Programmable Terminals
As an machine management tool ... as an
information terminal ... as a system component
As a global supplier of HMI solutions and high-reliability industrial touch screen technology for over 12
years, Omron has supplied more than 500,000 pieces of HMI through more than 200 world-wide sales
and support offices each offering after-sales support, service and training in the local language.
We also understand the changing needs of our customers. As control systems become more complex
the HMI is increasingly being used not only as an operator display and data-setting terminal, but also as
a maintenance tool for the complete control system. Many HMI applications now contain 100’s of
screens of maintenance information for the complete control system and Omron's easy software and
hardware integration within the control system can greatly reduce programming time needed and also
greatly increase the functionality of the maintenance, therefore dramatically reducing the total cost of
ownership.
Higher
Select by screen size. Select by functions.
The wide array of NT- and NS-series PTs
suits most applications.
NS5(STN)
NS8(TFT)
320 × 240 dots
NS10
(TFT)
640 × 480 dots
Functionality
640 × 480 dots
NS12
(TFT)
800 × 600 dots
NT631C
(TFT/STN color)
640 × 480 dots
NT31C
(STN color)
320 × 240 dots
NT631
(EL)
640 × 480 dots
NT31
(STN monochrome)
320 × 240 dots
NT21S
Lower
(STN monochrome)
260 × 140 dots
Smaller
636
NT2S
NT11S
2 lines
(STN monochrome)
160 × 64 dots
Screen size
Larger
Programmable Terminals
NT631/NT31 V2
Touch-screen HMI
Programmable
Terminals
Greater Compatibility with SYSMAC PLCs and
Easy-to-Use Support Software
NT631C
NT31C
Features for Users
Device Monitor Function
I/O memory in the PLC can now be directly accessed to read or write
data. Continuous portions of PLC areas can be displayed. This greatly
increases startup efficiency for setting Special Units or for checking settings. The Device Monitor can be accessed directly from user screens
for applications in monitoring and maintenance screens.
Registration
monitor
Error log
Continuous
monitor
Touch-screen HMI
649
Full Area Access and High-speed NT Links with CS Series
High-speed Links with CS-series PLCs
•
•
•
•
Fastest communications in the industry for serial connection.
Connect up to 8 PTs to a single port.
Communicate to a maximum of 500 m.
Connect up to 8 PTs and still get the same communications speed as
1 PT connected in a standard NT Link.
Accessible Areas in CS-series PLCs (for 1:N NT Links)
PLC
CIO Area
HR Area
AR Area
Timer/Counter present values
DM Area
EM Area (e.g., current EM bank, EM bank 0, or EM
bank C)
Work Bit Area
Task Flags
Timer Completion Flags
Counter Completion Flags
CS1G or CS1H
00000 to 06143
00000 to 00511
00448 to 00959
00000 to 04095
00000 to 32767
00000 to 32767
Faster Access to More Areas
(OMRON Comparison)
Communications Speed for One Unit
Host Link
NT Link
High-speed
NT Link
0.0
00000 to 00511
00000 to 00031
00000 to 04095
00000 to 04095
0.5
1.0
1.5
2.0
2.5
3.0
Communications for Eight Units
NT Link
High-speed
NT Links
0.0
Three times faster!
0.5
1.0
1.5
2.0
2.5
3.0
All measurements were at the RS-232C port on the CPU Unit.
All figures are based on a value of 1 for an NT Link for one Unit.
Features
More Processing and Interlock Functions
Versatile, Enhanced Display Functions
Numeric processing and interlock features can be built into the screens,
greatly reducing the amount of ladder programming required and simplifying program changes, maintenance work, and system upgrading.
(The PT now supports up to 5 items of arithmetic and/or logic processing).
Enhanced Graphs
The enhanced graph function allows precise settings, including indirect
settings for analog meters, trend graphs, sequential line graphs, and
bar graphs.
Multi-window Display Allows Optimum Screen Application
Up to three windows can be displayed simultaneously. A window can
be moved with the touch of a finger. Furthermore, windows can be opened and closed from the PLC using operations in the Window Control
Area.
650
Programmable Terminals
High-definition Fonts
Alarm List for Realtime Error Displays
Display text can be set to from 4 to 16 times normal size and still maintain high definition for easy reading.
Alarm History Helps to Improve Equipment
A history of malfunctions displayed on the screen can be arranged in
order of occurrence or frequency. The history can be referred to at any
time, even during operation, making analyzing machine problems far
easier. The history can also be uploaded to the NT Support Software.
Press "Alarm Message."
Programmable
Terminals
A program will start and display
the details of the error.
Features for Maintenance
System Program Transfers
Functions and performance can be upgraded without changing hardware simply by loading a new system program.
Screen Transfers via Memory Units
Just save the screens to a Memory Unit and essentially anyone can
easily transfer screens. Up to two banks of data can be saved in a
Memory Unit, enabling both screen data and the system program to be
saved to a single Memory Unit
Special Screen Transfer Utility
Essentially anyone can transfer screen data without using the NT Support Tool. The utility is a separate software package and can be set up
separately wherever required.
Screen Verification without PLC Connection
The NT631/NT31 displays screens, such as lamps, touch switches,
and memory table numbers, without the PLC connected, to enable
efficient debugging.
Touch-screen HMI
651
Other Features
Three Communications Ports for Easier Application
Flat, Thin Body
NT631/NT631C
All models are only 54 mm thick with an essentially flat surface. This
makes the PTs fit so much more easily into control panels or machines
and contributes to down-sizing.
Expansion Inteface Connector
IP65F Environment Resistance
Flush surface construction is used for superior environmental resistance to achieve an enclosure rating for the front of the PT of IP65F.
IP → International Protection
6 → Dust and dirt will not enter interior.
(Enclosure protects against foreign objects.)
5 → There are no adverse effects from a water stream from any direction. (Enclosure protects against water intrusion.)
F → There are no harmful effects from oil droplets or spray from any
direction. (Enclosure protects against oil intrusion.)
International Standards
EC Directives, UL, and CSA listings/approvals have all been acquired
for each shipping anywhere in the world.
®
NEMA4 (equivalent)
Protective Cover
Printer Port
RS-422A Port
Easily achieve 1:N RS-422A
or RS-485 communications.
