Additional Resources:
Product Page
|
3D Model
date
11/25/2022
page
1 of 6
SERIES: PYB10-T & PYB10-U │ DESCRIPTION: DC-DC CONVERTER
FEATURES
•
•
•
•
•
•
•
•
•
•
•
•
up to 10 W isolated output
industry standard pinout
4:1 input range (9~36 V, 18~75 V)
smaller package
single/dual regulated outputs
1,500 Vdc isolation
continuous short circuit, over voltage protection
reverse polarity protection on chassis mount (-T) option
temperature range (-40~85°C)
six-sided metal shielding
efficiency up to 88%
EN/BS EN 62368-1 certified
MODEL
input
voltage
output
voltage
output
current
output
power
ripple
and noise1
efficiency2
typ
(Vdc)
range
(Vdc)
(Vdc)
min
(mA)
max
(mA)
max
(W)
max
(mVp-p)
typ
(%)
PYB10-Q24-S36
24
9~36
3.3
120
2400
8
80
79
PYB10-Q24-S5
24
9~36
5
100
2000
10
80
82
PYB10-Q24-S126
24
9~36
12
42
833
10
80
86
PYB10-Q24-S15
24
9~36
15
33
667
10
80
87
PYB10-Q24-S244,6
24
9~36
24
21
416
10
80
87
4,5,6
PYB10-Q24-D5
24
9~36
±5
±50
±1000
10
80
83
PYB10-Q24-D124,6
24
9~36
±12
±21
±416
10
80
86
PYB10-Q24-D15
24
9~36
±15
±16
±333
10
80
88
PYB10-Q48-S34,5
48
18~75
3.3
120
2400
8
80
79
PYB10-Q48-S5
48
18~75
5
100
2000
10
80
82
PYB10-Q48-S12
48
18~75
12
42
833
10
80
86
PYB10-Q48-S15
48
18~75
15
33
667
10
80
87
PYB10-Q48-S244,5
48
18~75
24
21
416
10
80
87
PYB10-Q48-D5
48
18~75
±5
±50
±1000
10
80
83
PYB10-Q48-D124
48
18~75
±12
±21
±416
10
80
86
PYB10-Q48-D15
48
18~75
±15
±16
±333
10
80
88
6
4,5,6
4,6
4,5
4
4
4,5
Notes:
1.
2.
3.
4.
5.
6.
Ripple and noise are measured at 20 MHz BW by “parallel cable” method
Efficiency is approximately 2% lower for Chassis Mount (-T) models.
EN 62398-1 certification does not apply to U-frame models.
Chassis mount version discontinued.
U-frame version discontinued.
Model is not CE certified.
PART NUMBER KEY
PYB10 - QXX - XXX - X
Base Number
Input Voltage
Output
S = single
D = dual
cui.com
Output Voltage
Mounting Type
T = Chassis mount
U = U-Frame3
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PYB10-T & PYB10-U │ DESCRIPTION: DC-DC CONVERTER
date 11/25/2022 │ page 2 of 6
INPUT
parameter
conditions/description
operating input voltage
24 V input models
48 V input models
start-up voltage
24 V input models
48 V input models
surge voltage
for maximum of 1 second
24 V input models
48 V input models
filter
pi filter
min
typ
max
units
9
18
24
48
36
75
Vdc
Vdc
9
18
Vdc
Vdc
50
100
Vdc
Vdc
3
mA
-0.7
-0.7
models ON (CTRL open or connect high level, 3.5-12 Vdc)
CTRL1
models OFF (CTRL connect GND or low level, 0-1.2 Vdc)
input current (models OFF)
Note:
1
1. CTRL pin voltage is referenced to GND.
OUTPUT
parameter
conditions/description
typ
max
units
line regulation
full load, input voltage from low to high
min
±0.2
±0.5
%
load regulation
5% to 100% load
±0.5
±1
%
cross regulation
dual output models:
main output 50% load, secondary output from
10% to 100% load
±5
%
voltage accuracy
±1
±2
%
voltage balance2
dual output, balanced loads
±0.5
±1.5
%
switching frequency
PWM mode
350
transient recovery time
25% load step change
300
transient response deviation
25% load step change
±3
temperature coefficient
100% load
Note:
KHz
500
μs
±5
%
±0.03
%/°C
2. For dual output models, unbalanced load can not exceed ±5%. If ±5% is exceeded, it may not meet all specifications.
PROTECTIONS
parameter
conditions/description
short circuit protection
continuous, automatic recovery
over voltage protection
min
typ
max
units
110
120
140
%Vo
min
typ
max
units
SAFETY AND COMPLIANCE
parameter
conditions/description
isolation voltage
for 1 minute at 1 mA max.
