0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
QS30LD W/30

QS30LD W/30

  • 厂商:

    BANNER

  • 封装:

    -

  • 描述:

    RANGE: 400MM; INPUT: 10-30V DC

  • 数据手册
  • 价格&库存
QS30LD W/30 数据手册
WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Datasheet • • • • • • • • • Visible laser beam for diffuse sensing Available with Class 1 or long-range Class 2 laser Excellent optical performance throughout sensing range, even close up Easy-to-set Expert-style TEACH options1 including Static, Dynamic, and Single-Point programming plus manual adjustment for fine-tuning Easy-to-read operating status indicators, with 8-segment bargraph display Bipolar discrete outputs, PNP, and NPN Selectable 30 millisecond OFF-delay Models available with 2 m or 9 m (6.5 ft or 30 ft) cable or integral quickdisconnect Compact housing, mounting versatility – popular 30 mm threaded nose or side-mount WARNING: Not To Be Used for Personnel Protection Never use this device as a sensing device for personnel protection. Doing so could lead to serious injury or death. This device does not include the self-checking redundant circuitry necessary to allow its use in personnel safety applications. A sensor failure or malfunction can cause either an energized or de-energized sensor output condition. Models Models 2 Laser Class Range Class 1 400 mm (16 in) Approx. 1 mm at 400 mm (0.039 in at 16 in) Class 2 800 mm (32 in) Approx. 1 mm at 800 mm (0.039 in at 32 in) QS30LD QS30LDQ QS30LDL QS30LDLQ Spot Size at Focus Connection 2 m (6.5 ft) unterminated 5-wire cable Integral 5-pin M12/Euro-style male quick disconnect (QD) 2 m (6.5 ft) unterminated 5-wire cable Integral 5-pin M12/Euro-style male quick disconnect (QD) QS30 Laser Diffuse Overview The QS30 is an easy-to-use, high-performance laser sensor whose many configuration options make it suitable for demanding applications. It provides high-performance sensing in low-contrast applications at relatively long range. It features static, dynamic and single-point TEACH-mode programming, in addition to manual fine adjustment, remote programming and security lockout options. A SETUP mode also may be used to change the sensor’s output response. The sensor features two identically configured outputs, one each NPN and PNP. The sensor’s compact housing has a large, easy-to-see bar graph display plus bright LEDs for easy programming and status monitoring during operation. The sensor can be side-mounted, using its integral mounting holes, or front-mounted, via its 30 mm threaded barrel. Amber output conducting indicator Green power on indicator Programming buttons Bargraph display Switching threshold Setup status indicators: Delay Dark operate Light operate 1 U.S. Patent #5,808,296 2 To order the 9 m (30 ft) cable models, add the suffix “W/30” to the model number of any cabled sensor (for example, QS30LD W/30). A model with a QD connector requires a mating cable. Original Document 109027 Rev. E 15 December 2016 109027 WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Description of Laser Classes Class 1 Lasers Class 1 lasers are lasers that are safe under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Reference IEC 60825-1:2001, Section 8.2. Class 2 Lasers Class 2 lasers are lasers that emit visible radiation in the wavelength range from 400 nm to 700 nm, where eye protection is normally afforded by aversion responses, including the blink reflex. This reaction may be expected to provide adequate protection under reasonably foreseeable conditions of operation, including the use of optical instruments for intrabeam viewing. Reference IEC 60825-1:2001, Section 8.2. Class 2 Laser Safety Notes Low-power lasers are, by definition, incapable of causing eye injury within the duration of a blink (aversion response) of 0.25 seconds. They also must emit only visible wavelengths (400 to 700 nm). Therefore, an ocular hazard may exist only if individuals overcome their natural aversion to bright light and stare directly into the laser beam. For Safe Laser Use (Class 1 or Class 2): • • • • Do not stare at the laser. Do not point the laser at a person’s eye. Mount open laser beam paths either above or below eye level, where practical. Terminate the beam emitted by the laser product at the end of its useful path. CAUTION: Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure. Do not attempt to disassemble this sensor for repair. A defective unit must be returned to the manufacturer. Sensor Configuration Configure the sensor configuration by using the TEACH or Set options, plus Setup mode. After TEACH or Set have defined the sensing parameters, use the Setup mode to enable the delay or to change the Light Operate/Dark Operate status. Use the Manual Adjust to fine-tune the thresholds. Two push buttons, Dynamic (+) and Static (-), or the remote wire, may be used to access and set the parameters. Sensor • • • • configuration options include: Two-Point Static TEACH: a single switching threshold, determined by two taught conditions. Dynamic (on-the-fly) TEACH: a single switching threshold, determined by multiple sampled conditions. Window Set: a sensing window, centered on a single sensing condition. Light Set and Dark Set: a single switching threshold, offset from a single sensing condition. Remote Configuration The remote function can be used to configure the sensor remotely or to disable the push button for security. Connect the gray wire of the sensor to ground (0 V dc), with a remote programming switch connected between them. Pulse the remote line according to the diagrams in the configuration procedures. The length of the individual programming pulses is equal to the value T where: 0.04 seconds ≤ “T” ≤ 0.8 seconds Returning to Run Mode Configuration modes each may be exited either after the 60-second time-out or by exiting the process in one of the two following ways: • 2 In static TEACH or SET modes, press and hold the Static (-) button (or hold the remote line) for 2 seconds. The sensor returns to Run mode without saving any new settings. www.bannerengineering.com - Tel: +1-763-544-3164 P/N 109027 Rev. E WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor • In SETUP mode, press and hold both the Static (-) and Dynamic (+) buttons (or hold the remote line) for 2 seconds. The sensor returns to Run mode and saves the current setting. Two-Point Static TEACH (Threshold) • • • Sets a single switching threshold (switching point) Threshold position is adjustable using “+” and “-” buttons (Manual Adjust). Recommended for applications where two conditions can be presented by the user. 2nd Taught Condition Sensor positions threshold midway between taught conditions Two-Point TEACH is the traditional configuration method. The sensor locates a single sensing threshold (switch point) midway between the two taught conditions, with the Output ON condition on one side and the Output OFF condition on the other. The first condition taught is the ON condition. The Output ON and OFF conditions can be reversed by changing Light/Dark Operate status in Setup Mode. 1st Taught Condition Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) Two-Point TEACH and Manual Adjust Using Manual Adjust with Two-Point TEACH moves the switching threshold position. The lighted LED on the bar graph moves to exhibit the received signal, relative to the threshold. Bargraph LED (Following TEACH) Relative Signal Difference/Recommendation 6 to 8 Excellent: Very stable operation. 4 to 5 Good: Minor variables will not affect sensing reliability. 2 to 3 Low: Minor sensing variables may affect sensing reliability. 