0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
153283367A212

153283367A212

  • 厂商:

    WURTHELEKTRONIKIBE

  • 封装:

    LED-2P_3.5X2.8MM_SM

  • 描述:

    153283367A212

  • 数据手册
  • 价格&库存
153283367A212 数据手册
Dimensions: [mm] Recommended Land Pattern: [mm] Absolute Maximum Ratings (Ambient Temperature 25°C): Properties 3,5 ±0,2 2,0 ±0,2 2 2 2,1 1 2,1 ±0,2 1 1,8 ±0,2 0,95 ±0,2 PDiss Peak Forward Current IF Peak duty/ 10 @ 1 kHz mA ESD Threshold/ Human Body Model VESD HBM 2000 V TJ 90 °C 0,7 ±0,2 AlInGaN Emitting Color Ultraviolet-A Lens Type Waterclear Lens Color Waterclear Plastic Housing Color White General Information: + 2 Protection device -40 up to +65 °C Storage Conditions (in original packaging) < 40 °C ; < 90 % RH Storage Conditions (for single parts) -40 up to +85 °C Moisture Sensitivity Level (MSL) 3  UV LEDs emit high intensity UV light. not look directly into the UV light during operation. This can be harmful to your eyes and skin.  Wear protective eyewear to avoid exposure to UV light.  Do not view directly with optical instruments.  Keep out of reach of children. Avoid direct eye and skin exposure to UV light! CAUTION – UV 1 2,8 ±0,2 mA 60 Operating Temperature 2 W 90 IF Chip Technology Schematic: 1 Unit 0.24 Optical Properties: 1,1 3,7 Polarity Mark Value Continuous Forward Current Junction Temperature 2,1 3,2 ±0,2 Test conditions Power Dissipation  Do CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE DoK 001.000 2022-02-21 DIN ISO 2768-1m PROJECTION METHOD DESCRIPTION Würth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions Max-Eyth-Str. 1 74638 Waldenburg Germany Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos@we-online.com WL-SUTW SMT Ultraviolet TopLED Waterclear ORDER CODE 153283367A212 SIZE/TYPE BUSINESS UNIT STATUS PAGE 2835 eiPal Valid 1/9 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Electrical & Optical Properties: Properties Test conditions Viewing Angle: Value min. typ. max. Unit λPeak 60 mA Radiant Flux Φe 60 mA 30 50 90 Forward Voltage VF 60 mA 2.8 3.6 4 Spectral Bandwidth Δλ 60 mA 13 nm 2θ50% 60 mA 120 ° Peak Wavelength Viewing Angle Phi 0° 365 nm mW V Certification: 0° -60° Compliant [2011/65/EU&2015/863] 100 REACh Approval Conform or declared [(EC)1907/2006] 90 Halogen Free Conform [JEDEC JS709B] 80 Halogen Free Conform [IEC 61249-2-21] Relative Intensity (%) RoHS Approval 10° 20° 30° 40° 45° 70 50° 60 60° 60° 50 40 70° 30 20 80° 10 90° -90 -45 0 10 20 30 40 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE DoK 001.000 2022-02-21 DIN ISO 2768-1m 50 60 70 80 90 100 PROJECTION METHOD DESCRIPTION Würth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions Max-Eyth-Str. 1 74638 Waldenburg Germany Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos@we-online.com WL-SUTW SMT Ultraviolet TopLED Waterclear ORDER CODE 153283367A212 SIZE/TYPE BUSINESS UNIT STATUS PAGE 2835 eiPal Valid 2/9 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Spectral: Forward Current vs. Forward Voltage: 100 90 80 100 70 Forward Current [mA] Relative Intensity [%] 80 60 40 20 60 50 40 30 0 280 300 320 340 360 380 Wavelength [nm] 400 420 440 460 480 20 10 0 0,0 1,0 2,0 3,0 4,0 5,0 Forward Voltage [V] CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE DoK 001.000 2022-02-21 DIN ISO 2768-1m PROJECTION METHOD DESCRIPTION Würth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions Max-Eyth-Str. 1 74638 Waldenburg Germany Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos@we-online.com WL-SUTW SMT Ultraviolet TopLED Waterclear ORDER CODE 153283367A212 SIZE/TYPE BUSINESS UNIT STATUS PAGE 2835 eiPal Valid 3/9 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Radiant Flux vs. Forward Current: Derating Curve: 70 2,0 1,8 60 1,6 50 Forward Current [mA] Relative Radiant Flux 1,4 1,2 1,0 0,8 40 30 20 0,6 10 0,4 0,2 0 0 20 40 60 80 100 0,0 0 20 40 60 80 Ambient Temperature [°C] 100 Forward Current [mA] CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE DoK 001.000 