1,500
Vdc
isolation resistance
at 500 Vdc
1,000
MΩ
safety approvals
certified to 62368-1: EN
conducted emissions
CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)
radiated emissions
CISPR22/EN55022, class A, class B (external circuit required, see Figure 1-b)
ESD
IEC/EN61000-4-2, class B, contact ± 4kV
radiated immunity
IEC/EN61000-4-3, class A, 10V/m
EFT/burst
IEC/EN61000-4-4, class B, ± 2kV (external circuit required, see Figure 1-a)
surge
IEC/EN61000-4-5, class B, ± 2kV (external circuit required, see Figure 1-a)
conducted immunity
IEC/EN61000-4-6, class A, 3 Vr.m.s
voltage dips & interruptions
IEC/EN61000-4-29, class B, 0%-70%
MTBF
as per MIL-HDBK-217F @ 25°C
RoHS compliant
yes
1,000,000
cui.com
hours
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PYB10-T & PYB10-U │ DESCRIPTION: DC-DC CONVERTER
date 11/25/2022 │ page 3 of 6
ENVIRONMENTAL
parameter
conditions/description
min
max
units
operating temperature
see derating curve
-40
85
°C
-55
125
°C
5
95
%
105
°C
storage temperature
storage humidity
non-condensing
case temperature
at full load, Ta=71°C
vibration
10~55 Hz for 30 min. along X, Y and Z axis
typ
10
G
MECHANICAL
parameter
conditions/description
dimensions
chassis mount: 76.0 x 31.5 x 21.2
U-Frame: 52.32 x 54.99 x 19.05
min
case material
aluminum alloy
weight
chassis mount
U-Frame
typ
max
units
mm
mm
44
58
g
g
MECHANICAL DRAWING
CHASSIS MOUNT
units: mm[inch]
tolerance: ±0.5[±0.020]
Wire range: 24~12 AWG
PIN CONNECTIONS
PIN
Single
Output
Dual
Output
1
CTRL
CTRL
2
GND
GND
3
Vin
Vin
4
0V
-Vo
5
NC
0V
6
+Vo
+Vo
4
5
6
1
2
3
Top View
Front View
U-FRAME
54.99 2.165
units: mm[inch]
tolerance: ±0.5[±0.020]
4.75 0.187
(2 PLCS)
0.079 X 0.157
[2.01 X 3.99]
(2 PLCS)
3.51 0.138
(2 PLCS)
20.32 0.800
0.010 (2 PLCS)
Wire range: 22~14 AWG
DIN rail mounting kit available
(part# STK-DIN)
52.32 2.060
PIN CONNECTIONS
PIN
Single
Output
Dual
Output
1
GND
GND
2
Vin
Vin
3
CTRL
CTRL
4
Case
Case
5
NC
NC
6
+Vo
+Vo
7
NC
0V
8
0V
-Vo
1
2
3
4
5
6
7
8
1.00 0.039
(TYP)
5.21 0.205
(2 PLCS)
52.99 2.086
Front View
cui.com
12.19 0.480
33.02 1.300
0.010 (2 PLCS)
10.99 0.433
0.010 (2 PLCS)
19.05 0.750
4.01 0.158
0.010 (TYP)
34.93 1.375
0.010
34.01 1.339
0.010
9.16 0.361
0.010
Top View
R1.76 0.069
(2 PLCS)
Bottom View
5.31 0.209
(5 PLCS)
M3X4
(5 PLCS)
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PYB10-T & PYB10-U │ DESCRIPTION: DC-DC CONVERTER
date 11/25/2022 │ page 4 of 6
DERATING CURVES
EMC RECOMMENDED CIRCUIT
Figure 1
Table 1
Recommended external circuit components
Vin (Vdc)
FUSE
24
48
Choose according to input current
MOV
S14K35
S14K60
LDM1
56μH
56μH
TVS
SMCJ48A
SMCJ90A
C0
330μF/50V
330μF/100V
C1
1μF/50V
1μF/100V
LDM2
4.7μH
4.7μH
CY1
1 nF/2 KV
1 nF/2 KV
CY2
1 nF/2 KV
1 nF/2 KV
TEST CONFIGURATION
Table 2
External components
Figure 2
Note:
Lin
4.7μH
Cin
220μF, ESR < 1.0Ω
at 100 KHz
Input reflected-ripple current is measured with an inductor Lin and Capacitor Cin to simulate source impedance.
cui.com
Additional Resources:
Product Page
|
3D Model
CUI Inc │ SERIES: PYB10-T & PYB10-U │ DESCRIPTION: DC-DC CONVERTER
date 11/25/2022 │ page 5 of 6
APPLICATION NOTES
1. Recommended circuit
This series has been tested according to the following recommended testing circuit before leaving the factory. This series should be
tested under load (see Figure 3). If you want to further decrease the input/output ripple, you can increase the capacitance accordingly or choose capacitors with low ESR (see table 3). However, the capacitance of the output filter capacitor must be appropriate. If
the capacitance is too high, a startup problem might arise. For every channel of the output, to ensure safe and reliable operation, the
maximum capacitance must be less than the maximum capacitive load (see Table 4).
Figure 3
Single output
Dual output
Table 3
Table 4
Vin
(Vdc)
Cin
(µF)
Cout
(µF)
24
10~47
10
48
10~47
10
Single
Vout
(Vdc)
Max.
Capacitive
Load
(μF)
Dual
Vout
(Vdc)
3.3
2200
--
--
5
2200
5
680
12
4701
12
2203
15
3302
15
100
24
100
--
--
Notes:
Note:
1.
2.
3.
4.
Max.
Capacitive
Load4
(μF)
330 μF for 48Vin.
220 μF for 48Vin.
150 μF for 48Vin.
For each output.
1. Minimum load shouldn't be less than 5%, otherwise ripple may increase dramatically. Operation under minimum load will not damage the converter, however, they may
not meet all specifications listed.
2. Maximum capacitive load is tested at input voltage range and full load.
3. All specifications are measured at Ta=25°C, humidity