0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
24H1301-2R

24H1301-2R

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    24H1301-2R - 50 Watt DC-DC Converters - Power-One

  • 数据手册
  • 价格&库存
24H1301-2R 数据手册
H Series 50 Watt DC-DC Converters Wide input voltage ranges up to 60 V DC 1, 2 or 3 outputs up to 48 V DC 4 kA DC I/O electric strengh test voltage LGA • Rugged electrical and mechanical design • Output 1 regulated, outputs 2 and 3 tracking • Operating ambient temperature range –25...71 °C with convection cooling Selection chart Output 1 Uo nom Io nom [V DC] [A] 5.1 8 5.1 8 5.1 8 12 4 12 4 12 4 15 3.4 15 3.4 15 3.4 24 2 24 2 24 2 48 1 48 1 48 1 12 2 12 2 12 2 15 1.7 15 1.7 15 1.7 5.1 5 5.1 5 5.1 5 5.1 5 5.1 5 5.1 5 Output 2 Uo nom Io nom [V DC] [A] 12 2 12 2 12 2 15 1.7 15 1.7 15 1.7 12 0.7 12 0.7 12 0.7 15 0.6 15 0.6 15 0.6 Output 3 Uo nom Io nom [V DC] [A] 12 0.7 12 0.7 12 0.7 15 0.6 15 0.6 15 0.6 Input voltage Ui [V DC] 8...15 14...30 28...60 8...15 14...30 28...60 8...15 14...30 28...60 8...15 14...30 28...60 9...15 18...30 36...60 8...15 14...30 28...60 8...15 14...30 28...60 8...15 14...30 28...60 8...15 14...30 28...60 Type Options 12 H1001-2R 24 H1001-2R 48 H1001-2R 12 H1301-2R 24 H1301-2R 48 H1301-2R 12 H1501-2R 24 H1501-2R 48 H1501-2R 12 H1601-2R 24 H1601-2R 48 H1601-2R 12 H1901-2R 24 H1901-2R 48 H1901-2R 12 H2320-2 24 H2320-2 48 H2320-2 12 H2540-2 24 H2540-2 48 H2540-2 12 H3020-2 24 H3020-2 48 H3020-2 12 H3040-2 24 H3040-2 48 H3040-2 -7, D, V -7, D, V -7, D, V -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D -7, D, V -7, D, V -7, D, V -7, D, V -7, D, V -7, D, V 2/12.2000 www.power-one.com 1 Cassette Style Input Input voltage refer to selection chart H Series Output Efficiency Output voltage 1 setting acc. Output voltage 2, 3 setting acc. Output voltage switching noise Line regulation Load regulation output 1 Load regulation output 2, 3 Output voltage 2, 3 Cross load regulation outp. 2, 3 Minimum output current Current limitation main output Current limitation aux. output(s) Operation in parallel Hold-up time Ui nom, Io nom Ui nom, Io nom Ui nom, Io nom IEC/EN 61204, total Ui min....Ui max, Io nom Ui nom, 0...Io1 nom 10...100% Io2,3 nom Ui nom, Io1 nom, Io2,3 = 0 0...100% Io1 nom not required rectangular U/I characteristic rectangular U/I characteristic by current limitation Ui nom, Io nom, with ext. diode in input line up to 86% ±2% Uo1 nom ±7.5% Uo2,3 nom typ. 200 mVpp typ. ±1% Uo nom typ. 0.2% Uo1 nom typ. 0.7 V max. 115% Uo2,3 nom typ. 0.7 V 0A typ. 110% Io nom typ. 120% Io nom up to 1 ms Protection Input reverse polarity Input undervoltage lockout Input overvoltage lockout Input transient protection Output Output overvoltage Overtemperature with external fuse typ 80% Ui min typ 110% Ui max suppressor diode no-load, overload g2d short circuit proof suppressor diode in each output switch-off with auto restart typ 150% Uo nom TC typ 100 °C Control Output voltage adjustment Inhibit Status indication single output models 0...110% Uo1 nom TTL input, output(s) disabled if left open-circuit LEDs: OK, inhibit Safety Approvals Class of equipment Protection degree Electric strength test voltage EN 60950, UL 1950, CSA C22.2 No. 950 units without options I/case I/O O/case O/O class I IP 40 2 kV AC 4 kV AC 1 kV AC 0.2 kV AC 2/12.2000 www.power-one.com 2 H Series EMC Electrostatic discharge Electromagnetic field Electr. fast transients/bursts Surge Electromagnetic emissions 50 Watt DC-DC Converters IEC/EN 61000-4-2, contact discharge, level 2 (4 kV) criterion A IEC/EN 61000-4-3, level x (20 V/m) criterion A IEC/EN 61000-4-4, input, level 1 (0.5 kV) criterion A IEC/EN 61000-4-5, input, level 1 (0.5 kV) criterion A CISPR 22/EN 55022, 12H, conducted class A CISPR 22/EN 55022, 12H, radiated class B CISPR 22/EN 55022, 24H, 48H, radiated and conducted class B Environmental Operating ambient temperature Operating case temperature TC Storage temperature Damp heat Vibration, sinusoidal Shock Bump MTBF Ui nom, Io nom, convection cooled Ui nom, Io nom non operational IEC/EN 60068-2-3, 93%, 40 °C IEC/EN 60068-2-6, 10...60/60...150 Hz IEC/EN 60068-2-27, 11 ms IEC/EN 60068-2-29, 16 ms MIL-HDBK-217E, GB, 40 °C, single output types –10...50 °C –10...80 °C –25...100 °C 21 days 0.15 mm/2 gn 15 gn 10 gn 384'000 h Options Extended temperature range –25...71 °C, ambient, operating Input and/or output undervoltage monitoring, excludes option V Input and/or output undervoltage monitoring (VME), excludes option D -7 D1…D8 V2, V3 Accessories Front panels 19" (Schroff/Intermas) Mating H11 connectors with screw, solder, fast-on or press-fit terminals Connector retention facilities and code key system for connector coding Flexible PCB for connecting the converter via an H11 connector, if mounted on a PCB Chassis or wall mounting plates for frontal access Universal mounting brackets for chassis or DIN-rail mounting Pin allocation Pin 2 5 8 11 14 17 14 17 20 23 26 29 32 Electrical Determination Inhibit control input Save Data or ACFAIL Output voltage (positive) Output voltage (negative) Control input + Control input – Output voltage (positive) Output voltage (negative) Output voltage (positive) Output voltage (negative) Protective earthing DC input voltage DC input voltage H1000 i D or V Vo1+ Vo1– R G H2000 i D or V H3000 i D or V Vo3+ Vo3– Vo1+ Vo1– Vi+ Vi– Vo2+ Vo2– Vo1+ Vo1– Vi+ Vi– Vo2+ Vo2– Vo1+ Vo1– Vi+ Vi– 2/12.2000 www.power-one.com 3 Cassette Style Mechanical data Tolerances ±0.3 mm (0.012") unless otherwise indicated. 2 5 8 11 14 17 20 23 26 29 32 S09050 H Series European Projection 20 (0.79") 2TE 6TE M 3; depth = 4 mm (chassis mount) 168.5 (6.63") 173.7 (6.84") 127 (5") 22 (0.87") Measuring point for case temperature TC 68 103 111.2 (3U) (4.38") 38.7 (1.52") OK Inhibit i Potentiometer (option D or V) 2/12.2000 www.power-one.com 4
24H1301-2R 价格&库存

很抱歉,暂时无法提供与“24H1301-2R”相匹配的价格&库存,您可以联系我们找货

免费人工找货