0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DP5-C

DP5-C

  • 厂商:

    NAIS(松下)

  • 封装:

    -

  • 描述:

    PROCESS METER 0-1MPA LCD PNL MT

  • 数据手册
  • 价格&库存
DP5-C 数据手册
DP5-01.htm 1/1,000 sec. The advantage of the fastest response in the industry High speed in response to the needs of the times. Achieves 1 ms response time, the fastest in the industry. file:///G|/DP5/DP5-forweb.htm (1 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm In response to the needs of the times and amid the continuing quest for faster and more efficient production lines comes the DP5/DPH series, a digital pressure sensor with a detachable head. The response time of 1 ms makes this the fastest sensor in the industry. In addition to the fast response time, the detachable head represents a major breakthough for ease of operation and maintenance. Independent Use of Sensor Head Possible Data can be controlled by taking the analog voltage output (1 to 5V) from the sensor head and sending it to a digital panel meter. Extremely Small, Extremely Light Head (6g) Sensor Head with Operation Indicator The sensor head is also equipped with an operation indicator. Output ON/OFF can be checked at the sensor head and operation can be checked at the suction head. (Linked to Comparative Output 1) Convenient Intermediate Cable An intermediate cable with connectors for connecting the sensor head and the controller makes operation and maintenance easier. ● Standard or flexible intermediate cables are available in 2m, 3m and 5m sizes. ● Use the flexible intermediate cable when the sensor head is attached to moving sections. file:///G|/DP5/DP5-forweb.htm (2 of 20) [6/11/2001 11:14:04 AM] Easy Mounting, Mobile Pressure Port The head's pressure port can be rotated independently (freeturning) from the sensor head. In addition to being easy to mount, the cable can be positioned in any direction. DP5-01.htm Super fast 1 ms Mounting the detachable head close to the detecting section minimizes piping and enables a response time of 1 ms, the fastest in the industry, as well as greatly decreasing tact time delay. In addition, the ultra-small and light-weight design of the head means it can be easily mounted on moving sections. A Total of 10 Head Variations to Meet all Production Demands Vacuum pressure type Positive pressure type Compound pressure type (0 to -101.3kPa) (0 to 1.000MPa) (-100.0 to 100.0kPa) ● M5 male thread ● R (PT) 1/8 male thread/ M5 female thread ● ● NPT 1/8 male thread/ 10-32UNF female thread 10-32UNF male thread ● M5 female thread ● M5 female thread ● R (PT) 1/8 male thread/ M5 female thread ● R (PT) 1/8 male thread/ M5 female thread ● NPT 1/8 male thread/ 10-32UNF female thread ● NPT 1/8 male thread/ 10-32UNF female thread Both NPN and PNP outputs are available so that this sensor can be used anywhere in the world. This sensor conforms to the CE marking EMC Directive and has obtained UL recognition. Detachable head means layout freedom. Use it any way you want. Light-weight, Compact Design The controller inherits its light-weight compact design from the popular compact digital pressure sensor, the DP4 series. The control panel setup is inexpensive and requires minimal space. User-friendly Two-color Digital Display The user-friendly two-color digital display changes color when output changes (ON/OFF), making it easy to check operation status at a glance. The display color can be linked to Comparative Output 1 or to Comparative Output 2. Two Independent Outputs Plus Analog Voltage Output In addition to two independent outputs (ON/OFF), an analog voltage output (1 to 5V) is also available. The different outputs allow you to create solutions for a wide variety of applications. file:///G|/DP5/DP5-forweb.htm (3 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Two Operation Indicators There are two operation indicators that light respectively when Comparative Output 1 or Comparative Output 2 is ON. These are convenient for frequent operation checks. Sensor Head Auto-recognition The sensor head's auto-recognition function means that you don't have to manually set the head type at the controller, saving you valuable time. Handy Attachments for Flexible Controller Mounting Panel Mounting Bracket is Supplied A panel mounting bracket is enclosed that allows simple mounting of the controller onto the panel surface. This makes for a more cost-effective system. DIN Rail Mounting Bracket Is Available The controller can even be mounted on a 35mm width DIN rail by using the optional DIN rail mounting bracket (MS-DP2). It can be fitted in a narrow space inside your equipment because it can be mounted from four different directions. Can be Used with