0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
会员中心
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
PDU3EVSR6H50A

PDU3EVSR6H50A

  • 厂商:

    TRIPPLITE

  • 封装:

  • 描述:

    PDU 3-PHASE SWITCHED 14.4KW 208V

  • 数据手册
  • 价格&库存
PDU3EVSR6H50A 数据手册
1000 Eaton Boulevard Cleveland, OH 44122 United States 14.4kW 208V 3PH Switched PDU - LX Interface, Gigabit, 18 Outlets, Hubbell 50A CS8365C Input, Outlet Monitoring, LCD, 1.8 m Cord, 0U 1.8 m Height, TAA Highlights ● 6 C13 and 12 C19 208V outlets distribute AC power to connected equipment ● Pre-installed GbE-capable WEBCARDLX with latest version of PADM20 for IP-based Auto Probe feature ● Remote power monitoring and control reduces on-site visits and maintenance costs ● 1.8 m power cord with Hubbell 50A CS8365C (3P+E) 3-phase input connects to AC power source ● Color touchscreen LCD provides current levels, environmental data and network info MODEL NUMBER: PDU3EVSR6H50A Applications ● Power mission-critical rack equipment in a data center, computer room or high-density network closet ● Monitor power loads from various computers, switches, servers and other networking equipment ● Maintain a computer network in a government, commercial or industrial facility ● Manage multiple rack devices by rebooting or shutting down individual outlets as needed 3-phase switched PDU distributes, monitors and manages power in a medium/large data center or network installation. Features 3-Phase PDU Distributes, Monitors and Manages Network-Grade PowerRecommended for data centers, server rooms and high-density network closets, this switched PDU provides advanced network control and remote power monitoring with the ability to turn on, turn off, reboot or lock out power to each outlet. You can more efficiently manage network power consumption and remotely reboot locked network items without having to visit the site. Reducing the number of on-site visits can help lower the cost of data center maintenance, thus lowering the 0U PDU's total cost of ownership. 18 Outlets Dispense AC Power to Connected EquipmentDuring normal operation, 18 individually controllable outlets—six C13 and 12 C19—in six separately breakered load banks distribute AC power to rack equipment. Each 208V outlet is accompanied by an LED that illuminates when the outlet is ramped up and ready to be used. The outlets and banks can be individually monitored to ensure proper load balance and prevent downtime. Plug-lock insert sleeves are included to prevent connected cables from becoming accidentally dislodged. Built-In GbE-Capable Network Management Card Allows Remote Access 24/7The built-in WEBCARDLX with the latest version of PowerAlert Device Manager firmware (PADM20) provides enhanced remote management capabilities, including customizable dashboard graphs to fit user preferences. The PADM20 upgrade and PowerAlert Element Manager (PAEM) software form a powerful tool for expanding maintenance functions in large installations, including firmware update checks and backup and restoration of device configurations. PADM20’s Auto Probe feature allows a PDU with switched loads to automatically reboot devices if a network communication failure is detected. This preserves uptime and minimizes the time and expense associated with on-site support. Color Touchscreen LCD Offers Important Data at a GlanceAn easy-to-navigate color touchscreen LCD reports network data, input current level per phase, and output current per load bank and per outlet with ±1% billing-grade accuracy. It also generates a unique QR code to allow read-only access to the 3-phase PDU via mobile device. If an EnviroSense2 module is connected to the PDU, the LCD also displays its status and environmental data, such as temperature and humidity. 1/4 Package Includes ● PDU3EVSR6H50A 14.4kW 3Phase Switched PDU ● Built-in LX Platform interface ● Configuration cable ● (18) Plug-lock insert sleeves ● Rack-mounting hardware ● Spare mounting buttons ● PDUMVROTATEBRKT mounting bracket accessory ● Owner’s manual 1000 Eaton Boulevard Cleveland, OH 44122 United States Easy to Install Vertically in an EIA-Standard 19 in. RackThe 70-inch 0U PDU mounts vertically using the pre-installed toolless mounting buttons or the included brackets. Spare buttons are also included. Use the included PDUMVROTATEBRKT kit to install the Hubbell PDU with outlets facing the rear for better airflow or equipment access. A 6-ft. (1.83 m) cord with Hubbell 50A CS8365C (3P+E) 3-phase input connects the switched PDU to a compatible AC power source, generator or protected UPS. TAA-Compliant for GSA Schedule PurchasesThe PDU3EVSR6H50A is compliant with the Federal Trade Agreements Act (TAA), which makes it eligible for GSA (General Services Administration) Schedule and other federal procurement contracts. 