0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
MPA150X-24Z

MPA150X-24Z

  • 厂商:

    MPD

  • 封装:

  • 描述:

    MPA150X-24Z - Compact 1U 150W Single Output Power Factor Corrected AC/DC Power Supplies - MicroPower...

  • 数据手册
  • 价格&库存
MPA150X-24Z 数据手册
MPA150 Series Compact 1U 150W Single Output Power Factor Corrected AC/DC Power Supplies Key Features: • Compact 1U 150W Supply • PFC to EN61000-3-2 “A” • UL, cUL, TUV Approvals • CE Certified • FCC Class B Emissions • 3 - 56 V Output Voltages • Auto Selectable AC Input • 600W Peak Power • Four Mechanical Options Only 5 x 3.2 x 1.5 in!! Conditions Autoranging Min. 90 180 47 Typ. Max. 132 264 63 Units VAC Hz A 35 70 A mA Electrical Specifications Specifications typical @ +25°C, nominal input voltage & rated output current, unless otherwise noted. Specifications subject to change without notice notice. Input Parameter Input Voltage Range Input Frequency Input Current, Full Load Inrush Current, Cold Start Leakage Current Power Factor Correction Input Protection 110 - 120 VAC 4 200 - 240 VAC 2 110 VAC 220 VAC 240 VAC 1.5 Meets EN61000-3-2 Class A T4A/250V Fuse Conditions Min. Output Parameter Output Voltage Adjustment Output Regulation (Note 1) Hold Time Ripple & Noise (20 MHz) (Note 2) Overload Protection Over Voltage Protection Over Temperature Protection Temperature Coefficient Transient Recovery Time (Note 3) Transient Response Deviation Overshoot/Undershoot Turn On Delay Output Short Circuit Typ. Max. ±5.0 ±1.0 110 VAC, 80% Load 20 See Model Selection Guide Foldback with Autorecovery 110 140 >130% of Rated Output Voltage. Recycle AC Input. >+85ºC Ambient with Autorecovery ±0.04 2.5 50% Load Change 5 At Turn On/Off ±5.0 120 VAC 1 Continuous With Autorecovery By Trim Pot Conditions Input - Output Input - FG (Frame Ground) Primary - Core Fixed Min. 3,000 1,500 1,500 Typ. Max. Units % % mSec % %/ºC mS % % S General Parameter Isolation Voltage (Note 4) Units VAC 25 kHz MicroPower Direct Interface Signals 292 Page Street Suite D Stoughton, MA 02072 USA Power Supply On Switching Frequency Power Good Signal Remote On/Off Green LED (LED1) on the PCB PG on CN1. Goes TTL high 100 to 500 mS after regulation. Goes low at least 1 mS before the loss of regulation. Will sink 100 mA. RMSW on CN1. A TTL low signal inhibits the output. Hiccup Mode Conditions Min. Typ. Max. Ambient 0 +25 +50 2.5%/ ºC from +50 ºC to + 70 ºC -20 +85 See Model Selection Guide RH, Non-condensing 90 Units ºC ºC % T: (781) 344-8226 F: (781) 344-8481 E: sales@micropowerdirect.com W: www.micropowerdirect.com Environmental Parameter Operating Temperature Range Output Derating Storage Temperature Range Cooling Operating Humidity Reliability Specifications Parameter MTBF Safety Standards EEMI Compliance EMS Immunity Compliance Conditions Min. Typ. Max. Units MIL HDBK 217F, 30ºC, Gnd Benign 100 kHours UL 60950; CSA C22.2 No. 60950; TUV EN60950; CB Report (IEC 60950) Compliance to EN55022 (CISPR22) Class B; EN61000-3-2,3 EN6100-4-2,3,4,5,6,8,11; EN55024,; CE Marked (LVD) Model Selection Guide Model Number MPA150x-03z MPA150x-05z MPA150x-12z MPA150x-18z MPA150x-24z MPA150x-48z Output Voltage Factory Range PreSet 3.3 VDC 3.0 - 4.0 VDC 5 VDC 5.0 - 6.0 VDC 12 VDC 12.0 - 16.0 VDC 18 VDC 17.0 - 23.0 VDC 24 VDC 24.0 - 30.0 VDC 48 VDC 35.0 - 56.0 VDC Max. Output Current (Note 5,6,7) 16 CFM Convection Min. (U/w Air, F) (U) Ripple & Noise 50 mV p-p 50 mV p-p ±1% p-p ±1% p-p ±1% p-p ±1% p-p Efficiency (Note 7) Input Connector CN3: Mating Molex Part No. 09-91-0500 (5 pin, 3 used) or Howder Terminal Block No. HD-603-3P (3-pin) or equivalent. Output Connector CN2: Mating Molex Part No. 09-91-0600 (6 pin) or Howder Terminal Block No. HD-601-4P (4-pin) or equivalent. Output Pin Assignment: Howder Pins 1 ~ 2: V+ Pins 3 ~ 4: VMolex Pins 1 ~ 3: V+ Pins 4 ~ 6: V- 30.00A 30.00A 12.50A 8.33A 6.25A 3.12A 20.00A 20.00A 8.33A 5.55A 4.16A 2.08A 0.0A 0.0A 0.0A 0.0A 0.0A 0.0A 70% 75% 80% 83% 83% 83% Notes: 1. Output regulation includes line & load. 2. Ripple & noise is measured from 10 Hz to 20 MHz. Measurement connection to the unit is made with a 0.1 µF ceramic capacitor & a 22 µF electrolytic capacitor connected in parallel. 3. Transient recovery is measured to within a 1% error band for a load step change of 50% to 100%. 4. Isolation specifications are production HI-Pot tested for 3 seconds. 5. The full output range (see table above) is covered in the safety agency certification. Standard models are factory set to the “Preset” voltage. This may be set to other levels within the range without affecting the agency certification. For more information, contact the factory. 6. Units will provide peak power of 600W for 500 µS. For units capable of longer durations, contact the factory. 7. A 1% minimum load is required to maintain regulation and ripple specifications. Logic Signal Connector CN1: Mating JST XHP-3 or equivalent (CHYAO SHIUNN JS-2001-03). Fan driver connector (FAN): 12 VDC / 300 mA is available to drive an external fan. Mating JST XHP-2 or equivalent (CHYAO SHIUNN JS-2001-02). Mechanical Dimensions: U-Chassis (U Suffix) U-Chassis Cover (C Suffix) U-Chassis Cover/W Fan (F Suffix) U-Chassis Alternate Cover (B Suffix) MicroPower Direct www.micropowerdirect.com • 292 Page Street Ste D Stoughton, MA 02072 TEL: (781) 344-8226 • FAX: (781) 344-8481 • E-Mail: sales@micropowerdirect.com
MPA150X-24Z 价格&库存

很抱歉,暂时无法提供与“MPA150X-24Z”相匹配的价格&库存,您可以联系我们找货

免费人工找货