0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BLP30-1024G

BLP30-1024G

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    BLP30-1024G - 30 Watts - Power-One

  • 数据手册
  • 价格&库存
BLP30-1024G 数据手册
BLP30 AC-DC Series Data Sheet 30 Watts Features • • • • • • • • • • • • RoHS compliant for all six substances 2” x 4” footprint Component height less than 1” 25 W rating with natural convection cooling 30 W rating with 10 CFM airflow Compliance to EMI Class B Universal AC input Short-circuit protection Overvoltage protection CE marked to Low Voltage Directive (Pending) Compliance to EN61000-4-2/-3/-4/-5/-6/-8/-11 Two-year warranty Applications • • • • • • • Datacom (hubs, routers) POS terminals Industrial Cable modems External disk storage Medical instrumentation Computers Description The BLP30 Series’ economical and compact construction provides single or three-output AC to DC power conversion to meet the requirements of most commercial and industrial applications. Single-Output Model Selection Model Nominal Output Voltage (VDC) 5V 12V 24V Min-Max Output Current (Amps), Convection 0–5 0 – 2.1 0 – 1.0 Min-Max Output Current (Amps), 1 Forced Air 0–6 0 – 2.5 0 – 1.25 Peak Output Current (Amps) 2 7.2 3.0 1.5 Total Regulation 3 (%) ±2 ±2 ±2 Ripple & Noise 4 pk-pk % 1 1 0.6 BLP30-1005G BLP30-1012G BLP30-1024G Triple-Output Model Selection Model Nominal Output Voltage (VDC) +5V BLP30-3000G +12V -12V 1 Min-Max Output Current (Amps), Convection 0.2 – 2.5 0.1 – 1.2 0.0 – 0.3 Min-Max Output Current (Amps), Forced Air 1 0.2 – 3.5 0.1 – 2.0 0.0 – 0.5 Peak Output Current (Amps) 2 5 3 1 Total Regulation (%) 3 ±2 ±5 ±5 Ripple & Noise 4 pk-pk % 1% 1% 1% 2 3 4 10 CFM or 260 LFM (average measurement of six equally-distributed points through a 3.5" x 1.6" (9 cm x 4 cm) cross-sectional area with power supply mounted on a 0.25" (6.35 mm) standoffs. Recommended airflow direction is from the AC input to the DC output. Peak current duration for less than 30 seconds with a max duty cycle of 10%. At 25 °C ambient including voltage set point tolerance, line, and load regulation Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, measured with a twisted pair differentially across a 10 µF E-cap and a 0.1 µF ceramic cap in parallel. The point of measurement is within 1 cm of the output connection. JUL 05, 2006 revised to DEC 05, 2006 Page 1 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts ELECTRICAL SPECIFICATIONS Input Specifications Parameter Input Voltage - AC Input Voltage - DC Input Frequency Input Current Inrush Surge Current Input fuse Efficiency Switching Frequency AC Input At 90 VAC input., 30W Internally limited. 115 VAC, Max Power, 25 °C Internally limited. 230 VAC, Max Power, 25 °C Non-user serviceable internally located AC input line fuse is provided. At maximum output power. 70 60 75 69 % kHz Conditions/Description Single-phase continuous input range Min. 90 127 47 Nom. 100 - 250 160/325 50 - 60 0.75 16 32 Max. 264 375 63 Units VAC VDC Hz A rms A pk A pk Output Specifications Parameter Output power Load transient Turn on Delay Rise Time Hold-up Time Overvoltage Protection Conditions/Description With convection cooling. See Model Selection. With forced-air cooling. See Model Selection. Vo1, Vo2, or Vo3 deviation due to a 50 to 100% load change at a rate of 1A/µs. Time required for outputs to be within regulation after initial application of AC input. Time required for output voltage to rise from 10% to 90%. At 30W, 115 VAC, 60 Hz. Main output. 5V: 12V: 24V: 20 5.6 14.0 29.0 6.9 16.7 34.2 Min. Nom. Max. 25 30 ±5 1.5 20 Units Watts % Sec ms Ms V Short-circuit Protection Overshoot Overshoot Fully-protected against output short circuit. Single-output models. Triple-output models. 