1 Unreliable: Consider an alternate sensing scheme. Push Button Remote Line 0.04 seconds ≤ “Click” ≤ 0.8 seconds 0.04 seconds ≤ T ≤ 0.8 seconds Result Access TEACH Mode Press and hold Static (-) button for more than 2 seconds No action required; sensor is ready for 1st TEACH condition. Power LED: OFF Output LED: ON Bar graph: #5 and 6 flash TEACH Output ON Condition Present Output ON condition and click the Static (-) button Present Output ON condition and single-pulse the remote line Power LED: OFF Output LED: OFF Bar graph: #5 and 6 flash TEACH Accepted Power LED: ON TEACH Output OFF Condition Present Output OFF condition and click the Static (-) button Present Output OFF condition and single-pulse the remote line Bar graph: One LED flashes to show relative contrast (good signal difference shown; see table above) Sensor returns to RUN mode TEACH Unacceptable Power LED: OFF Bar graph: #1, 3 and 6, 8 flash to show failure Sensor returns to “TEACH Output ON Condition” P/N 109027 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 3 WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Dynamic TEACH and Adaptive Thresholds • • • • Teach on-the-fly Sets a single switching threshold (switching point) Threshold position is adjustable using “+” and “-” buttons (Manual Adjust) Recommended for applications where a machine or process may not be stopped for teaching. Dynamic TEACH is a variation of two-point TEACH. It programs the sensor during actual machine run conditions, taking multiple samples of the light and dark conditions and automatically setting the threshold at the optimum level. Dynamic TEACH activates the sensor’s adaptive threshold system, which continuously tracks minimum and maximum signal levels, and automatically maintains centering of the threshold between the light and dark conditions. The adaptive threshold system remains in effect during Run mode. The adaptive routine saves to non-volatile memory at least once per hour. Darkest Taught Condition Lightest Taught Condition Sensor positions threshold midway between taught conditions Output OFF Darkest (no signal) Output ON Position adjusted by Manual Adjust Most Light (saturated signal) When Dynamic TEACH mode is used, the output ON state (Light or Dark Operate) will remain as it was last programmed. To change the output ON state, use Setup Mode. The sensing threshold may be adjusted (fine-tuned) whenever the sensor is in RUN mode by clicking the “+” and “-” buttons. However, when a manual adjustment is made, the adaptive threshold system is disabled (cancelled). Bar Graph LED (Following TEACH) Relative Signal Difference/Recommendation 6 to 8 Excellent: Very stable operation. 4 to 5 Good: Minor variables will not affect sensing reliability. 2 to 3 Low: Minor sensing variables may affect sensing reliability. 1 Unreliable: Consider an alternate sensing scheme. Push Button Remote Line Result Access Dynamic TEACH Mode Press and hold Dynamic (+) push button for more than 2 seconds Hold the remote line low (to ground) for more than 2 seconds Power LED: OFF Output LED: OFF Bar graph: #7 and 8 flash TEACH Sensing Conditions Continue to hold push button (+) and present the Output ON and OFF conditions Continue to hold remote line low (to ground) and present the Output ON and OFF conditions Power LED: OFF Output LED: OFF Bar graph: #7 and 8 flash TEACH Accepted Power LED: ON Bar graph: One LED flashes to show relative contrast (good signal difference shown; see table above) Return to Run Mode Release push button (+) Release the remote line/ switch Sensor returns to RUN mode with new settings TEACH Unacceptable Power LED: OFF Bar graph: #1, 3 and 6, 8 flash to show failure Sensor returns to RUN mode without changing settings 4 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 109027 Rev. E WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Single-Point Window Set • • • Sets a single ON condition All other conditions (lighter or darker) result in OFF output Sensing window size (sensitivity) is adjustable using “+” and “-” buttons (Manual Adjust) Single-Point TEACH is most useful when a product may not always appear in the same place or when other signals may appear. Single-Point TEACH programs a sensing window, with the Output ON condition inside the window, and the Output OFF conditions outside the window. Output ON and OFF conditions can be reversed by changing Light/Dark Operate status in SETUP mode. Sensing window size adjusted by Manual Adjust