0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DPH-L113

DPH-L113

  • 厂商:

    NAIS(松下)

  • 封装:

    Cylinder,Threaded

  • 描述:

    SENSOR HEAD 0 TO +1.0MPA

  • 数据手册
  • 价格&库存
DPH-L113 数据手册
735 FIBER SENSORS Head-separated Dual Display Digital Pressure Sensor For Liquid & Gas DPC-L100 SERIES DPH-L100 SERIES Related Information ■■General terms and conditions.............. F-3 ■■Glossary of terms......................... P.1563~ ■■Selection guide.............................. P.699~ ■■General precautions....................... P.1566 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS panasonic.net/id/pidsx/global Digital Auto reference With analog output High-precision detection of fluid and air pressure Allows high-precision fluid pressure management Compact stainless body The analog voltage output of the sensor head can achieve a high-precision sensing of ±1 % F.S. (at a normal temperature of 23 °C 73.4 °F). Compact size of HEX. 22 × 59 mm 0.866 × 2.323 in (excluding the screws). The body is also stainless so it can be used in various environments. Oil-less single-layer diaphragm 59 mm 2.323 in Oil is not encapsulated in the diaphragm of the pressure sensing portion. No need to worry that oil will leak into the medium when the sensor head is damaged. Diaphragm: Stainless steel (SUS630) Pressure port: Stainless steel (SUS304) Throttle: Stainless steel (SUSXM7) Stainless diaphragm (Integrated pressure transducer) Main circuit Selection Guide Pressure/ Digital Display Pressure/ Head-separated HEX.22 mm 0.866 in R1/4 male thread Piezo-electric conversion Flow Stainless steel (SUS630) Strong against pressure surges from throttle loading Pressure port Stainless steel (SUS304) Controls pressure surges and reduces sensor failure. Throttle Stainless steel (SUSXM7) DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 Throttle Product line Color continuum DPH-L113V -0.1 to +1.0 MPa For use with pressurized air and other media (air mixed with water or oil) DPH-L113 0 to +1.0 MPa Air Water For use with pressurized fluid and other media (water or chemical solutions) DPH-L133 0 to +3.5 MPa DPH-L114 0 to +10 MPa Oil For use with pressurized oil and other media DPH-L154 0 to +50 MPa –0.1 0 +1 +3.5 Pressure range (MPa) +10 +50 Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES APPLICATIONS 736 FIBER SENSORS Transport of glass sheets after washing (Air pressure with waterdrops) Management of plastic filling machine pressure (Fluid pressure) Management of press pressure (Oil pressure) LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS The dual display means that the “current value” and the “threshold value”, it makes direct setting of threshold value Equipped with a 30 mm 1.181 in square compact-sized dual display. Because the current value and the threshold value can be checked at the same time, the threshold value can be set and checked smoothly without having to switch screen modes. ON/OFF operations are still carried out while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. And naturally a key lock function is also equipped. SENSOR OPTIONS Current value SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS Threshold value PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS 3-color display (Red, Green, Orange) Equipped with new functions optimal for fluid pressure The main display changes color in line with changes in the status of output ON/OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced. Equipped with functions optimal for fluid pressure management while inheriting the operability of the DP-100 series. FA COMPONENTS • Peak / Bottom hold (output-linked) UV CURING SYSTEMS Main Display OFF: Green (or Red) ON: Red (or Green) During normal operation SET: Orange During setting When output turns on (or off), the controller’s