2 5 % % JUL 05, 2006 revised to DEC 05, 2006 Page 2 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Regulatory & Safety Approvals Parameter UL60950-1 CSA-C22.2, No. 60950-1-03 EN 60950-1 /IEC 60950-1 CE Mark for LVD CB Approval Ground Continuity Dielectric Withstand Voltage Conditions/Description All models are approved. All models are approved. All models are approved. All models are approved. Completed. At 12 VDC. Input-to-Ground (Basic) . Input-to-Output (Reinforced). The primary to secondary test is not performed on completed assemblies. Output-to-Ground (Functional). FCC Part 15. CISPR 22 and CISPR 11. Per EN 61000-4-2, level 2. Per EN 61000-4-3, level 3. Per EN 61000-4-4, level 3. Per EN 61000-4-5, class 3. Per EN 61000-4-6, level 3. Per EN 61000-4-8. Per EN 61000-4-11 Per EN 60950 At 115 VAC: At 230 VAC: 0.2 0.4 mA Line-to-Line: Line-to-Ground: 1 1 2 3 1 3 V/m kV kV V/m A/m Conducted: Conducted: 2121 4242 30 A VDC VDC Min. Nom. Max. Units 500 B B VDC Class Electromagnetic Interference ESD Radiated Susceptibility EFT/Burst Input Transient Protection RF Immunity Magnetic Fields Voltage Interruptions Leakage Current JUL 05, 2006 revised to DEC 05, 2006 Page 3 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Environmental Specifications Parameter Altitude Operating Temp Conditions/Description Operating. Non-Operating. 0 ºC to 70 ºC with linear derating to 50% above 50 ºC. Unit will start-up at -20 ºC, but will not meet all published specifications. 0 50 Min. Nom. Max. 10K 50K 70 Units ASL ft ASL ft ºC Storage Temp Temperature Coefficient Relative Humidity Shock 0 ºC to 70 ºC (after 15-minute warm-up). 95% relative humidity @ 40 ºC, non-condensing Operating: half-sine, 11 ±3 ms, 3-axis. Non-Operating: half-sine, 11 ±3 ms, 3-axis. Vibration Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). Non-Operating: Random vibration; 5 to 500 Hz (10 minutes, each axis). -40 ±0.02 85 ºC %/ ºC 95 15 40 2.4 %RH G G Grms 6 Grms JUL 05, 2006 revised to DEC 05, 2006 Page 4 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Mechanical Drawing – Single Output Models All dimensions are in inches. CN1 - AC CONN. Pin 1 Pin 3 Pin 5 Ø 0.16 (4 places) AC Neutral AC Line AC Ground 4.00 +/- 02 3.750 CN2 - DC CON Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 VOUT DC COM VOUT DC COM VOUT TOP VIEW CN1 input connector Pin #1 CN2 - DC output connector (see pin-out table) 2.07 +/-.02 1.750 Pin #1 PCB AC Ground Connection Point - Solder side fastener clearance area 0.25 DIA (4 places) 0.06 1.07 +/-.02 SIDE VIEW 0.91 END VIEW Printed Circuit Board 0.1 RECOMMENDED MATING CONNECTORS HOUSING CN1 and CN2 MOLEX 22-01-2051 MOLEX 22-01-2057 MOLEX 22-01-3057 LEOCO 2530S05000 * PIN * MOLEX 08-52-0123 MOLEX 08-52-0101 LEOCO 2533TPB0000 Equivalent housings and pins can also be used. JUL 05, 2006 revised to DEC 05, 2006 Page 5 of 6 www.power-one.com BLP30 AC-DC Series Data Sheet 30 Watts Mechanical Drawing – Triple Output Model All dimensions are in inches. CN1 - AC CONN. Pin 1 Pin 3 Pin 5 Ø 0.16 (4 places) AC Neutral AC Line AC Ground 4.00 +/- 02 3.750 CN2 - DC CON Pin 1 Pin 2 Pin 3 Pin 4 Pin 5 Vo3 DC Com Vo1 DC COM Vo2 TOP VIEW CN1 input connector Pin #1 CN2 - DC output connector (see pin-out table) 2.00 +/-.02 1.750 Pin #1 PCB AC Ground Connection Point - Solder side fastener clearance area 0.25 DIA (4 places) 0.06 1.07 +/-.02 SIDE VIEW 0.91 END VIEW Printed Circuit Board 0.1 * RECOMMENDED MATING CONNECTORS HOUSING CN1 and CN2 MOLEX 22-01-2051 MOLEX 22-01-2057 MOLEX 22-01-3057 LEOCO 2530S05000 * PIN MOLEX 08-52-0123 MOLEX 08-52-0101 LEOCO 2533TPB0000 Equivalent housings and pins can also be used. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. JUL 05, 2006 revised to DEC 05, 2006 Page 6 of 6 www.power-one.com
BLP30-1024G 价格&库存

很抱歉,暂时无法提供与“BLP30-1024G”相匹配的价格&库存,您可以联系我们找货

免费人工找货