Output OFF Darkest (no signal) Output ON Output OFF Single taught point Most Light (saturated signal) Single-Point TEACH programming may be accomplished only using Static TEACH. The sensor learns a single sensing condition, and adds switching thresholds above and below the taught condition to create a sensing window. Single-Point Window Set and Manual Adjust Using Manual Adjust with Single-Point Window Set expands or contracts the size of the window. The lighted LEDs on the light bar separate to a greater or lesser extent to exhibit the relative sensing window size. Push Button Remote Line Result 0.04 seconds ≤ “Click” ≤ 0.8 seconds 0.04 seconds ≤ T ≤ 0.8 seconds Access Set Mode Press and hold Static (-) push button for more than 2 seconds Present the output ON condition and singlepulse the remote line Power LED: OFF Output LED: ON (Push Button) Output LED: OFF (Remote) Bar graph: #5 and 6 flash Teach Set Point (Output ON) Condition Present the output ON condition and double-click the Static (-) push button Double-pulse the remote line TEACH Accepted Power LED: ON Bar graph: #3, 6 flash together to show single-point TEACH Sensor returns to RUN mode with new settings TEACH Unacceptable Power LED: OFF Bar graph: #1, 3 and 6, 8 flash to show failure, then 5 and 6 flash Sensor waits for valid TEACH condition Single-Point Light Set • • • • Sets a threshold slightly below the taught condition. Any condition darker than the threshold condition causes the output to change state. Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust). Recommended for applications where only one condition is known, for example a stable light background with varying darker targets. A single sensing condition is presented, and the sensor positions a threshold below the presented condition. When a condition darker than the threshold is sensed, the output either turns ON or OFF, depending on the Light/Dark Operate setting (see Setup Mode on page 7). Threshold position adjusted by Manual Adjust Sensor positions threshold slightly below the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Light Set and Light/Dark Operate Selection In Light Operate mode, Light Set teaches the Output ON condition. In Dark Operate mode, Light Set teaches the Output OFF condition. P/N 109027 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 5 WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Push Button Remote Line 0.04 seconds ≤ “Click” ≤ 0.8 seconds 0.04 seconds ≤ T ≤ 0.8 seconds Access Set Mode Press and hold Static (-) push button for more than 2 seconds Single-pulse the remote line Set Sensing Condition Present the sensing condition Present the sensing and click the Static (-) push condition and four-pulse button four times the remote line Result Power LED: OFF Output LED: ON (Push Button) Output LED: OFF (Remote) Bar graph: #5 and 6 alternately flash Threshold Condition Accepted Power LED: ON Bar graph: Indicators #5–8 flash together to show that the threshold condition is accepted Sensor returns to RUN mode with new settings Threshold Condition Unacceptable Power LED: OFF Bar graph: #1, 3 and 5, 7 alternately flash to show failure Sensor returns to “SET Sensing Condition” Single-Point Dark Set • • • • Sets a threshold slightly above the taught condition. Any condition lighter than the threshold condition causes the output to change state. Threshold position is adjustable using the “+” and “-” buttons (Manual Adjust). Recommended for applications where only one condition is known, for example a stable dark background with varying lighter targets. A single sensing condition is presented, and the sensor positions a threshold above the taught condition. When a condition lighter than the threshold is sensed, the output either turns ON or OFF, depending on the Light/Dark Operate setting (see Setup Mode on page 7). Threshold position adjusted by Manual Adjust Sensor positions threshold above the presented condition Output OFF Darkest (no signal) Output ON Condition Presented Most Light (saturated