0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
NT31C-CN522-EU

NT31C-CN522-EU

  • 厂商:

    OMRON(欧姆龙)

  • 封装:

    -

  • 描述:

    CABLE 25-9PIN NT TO GE PLC 5M

  • 数据手册
  • 价格&库存
NT31C-CN522-EU 数据手册
Programmable Terminals As an machine management tool ... as an information terminal ... as a system component As a global supplier of HMI solutions and high-reliability industrial touch screen technology for over 12 years, Omron has supplied more than 500,000 pieces of HMI through more than 200 world-wide sales and support offices each offering after-sales support, service and training in the local language. We also understand the changing needs of our customers. As control systems become more complex the HMI is increasingly being used not only as an operator display and data-setting terminal, but also as a maintenance tool for the complete control system. Many HMI applications now contain 100’s of screens of maintenance information for the complete control system and Omron's easy software and hardware integration within the control system can greatly reduce programming time needed and also greatly increase the functionality of the maintenance, therefore dramatically reducing the total cost of ownership. Higher Select by screen size. Select by functions. The wide array of NT- and NS-series PTs suits most applications. NS5(STN) NS8(TFT) 320 × 240 dots NS10 (TFT) 640 × 480 dots Functionality 640 × 480 dots NS12 (TFT) 800 × 600 dots NT631C (TFT/STN color) 640 × 480 dots NT31C (STN color) 320 × 240 dots NT631 (EL) 640 × 480 dots NT31 (STN monochrome) 320 × 240 dots NT21S Lower (STN monochrome) 260 × 140 dots Smaller 636 NT2S NT11S 2 lines (STN monochrome) 160 × 64 dots Screen size Larger Programmable Terminals NT631/NT31 V2 Touch-screen HMI Programmable Terminals Greater Compatibility with SYSMAC PLCs and Easy-to-Use Support Software NT631C NT31C Features for Users Device Monitor Function I/O memory in the PLC can now be directly accessed to read or write data. Continuous portions of PLC areas can be displayed. This greatly increases startup efficiency for setting Special Units or for checking settings. The Device Monitor can be accessed directly from user screens for applications in monitoring and maintenance screens. Registration monitor Error log Continuous monitor Touch-screen HMI 649 Full Area Access and High-speed NT Links with CS Series High-speed Links with CS-series PLCs • • • • Fastest communications in the industry for serial connection. Connect up to 8 PTs to a single port. Communicate to a maximum of 500 m. Connect up to 8 PTs and still get the same communications speed as 1 PT connected in a standard NT Link. Accessible Areas in CS-series PLCs (for 1:N NT Links) PLC CIO Area HR Area AR Area Timer/Counter present values DM Area EM Area (e.g., current EM bank, EM bank 0, or EM bank C) Work Bit Area Task Flags Timer Completion Flags Counter Completion Flags CS1G or CS1H 00000 to 06143 00000 to 00511 00448 to 00959 00000 to 04095 00000 to 32767 00000 to 32767 Faster Access to More Areas (OMRON Comparison) Communications Speed for One Unit Host Link NT Link High-speed NT Link 0.0 00000 to 00511 00000 to 00031 00000 to 04095 00000 to 04095 0.5 1.0 1.5 2.0 2.5 3.0 Communications for Eight Units NT Link High-speed NT Links 0.0 Three times faster! 0.5 1.0 1.5 2.0 2.5 3.0 All measurements were at the RS-232C port on the CPU Unit. All figures are based on a value of 1 for an NT Link for one Unit. Features More Processing and Interlock Functions Versatile, Enhanced Display Functions Numeric processing and interlock features can be built into the screens, greatly reducing the amount of ladder programming required and simplifying program changes, maintenance work, and system upgrading. (The PT now supports up to 5 items of arithmetic and/or logic processing). Enhanced Graphs The enhanced graph function allows precise settings, including indirect settings for analog meters, trend graphs, sequential line graphs, and bar graphs. Multi-window Display Allows Optimum Screen Application Up to three windows can be displayed simultaneously. A window can be moved with the touch of a finger. Furthermore, windows can be opened and closed from the PLC using operations in the Window Control Area. 650 Programmable Terminals High-definition Fonts Alarm List for Realtime Error Displays Display text can be set to from 4 to 16 times normal size and still maintain high definition for easy reading. Alarm History Helps to Improve Equipment A history of malfunctions displayed on the screen can be arranged in order of occurrence or frequency. The history can be referred to at any time, even during operation, making analyzing machine problems far easier. The history can also be uploaded to the NT Support Software. Press "Alarm Message." Programmable Terminals A program will start and display the details of the error. Features for Maintenance System Program Transfers Functions and performance can be upgraded without changing hardware simply by loading a new system program. Screen Transfers via Memory Units Just save the screens to a Memory Unit and essentially anyone can easily transfer screens. Up to two banks of data can be saved in a Memory Unit, enabling both screen data and the system program to be saved to a single Memory Unit Special Screen Transfer Utility Essentially anyone can transfer screen data without using the NT Support Tool. The utility is a separate software package and can be set up separately wherever required. Screen Verification without PLC Connection The NT631/NT31 displays screens, such as lamps, touch switches, and memory table numbers, without the PLC connected, to enable efficient debugging. Touch-screen HMI 651 Other Features Three Communications Ports for Easier Application Flat, Thin Body NT631/NT631C All models are only 54 mm thick with an essentially flat surface. This makes the PTs fit so much more easily into control panels or machines and contributes to down-sizing. Expansion Inteface Connector IP65F Environment Resistance Flush surface construction is used for superior environmental resistance to achieve an enclosure rating for the front of the PT of IP65F. IP → International Protection 6 → Dust and dirt will not enter interior. (Enclosure protects against foreign objects.) 