Long-distance
communications are also
possible.
RS-232C Ports
Two RS-232C ports are a standard
feature. Connect directly to a barcode
reader to construct a POP system. Or
connect one to the Support Software and
one to anyother host to make debugging
and maintenance more efficient.
Model numbers
NT31/NT31C
Expansion Interface Connector
Material
Mounting method
NT631C-KBA05 (5 Covers)
NT31C-KBA05 (5 Covers)
Polyethylene film
Double-sided tape
Note: This Protective Cover is designed to protect the screen from the
adhesion of oil, dust, finger marks, etc.
Printer Port
RS-232C Port
RS-232C/RS-422A Port
Can be set to RS-232C using
a memory switch.
652
Programmable Terminals
Specifications
NT631C/NT631
General Specifications
20.4 V DC to 26.4 V DC (24 V DC -15% to +10%)
18 W max.
0 to 50°C
30 W max.
−20 to 60°C35% to 85% (with no condensation)
No corrosive gases
Conforms to IEC61000-4-4, 2 kV (power line)
Conforms to IEC 60068-2- Conforms to IEC 60068-26, JIS C0040.
6, JIS C0040.
10 to 57 Hz with 0.075-mm 10 to 54.8 Hz with 0.075mm amplitude for 30 minamplitude, 57 to 150 Hz
with 1G {9.8 m/s2} acceler- utes in each of X, Y, Z diation for 30 minutes in
rections
each of X, Y, Z directions
Conforms to IEC 60068-2-27, JIS C0041. 147 m/s2
{15G} 3 times in each of X, Y, and Z directions
2.5 kg max.
Front panel: Equivalent to IP65F (NEMA4)*
Performance Specifications
Display Specifications
Specifications
Indicators
Backlight
(with cold
cathode tube)
Life expectancy
Automatic
turn-off
Contrast adjustment
Life expectancy
(at high
brightness)
Replacement
Brightness
adjustment
POWER
(green LED)
RUN
NT631-ST211(B)-EV2
High-contrast EL
Expansion interface
Item
211 mm horizontally × 158 mm vertically (10.4”)
(Not provided)
(Not provided)
30,000 hours minimum*1
---
Can be replaced from the
rear
(Not provided)
-----
Lit while power is being supplied
Lit green: Running normally, Memory unit automatic transmission done
Lit orange: Low battery voltage (during operation)
Lit red: Low battery voltage (when NT631/NT631C is
stopped)
Specification
Conforms to EIA RS-232C
D-Sub 9-pin connector (female)
+5 V (250 mA max.) output at pin No. 6
Switchable between EIA RS-232C and RS-422A/
485 (by memory switch setting)
RS-232C: D-Sub 9-pin connector (female)
RS-422A/485: Terminal block (6 terminals)
Conforms to Centronics standard, 20-pin half
pitch connector
Dedicated connector
Display Specifications (Same for NT631C/631/31C/31)
640 dots horizontal × 480 dots vertical
Up: ±55°
(No restriction)
Down: 55°
Left: 55°
Right: 55°
8 colors (and intermediate Black, white
colors can be displayed with (2 colors)
tiling patterns)
50,000 hours minimum
30,000 hours minimum (until
(until brightness reduced by brightness reduced by 30%)
half)
Can be set to turn off in 1 to 255 minutes, or to remain on
Serial port B
connector
Parallel interface
Character displays
Fixed displays
Character string displays
Numeral displays
Bar graph displays
Analogue meters
Trend graphs
Broken line graphs
Lamps
Image library data
Touch switches
Numeric key inputs
Thumbwheel inputs
Character string inputs
Alarm lists
Alarm histories
Normal screen
Overlapping screens
Specification
65,535 per screen (including marks)
256 per screen (40 bytes (40 characters)
per string)
256 per screen, max. 10-digit display
50 per screen with percentage and sign displays
50 per screen, with percentage and sign displays
1 frame per screen, 50 graphs per screen data file
(8 graphs per screen data file with data logging)
1 frame per screen, 256 graphs per frame,
512 points per graph
256 per screen
256 per screen
256 per screen, 256 mesh overlapping
256 per screen
256 per screen
4 groups per screen
The normal screen display
A maximum of 8 registered screens can be displayed overlapped with each other.
Window screens
Up to 3 screens (2 local windows and 1 global window) can be displayed at the same time.
Display history
Order of occurrence (max. 1024 screens), order of
screens
frequency (max. 255 times)
Screen attributes
Buzzer, display history, background color, backlight, keyboard screen number
Max. number of reg- 3,999 screens
istered screens
Screen No.
0:No display
1 to 3999:User registered screens
9000:Initializing system screen
9001:Display history (occurrence) screen
9002:Display history (frequency) screen
9020:Programming Console function screen
9021:Registration monitor screen
9022:Continuous monitor screen
9023:Error Log screen
9030:Brightness/contrast adjustment screen
9999:Return to the previous screen
Screen registration
By transmitting screen data created using the
method
Support Software to the PT
By transmitting screen data stored in a Memory
Unit to the PT (automatic/manual)
Screen saving method
Flash memory (screen data memory in the PT)
(screen data memory)
Screen types
Display colors
NT631C-ST151(B)-EV2
Color TFT LCD
Serial port A
Number of screens
Display panel
Item
External Interface Specifications
Item
Note: The NT631/NT631C may not be used at a location where it is
exposed to splashing oil for a long period.