digital display (current value) is reset and peak / bottom hold operation starts. For example, this functionality could be used to verify the peak pressure for an industrial press each time a workpiece is loaded. • Current value hold The controller’s digital display (current value) is held while external input is on. By activating external input the moment you wish to capture the pressure value, you can pause and verify the display. MOUNTING An exclusive mounting bracket MS-DP1-2 that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. Takes up much less space Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 Tight installation to panels is possible Tight installation is possible MACHINE VISION SYSTEMS Front protection cover available MS-DP1-3 A single mounting hole! 737 FIBER SENSORS Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES PRODUCT CONFIGURATION LASER SENSORS Connector (e-CON) Sensor head PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Sensor heads Type SIMPLE WIRE-SAVING UNITS Compound pressure Appearance WIRE-SAVING SYSTEMS Positive pressure STATIC CONTROL DEVICES Rated pressure range Model No. -0.1 to +1.0 MPa DPH-L113V 0 to +1.0 MPa DPH-L113 0 to +3.5 MPa DPH-L133 0 to +10 MPa DPH-L114 0 to +50 MPa DPH-L154 LASER MARKERS PLC Controllers Appearance HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS Model No. Comparative output DPC-L101 NPN open-collector transistor DPC-L101-P PNP open-collector transistor FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS * CN-66A-C2 (Connector attached cable 2 m 6.562 ft) is attached. Type without connector attached cable Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 Connector attached cable ORDER GUIDE SENSOR OPTIONS MEASUREMENT SENSORS Power supply connector Controller SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Type without connector attached cable is available. When ordering this type, suffix “-J” to the Model No. (e.g.) Type without connector attached cable of DPC-L101-P is “DPC-L101-P-J”. Accessory • CN-66A-C2 (Connector attached cable 2 m 6.562 ft) Pressure port Applicable fluid R1/4 male thread Gases and fluids that do not corrode stainless steel SUS304, SUS630, or SUSXM7 Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES OPTIONS FIBER SENSORS Sensor head connector (e-CON) Designation Sensor head connector (e-CON) Connector attached cable Power supply connector Model No. CN-EP2 (Note 1) 5 pcs. per set Description ••CN-EP2 MICRO PHOTOELECTRIC SENSORS CN-66A-C2 (Note 2) Length 2 m 6.562 ft Controller power supply I/O cable. CN-66A-C5 CN-66A 5 pcs. per set 0.2 mm² 6-core oil-resistant cabtyre Length 5 m 16.404 ft cable with connector Note: O  ne is attached to each sensor head according to standard. Connector for controller power supply I/O cable. Connector attached cable ••CN-66A-C2 ••CN-66A-C5 MS-DP1-6 Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. Panel mounting bracket MS-DP1-2 Allows installation to panels with thickness of 1 to 6 mm 0.039 to 0.236 in. Multiple sensors can also be mounted closely. MS-DP1-3 Protects the adjustment surfaces of controllers. (Can be attached when using the panel mounting bracket) Controller mounting bracket ••CN-66A ••MS-DP1-6 Connector pin M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-6 ( Housing SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Note: The connector attached cable CN-66A-C2 is supplied with the controller according to standard. Panel mounting bracket, Front protection cover ••MS-DP1-2 ••MS-DP1-3 WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC ) HUMAN MACHINE INTERFACES Front protection cover MS-DP1-3 Controller mounting bracket MS-DP1-6 (Optional) AREA SENSORS PARTICULAR USE SENSORS Notes: 1) One is attached to each sensor head according to standard. 