2022-02-21 DIN ISO 2768-1m PROJECTION METHOD DESCRIPTION Würth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions Max-Eyth-Str. 1 74638 Waldenburg Germany Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos@we-online.com WL-SUTW SMT Ultraviolet TopLED Waterclear ORDER CODE 153283367A212 SIZE/TYPE BUSINESS UNIT STATUS PAGE 2835 eiPal Valid 4/9 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Packaging Specification - Tape: [mm] Packaging Specification - Reel: [mm] P0 A D0 K0 P2 T E1 W3 W1 close to center A E2 B0 N W F D B C Top Cover Tape D1 A P1 W2 T1 A0 T2 End Polarity Mark Feeding direction Carrier Tape Start detail B Cover Tape B Cover Tape Chip Cavity Sprocket Hole No Component min.160mm Components No Component min.100mm Embossment Cover Tape min. 400mm Tape Type Tolerance Value 2a A0 (mm) typ. 3,02 B0 (mm) typ. 3,84 W (mm) +0,3/ -0,1 8,00 T (mm) ref. T1 (mm) ref. 0,10 T2 (mm) typ. 1,15 K0 (mm) typ. 0,95 P0 (mm) ±0,1 4,00 P1 (mm) ±0,1 4,00 P2 (mm) ±0,05 2,00 D0 (mm) +0,1/ -0,0 1,50 D1 (mm) min. 0,30 E1 (mm) ±0,1 1,75 E2 (mm) min. 6,25 F (mm) ±0,05 3,50 Material Polystyrene Qty. (pcs.) 4000 165° - 180° Tolerance Value A (mm) ± 2,0 178 B (mm) min. 1.5 C (mm) min. 12.8 D (mm) min. 20.2 N (mm) typ. 59 W1 (mm) +1,5 8.4 W2 (mm) max. 14.4 CHECKED REVISION DATE (YYYY-MM-DD) GENERAL TOLERANCE DoK 001.000 2022-02-21 DIN ISO 2768-1m W3 (mm) min. 7.9 W3 (mm) max. 10.9 Material Polystyrene PROJECTION METHOD DESCRIPTION Pull-of force Tape width 8 mm 0,1 N - 1,0 N Würth Elektronik eiSos GmbH & Co. KG EMC & Inductive Solutions Max-Eyth-Str. 1 74638 Waldenburg Germany Tel. +49 (0) 79 42 945 - 0 www.we-online.com eiSos@we-online.com WL-SUTW SMT Ultraviolet TopLED Waterclear ORDER CODE 153283367A212 SIZE/TYPE BUSINESS UNIT STATUS PAGE 2835 eiPal Valid 5/9 This electronic component has been designed and developed for usage in general electronic equipment only. This product is not authorized for use in equipment where a higher safety standard and reliability standard is especially required or where a failure of the product is reasonably expected to cause severe personal injury or death, unless the parties have executed an agreement specifically governing such use. Moreover Würth Elektronik eiSos GmbH & Co KG products are neither designed nor intended for use in areas such as military, aerospace, aviation, nuclear control, submarine, transportation (automotive control, train control, ship control), transportation signal, disaster prevention, medical, public information network etc.. Würth Elektronik eiSos GmbH & Co KG must be informed about the intent of such usage before the design-in stage. In addition, sufficient reliability evaluation checks for safety must be performed on every electronic component which is used in electrical circuits that require high safety and reliability functions or performance. Classification Reflow Profile for SMT components: Classification Reflow Soldering Profile: Profile Feature Tp tp Max. Ramp Up Rate Max. Ramp Down Rate TL Temperature Ts max tL Preheat Area Ts min TC –5°C Value Preheat Temperature Min Ts min 150 °C Preheat Temperature Max Ts max 200 °C Preheat Time ts from Ts min to Ts max ts Ramp-up Rate (TL to TP) max. 60 - 120 seconds 3 °C/ second max. Liquidous Temperature TL 217 °C Time tL maintained above TL tL max. 60 seconds Peak package body temperature Tp Tp ≤ Tc, see Table below Time within 5°C of actual peak temperature tp max. 10 seconds Ramp-down Rate (TP to TL) 6 °C/ second max. Time 25°C to peak temperature max. 220 seconds refer to IPC/ JEDEC J-STD-020E tS Package Classification Reflow Temperature (Tc): Volume mm³ 350-2000 Volume mm³ >2000 PB-Free Assembly | Package Thickness 260 °C < 1.6 mm 260 °C 260 °C PB-Free Assembly | Package Thickness 260 °C 1.6 mm - 2.5 mm 250 °C 245 °C PB-Free Assembly | Package Thickness 250 °C > 2.5 mm 245 °C 245 °C Properties 25 Time 25°C to Peak Time Applied cycles Volume mm³
153283367A212 价格&库存

很抱歉,暂时无法提供与“153283367A212”相匹配的价格&库存,您可以联系我们找货

免费人工找货