Display
device
Number of
dots (resolution)
Effective display area
View angle
Number of switches 768 (32 horizontally × 24 vertically)
Input method
Pressure-sensitive type
Operating force
1 N minimum
Life expectancy
One million operations minimum
Note: 1. Time taken for brightness to reduce to half at normal temperature and humidity
Touch-screen HMI
653
Programmable
Terminals
Shock resistance
(operating)
Weight
Enclosure ratings
NT631-ST211(B)-EV2
Serial
communications
Rated power supply
voltage
Allowable power supply
voltage range
Power consumption
Operating ambient
temperature
Storage ambient
temperature
Operating ambient
humidity
Operating environment
Noise immunity
Vibration resistance
(operating)
Specifications
NT631C-ST151(B)-EV2
24 V DC
Display elements
Item
Touch Panel Specifications
Display Element Specifications
Performance Specifications
Item
Display characters
Display Specifications
Data Capacities
Data
Screen data
Numeral memory tables
String memory tables
Bit memory tables
Mark data
Image data
Library data
Capacity
1 MB
2 words x 2,000 entries (1,000 entries backed up)
40 characters x 2,000 entries (500 read/write)
1 x 1,000 entries
224 marks (calculated for 16 x 16-bit marks)
4,095
12,288
NT31C/NT31
Specifications
Item
Backlight (white
cold cathode tube)
NT31-ST121(B)-EV2
Monochrome STN LCD
Indicators
Specification
• Half-size characters (8×8 dots):
Alphanumerics and symbols
• Standard characters (8×16, 16×32 dots):
Alphanumerics and symbols
• Marks (16×16 dots): User-defined pictographs
Enlargement function Equal, wide, high, 2×2, 3×3, 4×4, 8×8
Smoothing process Characters of 2×2 or larger (except marks)
Character display at- Standard, flash, inverse flash, transparent
tributes
Image data
Variable-size pictographs
Size:8×8 dots min., 640×480 dots max.
The size can be set as required in 8-dot units.
Enlarged display, smoothing processing, and display attributes such as inverse and flash cannot be set.
Library data
Combinations of any graphics
Size: 1×1 dots min., 640×480 dots max.
Any size can be set within this range.
Enlarged display, smoothing processing, and display attributes such as inverse and flash are implemented according to the setting registered.
Graphics
Polyline, circle, arc, sector, rectangle, polygon
Line type
4 types only for polylines (solid line, broken line, alternate
long and short dash, long and two short dashes)
Tiling
10 types
Graphic display atStandard, inverse, flash, inverse flash
tributes
Display colors
NT31, NT631:Two colors (black, white)
NT31C, NT631C: Eight colors (black, blue, red, magenta,
green, cyan, yellow, white)
NT31C-ST141
Display
Colour STN LCD
device
Number
320 dots horizontal × 240 dots vertical
of dots
(resolution)
Effective
118.2 mm horizontally × 89.4 mm vertically (5.7 inches)
display area
View angle Up:20°
Down:30°
Left/right:±30°
Display
Black, white
8 colors
colors
(2 colors)
Life
50,000 hours minimum
expectancy (until brightness reduced by half)
Automatic
Can be set to turn off in 1 to 255 minutes, or to remain on
turn-off
Contrast
Adjustable in 100 levels by operation at touch panel
adjustment
Life
25,000 hours minimum
expectancy (at room temperature, until brightness is reduced to 50%)
(at high
brightness)
ReplaceCan be replaced from the rear
ment
Brightness Adjustable in 3 levels by at touch panel
adjustment
POWER
Lit while power is being supplied
(green LED)
RUN
Lit green: Running normally, Memory unit automatic transmission done
Lit orange: Low battery voltage (during operation)
Lit red: Low battery voltage (when stopped)
Touch Panel Specifications
Number of switches
Input method
Operating force
Life expectancy
192 (16 horizontally × 12 vertically)
Pressure-sensitive type
1 N minimum
One million operations minimum
General Specifications
External Interface Specifications
Item
Rated power supply
voltage
Allowable power supply
voltage range
Power consumption
Operating ambient
temperature
Storage ambient
temperature
Operating ambient
humidity
Operating environment
Noise immunity
Vibration resistance
(operating)
Item
Serial
communications
Shock resistance
(operating)
Weight
Enclosure ratings
654
Specification
24 V DC
Serial port A
20.4 V DC to 26.4 V DC (24 V DC –15% to +10%)
Serial port B
15 W max.
0 to 50°C
Parallel interface
–20 to 60°C
Expansion interface
Specification
Conforms to EIA RS-232C
D-Sub 9-pin connector (female)
+5 V (250 mA max.) output at pin No. 6
EIA RS-232C or RS-422A/485
(selectable by memory switch setting)
D-Sub 25-pin connector (female)
Conforms to Centronics standard,
20-pin half pitch connector
Dedicated connector
35% to 85% (with no condensation)
No corrosive gases
Conforms to IEC61000-4-4, 2 kV (power line)
Conforms to IEC 60068-2-6, JIS C0040.
10 to 57 Hz with 0.075-mm amplitude, 57 to 150 Hz
with 1G {9.8 m/s2} acceleration for 60 minutes in each
of X, Y, Z directions
Conforms to IEC 60068-2-27, JIS C0041. 147 m/s2
{15G} 3 times in each of X, Y, and Z directions
1 kg max.
Front panel: Equivalent to IP65F (NEMA4)*
Programmable Terminals
Dimensions
NT631C/NT631
NT31C/NT31
302.2
183.5
POWER
RUN
POWER
250
237.2
RUN
142
7.5
315
54
195
mm (vertical x horizontal)
Recommended Panel Cutout Dimensions
+0.5
131.0+0.5
0 x 184.0 0 mm (vertical x horizontal)
Programmable
Terminals
x
303.0 +0.50
5
54
Recommended Panel Cutout Dimensions
238.0 +0.5
0
130.5
Touch-screen HMI
655
NT21S
Small touch-screen HMI
L
Cost effective touch screen terminals to
replace function key units and increase the
flexibility and operation.
Features
Effective display area
117 x 63 mm
High-speed NT Links
Two RS-232C ports
Memory Link
Up to 3,999 screens
Supports Memory Units
Concentrated functionality
Mathematical
functions
31 functional parts
•Recipes
•Alarm lists/histories
•Image library
•Trend graphs
•Analog meters
NT20S/NT31
data compatibility
Upgraded NT Support Tool
version (-EV4.6)
•Shares I/O comment data
with CX-Programmer
•Symbol Manager previews
•Copy image library window data
•Individual editing of grouped parts
656
Supports RS-232C/422
Adapter (connector)
Programming Console
function
Barcode Reader
function
Programmable Terminals
Connectable PLCs for Direct Access
Communications
method
Host link (RS-232C)
C200H
C200HS
CU
1:1 NT Link
---
Memory Link (NTH
protocol)
---
CU/CPU
(Note 1)
CPU
(Note 1)
---
C200HX/HG/
HE(-Z)
CU/CPU
(Note 4)
CPU
(Note 4)
---
C1000H/
C2000H
CU
CS1/CJ1
CV/CVM1 V1 CQM1H
CPM1(A)
SRM1
CU/CPU
CU/CPU
CPU
---
---
CPU
CPU
---
---
---
---
CPU
(Note 5)
CPU
(Note 5)
---
Computer/
SBC
---
---
CPU
CPU
(Note 2)
CPU
(Note 3)
---
CPU: Connected to built-in CPU Unit port, CU: Connected to Communications Unit.