5 → There are no adverse effects from a water stream from any direction. (Enclosure protects against water intrusion.) F → There are no harmful effects from oil droplets or spray from any direction. (Enclosure protects against oil intrusion.) International Standards EC Directives, UL, and CSA listings/approvals have all been acquired for each shipping anywhere in the world. ® NEMA4 (equivalent) Protective Cover Printer Port RS-422A Port Easily achieve 1:N RS-422A or RS-485 communications. Long-distance communications are also possible. RS-232C Ports Two RS-232C ports are a standard feature. Connect directly to a barcode reader to construct a POP system. Or connect one to the Support Software and one to anyother host to make debugging and maintenance more efficient. Model numbers NT31/NT31C Expansion Interface Connector Material Mounting method NT631C-KBA05 (5 Covers) NT31C-KBA05 (5 Covers) Polyethylene film Double-sided tape Note: This Protective Cover is designed to protect the screen from the adhesion of oil, dust, finger marks, etc. Printer Port RS-232C Port RS-232C/RS-422A Port Can be set to RS-232C using a memory switch. 652 Programmable Terminals Specifications NT631C/NT631 General Specifications 20.4 V DC to 26.4 V DC (24 V DC -15% to +10%) 18 W max. 0 to 50°C 30 W max. −20 to 60°C35% to 85% (with no condensation) No corrosive gases Conforms to IEC61000-4-4, 2 kV (power line) Conforms to IEC 60068-2- Conforms to IEC 60068-26, JIS C0040. 6, JIS C0040. 10 to 57 Hz with 0.075-mm 10 to 54.8 Hz with 0.075mm amplitude for 30 minamplitude, 57 to 150 Hz with 1G {9.8 m/s2} acceler- utes in each of X, Y, Z diation for 30 minutes in rections each of X, Y, Z directions Conforms to IEC 60068-2-27, JIS C0041. 147 m/s2 {15G} 3 times in each of X, Y, and Z directions 2.5 kg max. Front panel: Equivalent to IP65F (NEMA4)* Performance Specifications Display Specifications Specifications Indicators Backlight (with cold cathode tube) Life expectancy Automatic turn-off Contrast adjustment Life expectancy (at high brightness) Replacement Brightness adjustment POWER (green LED) RUN NT631-ST211(B)-EV2 High-contrast EL Expansion interface Item 211 mm horizontally × 158 mm vertically (10.4”) (Not provided) (Not provided) 30,000 hours minimum*1 --- Can be replaced from the rear (Not provided) ----- Lit while power is being supplied Lit green: Running normally, Memory unit automatic transmission done Lit orange: Low battery voltage (during operation) Lit red: Low battery voltage (when NT631/NT631C is stopped) Specification Conforms to EIA RS-232C D-Sub 9-pin connector (female) +5 V (250 mA max.) output at pin No. 6 Switchable between EIA RS-232C and RS-422A/ 485 (by memory switch setting) RS-232C: D-Sub 9-pin connector (female) RS-422A/485: Terminal block (6 terminals) Conforms to Centronics standard, 20-pin half pitch connector Dedicated connector Display Specifications (Same for NT631C/631/31C/31) 640 dots horizontal × 480 dots vertical Up: ±55° (No restriction) Down: 55° Left: 55° Right: 55° 8 colors (and intermediate Black, white colors can be displayed with (2 colors) tiling patterns) 50,000 hours minimum 30,000 hours minimum (until (until brightness reduced by brightness reduced by 30%) half) Can be set to turn off in 1 to 255 minutes, or to remain on Serial port B connector Parallel interface Character displays Fixed displays Character string displays Numeral displays Bar graph displays Analogue meters Trend graphs Broken line graphs Lamps Image library data Touch switches Numeric key inputs Thumbwheel inputs Character string inputs Alarm lists Alarm histories Normal screen Overlapping screens Specification 65,535 per screen (including marks) 256 per screen (40 bytes (40 characters) per string) 256 per screen, max. 10-digit display 50 per screen with percentage and sign displays 50 per screen, with percentage and sign displays 1 frame per screen, 50 graphs per screen data file (8 graphs per screen data file with data logging) 1 frame per screen, 256 graphs per frame, 512 points per graph 256 per screen 256 per screen 256 per screen, 256 mesh overlapping 256 per screen 256 per screen 4 groups per screen The normal screen display A maximum of 8 registered screens can be displayed overlapped with each other. Window screens Up to 3 screens (2 local windows and 1 global window) can be displayed at the same time. Display history Order of occurrence (max. 1024 screens), order of screens frequency (max. 255 times) Screen attributes Buzzer, display history, background color, backlight, keyboard screen number Max. number of reg- 3,999 screens istered screens Screen No. 0:No display 1 to 3999:User registered screens 9000:Initializing system screen 9001:Display history (occurrence) screen 9002:Display history (frequency) screen 9020:Programming Console function screen 9021:Registration monitor screen 9022:Continuous monitor screen 9023:Error Log screen 9030:Brightness/contrast adjustment screen 9999:Return to the previous screen Screen registration By transmitting screen data created using