0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
8345-F02A-P0M1-DB1B1A-X8345-S02KW102M-2A

8345-F02A-P0M1-DB1B1A-X8345-S02KW102M-2A

  • 厂商:

    E-T-A

  • 封装:

  • 描述:

    CIR BRKR THRM 2A

  • 数据手册
  • 价格&库存
8345-F02A-P0M1-DB1B1A-X8345-S02KW102M-2A 数据手册
Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Description Single or multipole hydraulic-magnetic circuit breakers with trip-freemechanism and toggle actuation. A choice of switching characteristics ensures suitability for a wide range of applications. Industry standard dimensions and panel mounting. Auxiliary contacts optional. Low temperature sensitivity at rated load. Approved to CBE standard EN 60934 (IEC 60934)S-type HM CBE. NEW Typical applications In the business fields Communication and Transport: power supplies, switchgear, instrumentation and process control engineering. Standard current ratings and typical internal resistance values Current rating (A) 0.05 0.1 Trip curves and internal resistance (Ω) per pole F1 F2 K1, M1, T1, K2, M2, T2 276 152 452 376 58 37 100 0.58 0.35 0.95 2 0.145 0.096 0.26 0.20 3 0.065 0,048 0.10 0.10 5 0.025 0.042 0.040 < 0.02 < 0.02 < 0.02 < 0.02 15 < 0.02 < 0.02 < 0.02 < 0.02 20 < 0.02 < 0.02 < 0.02 < 0.02 25 < 0.02 < 0.02 < 0.02 < 0.02 30 < 0.02 < 0.02 < 0.02 < 0.02 < < < < < < < < < < < < < < < < < < < < < < < < 40 50 60 80 100 125 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 0.01 Voltage rating Current rating range 0.90 10 0.01 0.01 0.01 0.01 0.01 0.01 Auxiliary circuit Typical life Ambient temperature Insulation co-ordination (IEC 60664) Dielectric strength operating area pole to pole main to auxiliary circuit switching to trip circuit Insulation resistance Degree of protection (IEC 60529) Vibration Interrupting capacity to EN 60934, UL 489 and UL 1077 IEC 60934 – test series E voltage number of poles DC 80 V 1 DC 80 V 2 AC 240 V 1 AC 240/415 V 3 (4) UL 489 – test sequence Z voltage number of poles DC 80 V 1 DC 80 V 2 AC 120 V 1 AC 240 V 1 AC 120/240 V 1 (2) IN max. (A) 0.05...125 0.05...125 0.05...125 0.05...125 Icn 10,000 10,000 5,000 5,000 Shock Corrosion IN max. (A) 0.05...125 0.05...125 0.05...80 0.05...20 0.05...80 Icn 10,000 10,000 5,000 5,000 5,000 2 pole Technical data 94 1 < 0.02 8345 1 pole Humidity Mass 3 AC 415 V; AC 277/480 V; AC 120/240 V; AC 240 V; DC 80 V, 0.05...125 A single and multipole 150...180 A single pole, two poles connected in parallel higher ratings upon request AC 240 V/DC 28 V 6 A DC 65 V 1 A; DC 80 V 0.5 A 10,000 operations at 1 x IN 3 -40 °C...+85 °C (-40 °...+185 °F) 2.5 kV/2 reinforced insulation in operating area test voltage AC 3000 V AC 1500 V AC 1500 V AC 1500 V > 100 MΩ (DC 500 V) operating area IP40 terminal area IP00 with toggle down: 10 g (57-2000 Hz) ±0,76mm (10-57Hz) at 0.9 IN directions 1,2,3,4,5: 10 g at 1 x IN with curves F1, F2: 10 g at 0.8 x IN in all planes. (57-2000 Hz) ±0.76 mm (10-57 Hz) to IEC 60068-2-6, test Fc 10 frequency cycles/axis directions 1,2,3,4,5: 100 g (11 ms) at 1 x IN, direction 6: 100 g (11 ms) at 0.8 x IN, with curves F1, F2: 100 g (11 ms) at 0.8 x IN to IEC 60068-2-27, test Ea 96 hours at 5% salt mist, to IEC 60068-2-11, test Ka 240 hours at 95 % RH, to IEC 60068-2-3, test Ca approx. 90 - 120 g per pole depending on version Approvals UL 1077 voltage number of poles DC 80 V 1-6 AC 277/480 V 1-6 Issue G ☎ IN max. (A) 0.05...125 0.05...125 Icn 10,000 5,000 VDE (EN 60934) UL 489 UL 1077 Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com 201 Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Ordering information 3 Type No. 8345 Mounting B flange mounting, with rectangular aperture with mounting nut 6-32 UNC C flange mounting, with rectangular aperture with mounting nut M3 E flange mounting, with round aperture with mounting nut 6-32 UNC F flange mounting, with round aperture with mounting nut M3 Configuration 0 without barrier 1 with small barrier 2 with large barrier (required for UL 489 multipole) Number of poles 0 single pole unprotected 1 single pole protected 2 two pole protected 3 three pole protected 4 four pole protected P single pole protected, two poles connected