Note: 1. The built-in port can be used on the following CPU Unit: C200HS-CPU2@/3@.
2. The built-in port can be used on the following CPU Unit: CQM1H-CPU21/4@.
3. The built-in port can be used on the following CPU Unit: CQM1H-CPU4@.
4. Connection is also possible to a Communications Board. Refer to the communications methods for individual models for details.
5. A CPM1-CIF01 RS-232C Adapter must be purchased separately
General Specifications
Display Capacity
Item
Power supply voltage
Power consumption
Noise resistance
Vibration resistance
Item
Fixed displays
Fixed character
strings
Graphics
Marks
Ambient operating
temperature
Storage temperature
Ambient operating
humidity
Dimensions
Enclosure ratings
Weight
−20 to 70°C (with no icing)
35% to 85% (with no condensation)(0 to 40°C)
35% to 55% (with no condensation)(40 to 50°C)
190 x 110 x 53.5 mm (W x H x D)
(thickness inside panel: 49.0 mm)
Front panel operating section: Equivalent to IP65F,
NEMA 4.*
0.6 kg max.
Number of screens
Screen types
* Usage may not be possible in places where the unit would be
exposed to oil for long periods.
Specification
A total of 65,535 per
With overlapping screens,
screen
the total is 524,280 per
(Graphics: Continuous
screen
straight lines, rectangles,
circles, polygons, arcs,
sectors)
Numeral displays
256 positions per screen, max. 10-digit disply (2
words)
Character string dis- 256 positions per screen max.
plays
1,024 display elements for overlapping screens
Graph displays
50 positions per screen, capable of displaying signs
and percentages
Analog meters
50 positions per screen, capable of displaying signs
and percentages
Trend graphs
One frame per screen, 50 items per frame
(8 items max. for data logging)
Broken line graphs One frame per screen, 256 items per frame, 260 points
per item
Lamps
256 positions per screen
Image library images 256 positions per screen
Touch switches
256 positions per screen, max. 256 meshes
Numeral settings
256 positions per screen Total of 256 positions for
(numerical keypad)
both numerical and thumbwheel settings
Thumbwheel set26 positions per screen
tings
Character string set- 256 positions per screen
tings
Temporary inputs
One position per screen
Alarm lists/histories Four groups per screen
Recipes
One position per screen
Normal screens
Display screens registered as normal
Overlapping screens A maximum of eight screens can be displayed overlapping each other
Windows
Up to three window screens can be displayed
Display history
Order of occurence (1,024 screens max.), order of frescreens
quency (255 times max.)
System startup
Displayed when powering ON (or resetting) the PT,
screen
and when switching to RUN mode
Programming conEmulates PLC programming Console functions, capasole screen
ble of being called from RUN mode.
Screen attributes
Buzzer, display history, normal background colors,
backlight mode, local windows
Max. number of reg- 3,999
istered screens
Screen number
0:
No display
1 to 3999: User registered screens
(normal, overlapping, windows)
9000:
System startup screen
9001:
Display history screens, order of occurence
9002:
Display history screens, order of frequency
9020:
Programming console screen
9021 to 9023, 9030: Reserved
9999:
Return to previous screen designation
Screen registration
By transferring screen data from the NT Support Tool
method
to the PT via serial communications
By mounting the Memory Unit and downloading (automatic/manual transfer) data to the PT
Saving screen data
Flash memory (PT internal image memory)
Display elements
Shock resistance
Specification
24 V DC
7 W max
Conforms to IEC61000-4-4, Power supply line 2 kV
10 to 57 Hz with 0.075 mm single amplitude, 57 to 150
Hz with 9.8 m/s2 acceleration,
for a total of 60 min. in X, Y, and Z directions.
Peak acceleration 15 G
3 times each in X, Y, and Z directions
0 to 50°C (with no icing)
Small touch-screen HMI
657
Programmable
Terminals
Specifications
Display Specifications
NT21 Standard Models
Item
Display Display device
Panel
Number of dots
(resolution)
Effective display
area
Viewing angle
Display color
Service life
Automatic turnOFF
Backlight
Service life
(white cold
cathode tube) Replacement
Product
Specification
Monochrome STN LCD
260 dots horizontally x 140 dots vertically
NT21 Pro- Monochrome STN
grammable
Terminal
117 mm horizontally x 63 mm vertically
Left/right direction: 30°, up/down: 30°
Black & white (with blue mode)
50,000 hours min. (until contrast reduced to 50%)
Can be set to turn OFF in 1 to 255 min or to remain
ON with screen saver
50,000 hours min. (at room temperature, until
brightness is reduced to 50%)
Non-replaceable
Specification
91
(13 horizontally x 7 vertically)
Pressure-sensitive
1 N max.
Frame color: beige
Frame color: black
Support
Tool
Windows 95, 98, ME, NT, or 2000
Cables
For screen transfer
For PLC
PT: 9-pin
connection PLC: 9-pin
Panel Specifications
Item
Touch Number of
panel switches
Input
Threshold force
for operation
Life expectancy
Specification
Options
1 million operations min.
CD-ROM
Cable
length: 2 m
Cable
length: 5 m
PT: 9-pin
Cable
PLC: 25-pin
length: 2 m
Cable
length: 5 m
PT: 9-pin
Cable
PLC: Mini-peripheral
length: 2 m
Cable
length: 5 m
Reflection Protective
Display area only (5
Sheets
sheets)
Chemical-resistive Cover Silicon cover
Battery
For alarm lists/histories
Memory Unit
For screen and system
data transfer
External Interface Specifications
Communication method
NT support Tool
PLC Host Link
1:1 NT Link
1:N NT Links
NT Link, PT Programming Console function
SBC/personal computer Memory Links
Barcode Reader
Serial port A
Supported
Supported
Supported
Supported
Supported
Supported
Supported
Serial port B
Not Supported
Supported
Supported
Supported
Supported
Supported
Not Supported
RS-232C/422A Adapter
Connector Kit
Model number
NT21ST121E
NT21ST121B-E
NTZJCAT1EV4
XW2Z-S002
XW2ZS200T
XW2ZS500T
XW2ZS200S
XW2ZS500S
XW2ZS200T-2
XW2ZS500T-2
NT20MKBA04
NT20SKBA01
C500BAT08
NT-MF161
NS-AL002
XM2S0911-S003
.