Panel Thicknesses from 1 to 6mm Since the panel thicknesses can be from 1 to 6mm, the controller can be mounted on thick, resin-made panels. Select from Six Pressure Units Select the pressure unit from six different systems to suit your requirements. The selectable pressure units differ with the sensor type. When the pressure unit is changed, the measured pressure value and the set values are automatically adjusted. Note: 'MPa' when combining with DPH-A02, DPH-A12 or DPH-A22 positive pressure sensor head. Full Range of Functions in a Compact Body Gives You a Wide Variety of Control Options file:///G|/DP5/DP5-forweb.htm (4 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm The only sensor in the industry with a leak test mode. Four output modes give you complete control. Leak Test Mode It is suitable for a leak test since Comparative Output 1 can be set to the hysteresis mode and Comparative Output 2 can be set to the window comparator mode. Using it along with the autoreference/remote zero-adjustment functions ensures a reliable leak test. Hysteresis mode The hysteresis of the comparative outputs can be set arbitrarily by the set values for the ON/OFF control. Window comparator mode The comparative output can be turned ON or OFF by a pressure which is within the set pressure range. Forced output mode The comparative outputs are forcibly maintained at OFF level in the sensing mode, irrespective of the set values. This is convenient for displaying the pressure value without using the comparative outputs. Since the comparative outputs can be forcibly switched ON or OFF with key operation without actually applying pressure this mode is suitable for an operation or a start-up check. file:///G|/DP5/DP5-forweb.htm (5 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Equipped with auto-reference and remote zero-adjustment function. More accurate pressure control with minimal effort. If the reference pressure of the equipment changes the auto-reference function can adjust the threshold levels by the amount of change and the remote zero adjustment function can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates significantly or where precise settings are desired. Example: When leak test mode is applied, Comparative Output 1 detects the filling pressure and Comparative Output 2 detects the leakage. DP5/ DPH ORDER GUIDE Pressure sensor head Note: The rated pressure range indicates the range for full product performance. Pressure sensor controller Note: The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. An intermediate cable is required to connect the pressure sensor controller and the pressure sensor head. Please purchase the intermediate cable separately. file:///G|/DP5/DP5-forweb.htm (6 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Intermediate cable Panel mounting bracket (accessory) MS-DP-1 OPTIONS Connector 6-core cable with connector DIN rail mounting bracket Controller mounting bracket MS-DP-3 ---------- MS-DP-4 You can attach a commercially available label (9 mm) to the top of the unit to display the sensor number and the sensor application. DP5/DPH SPECIFICATIONS Pressure sensor head file:///G|/DP5/DP5-forweb.htm (7 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Notes: 1. The rated pressure range indicates the range for full product performance. 2. The pressure sensor head can be used independently. DP5/DPH SPECIFICATIONS Pressure sensor controller file:///G|/DP5/DP5-forweb.htm (8 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Notes: 1. The rated pressure range indicates the range for full product performance. It changes automatically according to the connected pressure sensor head. 2. If the wiring is longer than 2m, use a cable with a diameter of 0.3mm² or more. DP5/DPH I/O CIRCUIT AND WIRING DIAGRAMS DP5-C NPN output type I/O circuit diagram file:///G|/DP5/DP5-forweb.htm (9 of 20) [6/11/2001 11:14:04 AM] For independent use of sensor head DP5-01.htm Symbols... D1, D2: Reverse supply polarity protection diode ZD1 to ZD4: Surge absorption zener diode Tr1, Tr2: NPN output transistor Pin position Connector for power supply/ I-O cable connection 1. +V 2. Analog voltage output 3. OV 4. Comparative Note: In case the pressure sensor head is used independently, insulate the white wire (Terminal No.4) and keep it open. Symbols... D: Reverse supply polarity protection diode ZD: Surge absorption zener diode Connector for pressure sensor head connection 1. 2. 3. 