the method Support Software to the PT By transmitting screen data stored in a Memory Unit to the PT (automatic/manual) Screen saving method Flash memory (screen data memory in the PT) (screen data memory) Screen types Display colors NT631C-ST151(B)-EV2 Color TFT LCD Serial port A Number of screens Display panel Item External Interface Specifications Item Note: The NT631/NT631C may not be used at a location where it is exposed to splashing oil for a long period. Display device Number of dots (resolution) Effective display area View angle Number of switches 768 (32 horizontally × 24 vertically) Input method Pressure-sensitive type Operating force 1 N minimum Life expectancy One million operations minimum Note: 1. Time taken for brightness to reduce to half at normal temperature and humidity Touch-screen HMI 653 Programmable Terminals Shock resistance (operating) Weight Enclosure ratings NT631-ST211(B)-EV2 Serial communications Rated power supply voltage Allowable power supply voltage range Power consumption Operating ambient temperature Storage ambient temperature Operating ambient humidity Operating environment Noise immunity Vibration resistance (operating) Specifications NT631C-ST151(B)-EV2 24 V DC Display elements Item Touch Panel Specifications Display Element Specifications Performance Specifications Item Display characters Display Specifications Data Capacities Data Screen data Numeral memory tables String memory tables Bit memory tables Mark data Image data Library data Capacity 1 MB 2 words x 2,000 entries (1,000 entries backed up) 40 characters x 2,000 entries (500 read/write) 1 x 1,000 entries 224 marks (calculated for 16 x 16-bit marks) 4,095 12,288 NT31C/NT31 Specifications Item Backlight (white cold cathode tube) NT31-ST121(B)-EV2 Monochrome STN LCD Indicators Specification • Half-size characters (8×8 dots): Alphanumerics and symbols • Standard characters (8×16, 16×32 dots): Alphanumerics and symbols • Marks (16×16 dots): User-defined pictographs Enlargement function Equal, wide, high, 2×2, 3×3, 4×4, 8×8 Smoothing process Characters of 2×2 or larger (except marks) Character display at- Standard, flash, inverse flash, transparent tributes Image data Variable-size pictographs Size:8×8 dots min., 640×480 dots max. The size can be set as required in 8-dot units. Enlarged display, smoothing processing, and display attributes such as inverse and flash cannot be set. Library data Combinations of any graphics Size: 1×1 dots min., 640×480 dots max. Any size can be set within this range. Enlarged display, smoothing processing, and display attributes such as inverse and flash are implemented according to the setting registered. Graphics Polyline, circle, arc, sector, rectangle, polygon Line type 4 types only for polylines (solid line, broken line, alternate long and short dash, long and two short dashes) Tiling 10 types Graphic display atStandard, inverse, flash, inverse flash tributes Display colors NT31, NT631:Two colors (black, white) NT31C, NT631C: Eight colors (black, blue, red, magenta, green, cyan, yellow, white) NT31C-ST141 Display Colour STN LCD device Number 320 dots horizontal × 240 dots vertical of dots (resolution) Effective 118.2 mm horizontally × 89.4 mm vertically (5.7 inches) display area View angle Up:20° Down:30° Left/right:±30° Display Black, white 8 colors colors (2 colors) Life 50,000 hours minimum expectancy (until brightness reduced by half) Automatic Can be set to turn off in 1 to 255 minutes, or to remain on turn-off Contrast Adjustable in 100 levels by operation at touch panel adjustment Life 25,000 hours minimum expectancy (at room temperature, until brightness is reduced to 50%) (at high brightness) ReplaceCan be replaced from the rear ment Brightness Adjustable in 3 levels by at touch panel adjustment POWER Lit while power is being supplied (green LED) RUN Lit green: Running normally, Memory unit automatic transmission done Lit orange: Low battery voltage (during operation) Lit red: Low battery voltage (when stopped) Touch Panel Specifications Number of switches Input method Operating force Life expectancy 192 (16 horizontally × 12 vertically) Pressure-sensitive type 1 N minimum One million operations minimum General Specifications External Interface Specifications Item Rated power supply voltage Allowable power supply voltage range Power consumption Operating ambient temperature Storage ambient temperature Operating ambient humidity Operating environment Noise immunity Vibration resistance (operating) Item Serial communications Shock resistance (operating) Weight Enclosure ratings 654 Specification 24 V DC Serial port A 20.4 V DC to 26.4 V DC (24 V DC –15% to +10%) Serial port B 15 W max. 0 to 50°C Parallel interface –20 to 60°C Expansion interface Specification Conforms to EIA RS-232C D-Sub 9-pin connector (female) +5 V (250 mA max.) output at pin No. 6 EIA RS-232C or RS-422A/485 (selectable by memory switch setting) D-Sub 25-pin connector (female) Conforms to Centronics standard, 20-pin half pitch connector Dedicated connector 35% to 85% (with no condensation) No corrosive gases Conforms to IEC61000-4-4, 2 kV (power line) Conforms to IEC 60068-2-6, JIS C0040. 10 to 57 Hz with 0.075-mm amplitude, 57 to 150 Hz with 1G {9.8 m/s2} acceleration for 60 minutes in each of X, Y, Z directions Conforms to IEC 60068-2-27, JIS C0041. 