Dimensions
178
100 122
53.5
4.5
39 min.
42 max.
Rear panel
110
15.5
28
142
190
Panel thickness: 1.6 to 4.8 mm
Recommended cut-out size:
178.5 +0.5/Ð0 x 100.5 +0.5/Ð0 mm (W x H)
658
19.5
52.5
Programmable Terminals
NT11S
Function-key HMI terminal
The NT11S, the Slim, Low Cost Operation
Terminal that Stands Up Well to Harsh
Environments.
•
•
•
•
Long-lived Backight
Simplified Ladder Programming
Password Screens
Conforms to NEMA4 and IP65
Withstands Water and Oil
• Use in many demanding ares even with oil and water
The front panel of the terminal withstands water to NEMA4 and IP65
standards, which means that it can be used even in locations where it
may be splashed with water or oil.
Large Keys
• For easy operation by all users
The numeric keys and function keys have been made a generous size
for your convenience. They can be operated even when wearing working gloves.
Entry of Numerical Values
The numeric key pad integrated with the display allows the entry of
numerical values such as temperatures and production quantities.
Printout of Production Status
Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report.
(The NT11S has a printer port. One screen only is printed.)
“Direct Connection” Communication
• Simplifies Ladder Programming
The NT11S supports two communication methods: the NT link method,
which substantially reduces the size of the program at the host side,
and the host link direct connection method.
The “NT link” method features a particularly high response speed.
• NT link method
SYSMAC
C200HS–CPU3@/2@
CQM1–CPU4@
• Host link direct connection method
SYSMAC
C200HS–CPU3@/2@
C200H–LK201/–V1
CQM1 (Excludes –CPU11)
Function-key HMI terminal
Integral Numeric Key Pad
The display, numeric keys, and function keys are all integrated into the
front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use.
Password Screens for Security
• To limit access to authorized persons only
Password screens cannot be accessed unless the correct password is
entered. This means that the operations that can be performed can be
restricted according to the operator.
Key Titles can be Marked on the Function Key Sheet
Key titles can be marked on the function key sheet in accordance with
the applications of the keys: the sheet can be taken out from the side
face of the terminal. The front panel of the terminal has a water–withstanding construction.
Bar Graphs can be Displayed
Bar graph displays allow the progress of processes to be checked at a
glance. (The bars are oriented horizontally.)
Display History Record Helps in Analysis of Machine
Faults
When the display history record function is set as a screen attribute, the
time, the screen number, and a comment are recorded in the terminal’s
memory every time the relevant screen is displayed. This display
history can be printed by issuing a print instruction from the host, and is
useful for machine fault analysis.
Screen Operations are Easy
Using the support software, screens to be displayed by the terminal can
be created as easily as if using a word proces-sing program. This software can be run on an IBM PC/AT or compatible. It contains the system
program transfer tool that downloads the system program to the flash
ROM.
Main functions
• Fixed displays, numeral display, character display
• Character inversion, flashing, double–width. Character copy, move, delete.
• 8 x 16 dot mark registration (max. 64 marks can be registered)
• Horizontal bar graphs
• Numeral setting
• Password
659
Programmable
Terminals
Main features
Easy to Order
The front panel is available in beige or black
Since the communication interface, image memory, and flash ROM that
downloads the system program are incorporated in the NT11S body,
placing orders is a simple matter.
Long–lived Backlight
Since LEDs are used for the backlight, it is very long–lived and rarely
needs to be changed.
Specifications
General Specifications
Power supply voltage
Allowable power supply voltage range
Power consumption
Noise resistance
Vibration resistance
Shock resistance
Ambient operating temperature
Ambient operating humidity
Operating environment
Storage temperature
Enclosure ratings
Weight
24 V DC
20.4 to 26.4 V DC (24 V DC –15 %, +10 %)
15 W max.
Common mode (between power supply and panel): 1000 Vp–p
Normal mode: 300 Vp–p
Pulse width: 100 ns to 1 ms Pulse rise time: 1 ns
10 to 22 Hz with 1.5 mm double amplitude in X, Y, and Z directions.
22 to 500 Hz with 1.5 G {14.7 m/s 2 } acceleration for a total of 30min. in X, Y, and Z directions.
20 G {196 m/s 2 } 3 times each in X, Y, and Z directions.
0 to +50 _C
35 to 85 % RH (with no condensation)
No corrosive gases.
–20 to +70 _C (with no freezing)
Front panel: Equivalent to IP65, NEMA4
1.0 kg max.
Display/Panel Specifications
Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
Display screen
Dot matrix of STN liquid crystal display panel
- Number of dots: 160x64
- Effective display area: 100 40 mm
- Life expectancy: 50,000 hours minimum
- View angle (left/right direction): ±20°
Backlight
- LED
- Life expectancy: 10,000 hours minimum (average:
30,000 hours)
- Automatic turn–off: can be set to turn off in 10 minutes or 1 hour, or to remain on.
- POWER indicator (Green LED): Lit while power is being supplied.
- RUN indicator (Green LED): Lit during operation
- 22 switches
- Life expectancy: 1 million operations minimum
Indicators
Switch
Display Capacity
Note: Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice.
Display characters
Number of characters
Enlargement function
Display
elements
Screen attributes
Character string displays
Numeral displays
Graph displays
Numeral settings
Display history
Password screen
Menu screen
Screen types
Max. number of registered screens
Screen registration method
Screen saving method
Normal characters (8 16 dots): Alphanumerics and symbols
Marks (8 16 dots): User–defined, 64 max.
displayed Normal–size: 20 horizontally 4 lines vertically max.
