0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PBA600F-12

PBA600F-12

  • 厂商:

    TOTAL-POWER

  • 封装:

  • 描述:

    PBA600F-12 - PBA600F - Total Power International

  • 数据手册
  • 价格&库存
PBA600F-12 数据手册
Unit type Ordering information PBA PBA600F R PBA 600 1 2 3 F 4 -5 5 -O 1 Series name 2 Output wattage 3 Universal input 4 Output voltage 5 Optional C :with Coating G :Low leakage current U :Operation stop voltage is set at a lower value F1 :With Long-Life fan F3 :Reverse air exhaust type F4 :Low speed fan Refer to instruction manual 7.1 MODEL MAX OUTPUT WATTAGE[W] DC OUTPUT PBA600F-3R3 396 ACIN 100V 3.3V 120A ACIN 200V *3 3.3V 120A PBA600F-5 600 5V 120A 5V 120A PBA600F-7R5 600 7.5V 80A 7.5V 80A PBA600F-12 636 12V 53A 12V 53A PBA600F-15 645 15V 43A 15V 43A PBA600F-24 648 24V 27A 24V 27(31)A PBA600F-36 648 36V 18A 36V 18A PBA600F-48 624 48V 13A 48V 13A SPECIFICATIONS MODEL VOLTAGE[V] CURRENT[A] FREQUENCY[Hz] INPUT ACIN 100V ACIN 200V ACIN 100V POWER FACTOR ACIN 200V ACIN 100V INRUSH CURRENT[A] ACIN 200V LEAKAGE CURRENT[mA] VOLTAGE[V] ACIN 100V CURRENT[A] ACIN 200V *3 LINE REGULATION[mV] LOAD REGULATION[mV] 0 to +50C *1 RIPPLE[mVp-p] -20 - 0C *1 0 to +50C *1 RIPPLE NOISE[mVp-p] -20 - 0C *1 0 to +50C *1 TEMPERATURE REGULATION[mV] -20 to +50C *1 DRIFT[mV] *2 START-UP TIME[ms] HOLD-UP TIME[ms] OUTPUT VOLTAGE ADJUSTMENT RANGE[V] OUTPUT VOLTAGE SETTING[V] OVERCURRENT PROTECTION OVERVOLTAGE PROTECTION[V] *4 OPERATING INDICATION REMOTE SENSING REMOTE ON/OFF INPUT-OUTPUT -RC INPUT-FG OUTPUT-RC-AUX-FG OUTPUT-RC -AUX OPERATING TEMP.,HUMID.AND ALTITUDE STORAGE TEMP.,HUMID.AND ALTITUDE VIBRATION IMPACT AGENCY APPROVALS CONDUCTED NOISE CE MARKING HARMONIC ATTENUATOR CASE SIZE/WEIGHT COOLING METHOD EFFICIENCY[%] ACIN 100V ACIN 200V PBA600F-3R3 PBA600F-5 PBA600F-7R5 PBA600F-12 PBA600F-15 PBA600F-24 PBA600F-36 AC85 - 264 1f or DC120 - 350 5.8typ 8.2typ 3typ 4.1typ 50/60 (47 - 63) 70typ 75typ 76typ 79typ 79typ 81typ 82typ 72typ 77typ 79typ 82typ 82typ 84typ 84typ 0.98typ (Io=100%) 0.95typ (Io=100%) 20/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start) 40/40typ (Io=100%) (Primary inrush current /Secondary inrush current) (More than 3 sec. to re-start) 0.45/0.75max (ACIN 100V/240V 60Hz, Io=100%, According to IEC60950-1) 3.3 5 7.5 12 15 24 36 120 120 80 53 43 27 18 120 120 80 53 43 27(31) 18 20max 20max 36max 48max 60max 96max 144max 40max 40max 60max 100max 120max 150max 150max 80max 80max 120max 120max 120max 120max 150max 140max 140max 160max 160max 160max 160max 160max 120max 120max 150max 150max 150max 150max 200max 160max 160max 180max 180max 180max 180max 240max 40max 50max 75max 120max 150max 240max 360max 60max 75max 120max 180max 180max 290max 440max 12max 20max 30max 48max 60max 96max 144max 400typ(ACIN 100/200V, Io=100%) Start-up time is 500ms typ for less than 1minute of applying input again from turning off 20typ (ACIN 100/200V, Io=100%) 2.64 - 3.96 3.96 - 6.00 5.25 - 8.25 8.25 - 13.20 10.50 - 16.50 16.50 - 26.40 25.20 - 39.60 3.30 - 3.40 5.00 - 5.15 7.50 - 7.80 12.00 - 12.48 15.00 - 15.60 24.00 - 24.96 36.00 - 37.44 Works over 105% of rated current or 101% of peak current and recovers automatically Vo+0.66 - 1.32 Vo+1.0 - 2.0 Vo+1.5 - 3.0 Vo+2.4 - 4.8 Vo+3.0 - 6.0 Vo+4.8 - 9.6 Vo+7.2 - 14.4 LED (Green) Provided Provided AC3,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC2,000V 1minute, Cutoff current = 10mA, DC500V 50MWmin (At Room Temperature) AC500V 1minute, Cutoff current = 100mA, DC500V 50MWmin (At Room Temperature) AC100V 1minute, Cutoff current = 100mA, DC100V 50MWmin (At Room Temperature) -20 to +71C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max -20 to +75C, 20 - 90%RH (Non condensing) 3,000m (10,000feet) max 19.6m/s2 (2G), 10 - 55Hz, 3minutes period, 60minutes each along X, Y and Z axis 196.1m/s2 (20G), 11ms, once each X, Y and Z axis UL60950-1, C-UL(CSA60950-1), EN60950-1, EN50178 Complies with DEN-AN (At only AC input) Complies with FCC Part15 classB, VCCI-B, CISPR22-B, EN55011-B, EN55022-B Low Voltage Directive, EMC Directive Complies with IEC61000-3-2 120X61X190mm (without terminal block and screw) (WXHXD) /1.6kg max Forced cooling (internal fan) PBA600F-48 81typ 83typ OUTPUT 48 13 13 192max 300max 150max 400max 200max 500max 480max 600max 192max the input voltage. 38.40 - 56.00 48.00 - 49.92 Vo+4.8 - 12.0 PROTECTION CIRCUIT AND OTHERS ISOLATION ENVIRONMENT SAFETY AND NOISE REGULATIONS OTHERS *1 *2 *3 *4 * Measured by 20MHz oscilloscope or Ripple-Noise meter(equivalent to KEISOKU-GIKEN : RM101). Drift is the change in DC output for an eight hour period after a half-hour warm-up at 25C. () means peak current. Peak loading for 10s. And Duty 35% max, refer to Instruction manual in detail. Overvoltage protection circuit to follow to output voltage setting. A sound may occur from power supply at pulse loading. A-14
PBA600F-12 价格&库存

很抱歉,暂时无法提供与“PBA600F-12”相匹配的价格&库存,您可以联系我们找货

免费人工找货