signal) Dark Set and Light/Dark Operate Selection In Light Operate mode, Dark Set teaches the Output OFF condition. In Dark Operate mode, Dark Set teaches the Output ON condition. Access Set Mode Set Sensing Condition 6 Push Button Remote Line 0.04 seconds ≤ “Click” ≤ 0.8 seconds 0.04 seconds ≤ T ≤ 0.8 seconds Press and hold the Static (-) push button for more than 2 seconds Single-pulse remote line Present the sensing condition and click the Static (-) push button five times Present the sensing condition and five-pulse the remote line Result Power LED: OFF Output LED: ON (Push Button) Output LED: OFF (Remote) Bar graph: #5 and 6 alternately flash Threshold Condition Accepted Power LED: ON Bar graph: Indicators #1–4 flash together to show that the threshold condition is accepted Sensor returns to Run mode with new settings Threshold Condition Unacceptable Power LED: OFF Bar graph: #1, 3 and 5, 7 alternately flash to show failure Sensor returns to “Set Sensing Condition” www.bannerengineering.com - Tel: +1-763-544-3164 P/N 109027 Rev. E WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Setup Mode SETUP mode is used to change sensor output response for: • Light or dark operate • 30-millisecond pulse stretcher (OFF delay), if required. The status LEDs, active only during Setup mode, indicate the output response configuration when the sensor is in Run mode. Four combinations are possible: Light Operate, No Delay Dark Operate, No Delay Dark Operate, 30 ms Delay Light Operate, 30 ms Delay Press and hold both buttons to access Setup mode Setup mode status indicators To access SETUP mode and change the output response settings: 1. Press and hold BOTH push buttons (or double-pulse Remote line) until the green LED indicator turns OFF. 2. Click EITHER push button (or pulse Remote line) to toggle through the four possible setting combinations. 3. Press and hold both push buttons (or hold Remote line) until the green LED indicator turns ON, indicating return to RUN mode. NOTE: • If Setup mode programming is interrupted and remains inactive for 60 seconds, the sensor returns to Run mode with the most recent settings (i.e., exits and saves current selection). • Setup mode operates in the “background”, while the outputs are active. Manual Adjust Manual adjust is used during Run mode via the push buttons only. Its behavior depends on whether a switching threshold or sensing window is used. Switching Threshold (Static TEACH, Dynamic TEACH, Light Set, and Dark Set): • • Fine-tunes sensing threshold set-point value Press “+” to increase; press “-” to decrease Sensing Window (Window Set): • • Adjusts sensing window size Press “+” to increase; press “-” to decrease The lighted bar graph LEDs move to reflect the increase or decrease. Push Button Disable In addition to its programming function, Remote Programming may be used to disable the push buttons for security. Disabling the push buttons prevents undesired tampering with the programming settings. Connect the gray wire of the sensor as described and four-pulse to enable or disable the push buttons. T T T T T T T Reset to Factory Defaults To reset the sensor back to its factory default settings, eight-pulse the remote input wire. T T T T T T T T T T T T T T T Where T is: 0.04 seconds ≤ T ≤ 0.8 seconds. P/N 109027 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 7 WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Specifications Supply Voltage 10 to 30 V dc (10% maximum ripple at 10% duty cycle) at 35 mA maximum current, exclusive of load Sensing Beam Class 1 Laser: Visible red, 650 nm Class 2 Laser: Visible red, 658 nm Supply Protection Circuitry Protected against reverse polarity and transient over voltages Beam Size at Aperture Approximately 2 mm Laser Classification Class 1 or Class 2, depending on model Delay at Power Up 1 second maximum; outputs do not conduct during this time Output Configuration Bipolar: 1 current sourcing (PNP) and 1 current sinking (NPN) Rating: 150 mA maximum load OFF-state leakage current: < 