Double width
8 positions per screen
8 positions per screen
4 positions per screen
8 positions per screen
Order of frequency, 256 screens
Ensures security: screens for which this attribute is set can only be displayed if the correct password is input.
Four items per screen
Normal screen: Displays screen registered as normal.
250
Transfer screen data created using an IBM PC/AT personal computer to the PT.
Saved to flash memory: 32KB (downloading method)
Special Features
Printing function
Printing of display history data
Printing of daily reports (printing format registered by the users)
Self–test for memory, switches, etc.
Status setting confirmation for communications and other conditions.
Simple communications confirmation
Maintenance functions
.
Ordering Information
Product
Programmable
Terminal
Support Software
660
Specification
Host link direct connection, Ten–key type (frame color: beige)
NT link method
Ten–key type (frame color: black)
3.5” FD (for IBM PC/AT)
Model
NT11S–SF121
NT11S–SF121B
NT11S–ZA3AT–EV1
Programmable Terminals
Dimensions
203
113
98
7.5
218
38.2
45.3
63.7
22.8
86.2
34.2
Programmable
Terminals
51
76
71
Function-key HMI terminal
661
NT2S
Small Function Key Terminals
The NT2S series Terminals are designed
as a human machine interface for simple control
tasks. Their small dimensions and low installation
depths ensure that they
will fit into any machine.
Of the six NT2S types, four can be connected directly
to the peripheral port and two can be connected to
OMRON PLCs via an RS-232C port.
•
•
•
•
•
•
Easy programming
Small size and installation depth
IP65 protection
Real-time clock
Printer connection
Excellent value for money
Performance Data (Max. Values)
Max. screen pages
NT2S-SF121B-EV2
Yes
109x60x36 mm
56x11 mm
5x7 pixel/character
2/16
6
24 kB for applications
250
NT2S-SF125B-E
Yes
107x107x36
56x11 mm
5x7 pixel/character
2/16
20
24 kB for applications
250
NT2S-SF122B-EV2
Yes
109x60x36 mm
56x11 mm
5x7 pixel/character
2/16
6
24 kB for applications
250
NT2S-SF126B-E
Yes
107x107x36
56x11 mm
5x7 pixel/character
2/16
20
24 kB for applications
250
Number input
Bar graph
Trend/line diagram
Alarm handling
Real-time clock/date
Printer interface
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes (RS-232C)
-
Yes (RS-232C)
-
Yes (peripheral port)
-
Programmable
Terminal size (W,H,D)
Display size
Number of screen pixels
Number of lines/characters
Number of function/control keys
Memory
NT2S-SF123B-EV2
No (PLC controlled)
109x60x36 mm
56x11 mm
5x7 pixel/character
2/16
6
PLC memory is used
NT2S-SF127B-E
No (PLC controlled)
107x107x36
56x11 mm
5x7 pixel/character
2/16
20
PLC memory is used
Yes
Yes
Yes
Depending on PLC
memory
Yes
Yes
-
Depending on PLC
memory
Yes
Yes
-
Yes (peripheral port)
-
Yes (peripheral port)
-
Yes (peripheral port)
-
Communication
Host Link
1:1 NT Link
1:n NT Link
ASCII protocol
662
Programmable Terminals
System Configuration
Host Link
Data is exchanged quickly between the Control
Terminal and an OMRON PLC using the Host Link
protocol.
The RS-232C communication method can be used.
The following OMRON PLC systems feature the
Host Link protocol:
- CPM1 family
- CPM2 family
- CQM1 family
- CJ1
- CS1
Miniature Peripheral
port
NT2S-SF121B
NT2S-CN223-V1
for CS1,CJ1, CQM1H
CS1
RS232C port
CJ1
RS-232C cable
for CPM1A, CPM2C
(CIF adapter required)
NT2S-SF125B
Peripheral port
CQM1H
NT2S-CN212/215
for CPM1A, CPM2A
CPM2C
Programmable
Terminals
CPM2A
CPM1A
Power supply: 24 VDC, external
Miniature peripheral
port
NT2S-SF122B
NT2S-SF123B
NT2S-CN224-V1
CS1
CJ1
NT2S-SF126B
NT2S-SF127B
CQM1H
CPM2C
Peripheral port
NT2S-CN222-V1
NT2S-CN225-V1
CPM2A
CPM1A
Power supply: from the PLC, via port connection
Small Function Key Terminals
663
Product Overview
Model code
Display size (WxHxD)
Number of screen pixels
Number of lines/characters
Number of function/control keys
Memory
Supply voltage
Degree of protection
NT2S-SF121B-EV2 NT2S-SF125B-E
- Programmable using software
- Real-time clock
- Printer port
- PLC connection via RS-232C port
- Supply voltage 24 V
108x60x43 mm
108x108x43 mm
5x7 pixel/character
2/16
2/16
6
20
24 kB Flash memory for applications
24 V DC
24 V DC
IP65F (front side)
NT2S-SF122B-EV2 NT2S-SF126B-E
- Programmable using software
- Printer port
- PLC connection via peripheral port
- Supply voltage connection via peripheral
port
108x60x43 mm
108x108x43 mm
NT2S-SF121B-EV2 NT2S-SF125B-E
NT2S-SF122B-EV2 NT2S-SF126B-E
2/16
6
2/16
20
NT2S-SF123B-EV2 NT2S-SF127B-E
- Functions are controlled using the PLC
- PLC connection via peripheral port
- Supply voltage connection via peripheral
port
108x60x43 mm
108x108x43 mm
2/16
2/16
6
20
PLC memory is used
---
Specifications
Model code
Function keys
Key type
Key function
Display elements
Characters
Image colours
Character display attributes
Display specification
Display
Function displays
Display capacity
