HPR1XXVC
www.murata-ps.com
0.75 Watt Single Output DC/DC Converter
Discontinued
HPR1XXVC Series. The high efficiency of the
HPR1XXVC Series means less internal power
dissipation, as low as 190mW.
With reduced heat dissipation the HPR1XXVC
Series can operate at higher temperatures with
no degradation. In addition, the high efficiency
of the HPR1XXVC Series means the series is
able to offer greater than 10 W/inch3 of output
power density. Operation down
to no load will not impact the reliability
The HPR1XXVC Series uses advanced circuit
design and packaging technol‑
ogy to deliver superior reliability and perfor‑
mance. A 170kHz push-pull
oscillator is used in the input stage. Beatfrequency oscillation problems are reduced
when using the HPR1XXVC Series with high
frequency isolation amplifiers.
Reduced parts count and high
efficiency add to the reliability of the
of the series, although a >1mA minimum load
is needed to realize published
specifications.
The HPR1XXVC Series provides the user a
low cost converter without sacrificing reliabil‑
ity. The use of surface mounted devices and
advanced manufacturing technologies make
it possible to offer premium performance and
low cost.
SPECIFICATIONS All specifications are typical at TA = +25°C nominal input voltage unless otherwise specified.
PRODUCT SELECTION CHART
Nominal
Input
Voltage
VDC
Rated
Output
Voltage
VDC
Rated
Output
Current
mA
HPR117VC
15
±15
±25
8
63
5
79
MEA1D1515DC
HPR100VC
HPR105VC
HPR101VC
HPR102VC
HPR103VC
HPR104VC
HPR106VC
HPR107VC
HPR108VC
HPR109VC
HPR110VC
HPR111VC
HPR112VC
HPR113VC
HPR114VC
HPR115VC
HPR116VC
HPR118VC
HPR119VC
HPR120VC
HPR121VC
HPR122VC
HPR123VC
5
5
5
5
5
5
12
12
12
12
12
12
15
15
15
15
15
24
24
24
24
24
24
5
±15
12
15
±5
±12
5
12
15
±5
±12
±15
5
12
15
±5
±12
5
12
15
±5
±12
±15
150
±25
62
50
±72
±30
150
62
50
±72
±30
±25
150
62
50
±72
±30
150
62
50
±72
±30
±25
20
20
20
20
20
20
10
10
10
10
10
10
8
8
8
8
8
8
8
8
8
8
8
216
200
212
212
218
212
90
81
81
88
81
81
72
72
72
72
63
48
48
45
45
45
45
10
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
5
15
15
15
15
15
15
69
75
70
71
68
68
69
77
77
71
74
77
69
69
69
69
76
65
65
76
69
67
69
NKE0505DC / NME0505DC
NMA0515DC / MEA1D0515DC
NKE0512DC / NME0512DC
NKE0515DC / NME0515DC
NMA0505DC / MEA1D0505DC
NMA0512DC / MEA1D0512DC
NKE1205DC / NME1205DC
NKE1212DC / NME1212DC
NKE1215DC / NME1215DC
NMA1205DC / MEA1D1205DC
NMA1212DC / MEA1D1212DC
NMA1215DC / MEA1D1215DC
MEV1S1505DC
MEV1S1512DC
MEV1S1515DC
MEA1D1505DC
MEA1D1512DC
NME2405DC / MEV1S2405DC
NME2412DC / MEV1S2412DC
NME2412DC / MEV1S2415DC
MEA1D2405DC
MEA1D2412DC
MEA1D2415DC
Model
Discontinued
For full details go to
www.murata-ps.com/rohs
Input Current
Reflected
Efficiency
Rated Load
Ripple Current
No Load
Typ.
mA
mAp-p
%
Recommended Alternatives
*
www.murata-ps.com/support
TDC_HPR1XXVC.D03 Page 1 of 4
HPR1XXVC
0.75 Watt Single Output DC/DC Converter
SPECIFICATIONS, ALL MODELS
GENERAL
OUTPUT
INPUT
Specifications are at TA = +25°C nominal input voltage unless otherwise specified.
