0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
SLR5.100

SLR5.100

  • 厂商:

    PULS

  • 封装:

    -

  • 描述:

    AC/DCCONVERTER24V120W

  • 数据手册
  • 价格&库存
SLR5.100 数据手册
Redundancy with boost CB scheme SLR5.100 IEC60950 Data sheet UL508 LISTED IND. CONT. EQ. 18 WM, 60°C • • • • • The Redundant Variant Input: AC 230V/115V, DC 210-375V Output: 24V/5A High overload current, no switch-off Quasi-Wide-Range Input N+1 redundancy, RDY relay contact Input Input voltage AC100-120/220-240 V (switchable), 47-63 Hz (85-132 VAC / 176-264 VAC, 210-375 VDC, see also „Output: Continuous Loading“) < 2.6 A (switch in 115V position) < 1.4 A (switch in 230V position) • DCin at open output typ. 5 mA (preserves battery sources) Inrush current EMC and Low Volt. Directive Output Quasi-Wide-Range Input: With the switch in the 230V position the power supply unit operates at low and moderate loads (until 3 A) at any input voltage between 95 and 264 V AC. Note: At DC input, always leave the switch in the 230V position. Input current UL60950 E137006 CUL/CSA-C22.2 No 950-M90 typ. < 15 A at 264 V AC and cold start To be fused with a 10A, B-type 'circuit-breaker' switch based on the usual thermomagn. overload sensing principle (used anyway to fuse the input lines). In addition, the unit contains an internal fuse (not accessible). Rated output voltage 24 V DC For balanced current sharing during parallel operation: Soft characteristic (25.2 V DC ±2% at no-load, 24 V DC ±0.5% at nominal load, almost linear characteristic curve) Output noise suppression Radiated EMI values below EN50081-1, even when using long, unscreened output cables. Ambient temperature range Tamb Operation: -10°C...+70°C (>60°C: Derating) Storage: -25°C...+85°C Continuous loading Switch AC/DCin Iout (at Tamb= -10°C...+60°C, 230V 176-264 V ACin 5 A / 6 A * convection cooling), see 95-176 V ACin 3 A also diagram overleaf. 210-375 V DCin 5 A / 6 A * For start at Tamb< 0°C and 150-210 V DCin 3 A low input voltage, please contact PULS. 100-150 V DCin 2 A Output is protected 115V 85-132 V ACin 5 A / 6 A * against short circuit, * short-term 6 A (< 1 min), at 45°C or forced cooling open circuit and overload even continuous Harmonic current emissions acc. to EN 61000-3-2 Transient handling Transient resistance acc. to VDE 0160 / W2 (750 V / 1.3 ms), for all load conditions. Derating typ. 3 W/K Voltage regulation better than 2% Vout overall Hold-up time > 37 ms at 196 VAC, 24 V / 5 A (see diagram overleaf) Ripple / Noise < 30 mVPP, (20 MHz bandw., 50 !"measurem.) Efficiency, Reliability etc.* Efficiency typ. 89 % (230 VAC, 24 V / 5 A) Losses typ. 14.8 W MTBF 480.000 h acc. to Siemensnorm SN 29500 (24 V/5 A, 230 VAC, Tamb = +40 °C) (230 VAC, 24 V / 5 A) Life cycle (electrolytics) The unit exclusively uses longlife electrolytics, specified for +105°C (cf. ’The SilverLine’, p.2). Construction / Mechanics* Housing dimensions and Weight 64 mm x 124 mm x 102 mm (+ DIN rail) • WxHxD above/below 25 mm recommended • Free space for left/right 15 mm recommended ventilation 620 g • Weight Design advantages: • Input and output pluggable by means of Combicon® plug connector. • Ensure strain relief of the plug connectors when installing the unit. • Input and output are strictly apart from each other and so cannot be mixed up (input below, output above). slr5e100 / 040107 (at Tamb=+60°C...+70°C) Overvolt. protection typ. 29 V Parallel operation yes, current sharing via soft characteristic (see diagram) Front panel indicator Green LED RDY relay contact • Type • closes • opens • Electrical isolation • Contact rating normally open contact when output voltage > 22.1V ±4% when output voltage < 19.8V ±4% 500V DC to output voltage 1A at 28V DC * For further information see data sheets „The SilverLine“, „SilverLine Family Branches“ and mechanics data sheet Order information Order number Description SLR5.100 SL5.100 SLS5.100 SLZ01 N+1 redundancy* Basic version without redundancy* Safety Cover* Screw mounting set, two needed per unit 1/2 Data sheet Start / Overload Behaviour Output characteristic (min.) 28 typ. 0.1 s Rise time ca. 5-20 ms, depending on load Overload Behaviour • Special PULS Overload Design (see right diagram) • 20% power boost – no disconnection, no hiccup if