String display
Numeric display
Bar graph display
Character string input
Alarm list
Time display
Screen page
Number of stored screen pages
Screen page numbers
Storing of screen pages
General
Battery backup
Supply voltage
Power consumption
Immunity
NT2S-SF123B-EV2 NT2S-SF127B-E
Membrane keyboard
As well as fixed or system functions, functions can be assigned dynamically using software (Softkeys), while global, i.e. screenindependent, keys can also be defined
5x7 pixel/character
Monochrome
Normal, flashing (entire screen)
- LED backlit LCD Module, 2x16 characters, 5x7 pixel/character
- Character size 4.35 mm
- Extended ASCII character set (semi-graphic)
2 status LEDs1, programmable via PLC
Entire display area can be used
Entire display area can be used
Entire display area can be used
Either by output from Controller real-time From Controller
clock or output from Terminal's integrated
real-time clock
Max. 250
1..250
Transfer of data from a PC to the Terminal
All programming in the PLC
Data backup in EEPROM
10..30 V DC
via PLC
approx. 1.5 W
Between power supply and panel: 1700 Vss
Normal:
480 Vss
Pilse width
100 ns..1 µs
Pulse rise time
1 ns
10..61.2 Hz with 0.1 mm amplitude
61.2..150 Hz with an acceleration of 1.5 g in X, Y and Z directions 4 times for 8 minutes each
147 m/s², 3x in X, Y and Z directions
0 °C..50 °C
35%..85%
No corrosive gases
-20 °C..60 °C
Front side: IP65F, Rear side: IP20
CE, c-UL
150 g
230 g
135 g
205 g
130 g
Vibration resistance
(in operation)
Shock resistance (in operation)
Ambient temperature
Ambient humidity
Operating environment
Storage temperature
Degree of protection
Approvals
Weight
Host Link Direct communication
Communication method
RS-232C or Peripheral port
Peripheral port
Communication protocol
C series SYSWAY (1:1)
Communication settings
Start/stop synchronisation Communication speed: 9600 bps
Data length:
7 bits
Stop bit:
2 bits
Parity:
even
Connection
1 x 9-pin D-Sub female for PLC
1 x 9-pin D-Sub male for PLC
1 x 9-pin D-Sub female for PC/Printer,
1 x 9-pin D-Sub female for PC/Printer
SW download/printer
Number of devices
1
Printer
Communication method
ASCII protocol printer
Connection
Serial RS-232C port
200 g
1x9-pin D-sub male for PLC
No
No
1. The NT2S-SF125/126/127B-E do not have status LEDs
664
Programmable Terminals
Programming and Accessories
Programming
Accessories,
cables etc.
Description
NT Shell. Programming software for Control Terminals.
For WINDOWS 95/98/ME/2000/NT4.0-SP5
see page 454
Connecting cable,
NT2S SF121B / SF125B PLC (peripheral port)
Cable length
-
Model code
NT Shell
2m
5m
Connecting cable,
2m
NT2S SF122B / SF123B / SF126B / SF127B PLC (peripher- 5 m
al port)
Connecting cable,
2m
NT2S-SF121B / SF125B PLC (miniature peripheral port)
Connecting cable,
2m
NT2S-SF122 / SF123B / SF126B / SF127B PLC (miniature
peripheral port)
Adapter cable,
2m
miniature peripheral port PLC (peripheral port)
NT2S-CN212
NT2S-CN215
NT2S-CN222-V1
NT2S-CN225-V1
NT2S-CN223-V1
NT2S-CN224-V1
CS1W-CN114
Dimensions (mm)
NT2S-SF121B-EV2
NT2S-SF122B-EV2
NT2S-SF123B-EV2
60
Programmable
Terminals
43
27
109
92
NT2S-SF125B-E
NT2S-SF126B-E
NT2S-SF127B-E
107
107
93
27
92
Small Function Key Terminals
665
NT-AL001
RS-232C/RS-422A Adapter
The NT-AL001 converts signals between
RS-232C and RS-422A.
Use the NT-AL001 to connect 1:N NT Link
communications, to connect to multivendor
communications, or anytime signal
conversion is required.
Specifications
General Specifications
RS-232C Interface
Item
Model number
Ambient operating temperature
Ambient operating humidity
Rated power supply voltage
Rated power supply current
Surge current
Insulation resistance
Item
Baud rate
Transmission distance
Connector
Specification
NT-AL001
0 to 55°C
10% to 90% (with no condensation)
+5 V ±10% (supplied from pin 6 of RS-232C connector)
150 mA max.
0.8 mA max.
20 MΩ min. (at 500 V DC) between RS-422A signal
lines and functional ground terminal
Dielectric strength
1,500 V AC between RS-422A signal lines and functional ground terminal for 1 min, leakage current: 10
mA max.
Operating environment No corrosive gases
Ambient storage temper- −20 to 75°C
ature
Vibration resistance
Conforms to JISC 0911, 80 min each in X, Y, and Z
directions
Shock resistance
Conforms to JISC 0912, 15G for 3 times each in X, Y,
and Z directions
Weight
200 g
666
Specification
64 kbps max.
2 m max.
D-Sub, 9-pin connector (female)
RS-422A Interface
Item
Baud rate
Transmission distance
Terminals
Specification
64 kbps max. (depends on RS-232C baud rate)
500 m max.
8-terminal removable terminal block, M3.0 terminals
Programmable Terminals
Dimensions
RS-422A terminals
53.5
110
RS-232C connector
OMRON NT-AL001
4
74.5
100.2
105 max.
(30)
45
30
(Unit: mm)
30 x 114 x 100.2 mm (W x H x D) with RS-422A terminal cover removed.
Programmable
Terminals
30 x 114 x 119.5 mm (W x H x D) with RS-422A terminal cover in place.
