0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
1658-A21-06-P10-5A

1658-A21-06-P10-5A

  • 厂商:

    E-T-A

  • 封装:

  • 描述:

    CIRC BRKR THRM

  • 数据手册
  • 价格&库存
1658-A21-06-P10-5A 数据手册
Thermal Overcurrent Circuit Breaker 1658-... Description Very cost effective design to meet international requirements. No exposed metal parts which are, or could become, current-carrying except for terminals. R-type TO CBE to EN 60934. ● Manual reset, cycling trip free mechanism ● Extremely small and lightweight ● UL, CSA, VDE and EN 60934 (IEC 60934) approved 1 Typical applications Battery chargers, consumer products, power supplies, motors. 1658-... Ordering information Type No. 1658 single pole thermal circuit breaker Threadneck design G21 manual reset type, 3/8“-27 threadneck G41 manual reset type, 7/16“-28 threadneck A21 auto reset type, 3/8“-27 threadneck A41 auto reset type, 7/16“-28 threadneck A00 auto reset type, without threadneck F01 snap in Hardware 00 no hardware 01 one PAL nut, bulk 02 one PAL nut, one knurled nut, bulk 03 one PAL nut mounted 04 one PAL nut, one knurled nut, mounted 05 one PAL nut mounted, one knurled nut, bulk 06 one knurled nut, bulk 07 one hex nut, bulk 08 two hex nuts, bulk Terminals P10 blade terminals A6.3-0.8 (QC .250) P13 blade terminals A6.3-0.8 (QC .250), 90° S80 straight screw terminals* S83 90° bent screw terminals* Current ratings 5 ...30 A 1658 - G21 - 02 - P10 - 5 A Technical data For further details please Voltage rating Current ratings Typical life AC + DC 5...16 A 17...25 A Ambient temperature Insulation co-ordination (IEC 60664 and 60664 A) Ordering example Standard current ratings and typical voltage drop values Voltage drop (mV) ≤ 250 ≤ 250 ≤ 250 ≤ 250 ≤ 250 ≤ 250 Current rating (A) 12 15 16 20 25 30 1,000 operations at 2 x IN, inductive 1,000 operations at 2 x IN, resistive -20...+60 °C (-4...+140 °F), ≤ 7 A max. +40 °C (+104 °F) rated impulse pollution withstand voltage degree 2.5 kV 2 reinforced insulation in operating area Dielectric strength (IEC 60664 and 60664A) operating area Insulation resistance Interrupting capacity Icn * Screws and lock washers bulk shipped Current rating (A) 5 6 7 8 9 10 see chapter: Technical Information AC 240 V; DC 28 V 5...30 A Voltage drop (mV) ≤ 250 ≤ 250 ≤ 250 ≤ 250 ≤ 250 ≤ 250 test voltage AC 3,000 V > 100 MΩ (DC 500 V) 5...7 A 180 A 8...30 A 200 A UN Interrupting capacity IN (UL 1077/EN 60934 PC1) 5...16 A AC 240 V 2,000 A 17...30 A AC 120 V 2,000 A 5...30 A DC 32 V 2,500 A 5...30 A DC 28 V 2,000 A (1658-A..) Degree of protection operating area IP40 (IEC 60529/DIN 40050) terminal area IP00 Vibration 8 g (57-500 Hz) ± 0.61 mm (10-57 Hz), to IEC 60068-2-6, test Fc, 10 frequency cycles/axis Shock 30 g (11 ms) to IEC 60068-2-27, test Ea Corrosion 96 hours at 5 % salt mist, to IEC 60068-2-11, test Ka Humidity 240 hours at 95 % RH to IEC 60068-2-78, test Cab Mass approx. 