in prallel Actuator configuration A all poles with standard toggle B reduced number of standard toggles Z without actuator Terminal design K screw terminals M4 ≤ 35 A L screw terminals M5 ≤ 50 A M solder terminals ≤ 75 A P blade terminals ≤ 35 A R round connectors 6 mm S stud terminals M5 ≤60 A T stud terminals 10-32 UNF-3A ≤ 60 A U stud terminals M6 V stud terminals 1/4-20UNC-3A ≤ 125 A Terminal hardware 0 without 3 with washer and nut 6 Phillips screws Characteristic curve F1 instantaneous trip DC 1.01-1.5 x IN F2 instantaneous trip AC 1.01-1.5 x IN K1 short delay DC K2 short delay AC M0 medium delay AC/DC M1 medium delay DC M2 medium delay AC Q0 switch only T1 long delay DC T2 long delay AC Illumination - without Version D standard Colour configuration B1 black front plate, black actuator, (black actuator base) B2 black front plate, black actuator, (white actuator base) Marking front plate A1 without A2 IN A3 IN 8345 - C 0 1 A - U 3 M1 - . D B1 A1 B - ... Current ratings 0.1...125 A 150 - 180 A single pole protected, two poles connected in parallel Approvals (optional) V UL 489 8345 - C 0 1 A - U 3 M1 - . D B1 A1 B - 60 A - . ordering example Remote trip coil available to special order! Ordering information for auxiliary contact module Type number X8345 Module S auxiliary contact module Auxiliary contacts 01 in all poles 02 in pole 1 only 03 in poles 1 + 3 only 04 in pole 2 only Auxiliary contact version H auxiliary contacts standard (asymmetrical terminals not for UL 489) K auxiliary contacts (symmetrical terminals) Auxiliary contact function W1 1 changeover Terminal design 02 microswitch with blade terminals DIN 46244-A2,8-0,5 M mounted to base unit X8345 - S 01 H W1 02 M ordering example actuator base without without without characteristic curve A4 IN, without characteristic curve, wiring diagram on side B1 without ON-OFF B2 IN ON-OFF B3 IN ON-OFF characteristic curve B4 IN, ON-OFF characteristic curve, wiring diagram on side Rated voltage B AC or ≤ 80 V DC 8345 - C 0 1 A - U 3 M1 - . D B1 A1 B - 60 A - ... 202 ☎ Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Issue G Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Dimensions Installation drawing Mounting version B/C number of poles 1 to 4 Flange mounting rectangular aperture pole 2 3 4 LINE 1 .039 1.13 28.6 1 mounting thread M3 or 6-32 mounting depth 4.2 mm/.165 in. 48 1.89 operating area (reinforced insulation) 63.5 2.50 ON mounting terminal area area Cut-out dimensions: 11 .433 2 .079 9.6 .378 19.2 .756 Mounting version E/F pole Actuator configuration 1 2 3 A 1 toggle per pole 4 mounting thread M3 or 6-32 mounting depth 4.2 mm/.165 in. 1.13 LINE 48 1.89 28.6 3 28.6 1.13 number of poles 1 to 4 Flange mounting round aperture 2 .079 52.4 2.06 36.8 1.45 ø4 .157 LOAD 1 pole multipole 76.2 3.00 66.6 2.62 47.6 1.87 29 1.14 LINE 19 .748 68 2.25 8 .315 30 1.18 LOAD OFF 63.5 2.50 ON LOAD OFF 68 2.25 B reduced number of toggles per unit 19 .748 Cut-out dimensions: 1 pole 4 pole .138±.004 (M3) +.004 .157-.006 (6-32UNC) 57 2.24 38 1.50 Z without toggles ø14.5 .571 15.45 .608 44.75 1.76 ø14.5 .571 3.5±0.1 (M3) +0.1 4 -0.15 (6-32UNC) 19 .748 This is a metric design and millimeter dimensions take precedence ( mm ) inch Issue G ☎ Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com 203 Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Terminal design / Dimensions Number of poles / Dimensions P - with blade terminals P 1 pole protected, 2 poles connected in parallel for rating currents from 150 to 180 A 49.2 1.94 M8 12 .472 49.2 1.94 93.2 3.67 .579 49.2 1.94 14.7 LINE LINE 21 LOAD LOAD blade terminal A6.3-0.8 (QC .250) DIN 46244 tightening torque: M6 max. 3 Nm LINE M - with solder = 9.4 .370 1.5 .059 31 1.22 = LOAD .827 LINE 4 LOAD .157 14.6 .575 tightening torque: M8 max. 6 Nm terminal with flat head screw M4 or M5 tightening torque max. 1.2 Nm 3 terminals 3 ø6 .236 .118 Interphase barriers / Dimensions 49.2 2 .079 1.94 LINE 15.9±1 4 .157 LINE LINE LOAD 34 1.34 LOAD 1.94 LINE 21 .827 17.5 .689 LOAD 5.08 .295 17.5 .689 16.45 .648 82 3.23 .626±.039 S/U/T/V with auxiliary contacts (version H) asymmetrical