10 μA at 30 V dc ON-state saturation voltage: NPN: < 1.0 V at 150 mA load; PNP: < 2.0 V at 150 mA load Repeatability 70 microseconds Output Protection Circuitry Protected against output short-circuit and continuous overload Output Response Time 500 microseconds Indicators 8-segment red bar graph: Signal strength relative to switch-point Green LED: Power ON Amber LED: Output conducting Adjustments 2 push buttons and remote wire Expert Teach programming (two-point static, dynamic, window set, light set, dark set) Manually adjust (+/–) thresholds (from buttons only) LO/DO and OFF-delay configuration options Push-button lockout (from remote wire only) Reset to factory defaults (from remote wire only) Factory Default Settings Maximum gain Single threshold set at midpoint range Light operate No delays Construction ABS housing; acrylic lens cover Connections 5-conductor 2 m (6.5 ft) PVC cable, 9 m (30 ft) PVC cable, or 5-pin integral M12/Euro-style male quick-disconnect fitting Required Overcurrent Protection Environmental Rating IEC IP67; NEMA 6 WARNING: Electrical connections must be made by qualified personnel in accordance with local and national electrical codes and regulations. Operating Conditions –10 °C to +50 °C (+14 °F to 122 °F) 95% at +50 °C maximum relative humidity (non-condensing) Vibration and Mechanical Shock All models meet Mil. Std. 202F requirements. Method 201A (Vibration: 10 to 60Hz max. double amplitude 0.06 in, maximum acceleration 10G). Also meets IEC 947-5-2 requirements: 30G, 11 ms duration, half sine wave. Certifications 8 Overcurrent protection is required to be provided by end product application per the supplied table. Overcurrent protection may be provided with external fusing or via Current Limiting, Class 2 Power Supply. Supply wiring leads < 24 AWG shall not be spliced. For additional product support, go to www.bannerengineering.com. Supply Wiring (AWG) Required Overcurrent Protection (Amps) 20 5.0 22 3.0 24 2.0 26 1.0 28 0.8 30 0.5 www.bannerengineering.com - Tel: +1-763-544-3164 P/N 109027 Rev. E WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Dimensions Cabled Models QD Models 35.0 mm (1.38") 22.0 mm (0.87") 32.5 mm (1.28") 1.3 mm (0.05") 12.5 mm (0.49") 3.5 mm (0.14") 8 7 6 5.0 mm (0.20") 44.0 mm (1.73") 33.0 mm (1.30") 5 4 3 2 1 M30 x 1.5 Thread max. torque 6 Nm (53 in lbs) with included 30 mm mounting nut 2 x ø3.3 mm (0.125") max. torque 0.7 Nm (6 in lbs) 13.0 mm (0.51") Hardware Included: (2) M3 × 0.5 × 28 stainless steel machine screws, nuts, and washers Performance Curves Class 1 Laser Models 6 mm Class 2 Laser Models 0.24 in QS30 4 mm Diffuse Mode 2 mm 0 6 mm 0.16 in 4 mm 0.08 in 2 mm 0 0.24 in QS30 0.16 in Diffuse Mode 0.08 in 0 0 2 mm 0.08 in 2 mm 0.08 in 4 mm 0.16 in 4 mm 0.16 in 6 mm 0.24 in 6 mm 0.24 in 0 100 mm 200 mm 300 mm 400 mm 4.0 in 8.0 in 12.0 in 16.0 in 0 200 mm 8.0 in DISTANCE P/N 109027 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 400mm 16.0 in 600 mm 800 mm 24.0 in 32.0 in DISTANCE 9 WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Class 1 Laser Models Class 2 Laser Models 1000 1000 QS30 Diffuse Mode Laser 100 EXCESS GAIN EXCESS GAIN QS30 10 1 1 mm .04 in 10 mm .4 in 100 mm 4 in 1000 mm 40 in Diffuse Mode Laser 100 10 1 1 mm .04 in 10 mm .4 in DISTANCE 1000 mm 40 in 100 mm 4 in DISTANCE Wiring Diagrams QD Models Cabled Models brown blue white black gray brown + 10-30 V dc – Load Load blue white 150 mA maximum load Load black Load gray Remote TEACH + 10-30 V dc – 150 mA maximum load Remote TEACH Accessories Quick-Disconnect Cables 5-Pin Threaded M12/Euro-Style Cordsets—Single Ended Model MQDC1-501.5 Length Style Dimensions MQDC1-506 1.83 m (6 ft) MQDC1-515 4.57 m (15 ft) 2 1 44 Typ. 3 4 Straight MQDC1-530 10 Pinout (Female) 0.50 m (1.5 ft) 9.14 m (30 ft) M12 x 1 ø 14.5 www.bannerengineering.com - Tel: +1-763-544-3164 5 1 = Brown 2 = White 3 = Blue 4 = Black 5 = Gray P/N 109027 Rev. E WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor 5-Pin Threaded M12/Euro-Style Cordsets—Single