RS-232C/RS-422A Adapter
667
Ordering Information
PTs
NS Series
Name
NS12
Specifications
TFT, 12”, 800 x 600 dots
Without Ethernet
With Ethernet
NS10
TFT, 10”, 640 x 480 dots
Without Ethernet
With Ethernet
NS8
TFT, 8”, 640 x 480 dots
Without Ethernet
With Ethernet
NS5
STN, 5.7“, 320 x 240 dots
Without Ethernet
With Ethernet
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Model
NS12-TS00
NS12-TS00B
NS12-TS01
NS12-TS01B
NS10-TV00
NS10-TV00B
NS10-TV01
NS10-TV01B
NS8-TV00
NS8-TV00B
NS8-TV01
NS8-TV01B
NS5-SV00
NS5-SV00B
NS5-SV01
NS5-SV01B
NT Series
Name
NT631
Specifications
TFT color
NT21S
STN monochrome
NT11
STN monochrome
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Frame color: Beige
Frame color: Black
Ten–key type
NT2S
LCD monochrome
Programmable
EL
NT31
STN color
STN monochrome
PLC controlled
Programmable
Frame color: Beige
Frame color: Black
6-key type,
Frame color: Black
20-key type,
Frame color: Black
PLC controlled
Model
NT631C-ST151
NT631C-ST151B
NT631-ST211
NT631-ST211B
NT31C-ST141
NT31C-ST141B
NT31-ST121
NT31-ST121B
NT21-ST121E
NT21-ST121B
NT11S–SF121
NT11S–SF121B
NT2S-SF121B
NT2S-SF122B
NT2S-SF123B
NT2S-SF125B
NT2S-SF126B
NT2S-SF127B
Support Software
NS-series PTs
Name
NS-series Screen Design Software for Windows
Cable to transfer screens
Specifications
For NS-series PTs
Windows 95, 98, Me, 2000, XP, or NT 4.0
IBM PC/AT or compatible
Model
NS-NSDC1
Specifications
For NT-series PTs
Windows 95, 98, Me, 2000 or NT 4.0
For NT31, NT31C, NT631, or NT631C
To print hardcopies of screens
Model
NT-Shell
XW2Z-S00S
NT-series PTs
Name
NT-series Support Software for Windows
Memory Unit to transfer screens
Printer cable for NT Series
668
NT-MF261
NT-CNT121
Programmable Terminals
Options
Specifications
1 CD-ROM
For NS Series
Ladder Monitor applications
(See note 1.) and I/O Comment
File Creation Tool (See note 2.)
RS-232C/RS-422A Adapter
Reflective Protective Sheets
(front only, 5 sheets in a set)
Protective Covers
(5 covers in a set)
Memory Cards
8 MB
15 MB
30 MB
48 MB
Memory Card Adapter
Battery
A Memory Card must be purchased separately to
operation on the NS-series PT. A HMC-AP001
Memory Card Adapter is required to write data
from the CD-ROM to a Memory Card on a personal computer.
For NS Series
For NS10/NS12
For NS7
For NS10/NS12
For NS7
For NS Series
For NS Series
For NS10/NS12
For NS7
For NT631/NT31
For NT631C/NT631
For NT31C/NT31
For NT20S
For NT631C/NT631
For NT31C/NT31
For NT631C/NT631
For NT31C/NT31
For NT631C-ST151(B)-EV2
For NT631C-ST141(B)-EV2
For NT31C/NT31
For NT20S
Refer to the Barcode Reader catalog for details.
For CV-series, C200HS, C1000H, and C500 PLCs
DeviceNet Interface Unit
Reflective Protective Sheets
(front only, 5 sheets in a set)
Protective Covers
(5 covers in a set)
Chemically Resistive Covers
(5 covers in a set)
Replacement Backlights
Barcode Reader
RS-232C/RS-422A Adapter
Model
NS-EXT01
NS-EXT01-L03
(3 licenses)
NS-EXT01-L10
(10 licenses)
NS-EXT01-HMC
(with 48-MB Memory Card)
NS-AL002
NS12-KBA04
NS7-KBA04
NS12-KBA05
NS7-KBA05
HMC-EF861
HMC-EF171
HMC-EF371
HMC-EF571
HMC-AP001
C500-BAT08
CPM2A-BAT01
NT-DRT21
NT610C-KBA04
NT30-KBA04
NT20M-KBA04
NT631C-KBA05
NT31C-KBA05
NT625-KBA01
NT30-KBA01
NT631C-CFL01
NT631C-CFL02
NT31C-CFL01
NT20S-CFL01
V520-RH21-6
NT-AL001
Programmable
Terminals
Name
Ladder Monitor Software
Note: 1. This application for the NS-series PT enables monitoring ladder programs in SYSMAC CS/CJ-series PLCs on the PT.
2. This software extracts I/O comment data from CXT files from the CX-Programmer and converts them for ladder monitoring.
PT-PLC Connecting Cables
Communications method
Cable
Host Link, 1:1 NT Link (D-Sub, Host Link Cable
9-pin; D-Sub, 25-pin; or peripheral)
SYSMAC PLC connector
D-Sub, 9-pin
PT connector
D-Sub, 9-pin
D-Sub, 25-pin
D-Sub, 25-pin
D-Sub, 9-pin
CS1, CJ1, or CQM1H periph- D-Sub, 9-pin
eral port
Cable length
2m
5m
2m
5m
2m
5m
2m
5m
70 cm
2m
2m
5m
Model
XW2Z-200T
XW2Z-500T
XW2Z-200S
XW2Z-500S
XW2Z-200P
XW2Z-500P
XW2Z-200T-2
XW2Z-500T-2
XW2Z-070T-1
XW2Z-200T-1
NT2S-CN212
NT2S-CN215
1:N NT Link for connection of
multiple PTs
NT-A001-to-PT Cable
D-Sub, 9-pin
(on NT-AL001)
D-Sub, 9-pin
NT2S-SF121 and 125 to
CPM1A, CPM2A PLC peripheral port
NT2S-SF122, 123, 126 and
127 to CPM1A, CPM2A PLC
peripheral port.
NT2S-SF121 and 125 to CJ1,
CS1, CQM1H, PLC peripheral
port.
NT2S-SF122, 123, 126 and
127 to CJ1, CS1, CQM1H, PLC
peripheral port.
Adapter
Host link to NT2 connecting
cables
peripheral port
NT2S SF121B / SF125B
Host link to NT2 connecting
cables
peripheral port
NT2S SF122B / SF123B /
SF126B / SF127B
2m
5m
NT2S-CN222-V1
NT2S-CN225-V1
Connecting cable
miniature peripheral port
NT2S-SF121B / SF125B
2m
NT2S-CN223-V1
Host link to NT2 connecting
cables
miniature peripheral port
NT2S-SF122 / SF123B /
SF126B / SF127B
2m
NT2S-CN224-V1
Adapter cable
peripheral port
miniature peripheral port
2m
CS1W-CN114
Note: Refer to the product manuals for cables other than those listed above.
669
ALL DIMENSIONS SHOWN ARE IN MILLIMETERS.
To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527.
Cat. No. V02E-EN-01
In the interest of product improvement, specifications are subject to change without notice.