147 m/s2 {15G} 3 times in each of X, Y, and Z directions 1 kg max. Front panel: Equivalent to IP65F (NEMA4)* Programmable Terminals Dimensions NT631C/NT631 NT31C/NT31 302.2 183.5 POWER RUN POWER 250 237.2 RUN 142 7.5 315 54 195 mm (vertical x horizontal) Recommended Panel Cutout Dimensions +0.5 131.0+0.5 0 x 184.0 0 mm (vertical x horizontal) Programmable Terminals x 303.0 +0.50 5 54 Recommended Panel Cutout Dimensions 238.0 +0.5 0 130.5 Touch-screen HMI 655 NT21S Small touch-screen HMI L Cost effective touch screen terminals to replace function key units and increase the flexibility and operation. Features Effective display area 117 x 63 mm High-speed NT Links Two RS-232C ports Memory Link Up to 3,999 screens Supports Memory Units Concentrated functionality Mathematical functions 31 functional parts •Recipes •Alarm lists/histories •Image library •Trend graphs •Analog meters NT20S/NT31 data compatibility Upgraded NT Support Tool version (-EV4.6) •Shares I/O comment data with CX-Programmer •Symbol Manager previews •Copy image library window data •Individual editing of grouped parts 656 Supports RS-232C/422 Adapter (connector) Programming Console function Barcode Reader function Programmable Terminals Connectable PLCs for Direct Access Communications method Host link (RS-232C) C200H C200HS CU 1:1 NT Link --- Memory Link (NTH protocol) --- CU/CPU (Note 1) CPU (Note 1) --- C200HX/HG/ HE(-Z) CU/CPU (Note 4) CPU (Note 4) --- C1000H/ C2000H CU CS1/CJ1 CV/CVM1 V1 CQM1H CPM1(A) SRM1 CU/CPU CU/CPU CPU --- --- CPU CPU --- --- --- --- CPU (Note 5) CPU (Note 5) --- Computer/ SBC --- --- CPU CPU (Note 2) CPU (Note 3) --- CPU: Connected to built-in CPU Unit port, CU: Connected to Communications Unit. Note: 1. The built-in port can be used on the following CPU Unit: C200HS-CPU2@/3@. 2. The built-in port can be used on the following CPU Unit: CQM1H-CPU21/4@. 3. The built-in port can be used on the following CPU Unit: CQM1H-CPU4@. 4. Connection is also possible to a Communications Board. Refer to the communications methods for individual models for details. 5. A CPM1-CIF01 RS-232C Adapter must be purchased separately General Specifications Display Capacity Item Power supply voltage Power consumption Noise resistance Vibration resistance Item Fixed displays Fixed character strings Graphics Marks Ambient operating temperature Storage temperature Ambient operating humidity Dimensions Enclosure ratings Weight −20 to 70°C (with no icing) 35% to 85% (with no condensation)(0 to 40°C) 35% to 55% (with no condensation)(40 to 50°C) 190 x 110 x 53.5 mm (W x H x D) (thickness inside panel: 49.0 mm) Front panel operating section: Equivalent to IP65F, NEMA 4.* 0.6 kg max. Number of screens Screen types * Usage may not be possible in places where the unit would be exposed to oil for long periods. Specification A total of 65,535 per With overlapping screens, screen the total is 524,280 per (Graphics: Continuous screen straight lines, rectangles, circles, polygons, arcs, sectors) Numeral displays 256 positions per screen, max. 10-digit disply (2 words) Character string dis- 256 positions per screen max. plays 1,024 display elements for overlapping screens Graph displays 50 positions per screen, capable of displaying signs and percentages Analog meters 50 positions per screen, capable of displaying signs and percentages Trend graphs One frame per screen, 50 items per frame (8 items max. for data logging) Broken line graphs One frame per screen, 256 items per frame, 260 points per item Lamps 256 positions per screen Image library images 256 positions per screen Touch switches 256 positions per screen, max. 256 meshes Numeral settings 256 positions per screen Total of 256 positions for (numerical keypad) both numerical and thumbwheel settings Thumbwheel set26 positions per screen tings Character string set- 256 positions per screen tings Temporary inputs One position per screen Alarm lists/histories Four groups per screen Recipes One position per screen Normal screens Display screens registered as normal Overlapping screens A maximum of eight screens can be displayed overlapping each other Windows Up to three window screens can be displayed Display history Order of occurence (1,024 screens max.), order of frescreens quency (255 times max.) System startup Displayed when powering ON (or resetting) the PT, screen and when switching to RUN mode Programming conEmulates PLC programming Console functions, capasole screen ble of being called from RUN mode. Screen attributes Buzzer, display history, normal background colors, backlight mode, local windows Max. number of reg- 3,999 istered screens Screen number 0: No display 1 to 3999: User registered screens (normal, overlapping, windows) 9000: System startup screen 9001: Display history screens, order of occurence 9002: Display history screens, order of frequency 9020: Programming console screen 9021 to 9023, 9030: Reserved 9999: Return to previous screen designation Screen registration By transferring screen data from the NT Support Tool method to the PT via serial communications By mounting the Memory Unit and downloading (automatic/manual transfer) data to the PT Saving screen data Flash memory (PT internal image memory) Display elements Shock resistance Specification 24 V DC 7 W max Conforms to IEC61000-4-4, Power supply line 2 kV 10 to 57 Hz with 0.075 mm single amplitude, 57 to 150 Hz with 9.8 m/s2 acceleration, for a total of 60 min. in X, Y, and Z directions. Peak acceleration 15 G 3 times each in X, Y, and Z directions 0 to 50°C (with no icing) Small touch-screen HMI 657 Programmable Terminals Specifications Display Specifications NT21 Standard Models Item Display Display device Panel Number of dots (resolution) Effective display area Viewing angle Display color Service life Automatic turnOFF Backlight Service life (white cold cathode tube) Replacement Product Specification Monochrome STN LCD 260 dots horizontally x 140 dots vertically NT21 Pro- Monochrome STN grammable Terminal 117 