2) The connector attached cable CN-66A-C2 is supplied with the controller according to standard. Power supply connector LASER SENSORS PHOTOELECTRIC SENSORS Connector for connecting sensor head controller Controller mounting bracket Front protection cover 738 ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS Panel mounting bracket MS-DP1-2 MACHINE VISION SYSTEMS UV CURING SYSTEMS Recommended e-CON Model No.: 1473562-4 (Manufactured by Tyco Electronics Japan G.K.) Note: Contact the manufacturer for details of the recommended products. Recommended power supply connector Contact: SPHD-001T-P0.5, Housing: PAP-06V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 739 Head-separated Dual Display Digital Pressure Sensor SPECIFICATIONS FIBER SENSORS LASER SENSORS Sensor heads PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Type Item Model No. Rated pressure range Pressure withstandability MACHINE VISION SYSTEMS UV CURING SYSTEMS 10 MPa type 50 MPa type DPH-L133 DPH-L114 DPH-L154 -0.1 to +1 MPa 0 to +1 MPa 0 to +3.5 MPa 0 to +10 MPa 0 to +50 MPa 2 MPa 2 MPa 7 MPa 20 MPa 75 MPa Gases and fluids that do not corrode stainless steel SUS630, SUS304, or SUSXM7 Supply voltage 9 to 36 V DC [9 to 32 V DC when using the attached connector (e-CON)] Current consumption 20 mA or less Output voltage: 1 to 5 V DC (over rated pressure range) Accuracy: ±1.0 % F.S. (at +23 ±2 °C +73.4 ±35 °F) ±2.0 % F.S. (at -20 to +70 °C -4 to +158 °F) (including linearity, hysteresis and repeatability) Environmental resistance Ambient temperature IP67 (IEC) -20 to +70 °C -4 to +158 °F (No dew condensation or icing allowed), Storage: -30 to +70°C -22 to +158 °F Ambient humidity Medium temperature range -20 to +70 °C -4 to +158 °F Voltage withstandability Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 -20 to +125 °C -4 to +257 °F 150 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 100 MΩ, or more, with 50 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 2,000 Hz frequency, acceleration 200 m/s2, in X direction for four hours, in Y and Z directions for two hours each (Note 5) 1,000 m/s2 acceleration in X, Y and Z directions three times each Shock resistance Grounding method Capacitor earth (Enclosure-supply terminal) Pressure port Material R1/4 male thread (throttle embeded) Diaphragm: Stainless steel (SUS630), Pressure port: Stainless steel (SUS304), Throttle: Stainless steel (SUSXM7) Connecting method Connector 0.2 mm 3-core heat resistant cabtyre cable 2 m 3.562 ft long 2 Extension up to total 10 m 32.808 ft is possible with 0.2 mm2, or more, cable. Cable extension Pressure/ Digital Display -20 to +80 °C -4 to +176 °F (Pressure port: -20 to +125 °C -4 to +257 °F, No dew condensation or icing allowed), Storage: -30 to +100 °C -22 to +212 °F e-CON connector (accesory): -20 to +75 °C -4 to +167 °F (Storage: -30 to +75 °C -22 to +167 °F) 35 to 85 % RH, Storage: 35 to 85 % RH Cable Selection Guide Output voltage: 1 to 5 V DC (over rated pressure range) Accuracy: ±1.0 % F.S. (at +23 ±2 °C +73.4 ±35 °F) ±2.0 % F.S. (at -20 to +125 °C -4 to +257 °F) (including linearity, hysteresis and repeatability) 1 ms or less Protection MEASUREMENT SENSORS FA COMPONENTS 3.5 MPa type DPH-L113 Applicable fluid WIRE-SAVING SYSTEMS ENERGY MANAGEMENT SOLUTIONS 1 MPa type DPH-L113V EMC Directive, RoHS Directive Response time HUMAN MACHINE INTERFACES -0.1 to 1 MPa type Sealed gauge pressure (Note 4) SIMPLE WIRE-SAVING UNITS PLC Positive pressure Type of pressure Analog voltage output LASER MARKERS Compound pressure CE marking directive compliance SENSOR OPTIONS STATIC CONTROL DEVICES DPC-L100 SERIES DPH-L100 SERIES Weight Net weight: 100 g approx., Gross weight: 150 g approx. Accessory Connector (e-CON): 1 pc. Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +23 °C +73.4 °F. 2) The sensor head can be used independently. 