4. +V Analog voltage output OV N. C. Output 1 5. Comparative Output 2 6. Auto-reference/ Remote zero-adjustment input DP5-C-P PNP output type I/O circuit diagram Symbols... D1, D2: Reverse supply polarity protection diode ZD1 to ZD4: Surge absorption zener diode Tr1, Tr2: PNP output transistor Connector for power supply/ I-O cable connection file:///G|/DP5/DP5-forweb.htm (10 of 20) [6/11/2001 11:14:04 AM] Connector for pressure sensor head connection DP5-01.htm Pin position 1. +V 2. Analog voltage output 3. OV 4. Comparative 1. 2. 3. 4. +V Analog voltage output OV N. C. Output 1 5. Comparative Output 2 6. Auto-reference/ Remote zero-adjustment input DP5/DPH PRECAUTIONS FOR PROPER USE Error messages ● ● When an error occurs take the following corrective action. This product is not a safety sensor. Its use is not intended or designed to protect life or prevent bodily injury or property damage from dangerous parts of machinery. It is a normal pressure detection sensor. The DPH series is designed for use with non-corrosive gases. It cannot be used with liquids or with corrosive gas. Functional description ● Wiring ● Make certain that the power is off before the wiring is installed. Verify that the supply voltage variation is within the rating. ● f power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. ● In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this controller, connect the frame ground file:///G|/DP5/DP5-forweb.htm (11 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm (FG.) terminal of the equipment to an actual ground. ● If the power supply generates a surge, connect a surge absorber to the power supply to absorb the surge. ● Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This could cause malfunction due to induction. ● In order to reduce noise, make the wiring as short as possible. Improper wiring will damage the sensor. Other Precautions ● ● Use within the rated pressure range. Do not apply pressure exceeding the pressure limits. Excessive pressure will damage the diaphragm and the unit will not function. ● Do not use during the initial transient time (DP5: 3 sec. approx., DPH: 50ms approx.) after the power supply is switched on. ● Avoid dust, dirt, and steam. Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. ● ● Do not insert wires, etc. into the pressure port. This could damage the diaphragm and the unit will not function. ● Do not operate the keys with pointed or sharp objects. DP5/DPH PRECAUTIONS FOR PROPER USE file:///G|/DP5/DP5-forweb.htm (12 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Setting ● If key-protect has been set, make certain that you release the key-protect before operating the keys. (Please refer to "Key-protect function" later in this section.) ● Pressure value setting can be done only if the output mode is set to the hysteresis mode, window comparator mode or the leak test mode. Pressure values cannot be set if the output mode is set to the forced output mode. ● Set Values P-1 to P-4 can be common for all the output modes. For the positive pressure type and the compound pressure type, Set Value P-2 should be set towards the higher pressure side with respect to Set Value P-1 and Set Value P-4 should be set towards the higher pressure side with respect to Set Value P-3. Also, in the vacuum pressure type, Set Value P-2 should be set towards the higher vacuum side with respect to Set Value P-1 and Set Value P-4 should be set towards the higher vacuum side with respect to Set Value P-3. ● ● ● ● The auto-reference function affects only Set Value P-3 and Set Value P-4. Set Value P-A is the pressure value when the auto-reference input or the remote zero-adjustment input is applied. When the auto-reference input or the remote zero-adjustment input is not applied, Set Value P-A is zero. The set conditions are written and stored in an EEPROM. Note that the EEPROM has a guaranteed lifespan of 100,000 write operation cycles. Since the auto-reference input value and the remote zero-adjustment input value are not stored in the EEPROM, they are not included in the number of write operation cycles. file:///G|/DP5/DP5-forweb.htm (13 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm DP5/DPH PRECAUTIONS FOR PROPER USE Auto-reference function ● Operation Chart Auto-reference function corrects Set Value P-3 taking the pressure measured at the time of auto-reference input as the reference pressure. When there is no auto-reference input, the atmospheric pressure is taken as the reference pressure for Set Value P-3 and Set Value P-4. ● At the time of auto-reference input, the pressure value detected at that instant is temporarily recorded as Set Value P-A and becomes the reference pressure. Auto-reference input: 50kPa Output mode: Hysteresis mode Note: In the hysteresis mode, Set Value P-3 and Set Value P-4 are shifted. The output is set to the window comparator mode or the leak test mode. With Set Value