mm horizontally x 63 mm vertically Left/right direction: 30°, up/down: 30° Black & white (with blue mode) 50,000 hours min. (until contrast reduced to 50%) Can be set to turn OFF in 1 to 255 min or to remain ON with screen saver 50,000 hours min. (at room temperature, until brightness is reduced to 50%) Non-replaceable Specification 91 (13 horizontally x 7 vertically) Pressure-sensitive 1 N max. Frame color: beige Frame color: black Support Tool Windows 95, 98, ME, NT, or 2000 Cables For screen transfer For PLC PT: 9-pin connection PLC: 9-pin Panel Specifications Item Touch Number of panel switches Input Threshold force for operation Life expectancy Specification Options 1 million operations min. CD-ROM Cable length: 2 m Cable length: 5 m PT: 9-pin Cable PLC: 25-pin length: 2 m Cable length: 5 m PT: 9-pin Cable PLC: Mini-peripheral length: 2 m Cable length: 5 m Reflection Protective Display area only (5 Sheets sheets) Chemical-resistive Cover Silicon cover Battery For alarm lists/histories Memory Unit For screen and system data transfer External Interface Specifications Communication method NT support Tool PLC Host Link 1:1 NT Link 1:N NT Links NT Link, PT Programming Console function SBC/personal computer Memory Links Barcode Reader Serial port A Supported Supported Supported Supported Supported Supported Supported Serial port B Not Supported Supported Supported Supported Supported Supported Not Supported RS-232C/422A Adapter Connector Kit Model number NT21ST121E NT21ST121B-E NTZJCAT1EV4 XW2Z-S002 XW2ZS200T XW2ZS500T XW2ZS200S XW2ZS500S XW2ZS200T-2 XW2ZS500T-2 NT20MKBA04 NT20SKBA01 C500BAT08 NT-MF161 NS-AL002 XM2S0911-S003 . Dimensions 178 100 122 53.5 4.5 39 min. 42 max. Rear panel 110 15.5 28 142 190 Panel thickness: 1.6 to 4.8 mm Recommended cut-out size: 178.5 +0.5/Ð0 x 100.5 +0.5/Ð0 mm (W x H) 658 19.5 52.5 Programmable Terminals NT11S Function-key HMI terminal The NT11S, the Slim, Low Cost Operation Terminal that Stands Up Well to Harsh Environments. • • • • Long-lived Backight Simplified Ladder Programming Password Screens Conforms to NEMA4 and IP65 Withstands Water and Oil • Use in many demanding ares even with oil and water The front panel of the terminal withstands water to NEMA4 and IP65 standards, which means that it can be used even in locations where it may be splashed with water or oil. Large Keys • For easy operation by all users The numeric keys and function keys have been made a generous size for your convenience. They can be operated even when wearing working gloves. Entry of Numerical Values The numeric key pad integrated with the display allows the entry of numerical values such as temperatures and production quantities. Printout of Production Status Data such as the production status and production results can be printed out, leaving a record on paper which can be used as a daily report. (The NT11S has a printer port. One screen only is printed.) “Direct Connection” Communication • Simplifies Ladder Programming The NT11S supports two communication methods: the NT link method, which substantially reduces the size of the program at the host side, and the host link direct connection method. The “NT link” method features a particularly high response speed. • NT link method SYSMAC C200HS–CPU3@/2@ CQM1–CPU4@ • Host link direct connection method SYSMAC C200HS–CPU3@/2@ C200H–LK201/–V1 CQM1 (Excludes –CPU11) Function-key HMI terminal Integral Numeric Key Pad The display, numeric keys, and function keys are all integrated into the front panel, which is convenient for designers. The key layout is ergonomically designed for ease of use. Password Screens for Security • To limit access to authorized persons only Password screens cannot be accessed unless the correct password is entered. This means that the operations that can be performed can be restricted according to the operator. Key Titles can be Marked on the Function Key Sheet Key titles can be marked on the function key sheet in accordance with the applications of the keys: the sheet can be taken out from the side face of the terminal. The front panel of the terminal has a water–withstanding construction. Bar Graphs can be Displayed Bar graph displays allow the progress of processes to be checked at a glance. (The bars are oriented horizontally.) Display History Record Helps in Analysis of Machine Faults When the display history record function is set as a screen attribute, the time, the screen number, and a comment are recorded in the terminal’s memory every time the relevant screen is displayed. This display history can be printed by issuing a print instruction from the host, and is useful for machine fault analysis. Screen Operations are Easy Using the support software, screens to be displayed by the terminal can be created as easily as if using a word proces-sing program. This software can be run on an IBM PC/AT or compatible. It contains the system program transfer tool that downloads the system program to the flash ROM. Main functions • Fixed displays, numeral display, character display • Character inversion, flashing, double–width. Character copy, move, delete. • 8 x 16 dot mark registration (max. 64 marks can be registered) • Horizontal bar graphs • Numeral setting • Password 659 Programmable Terminals Main features Easy to Order The front panel is available in beige or black Since the communication interface, image memory, and flash ROM that downloads the system program are incorporated in the NT11S body, placing orders is a simple matter. Long–lived Backlight Since LEDs are used for the backlight, it is very long–lived and rarely needs to be changed. Specifications General Specifications Power supply voltage Allowable power supply voltage range Power consumption Noise resistance Vibration resistance Shock resistance Ambient operating temperature Ambient operating humidity Operating environment Storage temperature Enclosure ratings Weight 24 V DC 20.4 to 26.4 V DC (24 V DC –15 %, +10 %) 15 W max. Common mode (between power supply and panel): 1000 Vp–p Normal mode: 300 Vp–p Pulse width: 100 ns to 1 ms Pulse rise time: 1 ns 10 to 22 Hz with 1.5 mm double amplitude in X, Y, and Z directions. 