2-Year WarrantyThe PDU3EVSR6H50A is backed by a 2-year warranty, ensuring reliability and performance. Specifications OVERVIEW UPC Code 037332206763 PDU Type Switched INPUT Input Phase 3-Phase PDU Input Voltage 208 Recommended Electrical Service Three-phase 50A 208V service Maximum Input Amps 40 Maximum Input Amps Details Agency de-rated to 40A continuous PDU Plug Type HUBBELL CS8365C 50A Input Cord Details 6GA (SOOW) Input Cord Length (ft.) 6 Input Cord Length (m) 1.83 OUTPUT Output Capacity Details 14.4kW (208V) total capacity; 20A max per breakered outlet bank; 16A max per C19 outlet; 12A max per C13 outlet Frequency Compatibility 50 / 60 Hz Output Receptacles (6) C13; (12) C19 Output Nominal Voltage 208V Overload Protection Six 20A circuit breakers, 1 per outlet bank Customized Load Management Receptacles Each outlet is individually controllable via remote interface USER INTERFACE, ALERTS & CONTROLS Reported Load Segments Supports monitoring of current per input phase (L1, L2, L3), output current per load bank (Banks 1-6) and per output receptacle (1-18); Outlets are color-coded and labeled for phase and load bank identification; L1-L2 powers black outlets (Banks 1&4); L2-L3 powers dark-gray outlets (Banks 2&5); L3-L1 powers light-gray outlets (Banks 3&6) 2/4 1000 Eaton Boulevard Cleveland, OH 44122 United States Front Panel LCD Display Touchscreen LCD reports NETWORK DATA (IP address, Subnet Mask, Gateway, MAC Address, Device Name, Model, Serial Number), INPUT PHASE DATA (Amperage, Wattage, Voltage per phase, plus Unbalance percentage), LOAD BANK DATA (Amperage, Wattage, Voltage per load bank, plus total PDU output in watts), CONFIGURATION DATA (Listing of current configuration settings), ENVIRONMENTAL DATA (Reports data and status of E2 sensor modules; Sensor options are available for temperature and humidity, plus input and output dry contacts), MOBILE ACCESS (Generates a unique QR code to view reported PDU details on a mobile device) Front Panel LEDs One LED for each output receptacle offers power availability information: GREEN (Power ON), YELLOW (Warning condition), RED (Critical condition). Network Activity (Green): Flashes for network activity. Link/Network Speed (Yellow): On steady for any speed. Switches LX Platform Interface: Recessed reset switch for interface reboot and factory reset Current Measurement Accuracy (Amps) +/-1% Voltage Measurement Accuracy (Volts) +/-1% Power Measurement Accuracy (Watts) +/-1% SURGE / NOISE SUPPRESSION Automatic Shut-Off No PHYSICAL Material of Construction Metal Form Factors Supported Vertical rackmount installation supported with included mounting brackets; supports toolless mounting in buttonmount compatible racks PDU Form Factor Vertical (0U) Shipping Dimensions (hwd / in.) 7.09 x 9.65 x 75.87 Shipping Weight (kg) 12.51 Unit Dimension Details Chassis dimensions shown; See submittal drawing for further detail Unit Dimensions (hwd / in.) 70.000 x 2.170 x 2.490 Unit Dimensions (hwd / cm) 177.8 x 5.5 x 5.406 Unit Weight (lbs.) 20.57 Unit Weight (kg) 9.33 ENVIRONMENTAL Operating Temperature Range 32° to 104°F (0° to 40°C) Storage Temperature Range -22° to 122°F (-30° to 50°C) Relative Humidity 5% to 95% non-condensing Operating Elevation (ft.) 0-10,000 Operating Elevation (m) 0-3000 COMMUNICATIONS PowerAlert Software LX Platform Interface: PowerAlert Device Manager Communications Cable USB B-to-USB A Configuration/Console Access cable 3/4 1000 Eaton Boulevard Cleveland, OH 44122 United States Network Monitoring Port RJ45 Network port, RJ45 Config/Console Access port; 2x USB A ports supports a variety of Envirosense2 environmental and control modules. See Accessories>Management Hardware section for more information about these modules. USB B port (Configuration & Console Access) SNMP Compatibility SNMP V1, V2c, V3 Network Compatibility 10 Mbps; 100 Mbps (Fast Ethernet); 1 Gbps (Gigabit) Communications Interface Pre-installed network card; RS-232; USB FEATURES & SPECIFICATIONS High Availability PDU Features Auto Probe Monitoring and Reboot (included); Auto Load Shedding STANDARDS & COMPLIANCE Product Certifications CAN/CSA-C22.2 No. 60950-1 (Canada); NOM (Mexico); UL 60950-1 Product Compliance RoHS; FCC Part 15 Class A (USA); Trade Agreements Act (TAA) WARRANTY & SUPPORT Product Warranty Period (Worldwide) 2-year limited warranty © 2023 Eaton. All Rights Reserved. Eaton is a registered trademark. All other trademarks are the property of their respective owners. 4/4
PDU3EVSR6H50A 价格&库存

很抱歉,暂时无法提供与“PDU3EVSR6H50A”相匹配的价格&库存,您可以联系我们找货

免费人工找货