Ended Model Length Style MQDC1-506RA 1.83 m (6 ft) MQDC1-515RA 4.57 m (15 ft) Dimensions 32 Typ. [1.26"] 30 Typ. [1.18"] Right-Angle MQDC1-530RA Pinout (Female) 9.14 m (30 ft) M12 x 1 ø 14.5 [0.57"] Brackets SMB30SC • Swivel bracket with 30 mm mounting hole for sensor • Black reinforced thermoplastic polyester • Stainless steel mounting and swivel locking hardware included 67 B 58 29 SMBQS30L • Right-angle bracket for cable sensor models • Clearance for M4 (#8) hardware • ± 12° tilt adjustment • 14-ga. stainless steel A Hole center spacing: A=ø 50.8 Hole size: A=ø 7.0, B=ø 30.0 Hole center spacing: A to B=35.0 Hole size: A=ø 4.3, B=ø 4.25x16.3 SMBQS30LT • Tall right-angle bracket for QD models • ± 8° tilt adjustment • 14-ga. stainless steel SMBQS30Y • Heavy-duty die-cast bracket • M18 vertical mount option • ± 8° tilt adjustment with cabled units • Includes nuts and lock washer Hole center spacing: A to B=35.0 Hole size: A=ø 4.3, B=ø 4.25x16.3 Hole size: A=ø 15.3 SMB30MM • 12-ga. stainless steel bracket with curved mounting slots for versatile orientation • Clearance for M6 (¼ in) hardware • Mounting hole for 30 mm sensor 57 70 C 57 Hole center spacing: A = 51, A to B = 25.4 Hole size: A = 42.6 x 7, B = ø 6.4, C = ø 30.1 B A SMB30A • Right-angle bracket with curved slot for versatile orientation • Clearance for M6 (¼ in) hardware • Mounting hole for 30 mm sensor • 12-ga. stainless steel 45 C 61 B A 69 Hole center spacing: A to B=40 Hole size: A=ø 6.3, B= 27.1 x 6.3, C=ø 30.5 All measurements are listed in millimeters, unless noted otherwise. P/N 109027 Rev. E www.bannerengineering.com - Tel: +1-763-544-3164 11 WORLD-BEAM® QS30 Diffuse-Mode Laser Sensor Banner Engineering Corp. Limited Warranty Banner Engineering Corp. warrants its products to be free from defects in material and workmanship for one year following the date of shipment. Banner Engineering Corp. will repair or replace, free of charge, any product of its manufacture which, at the time it is returned to the factory, is found to have been defective during the warranty period. This warranty does not cover damage or liability for misuse, abuse, or the improper application or installation of the Banner product. THIS LIMITED WARRANTY IS EXCLUSIVE AND IN LIEU OF ALL OTHER WARRANTIES WHETHER EXPRESS OR IMPLIED (INCLUDING, WITHOUT LIMITATION, ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE), AND WHETHER ARISING UNDER COURSE OF PERFORMANCE, COURSE OF DEALING OR TRADE USAGE. This Warranty is exclusive and limited to repair or, at the discretion of Banner Engineering Corp., replacement. IN NO EVENT SHALL BANNER ENGINEERING CORP. BE LIABLE TO BUYER OR ANY OTHER PERSON OR ENTITY FOR ANY EXTRA COSTS, EXPENSES, LOSSES, LOSS OF PROFITS, OR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES RESULTING FROM ANY PRODUCT DEFECT OR FROM THE USE OR INABILITY TO USE THE PRODUCT, WHETHER ARISING IN CONTRACT OR WARRANTY, STATUTE, TORT, STRICT LIABILITY, NEGLIGENCE, OR OTHERWISE. Banner Engineering Corp. reserves the right to change, modify or improve the design of the product without assuming any obligations or liabilities relating to any product previously manufactured by Banner Engineering Corp. Any misuse, abuse, or improper application or installation of this product or use of the product for personal protection applications when the product is identified as not intended for such purposes will void the product warranty. Any modifications to this product without prior express approval by Banner Engineering Corp will void the product warranties. All specifications published in this document are subject to change; Banner reserves the right to modify product specifications or update documentation at any time. Specifications and product information in English supersede that which is provided in any other language. For the most recent version of any documentation, refer to: www.bannerengineering.com. © Banner Engineering Corp. All rights reserved
QS30LD W/30 价格&库存

很抱歉,暂时无法提供与“QS30LD W/30”相匹配的价格&库存,您可以联系我们找货

免费人工找货