22 to 500 Hz with 1.5 G {14.7 m/s 2 } acceleration for a total of 30min. in X, Y, and Z directions. 20 G {196 m/s 2 } 3 times each in X, Y, and Z directions. 0 to +50 _C 35 to 85 % RH (with no condensation) No corrosive gases. –20 to +70 _C (with no freezing) Front panel: Equivalent to IP65, NEMA4 1.0 kg max. Display/Panel Specifications Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice. Display screen Dot matrix of STN liquid crystal display panel - Number of dots: 160x64 - Effective display area: 100 40 mm - Life expectancy: 50,000 hours minimum - View angle (left/right direction): ±20° Backlight - LED - Life expectancy: 10,000 hours minimum (average: 30,000 hours) - Automatic turn–off: can be set to turn off in 10 minutes or 1 hour, or to remain on. - POWER indicator (Green LED): Lit while power is being supplied. - RUN indicator (Green LED): Lit during operation - 22 switches - Life expectancy: 1 million operations minimum Indicators Switch Display Capacity Note: Note: In order to improve the performance of displays, liquid crystal devices may be changed without notice. Display characters Number of characters Enlargement function Display elements Screen attributes Character string displays Numeral displays Graph displays Numeral settings Display history Password screen Menu screen Screen types Max. number of registered screens Screen registration method Screen saving method Normal characters (8 16 dots): Alphanumerics and symbols Marks (8 16 dots): User–defined, 64 max. displayed Normal–size: 20 horizontally 4 lines vertically max. Double width 8 positions per screen 8 positions per screen 4 positions per screen 8 positions per screen Order of frequency, 256 screens Ensures security: screens for which this attribute is set can only be displayed if the correct password is input. Four items per screen Normal screen: Displays screen registered as normal. 250 Transfer screen data created using an IBM PC/AT personal computer to the PT. Saved to flash memory: 32KB (downloading method) Special Features Printing function Printing of display history data Printing of daily reports (printing format registered by the users) Self–test for memory, switches, etc. Status setting confirmation for communications and other conditions. Simple communications confirmation Maintenance functions . Ordering Information Product Programmable Terminal Support Software 660 Specification Host link direct connection, Ten–key type (frame color: beige) NT link method Ten–key type (frame color: black) 3.5” FD (for IBM PC/AT) Model NT11S–SF121 NT11S–SF121B NT11S–ZA3AT–EV1 Programmable Terminals Dimensions 203 113 98 7.5 218 38.2 45.3 63.7 22.8 86.2 34.2 Programmable Terminals 51 76 71 Function-key HMI terminal 661 NT2S Small Function Key Terminals The NT2S series Terminals are designed as a human machine interface for simple control tasks. Their small dimensions and low installation depths ensure that they will fit into any machine. Of the six NT2S types, four can be connected directly to the peripheral port and two can be connected to OMRON PLCs via an RS-232C port. • • • • • • Easy programming Small size and installation depth IP65 protection Real-time clock Printer connection Excellent value for money Performance Data (Max. Values) Max. screen pages NT2S-SF121B-EV2 Yes 109x60x36 mm 56x11 mm 5x7 pixel/character 2/16 6 24 kB for applications 250 NT2S-SF125B-E Yes 107x107x36 56x11 mm 5x7 pixel/character 2/16 20 24 kB for applications 250 NT2S-SF122B-EV2 Yes 109x60x36 mm 56x11 mm 5x7 pixel/character 2/16 6 24 kB for applications 250 NT2S-SF126B-E Yes 107x107x36 56x11 mm 5x7 pixel/character 2/16 20 24 kB for applications 250 Number input Bar graph Trend/line diagram Alarm handling Real-time clock/date Printer interface Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes Yes (RS-232C) - Yes (RS-232C) - Yes (peripheral port) - Programmable Terminal size (W,H,D) Display size Number of screen pixels Number of lines/characters Number of function/control keys Memory NT2S-SF123B-EV2 No (PLC controlled) 109x60x36 mm 56x11 mm 5x7 pixel/character 2/16 6 PLC memory is used NT2S-SF127B-E No (PLC controlled) 107x107x36 56x11 mm 5x7 pixel/character 2/16 20 PLC memory is used Yes Yes Yes Depending on PLC memory Yes Yes - Depending on PLC memory Yes Yes - Yes (peripheral port) - Yes (peripheral port) - Yes (peripheral port) - Communication Host Link 1:1 NT Link 1:n NT Link ASCII protocol 662 Programmable Terminals System Configuration Host Link Data is exchanged quickly between the Control Terminal and an OMRON PLC using the Host Link protocol. The RS-232C communication method can be used. The following OMRON PLC systems feature the Host Link protocol: - CPM1 family - CPM2 family - CQM1 family - CJ1 - CS1 Miniature Peripheral port NT2S-SF121B NT2S-CN223-V1 for CS1,CJ1, CQM1H CS1 RS232C port CJ1 RS-232C cable for CPM1A, CPM2C (CIF adapter required) NT2S-SF125B Peripheral port CQM1H NT2S-CN212/215 for CPM1A, CPM2A CPM2C Programmable Terminals CPM2A CPM1A Power supply: 24 VDC, external Miniature peripheral port NT2S-SF122B NT2S-SF123B NT2S-CN224-V1 CS1 CJ1 NT2S-SF126B NT2S-SF127B CQM1H CPM2C Peripheral port NT2S-CN222-V1 NT2S-CN225-V1 