16 g Approvals Authority VDE (EN 60934) UL Issue B(020810) Voltage rating AC 240 V; DC 28 V AC 240 V AC 120 V AC 120 V DC 32 V DC 28 V Current ratings 5...25 A 5...16 A 1658-G../F.. 18...30 A 1658-G../F.. 5...30 A 1658-A... 5...30 A 1658-G../F.. 5...30 A 1658-A.. www.e-t-a.com 1 - 63 Thermal Overcurrent Circuit Breaker 1658-... Terminal design ø6 .236 1 1 2 8.5 .335 terminal screw 6-32 UNC blade terminals DIN 46244-A6.3-0.8 (QC .250) 2 12 .472 1 2 12 .472 27 1.06 6 .236 1 .039 1 S83 3 .118 P10 0.7 .028 12.7 .500 ON OFF Dimensions P13 lock washer P10-S83 3 .118 17.5 .689 15.7 .618 2 1 8.5 .335 blade terminals DIN 46244-A6.3-0.8 (QC .250) angled 90° 13.6 .535 14 .551 1 32 1.26 2 lock washer terminal screw 6-32 UNC blade terminals DIN 46244-A6.3-0.8 (QC .250) S80 A00 A21 tightening torque max. 0.8 Nm 3/8-27UNS-2A mounting hole terminal screw 6-32 UNC 8.9-0.1 .350-.004 9.6-0.1 .378-.004 G21 2 12 .472 1 tightening torque max. 0.8 Nm 3/8-27UNS-2A lock washer Installation drawing 7 .276 4 .157 operating area 1 34 1.34 mounting hole 10.2±0.1 .402±.004 10 .394 A41 2 5 .197 5 .197 4 4 .157 .157 7/16-28UNS-2A double “D“ tightening torque max. 0.8 Nm G41 11.2±0.1 .441±.004 mounting area 10 .394 ø6 .236 Caution: Please keep a tight grip on the unit while removing the female connectors. mounting hole +0.1 - 0.2 +.004 .543 - .008 13.8 16±0.15 .630±.006 12.7 .500 ON 6 .236 1 .039 OFF F01 thickness 1- 3 mm .039 - .118 in. See ordering information for mounting hardware. This is a metric design and millimeter dimensions take precedence ( mm ) inch 1 - 64 www.e-t-a.com Issue B(020810) Thermal Overcurrent Circuit Breaker 1658-... Internal connection diagram Accessories 1 Mounting nut 3/8", 27-thread Y 306 671 01 14.3 .563 2.5 .098 0.5 .020 Mounting nut 7/16", 28-thread Y 303 200 01 16 .630 0.5 .020 3 .118 1 2 3/8-27UNS-2B Typical time/current characteristics 10000 +60 °C +140 °F +23 °C +73.4 °F -20 °C -4 °F Trip time in seconds 1000 7/16-28UNEF-2B Knurled nut 3/8", 27-thread plastic (standard) Y 307 117 02 Knurled nut 7/16", 28-thread nickel-plated brass Y 302 294 03 ø15 .591 3 .118 ø16 .630 3.2 .126 100 7/16-28UNEF-2B 3/8-27UNS-2B Knurled nut 3/8", 27-thread nickel-plated brass Y 300 190 03 10 ø13 .512 1 2.5 .098 0.1 2 4 6 8 10 … times rated current 20 40 3/8-27UNS-2B The time/current characteristic curve depends on the ambient temperature prevailing. In order to eliminate nuisance tripping, please multiply the circuit breaker current ratings by the derating factor shown below. See also section Technical information. Ambient temperature °F °C Derating factor IN > 7A IN ≤ 7A -4 -20 0.83 0.74 +14 -10 0.85 0.76 +32 0 0.9 0.82 +73.4 +23 1 1 Hex nut 3/8", 27-thread nickel-plated brass Y 300 192 01 +104 +122 +140 +40 +50 +60 1.1 1.18 1.25 1.23 - 3/8-27UNS-2B Hex nut 7/16", 28-thread nickel-plated brass Y 302 295 01 2.5 .098 7/16-28UNEF-2B SW14 .551 SW14 .551 Press to Reset Plate for 3/8" thread, aluminium Y 301 059 02 ø21.4 .843 E-T - T T BREA R PR E SE 0.4 .016 KE A SS E TO RE PR SS E- T - ø24 .945 ® R KE BREA ø9.9 .390 Press to Reset Plate for 7/16" thread, aluminium Y 302 732 01 0.4 .016 A ® 2.5 .098 SE 1 E TO R ø11.2+0.7 .441+.028 This is a metric design and millimeter dimensions take precedence ( mm ) inch Issue B(020810) www.e-t-a.com 1 - 65 Thermal Overcurrent Circuit Breaker 1658-... Accessories Reset button seal for 3/8", 27-thread, short long X 201 285 01 X 200 799 01 1 3/8-27 UNS-2B 3/8-27 UNS-2B Reset button seal for 7/16", 28-thread, short long X 222 119 01 X 222 119 02 7/16-28 UNS-2B 7/16-28 UNS-2B All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 1 - 66 www.e-t-a.com Issue B(020810)
1658-A21-06-P10-5A 价格&库存

很抱歉,暂时无法提供与“1658-A21-06-P10-5A”相匹配的价格&库存,您可以联系我们找货

免费人工找货