0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
B-13-1250-TDPM3-SSC-60

B-13-1250-TDPM3-SSC-60

  • 厂商:

    SOURCE

  • 封装:

  • 描述:

    B-13-1250-TDPM3-SSC-60 - 1.25 Gbps Bi-directional Single Fiber Transceiver - Source Photonics, Inc.

  • 数据手册
  • 价格&库存
B-13-1250-TDPM3-SSC-60 数据手册
1.25 Gbps Bi-directional Single Fiber Transceiver B-15/13-1250(C)-TDPM3-SXX-60 Features • Coaxial single mode single fiber package with optional SC/FC/ST/MU connector • Wavelength Tx 1550 nm/ Rx 1310nm • Compliant with IEEE 802.3z Gigabit Ethernet • Single +3.3V Power Supply • LVPECL Differential Inputs and Outputs • LVPECL SD Output (B-15/13-1250-TDPM3-SXX-60) • LVTTL SD Output (B-15/13-1250C-TDPM3-SXX-60) • Wave Solderable and Aqueous washable • Class 1 Laser Int. Safety Standad IEC 825 Compliant • Uncooled laser diode with MQW structure • Complies with Telcordia (Bellcore) GR-468-CORE • Temperature Range: 0 to 70ºC • Optical Isolation >30 dB • Cross Talk < -33 dB • Optical Return Loss > 14dB Absolute Maximum Rating Parameter Power Supply Voltage Output Current Soldering Temperature Operating Temperature Storage Temperature Symbol Vcc Iout - Min. 0 0 -40 Max. 3.6 30 260 70 85 Unit V mA ºC ºC ºC Note 10 seconds on leads only Topr Tstg Recommended Operating Condition Parameter Power Supply Voltage Operating Temperature (Case) Data Rate Transmitter Specifications Parameter Optical Optical Transmit Power Output center Wavelength Output Spectrum Width Side Mode Suppression Ratio Extinction Ratio Output Eye Optical Rise Time Optical Fall Time Optical Isolation Optical Return Loss Relative Intensity Noise Total Jitter tr tf - Symbol Vcc Topr - Min. 3.1 0 - Typ. 3.3 1250 Max. 3.5 70 - Unit V ºC Mbps Symbol Min Typical Max Unit Notes Output power is coupled into a 9/125 µm single mode fiber -20dB CW1 P0=5mW Po λ ∆λ Sr ER -10 1500 30 9 30 14 - 1550 35 - -4 1600 1 1 0.26 0.26 -120 0.27 dBm nm nm dB dB ns ns dB dB dB/Hz ns Compliant with IEEE 802.3z 20% to 80% Values 20% to 80% Values Tx:1550 nm/ Rx:1310 nm RIN TJ Measured with 27-1 LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 1 LUMNDS574-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-15/13-1250(C)-TDPM3-SXX-60 Transmitter Specifications Parameter Electrical Power Supply Current Data Input Current-Low Data Input Current-High Differential Input Voltage Data Input Voltage-Low Data Input Voltage-High ICC IIL IIH VIH-VIL VIL-VCC VIH-VCC -350 300 -2.0 -1.1 150 350 -1.58 -0.74 mA µA µA mV V V These inputs are compatible with 10K, 10KH and 100K ECL and PECL inputs Maximum current is specified at Vcc= Maximum @ maximum temperature Symbol Min Typical Max Unit Notes Receiver Specifications Parameter Optical Sensitivity Maximum Input Power Signal Detect-Asserted Signal Detect-Deasserted Signal Detect-Hysteresis Cross Talk Wavelength of Operation Pin Pa Pd -3 -35 1260 3.0 -22 -22 -33 1360 dBm dBm dBm dBm dB dB nm Measured on transition: low to high Measured on transition: high to low Measured with 27-1 PRBS, BER 10-12 Symbol Min Typical Max Unit Notes Receiver Specifications Parameter Electrical Power Supply Current Data Output Voltage-Low Data Output Voltage-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High Signal Detect Output Voltage-Low Signal Detect Output Voltage-High ICC VOL -Vcc VOH- Vcc VSDL-Vcc VSDH- Vcc VSDL VSDH -1.9 -1.1 -1.9 -1.1 2 100 -1.6 -0.8 -1.6 -0.8 0.5 mA V V V V V V The current excludes the output load current These outputs are compatible with 10K, 10KH and 100KECL and PECL outputs B-15/13-1250-TDPM3-SXX-60 B-15/13-1250C-TDPM3-SXX-60 Symbol Min Typical Max Unit Note LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 2 LUMNDS574-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-15/13-1250(C)-TDPM3-SXX-60 Connection Diagram 1. (Rx GND) 2. (Rx +) 3. (Rx-) 4. (SD) 5. (Rx Vcc) 6. (Tx Vcc) 7. (TX-) 8. (TX+) 9. (Tx GND) NC Top View NC Receiver Signal Ground Receiver Data Out Receiver Data Out Bar Signal Detect Receiver Power Supply Transmitter Power Supply Transmitter Data In Bar Transmitter Data in Transmitter Signal Ground PIN 1 2 3 4 5 6 7 8 Warnings 9 Symbol RxGND RD+ RDSD RxVcc TxVcc TDTD+ TxGND Notes Directly connect this pin to the receiver ground plane See recommended circuit schematic See recommended circuit schematic Active high on this indicates a received optical signal +3.3V dc power for the receiver section +3.3V dc power for the transmitter section See recommended circuit schematic See recommended circuit schematic Directly connect this pin to the transmitter ground plane LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 3 LUMNDS574-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-15/13-1250(C)-TDPM3-SXX-60 