CPM2A CPM1A Power supply: from the PLC, via port connection Small Function Key Terminals 663 Product Overview Model code Display size (WxHxD) Number of screen pixels Number of lines/characters Number of function/control keys Memory Supply voltage Degree of protection NT2S-SF121B-EV2 NT2S-SF125B-E - Programmable using software - Real-time clock - Printer port - PLC connection via RS-232C port - Supply voltage 24 V 108x60x43 mm 108x108x43 mm 5x7 pixel/character 2/16 2/16 6 20 24 kB Flash memory for applications 24 V DC 24 V DC IP65F (front side) NT2S-SF122B-EV2 NT2S-SF126B-E - Programmable using software - Printer port - PLC connection via peripheral port - Supply voltage connection via peripheral port 108x60x43 mm 108x108x43 mm NT2S-SF121B-EV2 NT2S-SF125B-E NT2S-SF122B-EV2 NT2S-SF126B-E 2/16 6 2/16 20 NT2S-SF123B-EV2 NT2S-SF127B-E - Functions are controlled using the PLC - PLC connection via peripheral port - Supply voltage connection via peripheral port 108x60x43 mm 108x108x43 mm 2/16 2/16 6 20 PLC memory is used --- Specifications Model code Function keys Key type Key function Display elements Characters Image colours Character display attributes Display specification Display Function displays Display capacity String display Numeric display Bar graph display Character string input Alarm list Time display Screen page Number of stored screen pages Screen page numbers Storing of screen pages General Battery backup Supply voltage Power consumption Immunity NT2S-SF123B-EV2 NT2S-SF127B-E Membrane keyboard As well as fixed or system functions, functions can be assigned dynamically using software (Softkeys), while global, i.e. screenindependent, keys can also be defined 5x7 pixel/character Monochrome Normal, flashing (entire screen) - LED backlit LCD Module, 2x16 characters, 5x7 pixel/character - Character size 4.35 mm - Extended ASCII character set (semi-graphic) 2 status LEDs1, programmable via PLC Entire display area can be used Entire display area can be used Entire display area can be used Either by output from Controller real-time From Controller clock or output from Terminal's integrated real-time clock Max. 250 1..250 Transfer of data from a PC to the Terminal All programming in the PLC Data backup in EEPROM 10..30 V DC via PLC approx. 1.5 W Between power supply and panel: 1700 Vss Normal: 480 Vss Pilse width 100 ns..1 µs Pulse rise time 1 ns 10..61.2 Hz with 0.1 mm amplitude 61.2..150 Hz with an acceleration of 1.5 g in X, Y and Z directions 4 times for 8 minutes each 147 m/s², 3x in X, Y and Z directions 0 °C..50 °C 35%..85% No corrosive gases -20 °C..60 °C Front side: IP65F, Rear side: IP20 CE, c-UL 150 g 230 g 135 g 205 g 130 g Vibration resistance (in operation) Shock resistance (in operation) Ambient temperature Ambient humidity Operating environment Storage temperature Degree of protection Approvals Weight Host Link Direct communication Communication method RS-232C or Peripheral port Peripheral port Communication protocol C series SYSWAY (1:1) Communication settings Start/stop synchronisation Communication speed: 9600 bps Data length: 7 bits Stop bit: 2 bits Parity: even Connection 1 x 9-pin D-Sub female for PLC 1 x 9-pin D-Sub male for PLC 1 x 9-pin D-Sub female for PC/Printer, 1 x 9-pin D-Sub female for PC/Printer SW download/printer Number of devices 1 Printer Communication method ASCII protocol printer Connection Serial RS-232C port 200 g 1x9-pin D-sub male for PLC No No 1. The NT2S-SF125/126/127B-E do not have status LEDs 664 Programmable Terminals Programming and Accessories Programming Accessories, cables etc. Description NT Shell. Programming software for Control Terminals. For WINDOWS 95/98/ME/2000/NT4.0-SP5 see page 454 Connecting cable, NT2S SF121B / SF125B PLC (peripheral port) Cable length - Model code NT Shell 2m 5m Connecting cable, 2m NT2S SF122B / SF123B / SF126B / SF127B PLC (peripher- 5 m al port) Connecting cable, 2m NT2S-SF121B / SF125B PLC (miniature peripheral port) Connecting cable, 2m NT2S-SF122 / SF123B / SF126B / SF127B PLC (miniature peripheral port) Adapter cable, 2m miniature peripheral port PLC (peripheral port) NT2S-CN212 NT2S-CN215 NT2S-CN222-V1 NT2S-CN225-V1 NT2S-CN223-V1 NT2S-CN224-V1 CS1W-CN114 Dimensions (mm) NT2S-SF121B-EV2 NT2S-SF122B-EV2 NT2S-SF123B-EV2 60 Programmable Terminals 43 27 109 92 NT2S-SF125B-E NT2S-SF126B-E NT2S-SF127B-E 107 107 93 27 92 Small Function Key Terminals 665 NT-AL001 RS-232C/RS-422A Adapter The NT-AL001 converts signals between RS-232C and RS-422A. Use the NT-AL001 to connect 1:N NT Link communications, to connect to multivendor communications, or anytime signal conversion is required. Specifications General Specifications RS-232C Interface Item Model number Ambient operating temperature Ambient operating humidity Rated power supply voltage Rated power supply current Surge current Insulation resistance Item Baud rate Transmission distance Connector Specification NT-AL001 0 to 55°C 10% to 90% (with no condensation) +5 V ±10% (supplied from pin 6 of RS-232C connector) 150 mA max. 0.8 mA max. 20 MΩ min. (at 500 V DC) between RS-422A signal lines and functional ground terminal Dielectric strength 1,500 V AC between RS-422A signal lines and functional ground terminal for 1 min, leakage current: 10 mA max. Operating environment No corrosive gases Ambient storage temper- −20 to 75°C ature Vibration resistance Conforms to JISC 0911, 80 min each in X, Y, and Z directions Shock resistance Conforms to JISC 0912, 15G for 3 times each in X, Y, and Z directions Weight 200 g 666 Specification 64 kbps max. 2 m max. D-Sub, 9-pin connector (female) RS-422A Interface Item Baud rate Transmission distance Terminals