3) Oil is used in the factory inspection process for models DPH-L114 and DPH-L154. There may be some residual oil inside the pressure port. 4) The sensor’s internal mechanism is sealed based on an air pressure of 1,013 hPa. 5) The X, Y, and Z directions are defined as follows: X Z Y Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES SPECIFICATIONS FIBER SENSORS LASER SENSORS Model No. Controllers Item DPC-L101 NPN output PHOTOELECTRIC SENSORS DPC-L101-P PNP output EMC Directive, RoHS Directive CE marking directive compliance DPH-L113V DPH-L113 DPH-L133 DPH-L114 DPH-L154 -0.1 to +1 MPa 0 to +1 MPa 0 to +3.5 MPa 0 to +10 MPa 0 to +50 MPa -1.177 to +1.177 MPa -12.00 to +12.00 kgf/cm² -11.77 to +11.77 bar -170.6 to +170.6 psi -1.070 to +1.070 MPa -10.91 to +10.91 kgf/cm² -10.70 to +10.70 bar -155.2 to +155.2 psi -3.74 to +3.74 MPa -38.1 to +38.1 kgf/cm² -37.4 to +37.4 bar -542 to +542 psi -10.70 to +10.70 MPa -109.1 to +109.1 kgf/cm² -107.0 to +107.0 bar -1552 to +1552 psi -53.5 to +53.5 MPa -545 to +545 kgf/cm² -535 to +535 bar -1980 to +7760 psi Set resolution 0.001 MPa 0.001 MPa 0.01 MPa 0.01 MPa 0.1 MPa Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) Applicable sensor head Rated pressure range Set pressure range Displayable pressure range Supply voltage Power consumption Comparative outputs (Comparative output 1, 2) -0.155 to +1.022 MPa -1.58 to +10.42 kgf/cm² -1.55 to +10.22 bar -22.4 to +148.2 psi -0.050 to +1.020 MPa -0.51 to +10.40 kgf/cm² -0.50 to +10.20 bar -7.2 to +148.0 psi Output modes Hysteresis NPN open-collector transistor (2 outputs) • Maximum sink current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Residual voltage: 1 V or less (at 50 mA sink current) Inputs Sensor head input External input -2.5 to +51.0 MPa -25 to +520 kgf/cm² -25 to +510 bar -360 to +7400 psi PNP open-collector transistor (2 outputs) • Maximum source current: 50 mA • Applied voltage: 30 V DC or less (between comparative output and +V) • Residual voltage: 1 V or less (at 50 mA source current) NO/NC, selectable by key operation EASY mode / Hysteresis mode / Window comparator mode Minimum 1 digit (variable) (however, 2 digits when using psi unit) Within ±0.2 % F.S. 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation Short-circuit protection Analog output -0.50 to +10.20 MPa -5.1 to +104.0 kgf/cm² -5.0 to +102.0 bar -72 to +1480 psi 12 to 24 V DC ±10 % Ripple P-P 10 % or less Repeatability Response time -0.17 to +3.57 MPa -1.7 to +36.4 kgf/cm² -1.7 to +35.7 bar -24 to +518 psi Normal operation: 960 mW or less (Current consumption 40 mA or less at 24 V supply voltage) ECO mode (STD): 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode (FULL): 600 mW or less (Current consumption 25 mA or less at 24 V supply voltage) Excluding the current consumption of sensor head and analog output current Output operation Incorporated • Output current: 1 to 5 V DC • Zero point: within 1 V ±0.5 % F.S. (excluding DPH-L113V) within 1.364 V ±0.5 % F.S. (DPH-L113V) • Span: within 4 V ±0.5 % F.S. • Linearity: within ±0.1 % F.S. • Output impedance: 1 kΩ approx. • Output current: 4 to 20 mA • Zero point: w  ithin 4 mA ±1.0 % F.S. (excluding DPH-L113V) within 5.455 mA ±1.0 % F.S. (DPH-L113V) • Span: within 16 mA ±1.5 % F.S. • Linearity: within ±0.1 % F.S. • Load resistance: 250 Ω (max.) ON voltage: 5 V to +V DC OFF voltage: 0.6 V DC or less, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more Protection IP40 (IEC) Environmental resistance Orange LED (Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON ) Ambient temperature Ambient humidity Voltage withstandability -10 to +50 °C +14 to +122 °F (No dew condensation or icing allowed), Storage: -10 to +60 °C +14 to +140 °F 35 to 85 % RH, Storage: 35 to 85 % RH 500 V AC for one min. between