0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PBA300F-36

PBA300F-36

  • 厂商:

    TOTAL-POWER

  • 封装:

  • 描述:

    PBA300F-36 - PBA300F - Total Power International

  • 数据手册
  • 价格&库存
PBA300F-36 数据手册
Unit type O rdering information PBA300F R PBA 300 1 2 3 F 4 -5 5 -O 1Series name 2 Output wattage 3 Universal input 4 Output voltage 5 Optional C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F3 :Reverse air exhaust type F4 :Low speed fan Refer to instruction manual 7.1 MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA300F-3R3 198 ACIN 100V 3.3V 60A ACIN 200V *3 3.3V 60A PBA300F-5 300 5V 60A 5V 60A PBA300F-7R5 PBA300F-12 300 324 7.5V 40A 12V 27A 7.5V 40A 12V 27A PBA300F-15 330 15V 22A 15V 22A PBA300F-24 PBA300F-36 336 324 24V 14A 36V 9A 24V 14(16.5)A 36V 9A PBA300F-48 336 48V 7A 48V 7A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT EFFICIENCY[%] PBA300F-3R3 PBA300F-5 PBA300F-7R5 PBA300F-12 PBA300F-15 AC85 - 264 1f or DC120 - 350 (AC50 or DC70 optionally available *4) ACIN 100V 3typ 4.1typ ACIN 200V 1.6typ 2typ 50/60 (47 - 63) 68typ 74typ 76typ 78typ 78typ 79typ 81typ 71typ 77typ 79typ 81typ 81typ 82typ 84typ 0.98typ (Io=100%) 0.95typ (Io=100%) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More then 3 sec. to re-start) 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) 3.3 5 7.5 12 15 60 60 20max 40max 80max 140max 60 60 20max 40max 80max 140max 40 40 36max 60max 120max 160max 27 27 48max 100max 120max 160max 22 22 60max 120max 120max 160max 24 14 14(16.5) 96max 150max 120max 160max 36 9 9 144max 150max 150max 160max 79typ 82typ PBA300F-24 PBA300F-36 PBA300F-48 ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V CURRENT[A] ACIN 200V *3 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -20 - 0C *1 48 7 7 192max 300max 150max 400max OUTPUT to C 1 120max 150max 150max 150max 150max 200max 200max RIPPLE NOISE[mVp-p] 020 +50C* 1 120max - - 0 * 160max 160max 180max 180max 180max 180max 240max 500max 0 to +50C *1 40max 50max 75max 120max 150max 240max 360max 480max TEMPERATURE REGULATION[mV] -20 to +50C *1 60max 75max 120max 180max 180max 290max 440max 600max DRIFT[mV] *2 12max 20max 30max 48max 60max 96max 144max 192max START-UP TIME[ms] 300typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off the input voltage. HOLD-UP TIME[ms] 20typ (ACIN 100/200V, Io=100%) OUTPUT VOLTAGE ADJUSTMENT RANGE[V] 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 38.40 - 56.00 OUTPUT VOLTAGE SETTING[V] 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 48.00 - 49.92 OVERCURRENT PROTECTION Works over 105% of rated current or 101% of peak current and recovers automatically 43.2 - 54.0 57.6 - 80.0 6.5 - 8.0 9.0 - 11.6 14.4 - 18.6 18.0 - 23.3 28.8 - 37.2 PROTECTION OVERVOLTAGE PROTECTION[V] 4.3 - 6.3 CIRCUIT AND OPERATING INDICATION LED (Green) OTHERS REMOTE SENSING Provided REMOTE ON/OFF Provided INPUT-OUTPUT -RC AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) INPUT-FG AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) ISOLATION OUTPUT-RC-AUX-FG AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) OUTPUT-RC -AUX AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature) OPERATING TEMP.,HUMID.AND ALTITUDE -20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max , ENVIRONMENT STORAGE TEMP. HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS SAFETY AND CONDUCTED NOISE NOISE REGULATIONS CE MARKING HARMONIC ATTENUATOR CASE SIZE/WEIGHT OTHERS COOLING METHOD *1 *2 *3 *4 * -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 102X42X170mm (without terminal block and screw) (WXHXD) /1.0kg max Forced cooling (internal fan) Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. Derating is required.Consult us for details. A sound may occur from power supply at pulse loading.
PBA300F-36 价格&库存

很抱歉,暂时无法提供与“PBA300F-36”相匹配的价格&库存,您可以联系我们找货

免费人工找货