PARAMETER
CONDITIONS
MIN
TYP
MAX
UNITS
INPUT
Voltage Range
4.5
5
5.5
VDC
10.8
12
13.2
VDC
13.5
15
16.5
VDC
21.6
24
26.4
VDC
Voltage Rise Time See Typical Performance Curves & Application Notes: “Capacitive Loading Effects on Start-Up of DC/DC Converters”
OUTPUT
Rated Power
750
mW
Voltage Setpoint Accuracy
Rated Load, Nominal VIN
±5
%
Ripple & Noise
BW = DC to 10MHz
150
200
mVp-p
BW =10Hz to 2MHz
30
40
mVrms
Voltage (Over Input Voltage Range) 1mA to Rated Current, VOUT = 5V
4.75
7
VDC
1mA to Rated Current, VOUT = 12V
11.40
15
VDC
1mA to Rated Current, VOUT = 15V
14.25
18
VDC
Temperature Coefficent
.01
.05
%/ °C
REGULATION
Load Regulation (All other modes) Rated Load to 1mA Load
3
%
GENERAL
ISOLATION
Rated Voltage
750
VDC
Test Voltage
60 Hz, 10 Seconds
750
Vrms
Resistance
10
GW
Capacitance
25
100
pF
Leakage Current
VISO= 240VAC, 60Hz
2
8.5
mArms
Switching Frequency
170
kHz
Frequency Change
Over Line and Load
24
%
Package Weight
3
g
MTTF per MIL-HDBK-217, Rev. F*
Circuit Stress Method
Ground Benign
TA = +25°C
7.9
MHr
Fixed Ground
TA = +35°C
1.9
MHr
Naval Sheltered
TA = +35°C
1.2
MHr
Airborne Uninhabited Fighter
TA = +35°C
300
kHr
TEMPERATURE
Specification
-25
+25
+85
°C
Operation
-40
+100
°C
Storage
-40
+110
°C
SOLDERING INFORMATION
The HPR1XXVC devices are intended for wave soldering or manual soldering.
They are not intended to be subject to surface mount processes under any circumstances.
The normal wave soldering process can be used with these devices where the device is subjected
to a maximum wave temperature of 260°C for a period of no more than 10 seconds. Within this
time and temperature range, the integrity of the device’s plastic body will not be compromised and
internal temperatures within the converter will not exceed 175°C. Care should be taken to control
manual soldering limits identical to that of wave soldering.
www.murata-ps.com/support
TDC_HPR1XXVC.D03 Page 2 of 4
HPR1XXVC
0.75 Watt Single Output DC/DC Converter
TYPICAL PERFORMANCE CURVES
Specifications are at TA = +25°C nominal input voltage and nominal load.
VOUT VS LOAD
(5Vout Models)
VOUT VS LOAD
(±5Vout Models)
5.7
5.4
5.5
5.2
VOUT VS LOAD
(12Vout Models)
12.5
5.3
5.0
5.1
4.8
4.9
4.6
0
80
40
120
12.3
Vout
Vout
Vout
12.4
160
12.1
12.0
0
20
Output Current (mA)
12.3
15.3
12.1
15.1
12.0
14.9
10
20
20
30
40
80
60
16.0
15.5
15.0
14.5
14.0
0
20
40
60
13.5
80
Output Current each load (mA)
Output Current each load (mA)
EFFICIENCY VS LOAD
OSCILLATION FREQUENCY VS
TEMPERATURE
90
40
VOUT VS LOAD
(±15Vout Models)
16.5
15.5
12.2
0
0
Output Current each load (mA)
Vout
Vout
Vout
11.9
80
15.7
12.4
0.2
0
0.4
0.6
0.8
1.0
Output Power each load (Watts)
220
Frequency (KHz)
75
Efficiency (%)
60
VOUT VS LOAD
(15Vout Models)
15.9
12.5
60
45
30
15
0
40
Output Current each load (mA)
VOUT VS LOAD
(±12Vout Models)
12.6
12.2
0
20
60
40
80
200
180
160
140
100
-30
0
% of Rated Load (%)
30
60
90
Temperature (°C)
SAFE OPERATING AREA
LOAD CAPACITANCE vs INPUT RISE TIME
(5 Vout models)
600
50
Total Load Capacitance (uF)
Total Load Capacitance (uF)
500
400
300
SAFE OPERATING AREA
200
40
30
SAFE OPERATING AREA
20
10
100
0
0
0
5
10
15
20
25
30
35
Rise Time of Input Voltage (mS)
40
45
50
LOAD CAPACITANCE vs INPUT RISE TIME
(12 Vout models)
90
Total Load Capacitance (uF)
LOAD CAPACITANCE vs INPUT RISE TIME
(15 Vout models)
60
60
50
SAFE OPERATING AREA
30
20
10
0
5
10
15
20
25
30
35
40
10
15
20
25
30
35
40
45
50
Rise Time of Input Voltage (mS)
1.) When operated within the SAFE OPERATING AREA as defined
by the above curves, the output voltage of HPR1XXC devices is
guaranteed to be within 95% of its steady-state value within 100
milliseconds after the input voltage has reached 95% of its steady-
state value.