Recommended Circuit Schematic B-15/13-1250-TDPM3-SXX-60 Tx Vcc C5 Rx Vcc 9 R1 R3 8 7 6 5 43 2 1 R9 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 R10 SD R6 R8 No internal connection Transceiver Top view No internal connection L1 Rx Vcc C1 Notes +3.3V: R1=R3=R5=R7=R9=130! R2=R4=R6=R8=R10=82! C1=C2=C3=C5=C6=0.1"F C4=10"F L1=L2=1"H B-15/13-1250C-TDPM3-SXX-60 Vcc C3 L2 C4 Tx Vcc C2 Tx Vcc C5 Rx Vcc 9 R1 R3 8 7 6 5 43 2 1 R5 R7 C6 TD + TD - RD + RD - Tx Vcc Rx Vcc R2 R4 R6 R8 SD No internal connection Transceiver Top view No internal connection L1 Rx Vcc C1 Notes +3.3V: R1=R3=R5=R7=130! R2=R4=R6=R8=82! C1=C2=C3=C5=C6=0.1"F C4=10"F L1=L2=1"H Vcc C3 L2 C4 Tx Vcc C2 The split-loaded terminations for ECL signals need to be located at the input of devices receiving those ECL signals. The power supply filtering is required for good EMI performance. Use short tracks from the inductor L1/L2 to the module Rx Vcc. A GND plane under the module is required for good EMI and sensitivity performance. LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 4 LUMNDS574-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-15/13-1250(C)-TDPM3-SXX-60 Package Diagram Diplexer Transceiver Assembly Top View max Front View Side View Rear View Units in mm (inch) LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 5 LUMNDS574-AUG1804 rev. A.0 1.25 Gbps Bi-directional Single Fiber Transceiver B-15/13-1250(C)-TDPM3-SXX-60 Ordering Information Available Options:  B-15/13-1250(C)-TDPM3-SSC-60 B-15/13-1250(C)-TDPM3-SST-60 B-15/13-1250(C)-TDPM3-SFC-60 B-15/13-1250(C)-TDPM3-SMU-60 B - 15/13 - 1250(C) - TDPM3 - S XX -60 • Wavelength Tx Wavelength=1550nm Rx Wavelength=1310nm • Communication protocol (1250 Mbps) 1250=LVPECL Signal Detection Output 1250C=LVTTL Signal Detection Output • +3.3 V Transceiver • Single mode fiber • Connector options (SC/ST/FC/MU) • Length of Pigtail Fiber = 660 ± 20 mm Warnings Handling Precautions: This device is susceptible to damage as a result of electrostatic discharge (ESD). A static free environment is highly recommended. Follow guidelines according to proper ESD procedures. Laser Safety: Radiation emitted by laser devices can be dangerous to human eyes. Avoid eye exposure to direct or indirect radiation. Legal Notice IMPORTANT NOTICE! All information contained in this document is subject to change without notice, at LuminentOIC’s sole and absolute discretion. LuminentOIC warrants performance of its products to current specifications only in accordance with the company’s standard one-year warranty; however, specifications designated as “preliminary” are given to describe components only, and LuminentOIC expressly disclaims any and all warranties for said products, including express, implied, and statutory warranties, warranties of merchantability, fitness for a particular purpose, and non-infringement of proprietary rights. Please refer to the company’s Terms and Conditions of Sale for further warranty information. LuminentOIC assumes no liability for applications assistance, customer product design, software performance, or infringement of patents, services, or intellectual property described herein. No license, either express or implied, is granted under any patent right, copyright, or intellectual property right, and LuminentOIC makes no representations or warranties that the product(s) described herein are free from patent, copyright, or intellectual property rights. Products described in this document are NOT intended for use in implantation or other life support applications where malfunction may result in injury or death to persons. LuminentOIC customers using or selling products for use in such applications do so at their own risk and agree to fully defend and indemnify LuminentOIC for any damages resulting from such use or sale. THE INFORMATION CONTAINED IN THIS DOCUMENT IS PROVIDED ON AN “AS IS” BASIS. Customer agrees that LuminentOIC is not liable for any actual, consequential, exemplary, or other damages arising directly or indirectly from any use of the information contained in this document. Customer must contact LuminentOIC to obtain the latest version of this publication to verify, before placing any order, that the information contained herein is current. © LuminentOIC, Inc. 2003 All rights reserved LUMINENTOIC.COM 20550 Nordhoff St. • Chatsworth, CA 91311 • tel: 818.773.9044 • fax: 818.576.9486 9F, No 81, Shui Lee Rd. • Hsinchu, Taiwan, R.O.C. • tel: 886.3.5169222 • fax: 886.3.5169213 6 LUMNDS574-AUG1804 rev. A.0
B-13-1250-TDPM3-SSC-60 价格&库存

很抱歉,暂时无法提供与“B-13-1250-TDPM3-SSC-60”相匹配的价格&库存,您可以联系我们找货

免费人工找货