terminals 49.2 (not for UL 489) 74 2.91 82 3.23 1.5 .059 auxiliary contact module (change over) 2 - Interphase barrier (large) 1 - Interphase barrier (small) 4.2 .165 18.8 .740 LOAD 10.16 .295 tightening torque: 10-32 UNF, M5 max. 2 Nm 1/4-20 UNC, M6 max. 3 Nm R round connectors D = 6 mm (dia .236) (version H) asymmetrical terminals (not for UL 489) LINE 100 3.94 thickness 1mm / .039 in. Internal connection diagram 1 pole protected magnetically line 1 49.2 1.94 multi pole unit 1 12 14 12 S/U/T/V with auxiliary contacts (version K) symmetrical terminals 2 2 1 pole protected hydraulic-magnetically line 1 11 1 unit 2 11 12 7.5 .295 17.85 .703 tightening torque: 10-32 UNF, M5 max. 2 Nm 1/4-20 UNC, M6 max. 3 Nm 12 14 2 unit 3 I> ... 15 .591 I> 2 unit 4 ... NC NO C 7.5 .295 auxiliary contact module (change over) 16.35 .644 14 LINE 17.5 .689 21 .827 LOAD 14 I> I> 49.2 1.94 11 line 1 11 19 .748 17.5 .689 LOAD 75 2.95 R round connectors D = 6 mm (dia .236) (version K) symmetrical terminals LINE 19 .748 17.5 .689 LOAD 49.2 1.94 204 ☎ This is a metric design and millimeter dimensions take precedence ( mm ) inch Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Issue G Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Typical time/current characteristics at +23 °C / +73.4 °F (trip time at rated current and all poles symmetrically loaded) Curve M0 (medium delay) for AC/DC Curve F1 (instantaneous) for DC 1000 1000 100 100 Trip time in seconds 10000 Trip time in seconds 10000 10 1 0.1 0.01 10 1 0.1 0.01 0.001 0.001 0 1 2 3 4 6 8 5 7 … times rated current 9 10 11 12 0 10000 1000 1000 100 100 Trip time in seconds 10000 Trip time in seconds 2 3 4 6 8 5 7 … times rated current 9 10 11 12 Curve M1 (medium delay ) for DC Curve F2 (instantaneous) for AC 50/60 Hz 10 1 0,1 0.01 3 10 1 0.1 0.01 0.001 0.001 0 1 2 3 4 6 8 5 7 … times rated current 9 10 11 12 Curve K1 (short delay) for DC 0 1 2 3 4 6 8 5 7 … times rated current 9 10 11 12 9 10 11 12 Curve M2 (medium delay) for AC 50/60 Hz 10000 1000 1000 100 100 Trip time in seconds 10000 Trip time in seconds 1 10 1 0.1 0.01 10 1 0,1 0,01 0.001 0 1 2 3 4 6 8 5 7 … times rated current 9 10 11 12 9 10 11 12 0.001 0 1 2 3 4 6 8 5 7 … times rated current Curve K2 (short delay) for AC 50/60 Hz 10000 Trip time in seconds 1000 100 10 1 0.1 0.01 0.001 0 1 2 3 4 6 8 5 7 … times rated current All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order ( e. g. pulse delayed, for high inrush currents or capacitive loads). Issue G ☎ Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com 205 Magnetic and Hydraulic-Magnetic Circuit Breaker 8345-... Typical time/current characteristics at +23 °C / +73.4 °F (trip time at rated current and all poles symmetrically loaded) Curve T1 (long delay) for DC 10000 Accessories Splash cover (IP64) for 1, 2, 3 pole (only for mounting version B/C) Y 306 265 01 1 pole Y 306 266 01 2 pole Y 306 267 01 3 pole 1000 Trip time in seconds 100 10 1 0.1 19.5 .768 0.01 0.001 0 1 2 3 4 6 8 5 7 … times rated current 9 10 12 11 Toggle guard (only for mounting version B/C) Y 307 381 01 Curve T2 (long delay) for AC 50/60 Hz 64 2.52 10000 3 19.6 .772 1000 2.8 .110 10 37.3 1.47 16.7 .657 1 19.2 .756 Trip time in seconds 100 0.1 ø4 .157 0.01 0.001 0 1 2 3 4 6 8 5 7 … times rated current 9 10 11 52.4 2.06 12 All curves will only be maintained if the escutcheon is mounted on a vertical surface. Other characteristic curves to special order ( e. g. pulse delayed, for high inrush currents or capacitive loads). Shock directions 2 4 3 1 6 5 E LIN AD LO This is a metric design and millimeter dimensions take precedence ( mm ) inch All dimensions without tolerances are for reference only. In the interest of improved design, performance and cost effectiveness the right to make changes in these specifications without notice is reserved.Product markings may not be exactly as the ordering codes. Errors and omissions excepted. 206 ☎ Germany (0 91 87) 10-0 - USA (847) 827-7600 - UK (01296) 420336 - www.e-t-a.com Issue G
8345-F02A-P0M1-DB1B1A-X8345-S02KW102M-2A 价格&库存

很抱歉,暂时无法提供与“8345-F02A-P0M1-DB1B1A-X8345-S02KW102M-2A”相匹配的价格&库存,您可以联系我们找货

免费人工找货