70
0
5
NOTES:
80
40
0
45
50
2.) For dual output models, total load capacitance is the sum of the
capacitances on the plus and minus outputs.
Rise Time of Input Voltage (mS)
www.murata-ps.com/support
TDC_HPR1XXVC.D03 Page 3 of 4
HPR1XXVC
0.75 Watt Single Output DC/DC Converter
MECHANICAL
PACKAGE/PINOUT “V”
DIP PACKAGE
0.785±0.010"
(19.94±0.25)
14 13
TOP VIEW
11 10 9 8
0.695±0.015"
(17.65±0.38)
0.525±0.010"
(13.34±0.25)
1 2 3 4 5 6 7
0.375±0.005"
(9.52±0.13)
0.015±0.005"
(0.38±0.13)
SIDE VIEW
0.020±0.002"
(0.51±0.05)
0.100±0.010"
(2.54±0.25)
0°-15°
0.600"
(15.24)
PIN CONNECTIONS
PIN#
1
2
3
4
5
6
SINGLES
DUALS
PIN#
SINGLES
+VIN +VIN
7
-VIN -VIN 8
NC NC 9
NC NC
10
-VOUT -VOUT
11
NC Common 13
14
DUALS
+VOUT +VOUT
NC NC
NC NC
NC
NC
NC
NC
NC
NC
NC
NC
ABSOLUTE MAXIMUM RATINGS
Internal Power Dissipation......................................... 450mW
Short Circuit Duration................................................. Momentary
0.125+0.030"
-0.000"
(3.18+0.76) BOTTOM
(
-0.00)
VIEW
NOTES:
NC = Do Not Connect.
Duplicate pin functions are internally connected.
All dimensions are in inches (millimeters).
GRID: 0.100 inches (2.54 millimeters)
MATERIAL: Lead material is phosphor bronze; lead
finish is 100-300 microinches of matte tin over a
nickel barrier layer of 5-40 microinches.
ORDERING INFORMATION
HPR 1XX V
Device Family
HPR Indicates DC/DC Converter
Model Number
Selected from Table of Electrical Characteristics
C
Package Option
V = DIP Package
RoHS Compliant Version
Murata Power Solutions, Inc.
11 Cabot Boulevard, Mansfield, MA 02048-1151 U.S.A.
ISO 9001 and 14001 REGISTERED
This product is subject to the following operating requirements
and the Life and Safety Critical Application Sales Policy:
Refer to: http://www.murata-ps.com/requirements/
Murata Power Solutions, Inc. makes no representation that the use of its products in the circuits described herein, or the use of
other technical information contained herein, will not infringe upon existing or future patent rights. The descriptions contained herein do
not imply the granting of licenses to make, use, or sell equipment constructed in accordance therewith. Specifications are subject to
change without notice.
2017 Murata Power Solutions, Inc.
www.murata-ps.com/support
TDC_HPR1XXVC.D03 Page 4 of 4
很抱歉,暂时无法提供与“HPR117VC”相匹配的价格&库存,您可以联系我们找货
免费人工找货