  • 厂商:

    B&K

  • 封装:

    -

  • 描述:

    200MHZFREQUENCYCOUNTER

  • 数据手册
  • 价格&库存
1803D 数据手册
INSTRUCTION MANUAL MANUAL DE INSTRUCCIONES Model 1803D Modelo 1803D 200 MHz FREQUENCY COUNTER 200 MHz CONTADOR DE FRECUENCIA TEST INSTRUMENT SAFETY WARNING Normal use of test equipment exposes you to a certain amount of danger from electrical shock because testing must sometimes b e performed where exposed high voltage is present. An electrical shock causing 10 milliamps of current to pass through the hear t will stop most human heartbeats. Voltage as low as 35 volts dc or ac rms should be considered dangerous and hazardous since it can prod uce a lethal current under certain conditions. Higher voltages are even more dangerous. Your normal work habits should incl ude all accepted practices to prevent contact with exposed high voltage, and to steer current away from your heart in case of accidental conta ct with a high voltage. Observe the following safety precautions: 1. There is little danger of electrical shock from the dc output of this power supply because it can source 60 Vdc. There are several other possible test conditions using this power supply that can create a high voltage shock hazard: a. If the equipment under test is the “hot chassis” type, a serious shock hazard exists unless the equipment is unplugged (just turning off the equipment does not remove the hazard), or an isolation transformer is used. b. If the equipment under test is “powered up” (and that equipment uses high voltage in any of its circuits), the power supply outputs may be floated to the potential at the point of connection. Remember that high voltage may appear at unexpected points in defective equipment. Do not float the power supply output to more than 100 volts peak with respect to chassis or earth ground. c. If the equipment under test is “off” (and that equipment uses high voltage in any of its circuits under normal operation), di scharge high-voltage capacitors before making connections or tests. Some circuits retai n high voltage long after the equipment is turned off. 2. Use only a polarized 3-wire ac outlet. This assures that the power supply chassis, case, and ground terminal are connected to a good earth ground and reduces danger from electrical shock. 3. Don’t expose high voltage needlessly. Remove housings and covers only when necessary. Turn off equipment while making test connections in high-voltage circuits. Discharge high-voltage capacitors after removing power. (continued on inside back cover) TABLE OF CONTENTS page page TEST INSTRUMENT SAFETY ----------inside front cover INSTRUMENT REPAIR SERVICE......................... 10 SPECIFICATIONS .............................................................. 4 LIMITED ONE-YEAR WARRANTY ...................... 11 CONTROLS AND INDICATORS -------------------------- 6 SPANISH MANUAL ............................................. 16 OPERATING INSTRUCTIONS ....................................... 8 SPECIFICATIONS MODES/FEATURES Gate Times Displayz INPUT CHARACTERISTICS 1.0 sec and 0.1 sec gates. 7 digits IMPEDANCE Connector Coupling Sinewave Sensitivity FREQUENCY CHARACTERISTICS Range: HF 10Hz to 25MHz VHF 10MHz TO 200MHz Maximum Input HF 1MΩ VHF 50Ω BNC D6 50mVrms, 10Hz to 200MHz 3V Accuracy: 1.0 Sec Gate 0.1 Sec Gate ± Time base accuracy, ± 1 count ± Time base accuracy, ± 2 counts TIME BASE CHARACTERISTICS Type Crystal Oscillator Frequency 5.24288MHz Stability ±10ppm Temperature Stability
1803D 价格&库存

很抱歉,暂时无法提供与“1803D”相匹配的价格&库存,您可以联系我们找货

免费人工找货