all supply terminals connected together and enclosure Insulation resistance 50 MΩ, or more, with 500 V DC megger between all supply terminals connected together and enclosure Vibration resistance 10 to 500 Hz frequency, double amplitude 3 mm 0.118 in or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel mounting bracket is mounted: 10 to 150 Hz frequency, double amplitude 0.75 mm 0.030 in or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) Shock resistance Temperature characteristics Material Connecting method Weight Accessories MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Input voltage range: 1 to 5 V DC (over rated pressure range) ON voltage: 0.4 V DC or less OFF voltage: 5 to 30 V DC, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more Operation indicator Cable length 740 100 m/s2 acceleration in X, Y and Z directions three times each Within ±0.5 % F.S. (ambient temperature range based on +20 °C +68 °F) Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber Connector Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. Net weight: 25 g approx. (excluding connector attached cable), Gross weight: 140 g approx. CN-66A-C2 (Connector attached cable 2 m 6.562 ft), Pressure unit label: 1 set Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) The values specified above are applied only to the controller. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 741 Head-separated Dual Display Digital Pressure Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS DPC-L101 I/O circuit diagram CN2 terminal No. MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Sensor head internal circuit 10kΩ D 2 1kΩ D3 Tr1 ZD1 ZD2 Tr2 (Brown) +V (Pink) External *1 input (Gray) Analog voltage / current output Load (Note 1,2) Load + (Black) Comparative output 1 – 50 mA max. (White) Comparative output 2 (Blue) 0 V Controller internal circuit Intermediate cable Terminal No. Color code (Brown) +V 12 to 24 V DC ±10 % 50 mA max. User’s circuit Notes: 1) Set the output load resistance during analog current output to 250 Ω (max.). 2) Note that a voltage of 5 V or higher is generated during analog current output. SIMPLE WIRE-SAVING UNITS Sensor head internal circuit *1 Non-voltage contact or NPN open-collector transistor STATIC CONTROL DEVICES or LASER MARKERS High (5 to 30 V DC, or open): Invalid Low (0.4 V DC or less): Valid PLC (Black) Analog voltage output (1 to 5 V) + – 9 to 36 V DC (Blue) 0 V User’s circuit Notes: 1) When the sensor head is used independently, devices connected to the analog output must have an input impedance set at 10 kΩ or more and load capacity 1,000 pF or less. 2) No short-circuit protection circuit is provided for analog voltage output. Do not connect directly to a power supply. 3) The pressure port and internal circuitry are connected by a capacitor. Do not apply voltage in excess of the specifications’ dielectric strength between the pressure port and wiring. 4) The transparent tube attached to the cable is not used and should be cut off at the base. Symbols …D1 to D3 : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : NPN output transistor WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Unused 0V PARTICULAR USE SENSORS SENSOR OPTIONS Color code of connector attached cable D1 Analog voltage input For independent use of sensor head CN1 terminal No. +V Sensor head main circuit AREA SENSORS NPN output type Sensor head main circuit PHOTOELECTRIC SENSORS Controller main circuit LASER SENSORS DPC-L100 SERIES DPH-L100 SERIES HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS I/O circuit diagram Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 For independent use of sensor head Color code of connector attached cable +V Terminal No. (Brown) +V Sensor head main circuit Pressure/ Digital Display CN1 terminal No. CN2 terminal No. UV CURING SYSTEMS Selection Guide PNP output type Unused Analog voltage input 0V Sensor head internal circuit Intermediate cable D1 Tr1 10kΩ D2 ZD1 Tr2 ZD2 1kΩ D3 (Pink) External *1 input (Black) Comparative 50 mA max. output 1 (White) Comparative 50 mA max. output 2 (Gray) Analog voltage / current output (Note 1, 2) (Blue) 0 V Controller internal circuit Color code (Brown) +V + – Load Load User’s circuit Notes: 1) Set the output load resistance during analog current output to 250 Ω (max.). 