P-A as the reference pressure, Set Value P-3 and Set Value P-4 are automatically corrected to 'Set Value P-3 + Set Value PA' and 'Set Value P-4 + Set Value P-A' respectively. Settable range and set pressure range after correction ● ● ● Maintain the pressure at a constant level for at least 2ms after the auto-reference input is changed to Low (High in case of PNP output type). If used in a transient state it will not operate properly.. ● Use Comparative Output 2 at least 'set response time + 2ms' after the auto-reference input is made changed to Low (High in case of PNP output type). ● At the time of auto-reference input, displayed on the 3-1/2 digit display for approximately 1 second. ● The auto-reference input value (Set Value P-A) The settable range of Set Value P-3 and Set Value P-4 is wider than the rated pressure range to allow the auto-reference function. file:///G|/DP5/DP5-forweb.htm (14 of 20) [6/11/2001 11:14:04 AM] is DP5-01.htm ● At the time of auto-reference input, if the corrected set value exceeds the set pressure range, the set value is automatically corrected to be within the set pressure range. Please make certain that the set pressure range is not exceeded. changes to zero when the power supply is switched off and then on again. ● Although it is not possible to display the corrected 'Set Value P-3' and 'Set Value P-4', it is possible to display the auto-reference input value (Set Value P-A). DP5/DPH PRECAUTIONS FOR PROPER USE Remote zero-adjustment function Forced output mode ● The remote zero-adjustment function forcibly sets ● In the initial setting mode, if the output the pressure value at the time of application of an external input signal to zero. mode is set to the forced output mode ● At the time of remote zero-adjustment input, the the comparative outputs are forcibly set values are not corrected. When using the maintained at OFF level in the sensing remote zero-adjustment function make certain that mode, irrespective of Set Values P-1 to P-4. the pressure and the set values do not exceed the If the keys are operated as per the rated pressure ranges. procedure given below the comparative outputs can be forcibly switched either ON Operation chart or OFF without applying pressure at the pressure port. This is convenient for an Normal operation operation check of the comparative outputs (comparative outputs set to NO) or for an inspection before starting work. (The diagram below appears when the DP5-C has been used to set the display to 'Digital display' With remote zero-adjustment input (comparative outputs set to NO) Remote zero-adjustment input: 50kPa Output mode: Hysteresis mode ● In the sensing mode, press the key to change to the forced output mode. ● Each time UP key is pressed, Comparative Output 1 switches to ON and OFF, alternately. Each time the DOWN key is pressed, Comparative Output 2 switches to ON and OFF alternately. ● Press the key to return to the sensing mode. Output is kept off at the point where the mode is changed from another output mode ● Note: In the hysteresis mode the displayed values and the ON/OFF points of the output are changed in case the output mode is set to the window comparator mode. Remote zero-adjustment input: 50kPa Output mode: Leak test mode file:///G|/DP5/DP5-forweb.htm (15 of 20) [6/11/2001 11:14:04 AM] . ● to forced output control mode . Even if output has been set to stay on during forced output control mode, it will be forcibly changed to off at the point where DP5-01.htm the mode changes back to sensing mode. Peak hold & bottom hold function Note: In the leak test mode, the zero-adjustment function is applied only to Comparative Output 2. Comparative Output 1 operates with the atmospheric pressure as the reference. ● Maintain the pressure at a constant level for at least 2ms after the remote zero-adjustment input is changed to Low (High in case of PNP output type). If used in a transient state, it will result in wrong operation. ● Use the comparative outputs at least 'set response time + 2ms' after the remote zero adjustment input is changed to Low (High in case of PNP output type). ● At the time of remote zero-adjustment input, is displayed on the 3-1/2 digit display for approximately 1 second. ● If the power supply is switched off and then on again, the remote zero-adjustment input value is cleared and the sensor returns to normal operation with atmospheric pressure as the reference. ● Peak hold and bottom hold functions enable the display of the peak value (maximum pressure value) and the bottom value (minimum pressure value) of the varying measured pressure. ● These functions are convenient for finding the pressure variation range or determining