0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
BLP40-1024

BLP40-1024

  • 厂商:

    POWER-ONE

  • 封装:

  • 描述:

    BLP40-1024 - 40 Watts - Power-One

  • 数据手册
  • 价格&库存
BLP40-1024 数据手册
BLP40 AC-DC Series Data Sheet 40 Watts Features • RoHS lead-free solder and lead-solder-exempted products are available • Industry-standard 3” x 5” footprint • Main output remote sense • CE marked to Low Voltage Directive (Pending) • Compliance to EN61000-4-2/-3/-4/-5/-6/-8 Description The BLP40 Series’ economical and compact construction provides single or three-output ac-dc power conversion to meet the requirements of networking and data communications systems, as well as commercial and industrial configurations. The BLP40 is rated for convection, as well as forced-air cooling. Full output power is available with external forced-air cooling. Other features include main-output remote sense and an internal EMI filter. Single Output Model Selection MODEL NOMINAL OUTPUT VOLTAGE (VDC) MIN-MAXIMUM OUTPUT CURRENT, CONVECTION MIN-MAXIMUM OUTPUT CURRENT 1 PEAK OUTPUT CURRENT 2 TOTAL REGULATION % 3 RIPPLE & NOISE %p-p 4 BLP40-1005 BLP40-1012 BLP40-1024 5V 12V 24V 0 to 5A 0 to 2.1A 0 to 1.1A 0 to 8A 0 to 3.3A 0 to 1.8A 9A 3.7A 1.9A ±2 ±2 ±2 1 1 1 Triple Output Model Selection MODEL NOMINAL OUTPUT VOLTAGE (VDC) MIN-MAXIMUM OUTPUT CURRENT, CONVECTION MIN-MAXIMUM OUTPUT CURRENT 1 PEAK OUTPUT CURRENT 2 TOTAL REGULATION % 3 RIPPLE & NOISE %p-p 4 BLP40-3000 BLP40-3003* +5V +12V -12V +5V +15V -15V 0.3 to 3A 0.1 to 1.5A 0.0 to 0.5A 0.3 to 3A 0.1 to 1.5A 0.0 to 0.5A 0.3 to 4A 0.1 to 2A 0.0 to 0.7A 0.3 to 4A 0.1 to 2A 0.0 to 0.7A 5A 3A 1 5A 2.5A 1A ±2 ±5 ±5 ±2 ±5 ±5 1 1 1 1 1 1 * Advanced Product Release NOTES: 1 10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side. Peak current duration for less than 30 Sec with a maximum duty cycle of 10%. 3 At 25 °C ambient including voltage set point tolerance, line, and load regulation. 4 Maximum peak-to-peak noise expressed as a percentage of output voltage, 20 MHz bandwidth, and bypass capacitors of 10 μF and 0.1 μF. 2 Ordering Information: OPTIONS SUFFIXES TO ADD TO PART NUMBER RoHS lead-solder exemption RoHS compliant for all 6 substances No RoHS suffix character required. Add “G” as the last character of the part number. REV. MAR 31, 2006 Page 1 of 5 www.power-one.com BLP40 AC-DC Series Data Sheet 40 Watts Input Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Input Voltage - AC Input Voltage - DC Input Frequency Input Current Inrush Surge Current Input Fuse Efficiency Single-phase continuous input range. Consult factory. AC input. At 115 VAC input. Internally limited. Vin = 115 VAC, Max Power, 25 °C. Internally limited. Vin = 230 VAC, Max Power, 25 °C. Internally located AC input line fuse rated at F, 250 V, 3.15 A. At Max Power. 