2) Note that a voltage of 5 V or higher is generated during analog current output. Symbols …D1 to D3 : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : PNP output transistor *1 Non-voltage contact or PNP open-collector transistor or High (5 to +V DC, or open): Invalid Low (0.6 V DC or less, or open): Valid 12 to 24 V DC ±10 % Sensor head main circuit MACHINE VISION SYSTEMS DPC-L101-P Controller main circuit FA COMPONENTS Sensor head internal circuit (Black) Analog voltage output (1 to 5 V) + – 9 to 36 V DC (Blue) 0 V User’s circuit Notes: 1) When the sensor head is used independently, devices connected to the analog output must have an input impedance set at 10 kΩ or more and load capacity 1,000 pF or less. 2) No short-circuit protection circuit is provided for analog voltage output. Do not connect directly to a power supply. 3) The pressure port and internal circuitry are connected by a capacitor. Do not apply voltage in excess of the specifications’ dielectric strength between the pressure port and wiring. 4) The transparent tube attached to the cable is not used and should be cut off at the base. Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES 742 I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS LASER SENSORS Terminal arrangement diagram 1 2 3 4 5 6 Connector for power supply I/O cable connection Connector for power supply I/O cable (CN1) Connector for sensor head (CN2) 1 +V 2 Analog voltage / current output 3 0 V 4 Comparative output 1 5 Comparative output 2 6 External input auto-reference function / remote zero-adjustment function / current value hold function 1 Sensor head supply voltage 2 Analog voltage input 3 0 V 4 Unused 2 3 MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS Connector for sensor head connection 1 PHOTOELECTRIC SENSORS INDUCTIVE PROXIMITY SENSORS 4 PARTICULAR USE SENSORS PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • The DPH-L100 series is designed for use with air and non-corrosive gas. It cannot be used with liquid or corrosive and inflammable gases. Part description Main display Output 1 operation indicator Output 2 operation indicator Sub display Refer to p.1566 for general precautions. Others • Never remove the throttle. • Use within the rated pressure range. • Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. • Do not use during the initial transient time (controller: 0.5 sec. approx, sensor head: 50 ms approx.) after the power supply is switched on. • Avoid dust, dirt, and steam. • Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. • Do not operate the keys with pointed or sharp objects. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Mode selection key Set value DOWN key Set value UP key Wiring • Make sure that the power supply is off while wiring. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. • Incorrect wiring will cause problems with operation. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 743 FIBER SENSORS LASER SENSORS Head-separated Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) Sensor head 22 0.866 MICRO PHOTOELECTRIC SENSORS 14 6 0.551 0.236 73 (2.874 ) 18.5 12 (0.728 ) (0.472 ) 11.5 0.453 AREA SENSORS (0.924.3 57 ) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS INDUCTIVE PROXIMITY SENSORS The CAD data can be downloaded from our website. DPH-L1□ PHOTOELECTRIC SENSORS PRESSURE / FLOW SENSORS DPC-L100 SERIES DPH-L100 SERIES ø0.7 ø0.028 throttle R1/4 male thread ø20 ø0.787 ø20 ø0.787 Cap ø25 ø0.984 ø4.3 ø0.169 cable 2 m 6.562 ft long 3-core × 0.2 mm2 insulator diameter: ø1.0 ø0.039 DPC-L101(-P) Controller 15.8 0.622 PARTICULAR USE SENSORS 7.9 0.311 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS 30 1.181 25.6 1.008 MEASUREMENT SENSORS STATIC CONTROL DEVICES 3.8 0.150 Pressure/ Digital Display Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100 1.5 0.059 Controller mounting bracket (Optional) Assembly dimensions 9.5 0.374 (R) 14.5 0.571 4.2 0.165 21 0.827 4.2 0.165 14.5 0.571 (R) 9.5 25.5 0.374 1.004 21 0.827 UV CURING SYSTEMS Selection Guide 9.05 0.356 MS-DP1-6 ENERGY MANAGEMENT SOLUTIONS MACHINE VISION SYSTEMS 18 0.709 2-M3 female thread, 4 0.157 deep 8.9 0.350 7.3 0.287 PLC FA COMPONENTS 20 0.787 6.4 0.252 20.2 30 0.795 1.181 LASER MARKERS HUMAN MACHINE INTERFACES 3.7 0.146 25.5 1.004 20 0.787 2-ø3.5 ø0.138 mounting hole 2 0.079 34.3 30 1.350 1.181 10.5 0.413 45 ( 1.772 ) 10 0.394 18 0.709 29.95 1.179 Material: Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) Two M3 (length 6 mm 0.236 in) screws with washers are attached. 8.9 0.350 30 ( 1.181 ) 30 1.181 45 1.772 1.5 0.059 30 1.181 3.7 0.146 30 1.181 2 0.079 9.05 0.356 6.4 0.252 15.8 0.622 Head-separated Dual Display Digital Pressure Sensor DPC-L100 SERIES DPH-L100 SERIES DIMENSIONS (Unit: mm in) 744 The CAD data can be downloaded from our website. MS-DP1-2 MS-DP1-3 Panel mounting bracket (Optional), Front protection cover (Optional) Mounting drawing with DPC-L101(-P) Vertical mounting MICRO PHOTOELECTRIC SENSORS Horizontal mounting 15.8 0.622 Panel mounting bracket ( ) ( ) 7.2 0.283 ( 34.5 1.358 ) 20 0.787 6 0.236 8.7 0.343 33.4 1.315 24 0.945 18.3 0.720 ( PRESSURE / FLOW SENSORS ) 11 0.433 INDUCTIVE PROXIMITY SENSORS ) 39.3 1.547 34.5 1.358 3.7 0.146 6.4 0.252 A ) 20 0.787 3.7 0.146 PARTICULAR USE SENSORS SENSOR OPTIONS 6.4 0.252 6 0.236 A 8.7 0.343 50 1.969 33.4 1.315 Panel thickness dimension 1 to 6 0.039 to 0.236 18.3 0.720 7.2 0.283 ( 34.5 1.358 Panel thickness dimension 1 to 6 0.039 to 0.236 52 2.047 max. M3 female thread, 4 0.157deep 52 2.047 max. 9.05 0.356 View A 9.05 0.356 MEASUREMENT SENSORS PLC ( ) HUMAN MACHINE INTERFACES View A ENERGY MANAGEMENT SOLUTIONS Material: Polyacetal (Panel mounting bracket) Polycarbonate (Front protection cover) FA COMPONENTS Panel cut-out dimensions When 1 unit is installed WIRE-SAVING SYSTEMS LASER MARKERS 33.4 1.315 ( ) SIMPLE WIRE-SAVING UNITS STATIC CONTROL DEVICES 8.9 0.350 8.9 0.350 50 33.4 1.969 1.315 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Front protection cover Front protection cover ( AREA SENSORS Panel mounting bracket 11 0.433 39.3 1.547 34.5 1.358 LASER SENSORS PHOTOELECTRIC SENSORS Assembly dimensions 15.8 0.622 FIBER SENSORS When “n” units are installed horizontally in series When “n” units are installed vertically in series UV CURING SYSTEMS −0 31−0.4 −0 1.220−0.016 31 1.220 × n + 3.5 0.138 × (n-1) −0 MACHINE VISION SYSTEMS −0 31−0.4 −0 1.220 −0.106 31−0.4 −0 1.220 −0.016 55 2.165 or more −0 31−0.4 −0 1.220 −0.106 31 1.220 × n + 3.5 0.138 × (n-1) Selection Guide Pressure/ Digital Display Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. CN-66A-C2 CN-66A-C5 (0.3158 ) 35 (1.378 ) 55 2.165 or more Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. Connector attached cable (Optional, CN-66A-C2 is attached to the controller) • Length L L 50 (1.969 ) (0.3158 ) ø4.8 ø0.189 cable 6-core × 0.2 mm2 insulator diameter: ø1.2 ø0.047 Model No. Length L CN-66A-C2 2,000 78.740 CN-66A-C5 5,000 196.850 Pressure/ Head-separated Flow DPC-L100/ DPH-L100 DPS-400/ DPH-100 DPC-100/ DPH-100
DPH-L113 价格&库存

很抱歉,暂时无法提供与“DPH-L113”相匹配的价格&库存,您可以联系我们找货

免费人工找货