0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B-13-1250-T3-SSC2EGR

B-13-1250-T3-SSC2EGR

  • 厂商:

    SOURCE

  • 封装:

  • 描述:

    B-13-1250-T3-SSC2EGR - 1.25 Gbps Single Mode Transceiver - Source Photonics, Inc.

  • 数据手册
  • 价格&库存
B-13-1250-T3-SSC2EGR 数据手册
1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Features • SC Duplex Single Mode Transceiver • Industry Standard 1x9 Footprint • Gigabit Ethernet Compliant • Single +3.3/5V Power Supply • PECL Differential Inputs and Outputs • PECL/LVPECL Signal Detection Output [C-13-1250-T(3)-SSC(2)] • TTL/LVTTL Signal Detection Output [C-13-1250C-T(3)-SSC(2)] • Wave Solderable and Aqueous Washable • Uncooled laser diode with MQW structure • Complies with Telcordia (Bellcore) GR-468-CORE • Gigabit Ethernet Application • RoHS compliance available Absolute Maximum Rating Parameter Power Supply Voltage Power Supply Voltage Output Current Soldering Temperature Storage Temperature Symbol Vcc Vcc Iout - Min. 0 0 0 -40 Max. 3.6 6 30 260 85 Unit V V mA ºC ºC Note C-13-1250(C)-T3-SSC(2) C-13-1250(C)-T-SSC(2) 10 seconds on leads only Tstg Recommended Operating Condition Parameter Power Supply Voltage 1 Power Supply Voltage 1 Operating Temperature1 Operating Temperature1 Data Rate Note1: Please refer to ordering information Symbol Vcc Vcc Topr Topr Min. 3.1 4.75 0 -40 Typ. 3.3 5 1250 Max. 3.5 5.25 70 85 Unit V V ºC ºC Mbps LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Transmitter Specifications Parameter Optical Transmit Power Optical Transmit Power Output center Wavelength Output center Wavelength Output Spectrum Width Output Spectrum Width Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Relative Intensity Noise Total Jitter tr tf RIN TJ Symbol Po Po λ λ ∆λ ∆λ ER Min -10 -5 1270 1275 9 Typical 1310 1310 Max -3 0 1355 1350 4 2.5 0.26 0.26 -120 0.27 Unit dBm dBm nm nm nm nm dB ns ns dB/Hz ns Measured with 27-1 PRBS 20% to 80% Values 20% to 80% Values Notes C-13-1250(C)-T(3)-SSC C-13-1250(C)-T(3)-SSC2 C-13-1250(C)-T(3)-SSC C-13-1250(C)-T(3)-SSC2 RMS(σ), C-13-1250(C)-T(3)-SSC RMS(σ), C-13-1250(C)-T(3)-SSC2 Compliant with IEEE 802.3 Transmitter Specifications Parameter Power Supply Current Data Input Current-Low Data Input Current-High Differential Input Voltage Data Input Voltage-Low Data Input Voltage-High Symbol ICC IIL IIH VIH-VIL VIL-VCC VIH-VCC Min -350 300 -2.0 -1.1 Typical Max 180 350 -1.58 -0.74 Unit mA µA µA mV V V These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs Notes Maximum current is specified at Vcc= Maximum @ maximum temperature LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Receiver Specifications Parameter Sensitivity2 Maximum Input Power Signal Detect-Asserted Signal Detect-Deasserted Signal Detect-Hysteresis Wavelength of Operation Note 2: Measured with 27-1 PRBS, BER= 10-12 Symbol Pin Pa Pd Min 0 -38 1 1100 Typical Max -24 -24 1600 Unit dBm dBm dBm dBm dB nm Measured on transition: low to high Measured on transition: high to low Notes Receiver Specifications Parameter Power Supply Current Data output Voltage-Low Data output Voltage-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High Symbol ICC VOL -Vcc VOH- Vcc VSDL VSDH VSDL-Vcc VSDH- Vcc Min -2.0 -1.1 2.0 -2.0 -1.1 Typical Max 100 -1.58 -0.74 0.5 -1.58 -0.74 Unit mA V V V V V V Note The current excludes the output load current These outputs are compatible with 10K, 10KH and 100KECL and LVPECL outputs C-13-1250C-T(3)-SSC(2) C-13-1250-T(3)-SSC(2) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Connection Diagram 1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND) NC Top View NC Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data In Transmitter