 I RRM 5 0.01 Ω L = 70µH D.U.T. D IRFP250 S 1 di f /dt 4. Qrr - Area under curve defined by trr and IRRM trr X IRRM Qrr = 2 5. di(rec)M/dt - Peak rate of change of current during tb portion of trr dif/dt ADJUST G 1. dif /dt - Rate of change of current through zero crossing 2. IRRM - Peak reverse recovery current 3. trr - Reverse recovery time measured from zero crossing point of negative going IF to point where a line passing through 0.75 IRRM and 0.50 IRRM extrapolated to zero current Fig. 9 - Reverse Recovery Parameter Test Circuit L = 100µH HIGH-SPEED SWITCH Rg = 25 ohm CURRENT MONITOR FREE-WHEEL DIODE + Vd = 50V Fig. 10 - Reverse Recovery Waveform and Definitions I L(PK) DUT DECAY TIME V (AVAL) V R(RATED) Fig. 11 - Avalanche Test Circuit and Waveforms WORLD HEADQUARTERS: EUROPEAN HEADQUARTERS: IR CANADA: IR GERMANY: IR ITALY: IR FAR EAST: IR SOUTHEAST ASIA: IR TAIWAN: 233 Kansas St., El Segundo, California 90245 U.S.A. Tel: (310) 322 3331. Fax: (310) 322 3332. Hurst Green, Oxted, Surrey RH8 9BB, U.K. Tel: ++ 44 1883 732020. Fax: ++ 44 1883 733408. 15 Lincoln Court, Brampton, Markham, Ontario L6T3Z2. Tel: (905) 453 2200. Fax: (905) 475 8801. Saalburgstrasse 157, 61350 Bad Homburg. Tel: ++ 49 6172 96590. Fax: ++ 49 6172 965933. Via Liguria 49, 10071 Borgaro, Torino. Tel: ++ 39 11 4510111. Fax: ++ 39 11 4510220. K&H Bldg., 2F, 30-4 Nishi-Ikebukuro 3-Chome, Toshima-Ku, Tokyo, Japan 171. Tel: 81 3 3983 0086. 1 Kim Seng Promenade, Great World City West Tower,13-11, Singapore 237994. Tel: ++ 65 838 4630. 16 Fl. Suite D.207, Sec. 2, Tun Haw South Road, Taipei, 10673, Taiwan. Tel: 886 2 2377 9936. http://www.irf.com Fax-On-Demand: +44 1883 733420 Data and specifications subject to change without notice. 5
HFA140NJ60D 价格&库存

很抱歉,暂时无法提供与“HFA140NJ60D”相匹配的价格&库存,您可以联系我们找货

免费人工找货