Specification 64 kbps max. (depends on RS-232C baud rate) 500 m max. 8-terminal removable terminal block, M3.0 terminals Programmable Terminals Dimensions RS-422A terminals 53.5 110 RS-232C connector OMRON NT-AL001 4 74.5 100.2 105 max. (30) 45 30 (Unit: mm) 30 x 114 x 100.2 mm (W x H x D) with RS-422A terminal cover removed. Programmable Terminals 30 x 114 x 119.5 mm (W x H x D) with RS-422A terminal cover in place. RS-232C/RS-422A Adapter 667 Ordering Information PTs NS Series Name NS12 Specifications TFT, 12”, 800 x 600 dots Without Ethernet With Ethernet NS10 TFT, 10”, 640 x 480 dots Without Ethernet With Ethernet NS8 TFT, 8”, 640 x 480 dots Without Ethernet With Ethernet NS5 STN, 5.7“, 320 x 240 dots Without Ethernet With Ethernet Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Model NS12-TS00 NS12-TS00B NS12-TS01 NS12-TS01B NS10-TV00 NS10-TV00B NS10-TV01 NS10-TV01B NS8-TV00 NS8-TV00B NS8-TV01 NS8-TV01B NS5-SV00 NS5-SV00B NS5-SV01 NS5-SV01B NT Series Name NT631 Specifications TFT color NT21S STN monochrome NT11 STN monochrome Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Frame color: Beige Frame color: Black Ten–key type NT2S LCD monochrome Programmable EL NT31 STN color STN monochrome PLC controlled Programmable Frame color: Beige Frame color: Black 6-key type, Frame color: Black 20-key type, Frame color: Black PLC controlled Model NT631C-ST151 NT631C-ST151B NT631-ST211 NT631-ST211B NT31C-ST141 NT31C-ST141B NT31-ST121 NT31-ST121B NT21-ST121E NT21-ST121B NT11S–SF121 NT11S–SF121B NT2S-SF121B NT2S-SF122B NT2S-SF123B NT2S-SF125B NT2S-SF126B NT2S-SF127B Support Software NS-series PTs Name NS-series Screen Design Software for Windows Cable to transfer screens Specifications For NS-series PTs Windows 95, 98, Me, 2000, XP, or NT 4.0 IBM PC/AT or compatible Model NS-NSDC1 Specifications For NT-series PTs Windows 95, 98, Me, 2000 or NT 4.0 For NT31, NT31C, NT631, or NT631C To print hardcopies of screens Model NT-Shell XW2Z-S00S NT-series PTs Name NT-series Support Software for Windows Memory Unit to transfer screens Printer cable for NT Series 668 NT-MF261 NT-CNT121 Programmable Terminals Options Specifications 1 CD-ROM For NS Series Ladder Monitor applications (See note 1.) and I/O Comment File Creation Tool (See note 2.) RS-232C/RS-422A Adapter Reflective Protective Sheets (front only, 5 sheets in a set) Protective Covers (5 covers in a set) Memory Cards 8 MB 15 MB 30 MB 48 MB Memory Card Adapter Battery A Memory Card must be purchased separately to operation on the NS-series PT. A HMC-AP001 Memory Card Adapter is required to write data from the CD-ROM to a Memory Card on a personal computer. For NS Series For NS10/NS12 For NS7 For NS10/NS12 For NS7 For NS Series For NS Series For NS10/NS12 For NS7 For NT631/NT31 For NT631C/NT631 For NT31C/NT31 For NT20S For NT631C/NT631 For NT31C/NT31 For NT631C/NT631 For NT31C/NT31 For NT631C-ST151(B)-EV2 For NT631C-ST141(B)-EV2 For NT31C/NT31 For NT20S Refer to the Barcode Reader catalog for details. For CV-series, C200HS, C1000H, and C500 PLCs DeviceNet Interface Unit Reflective Protective Sheets (front only, 5 sheets in a set) Protective Covers (5 covers in a set) Chemically Resistive Covers (5 covers in a set) Replacement Backlights Barcode Reader RS-232C/RS-422A Adapter Model NS-EXT01 NS-EXT01-L03 (3 licenses) NS-EXT01-L10 (10 licenses) NS-EXT01-HMC (with 48-MB Memory Card) NS-AL002 NS12-KBA04 NS7-KBA04 NS12-KBA05 NS7-KBA05 HMC-EF861 HMC-EF171 HMC-EF371 HMC-EF571 HMC-AP001 C500-BAT08 CPM2A-BAT01 NT-DRT21 NT610C-KBA04 NT30-KBA04 NT20M-KBA04 NT631C-KBA05 NT31C-KBA05 NT625-KBA01 NT30-KBA01 NT631C-CFL01 NT631C-CFL02 NT31C-CFL01 NT20S-CFL01 V520-RH21-6 NT-AL001 Programmable Terminals Name Ladder Monitor Software Note: 1. This application for the NS-series PT enables monitoring ladder programs in SYSMAC CS/CJ-series PLCs on the PT. 2. This software extracts I/O comment data from CXT files from the CX-Programmer and converts them for ladder monitoring. PT-PLC Connecting Cables Communications method Cable Host Link, 1:1 NT Link (D-Sub, Host Link Cable 9-pin; D-Sub, 25-pin; or peripheral) SYSMAC PLC connector D-Sub, 9-pin PT connector D-Sub, 9-pin D-Sub, 25-pin D-Sub, 25-pin D-Sub, 9-pin CS1, CJ1, or CQM1H periph- D-Sub, 9-pin eral port Cable length 2m 5m 2m 5m 2m 5m 2m 5m 70 cm 2m 2m 5m Model XW2Z-200T XW2Z-500T XW2Z-200S XW2Z-500S XW2Z-200P XW2Z-500P XW2Z-200T-2 XW2Z-500T-2 XW2Z-070T-1 XW2Z-200T-1 NT2S-CN212 NT2S-CN215 1:N NT Link for connection of multiple PTs NT-A001-to-PT Cable D-Sub, 9-pin (on NT-AL001) D-Sub, 9-pin NT2S-SF121 and 125 to CPM1A, CPM2A PLC peripheral port NT2S-SF122, 123, 126 and 127 to CPM1A, CPM2A PLC peripheral port. NT2S-SF121 and 125 to CJ1, CS1, CQM1H, PLC peripheral port. NT2S-SF122, 123, 126 and 127 to CJ1, CS1, CQM1H, PLC peripheral port. Adapter Host link to NT2 connecting cables peripheral port NT2S SF121B / SF125B Host link to NT2 connecting cables peripheral port NT2S SF122B / SF123B / SF126B / SF127B 2m 5m NT2S-CN222-V1 NT2S-CN225-V1 Connecting cable miniature peripheral port NT2S-SF121B / SF125B 2m NT2S-CN223-V1 Host link to NT2 connecting cables miniature peripheral port NT2S-SF122 / SF123B / SF126B / SF127B 2m NT2S-CN224-V1 Adapter cable peripheral port miniature peripheral port 2m CS1W-CN114 Note: Refer to the product manuals for cables other than those listed above. 669 ALL DIMENSIONS SHOWN ARE IN MILLIMETERS. To convert millimeters into inches, multiply by 0.03937. To convert grams into ounces, multiply by 0.03527. Cat. No. V02E-EN-01 In the interest of product improvement, specifications are subject to change without notice.
NT31C-CN522-EU 价格&库存

很抱歉,暂时无法提供与“NT31C-CN522-EU”相匹配的价格&库存,您可以联系我们找货

免费人工找货