Signal Ground PIN 1 2 3 4 5 6 7 8 Warnings 9 Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal DCc power for the receiver section DC power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Recommended Circuit Schematic C-13-1250-T(3)-SSC(2) Tx Vcc C5 Rx Vcc 9 R1 R3 8 7 65 43 2 1 R9 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 SD R10 R6 No internal connection Transceiver Top view No internal connection R8 L1 Vcc Notes +3.3V: R1=R3=R5=R7=R9=130 R2=R4=R6=R8=R10=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H Notes +5V: R1=R3=R5=R7=R9=82 R2=R4=R6=R8=R10=130 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H C3 C1 Rx Vcc L2 C4 C2 Tx Vcc C-13-1250C-T(3)-SSC(2) Tx Vcc C5 Rx Vcc 9 R1 R3 8 7 65 43 2 1 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 SD R6 R8 No internal connection Transceiver Top view No internal connection L1 Vcc Notes +3.3V: R1=R3=R5=R7=130 R2=R4=R6=R8=82 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H Notes +5V: R1=R3=R5=R7=82 R2=R4=R6=R8=130 C1=C2=C3=C5=C6=0.1F C4=10F L1=L2=1H C3 C1 Rx Vcc L2 C4 C2 Tx Vcc The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Package Diagram (10.4 mm SC transceiver assembly) Top View Front View Units: mm Side View Rear View Package Option: Blank, A = black case LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Package Diagram (9.8 mm SC transceiver assembly) Top View Front View Units: mm x8 Side View Rear View Package Option : B, E = Blue case C, D = Black case LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 7 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Ordering Information Available Options:  C-13-1250-T-SSC(A/B/C/D/E) C-13-1250C-T-SSC(A/B/C/D/E) C-13-1250-T3-SSC(A/B/C/D/E) C-13-1250C-T3-SSC(A/B/C/D/E) C-13-1250-T-SSC2(A/B/C/D/E) C-13-1250C-T-SSC2(A/B/C/D/E) C-13-1250-T3-SSC2(A/B/C/D/E) C-13-1250C-T3-SSC2(A/B/C/D/E)   C-13-1250-T-SSC(A/B/C/D/E)-G5 C-13-1250C-T-SSC(A/B/C/D/E)-G5 C-13-1250-T3-SSC(A/B/C/D/E)-G5 C-13-1250C-T3-SSC(A/B/C/D/E)-G5 C-13-1250-T-SSC2(A/B/C/D/E)-G5 C-13-1250C-T-SSC2(A/B/C/D/E)-G5 C-13-1250-T3-SSC2(A/B/C/D/E)-G5 C-13-1250C-T3-SSC2(A/B/C/D/E)-G5   C-13-1250-T-SSC(A/B/C/D/E)-GR C-13-1250C-T-SSC(A/B/C/D/E)-GR C-13-1250-T3-SSC(A/B/C/D/E)-GR C-13-1250C-T3-SSC(A/B/C/D/E)-GR C-13-1250-T-SSC2(A/B/C/D/E)-GR C-13-1250C-T-SSC2(A/B/C/D/E)-GR C-13-1250-T3-SSC2(A/B/C/D/E)-GR C-13-1250C-T3-SSC2(A/B/C/D/E)-GR Part numbering Definition: C - 13 - 1250(C) - T(3) - S SC TxPower Temperature and Package RoHs • 13 = Wavelength 1310nm • Communication protocol (1250 Mbps) 1250 = PECL Signal Detection Output 1250C = TTL Signal Detection Output • T = +5V Transceiver, FP T3= +3.3V Transceier, FP • Single mode fiber • Connector options • Tx Power range Blank = -3 to -10 dBm 2 = -5 to 0 dBm • Temperature range and package Blank = commercial temperature(0 to 70 ºC), 10.4 mm, Black case A = industrial temperature(-40 to 85 ºC), 10.4 mm, Black case B = industrial temperature(-40 to 85 ºC), 9.8 mm, Blue case C = industrial temperature(-40 to 85 ºC), 9.8 mm, Black case D = commercial temperature(0 to 70 ºC), 9.8 mm, Black case E = commercial temperature(0 to 70 ºC), 9.8 mm, Blue case • RoHS compliance available Blank = RoHS non-compliant product G5 = RoHS 5/6-compliant product (lead exemption) GR = Full RoHS compliant product (no exemption) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 8 LUMNDS601-May1806 Rev A.3 1.25 Gbps Single Mode Transceiver C-13-1250(C)-T(3)-SSC(2) Warnings: Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notes: IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 9 LUMNDS601-May1806 Rev A.3
B-13-1250-T3-SSC2EGR 价格&库存

很抱歉,暂时无法提供与“B-13-1250-T3-SSC2EGR”相匹配的价格&库存,您可以联系我们找货

免费人工找货