overloaded – high overload current (up to 1.9 INom), Vout is gradually reduced with increasing current. – 6A short-term, at 45°C or forced cooling even continuous Advantages: • High short-circuit current, giving large ’start-up window’: unit starts reliably even with awkward loads (DC-DC converters, motors). • No ’sticking’ such as can occur with fold-back characteristics • Secondary fuses operate reliably Tamb = 60°C / 45°C / 25°C / 0 °C 24 20 Output voltage Vout [V] Start-up delay 16 12 8 4 0 0 5 10 15 Output current Iout [A] Further information Output Current over Input Voltage (min.) Further information, especially about • EMC • Connections • Safety, Approvals • Mechanics and Mounting see page 2 of „The SilverLine“ data sheet. 6 DCin 4 Output current Iout [A] 2 For detailed dimensions see SilverLine mechanics data sheet SLR2.5/ 5/ 10 210 100 200 6 switch at 115V 400 ACin 4 Power wiring 375 300 Input voltage DCin [V] switch at 230V 2 GND +24V 95 85 100 132 176 200 264 300 400 Input voltage ACin [V] + – Hold-up time (min.) 100 SLR5.100 90 Iout=3 A 80 Iout=2,0 A N L Hold-up time [ms] 70 60 50 Iout=5 A 40 30 20 DCin 10 0 90 130 170 210 250 Input voltage VDCin [V] 290 330 + – 100 90 Iout=3 A switch pos. 115V 80 N L 70 Hold-up time [ms] SLR5.100 Iout=5 A 60 Iout=2,0 A Iout=3 A switch pos. 230V 50 Iout=5 A 40 30 20 ACin 10 0 90 120 150 180 Input voltage VACin [V] 210 240 Unless otherwise stated, specifications are valid for AC 230V input voltage, +25°C ambient temperature, and 5 min. run-in time. They are subject to change without prior notice. Your partner in power supply: European Power Supply Manufacturers Association Bayerns Best 50 Czech 100 Best EuropeÕs 500 PULS GmbH Arabellastraße 15 D-81925 München Tel.: +49 89 9278-0 Fax: +49 89 9278-199 www.puls-power.com 2/2 slr5e100 / 040107 Mechanics Data sheet SLR2.5 /SLR5 / SLR10 • Innovative DIN-Rail mount, unit holds even at vibration or lateral pressure • Clearly arranged and user oriented • Large, robust plug connectors • Sealed metal housing • Fine ventilating grid Side view SLR2.5 Front view SLR2.5 Bottom view SLR2.5 102 Construction / Mechanics Connections Housing dimensions and Weight Unit W x H x D [mm] weight • SLR2.5 49 x 124 x 102 470 g • SLR5.100 64 x 124 x 102 620 g • SLR10.10 120 x 124 x 102 980 g Connections • Input • Output • Current handling capacity • Grid stable plug connectors, connector size range: 0.2 – 2.5 mm2 0.2 – 2.5 mm2 , SLR10: 0.2 – 4 mm2 Design advantages: • All connection blocks are easy to reach as mounted at the the front panel. • Input and output are strictly apart from each other and so cannot be mixed up Free space for ventilation left above/below right 0 mm 25 mm each 10 mm 15 mm 25 mm each 15 mm 15 mm 25 mm each 15 mm Overall depth = depth value as mentioned + DIN rail depth Robust metal housing with fine ventilat. grid ( 3,5 mm, IP20), to keep out small parts (e.g. screws) Mounting on DIN-Rail (TS35/7.5 or TS35/15, 1...1.5 mm thick), thus • Simple snap-on system • Sits safely and firmly on the DIN-Rail • No tools required to remove or backplane-mounted (two optional screw mounting sets SLZ01 required) slredrw1 / 040114 12 A each (SLR10: 20 A each) 7.62 mm (input) / 5.08 mm (output) distance between adjacent connectors SLR10: 7.62 mm (output) Order information Order number Description SLR2.5: 24V/2.5A SLR5.100: 24V/5A SLR10.100: 24V/10A SLZ01 Screw mounting set, two needed per unit 1/2 Data sheet Side view and front view SLR5.100 Bottom view SLR5.100 Side view and front view SLR10.100 Bottom view SLR10.100 his ’mechanics data sheet’ exclusively deals with the mechanical properties of the product. For further information (especially concerning electrical properties), please refer to the generic data sheet of the SLR2.5, SLR5.100 and SLR10.100 and to the basic data sheet „The SilverLine“ dealing with common features of all SilverLine units. This data sheet is subject to change without prior notice. Your partner in power supply: European Power Supply Manufacturers Association Bayerns Best 50 Czech 100 Best EuropeÕs 500 PULS GmbH Arabellastraße 15 D-81925 München Tel.: +49 89 9278-0 Fax: +49 89 9278-199 www.puls-power.com 2/2 slredrw1 / 040114
SLR5.100 价格&库存

很抱歉,暂时无法提供与“SLR5.100”相匹配的价格&库存,您可以联系我们找货

免费人工找货