85 47 100-250 50/60 0.8 18 36 70 264 63 VAC Hz ARMS APK APK % Output Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Output Power Output DC Adjustability: Overshoot Load Transient Turn-On Time from AC ON Turn-On Delay Hold-Up Time Remote Sense With convection cooling. With forced-air cooling. Adjustability of Vo1 (Vo2/Vo3 are not adjustable). See Model Selection Table See Model Selection Table -5%, +10% 25 40 5 ±3 1.5 20 20 500 Watts Of Nom % % Sec ms ms mV Vo1, Vo2, or Vo3 deviation due to a 50 to 100% load change at a rate of 1A/µs. Time required for output voltage to reach within regulation after initial application of AC input. Time required for output voltage to rise from 10% to 90%. At 25 W, 115 VAC Total compensation for cable losses on Vo1. (Remote Sense is not available for Vo2 or Vo3) Interface Signals and Internal Protection PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Overvoltage Protection Main output. 5 V: 12 V: 24 V: 5.7 13.8 27.6 6.8 16.2 32.4 V Short Circuit Protection Fully-protected against output short circuit. REV. MAR 31, 2006 Page 2 of 5 www.power-one.com BLP40 AC-DC Series Data Sheet 40 Watts Safety, Regulatory, and EMI Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Agency Approvals UL60950-1/CSA 22.2 No. 60950-1-03. EN 60950-1/IEC 60950-1. CB Approval. CE Mark for LVD. Input-to-Ground (Basic). 1500 2121 3000 4242 500 B B BLP40-3003 Pending Approval. Ground Continuity Dielectric Withstand Voltage 40 A VAC VDC VAC VDC VDC Class Input-to-Ouput (Reinforced). The primary to secondary test is not performed on completed assemblies. Output-to-Ground (Functional). FCC Part 15. CISPR 22 and CISPR 11. Per EN61000-4-2, level 3. Per EN61000-3-3. Per EN61000-4-3, level 3. Per EN61000-4-4, level 3. Per EN61000-4-5, class 3. Per EN61000-4-6, level 3. Per EN61000-4-8. Per EN60950. Electromagnetic Interference ESD Flicker Radiated Susceptibility EFT/Burst Input Transient Protection RF Immunity Magnetic Fields Leakage Current Conducted: Conducted: 3 Line-to-Line: Line-to-Ground: 1 1 2 3 1 BLP40-1XXX BLP40-3XXX At 264 VAC: AT 264 VAC: 0.48 0.72 V/m kV kV V/m A/m mA Environmental Specifications PARAMETER CONDITIONS/DESCRIPTION MIN NOM MAX UNITS Altitude Operating Temperature Storage Temperature Forced-Air Cooling Convection Cooling Temperature Coefficient Relative Humidity Shock Vibration Operating. Non-Operating. 0 °C to 70 °C with linear derating to 50% above 50 °C. Unit will start up at -20 °C, but will not meet all published specifications. Forced-air cooling of 150 LFM at 10 CFM is required for full output power. (NOTE 1) (See Model Selection Table). When unit is mounted horizontally with free-air convection. (See Model Selection Table). 0 °C to 70 °C (after 15-minute warm-up). Non-Condensing @ 40 °C Operating: half-sine 11 ±3ms, 3 axis. Non-operating: half-sine 11±3ms, 3 axis. Operating: Random vibration, 5-500 Hz (10 minutes each axis). Non-operating: Random vibration, 5-500 Hz (10 minutes each axis). 