the reference for pressure settings. ● Please note that the peak value and the bottom value data is erased when it is no longer displayed. Peak hold display ● In the sensing mode, keep the UP key pressed until is displayed. (4 sec. or more). ● When the finger is released after displayed, the peak value and displayed alternately. Press the UP key. ● file:///G|/DP5/DP5-forweb.htm (16 of 20) [6/11/2001 11:14:04 AM] is are ● ( If the applied pressure exceeds the displayable pressure range an error message and are displayed alternately. When this happens restore the applied pressure to within the rated pressure range. ● The figure above shows the display of a vacuum type sensor.) DP5-01.htm Bottom hold display ● In the sensing mode, keep the DOWN key pressed until the or more). ● is displayed. (4 sec. When the finger is released after is displayed, the bottom value and displayed alternately. are ● Press the DOWN key. ● ( If the applied pressure exceeds the displayable pressure range, error message and are displayed alternately. In this case, bring back the applied pressure to within the rated pressure range. ● The figure above shows the display of a vacuum type sensor. ) DP5/DPH PRECAUTIONS FOR PROPER USE Key-protect function ● Connecting Key-protect is a function which prevents any unintentional change to settings which you have entered. Setting of key-protect In the sensing mode, key press continuously for 4 sec. or more and release it ● ● immediately when is displayed. (Key-protect is set and the sensor returns to the sensing mode.) Since the key-protect information is stored in an EEPROM, it is not erased when the power supply is switched off. ● To connect the pressure sensor head to the pressure controller the optional intermediate cable (DPH-CC•) must be used. ● Take care that excess pressure is not directly applied to the cable joint or to the connector. ● If the pressure sensor head is to be mounted on a movable surface a flexible intermediate cable must be used. ● When connecting the intermediate cable to the pressure controller, make sure to fit the connector cap, supplied as an accessory with the pressure controller, by sliding it as shown in the figure below. If the connector cap is not fitted correctly, there the possibility that the intermediate cable could be disconnected from the sensor. Please check to see if the key-protect function has been set. Release of key-protect file:///G|/DP5/DP5-forweb.htm (17 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm In the sensing mode, key press the continuously for 4 sec. or more and release it immediately when is displayed. (Key-protect is released and the sensor returns to the sensing mode. When the keys are to be operated, make sure that the key-protect function is released. Piping When connecting a commercial coupling to the pressure port, hold the hexagonal section of the pressure port with an 11 mm (DPH-A1•) or a 12mm (DPHA2•) spanner, and make certain that the tightening torque is 1 N·m for male thread type of DPH-A1• or 5N·m or less for the DPH-A2•). If excessive tightening torque is applied the M5 male thread of the commercial coupling or the pressure port could be damaged. Mounting Install the enclosed panel mounting bracket (MS-DP-1) as shown in the figure below. The tightening torque should be 0.15N·m or less. Tighten both the right and the left screw gradually and equally, so that the panel mounting bracket does not tilt. DIMENSIONS (Unit: mm) DP5-C• Pressure controller file:///G|/DP5/DP5-forweb.htm (18 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm DP5/DPH DIMENSIONS (Unit: mm) DPH-A0• DPH-A30 Sensor head DPH-A1• DPH-A2• Sensor head MS-DP-1 Panel mounting bracket (accessory) Assembly dimensions Panel cut-out dimensions MS-DP2 DIN rail mounting bracket (optional) Assembly dimensions Horizontal mounting Vertical mounting DP5/DPH DIMENSIONS (Unit: mm) DPH-CC• Intermediate cable (optional) file:///G|/DP5/DP5-forweb.htm (19 of 20) [6/11/2001 11:14:04 AM] DP5-01.htm Note: The heat-shrink tube for the standard cable is black, and the heatshrink tube for the flexible cable is gray. CN-66 Connector (optional) Housing - Connector pin CN-66-C2 Cable with connector (optional) MS-DP-3 Controller mounting bracket (optional) MS-DP-4 Controller mounting bracket (optional) Material: Cold rolled carbon steel (SPCC) Material: Cold rolled carbon steel (SPCC) (Uni-chrome plated) (Uni-chrome plated) Note: Use together with panel mounting bracket included Note: Use together with panel mounting bracket included with sensor. with sensor. file:///G|/DP5/DP5-forweb.htm (20 of 20) [6/11/2001 11:14:04 AM]
DP5-C 价格&库存

很抱歉,暂时无法提供与“DP5-C”相匹配的价格&库存,您可以联系我们找货

免费人工找货