0 -40 25 10k 50k 70 85 ASL Ft. ASL Ft. °C °C 25 ±0.02 5 95 15 40 2.4 6.0 W %/°C %RH G Grms Grms NOTES: 1) 10 CFM or 150 LFM (average measurement of six equally-distanced points through a 3.5” x 1.6” cross-sectional area) with power supply mounted on 0.25” standoffs. Recommended airflow direction is from the AC side to the DC side. REV. MAR 31, 2006 Page 3 of 5 www.power-one.com BLP40 AC-DC Series Data Sheet 40 Watts Overall Size: 3.00" x 5.00" x 1.23" (76.2mm x 127.0mm x 31.2mm) Weight: 0.51 lb (0.23 kg) Mechanical Drawing (Single-Output Models) 5.00 (127.0) 4.55 (115.6) Ø 0.16 (4 PL) (4.1) CN1 - AC CONN. PIN 1 PIN 2 PIN 3 NEUTRAL MISSING PIN LINE CN2 - DC CON PIN 1 PIN 2 PIN 3 VOUT VOUT VOUT DC COM DC COM DC COM TOP VIEW CN1 INPUT CONNECTOR 3.00 (76.2) SECONDARY GROUND 2.55 (64.8) CN4 PIN #1 SAFETY GROUND CONNECTION POINT #2, FASTON TAB, 0.25", 0.03" THICK SAFETY GROUND CONNECTION POINT #1 PIN #1 CN2 - DC OUTPUT CONNECTOR (SEE PINOUT TABLE) PIN 4 PIN 5 PIN 6 CN3 - REMOTE SENSE.CON PIN 1 PIN 2 + SENSE - SENSE FASTENER CLEARANCE AREA 0.27" DIA (4 PL) (6.86) PIN #1 CN3 - REMOTE SENSE CONNECTOR (APPROX. LOCATION) 0.06 (1.5) 1.23 (31.2) SIDE VIEW 1.07 (27.2) END VIEW PRINTED CIRCUIT BOARD 0.1 (2.5) RECOMMENDED MATING CONNECTORS HOUSING CN1 CN2 CN3 MOLEX 09-50-8031 LEOCO 3940S030000 MOLEX 09-50-8061 LEOCO 3940S060000 MOLEX 22-01-3027 LEOCO 2530S020000 PIN 08-52-0113 3983TCB0000 08-52-0113 3983TCB0000 08-52-0113 2533TPB0000 NOTE: This is an outline drawing only. The detailed location of components is not shown. REV. MAR 31, 2006 Page 4 of 5 www.power-one.com BLP40 AC-DC Series Data Sheet 40 Watts Overall Size: 3.00" x 5.00" x 1.23" (76.2mm x 127.0mm x 31.2mm) Weight: 0.51 lb (0.23 kg) Mechanical Drawing (Triple-Output Models) 5.00 (127.0) 4.55 (115.6) CN1 - AC CONN. PIN 1 PIN 2 PIN 3 Ø 0.16 (4 PL) (4.1) NEUTRAL MISSING PIN LINE CN2 - DC CON PIN 1 PIN 2 PIN 3 V2 V1 V1 DC COM DC COM V3 TOP VIEW CN1 INPUT CONNECTOR 3.00 (76.2) PIN #1 CN2 - DC OUTPUT CONNECTOR (SEE PINOUT TABLE) PIN 4 PIN 5 PIN 6 SECONDARY GROUND CN3 - REMOTE SENSE.CON PIN 1 PIN 2 + SENSE - SENSE 2.55 (64.8) CN4 PIN #1 SAFETY GROUND CONNECTION POINT #2, FASTON TAB, 0.25", 0.03" THICK SAFETY GROUND CONNECTION POINT #1 FASTENER CLEARANCE AREA (4 PL) 0.27" DIA (6.86) PIN #1 CN3 - REMOTE SENSE CONNECTOR (APPROX. LOCATION) 0.06 (1.5) 1.23 (31.2) SIDE VIEW 1.07 (27.2) END VIEW PRINTED CIRCUIT BOARD 0.1 (2.5) RECOMMENDED MATING CONNECTORS HOUSING CN1 CN2 CN3 MOLEX 09-50-8031 LEOCO 3940S030000 MOLEX 09-50-8061 LEOCO 3940S060000 MOLEX 22-01-3027 LEOCO 2530S020000 PIN 08-52-0113 3983TCB0000 08-52-0113 3983TCB0000 08-52-0113 2533TPB0000 NOTE: This is an outline drawing only. The detailed location of components is not shown. NUCLEAR AND MEDICAL APPLICATIONS - Power-One products are not designed, intended for use in, or authorized for use as critical components in life support systems, equipment used in hazardous environments, or nuclear control systems without the express written consent of the respective divisional president of Power-One, Inc. TECHNICAL REVISIONS - The appearance of products, including safety agency certifications pictured on labels, may change depending on the date manufactured. Specifications are subject to change without notice. REV. MAR 31, 2006 Page 5 of 5 www.power-one.com
BLP40-1024 价格&库存

很抱歉,暂时无法提供与“BLP40-1024”相匹配的价格&库存,您可以联系我们找货

免费人工找货