X-Cite® illuminators have been qualified for the following microscopes:
Light Guide Adaptor
For: X-Cite 120Q series, XLED1,
110LED, TURBO, XYLIS, NOVEM
Also: 200DC, exacte, FIRE
Direct Coupling Flange
For: X-Cite mini+
Also: 120LED, 120LEDmini
Direct Coupling Flange
For: X-Cite 120LEDBoost
CARL ZEISS
AxioExaminer
AxioImager
AxioObserver
AxioScope A1
AxioScope 5
AxioScan
AxioVert A1
AxioZoom
Discovery.v8 / .v12 / .v20
LSM
M2Bio (w/Kramer attachment)
810-00022X
810-00022X
810-00022X
810-00022X
810-00022X
810-00022X
810-00022X
No adaptor req’d*
No adaptor req’d*
No adaptor req’d*
810-00022X
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
N/A
N/A
N/A
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
Not recommended
810-10022X
N/A
N/A
N/A
TBD
Axiophot, Axiophot2
Axioplan 1, 2
Axioskop 1, 20, 50
Axioskop 2, 2FS, 40
AxioTech
Axiovert 10, 35, 100, 135, S100TV
Axiovert 200
Axiovert 400
Axiovert 25, 40
Stemi SV11
Stereo Lumar
810-00022X
810-00022X
810-00022X
810-00022X / 810-00035X†
810-00022X
810-00035X
810-00022X / 810-00035X†
810-00035X
810-00037
No adaptor req’d*
810-00022X
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
TBD
810-10022X
TBD
810-10022X
N/A
810-10022X
810-10022X
810-10022X
810-10022X
810-10022X
TBD
TBD
TBD
TBD
TBD
N/A
TBD
Microscope Model
Notes:
* Additional fittings and/or specific configuration from microscope manufacturer may be required.
† With external devices (e.g. shutters, filter wheels, etc) installed between the adaptor and microscope, use 810-00035X.
X-Cite and microscope models in italics have been discontinued.
June 2021
X-Cite® illuminators have been qualified for the following microscopes:
Light Guide Adaptor
For: X-Cite 120Q series, XLED1,
110LED, TURBO, XYLIS, NOVEM
Also: 200DC, exacte, FIRE
Direct Coupling Flange
For: X-Cite mini+
Also: 120LED, 120LEDmini
Direct Coupling Flange
For: X-Cite 120LEDBoost
LEICA
DM4B, DM6B
DMi8 – Manual
DMi8 – Automated w/FIM
DMIL
DM2000/2500/3000
M165FC, M205FA
MZ10F
810-00033X
810-00033X
No adaptor req’d*
810-00033X
810-00033X
810-00038X
810-00038X
Not recommended
810-10033X
N/A
TBD
TBD
810-10038X‡
TBD
810-10033X + 8mm spacer
TBD
N/A
TBD
TBD
TBD
TBD
DM4000-6000
DMI4000
DMI6000B
DMIRB, DMIRM, DMIRE2
DMLB
DMLFS
DMR, DMRXA, DMRXA2
MZFLIII
MZ16F, MZ16FA
M10, MZ9.5
Leitz - all models
810-00033X
810-00033X
810-00033X
810-00033X
810-00033X
810-00033X
810-00033X
810-00038X
810-00038X
810-00038X
Incompatible
TBD
TBD
810-10033X
Not recommended
TBD
TBD
TBD
810-10038X‡
TBD
TBD
Incompatible
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
TBD
Incompatible
Microscope Model
Notes:
* Additional fittings and/or specific configuration from microscope manufacturer may be required.
‡ May not be suitable for some applications, demo before purchase recommended.
X-Cite and microscope models in italics have been discontinued.
June 2021
MG
X-Cite® illuminators have been qualified for the following microscopes:
Light Guide Adaptor
For: X-Cite 120Q series, XLED1,
110LED, TURBO, XYLIS, NOVEM
Also: 200DC, exacte, FIRE
Direct Coupling Flange
For: X-Cite mini+
Also: 120LED, 120LEDmini
Direct Coupling Flange
For: X-Cite 120LEDBoost
NIKON
AZ100
Ci
FN1
LV100
Ni
Ti
Ti2 (w/Ti-LAPP)
SMZ18, SMZ25
SMZ1270i/1270/800N
For “white light TIRF”
No adaptor req’d*
810-00030X
810-00030X
N/A
810-00030X
810-00030X
No adaptor req’d*
No adaptor req’d*
No adaptor req’d*
810-00045
N/A
810-10030X
810-10030X
810-10097X
810-10030X
810-10030X
N/A
N/A
N/A
N/A
N/A
Not recommended
TBD
TBD
Not recommended
Not recommended
N/A
N/A
N/A
N/A
50i, 80i, 90i
Diaphot, Labophot, TMF
E400, E600, E800
SMZ800,SMZ1500
TE2000, all other “TE”
TS100
810-00030X
810-00030X*
810-00030X
810-00030X
810-00030X
810-00030X*
810-10030X
810-10030X*
810-10030X
810-10030X
810-10030X
810-10093X
TBD
TBD
Not recommended
TBD
TBD
TBD
Microscope Model
Notes:
* Additional fittings and/or specific configuration from microscope manufacturer may be required.
‡ May not be suitable for some applications, demo before purchase recommended.
X-Cite and microscope models in italics have been discontinued.
June 2021
MG
X-Cite® illuminators have been qualified for the following microscopes:
Light Guide Adaptor
For: X-Cite 120Q series, XLED1,
110LED, TURBO, XYLIS, NOVEM
Also: 200DC, exacte, FIRE
Direct Coupling Flange
For: X-Cite mini+
Also: 120LED, 120LEDmini
Direct Coupling Flange
For: X-Cite 120LEDBoost
OLYMPUS
BX2 series: BX51WI, BX61WI
BX3 series: BX43, BX46, BX53, BX63
CKX53
IX3 series (w/ RFA)
IX3 series (w/ RFA-L)
MVX10
SZX7, 10, 16
810-00032X
810-00032X
810-00032X
810-00046X
810-00046X
810-00046X
810-00032X
810-10032X
810-10032X
810-10032X
810-10031X
810-10032X
810-10031X
810-10032X
810-10032X
810-10032X
TBD
Not recommended
810-10032X-01
TBD
TBD
AX70
BX series: BX50, BX60
BX2 series: BX41, BX51,BX61
CKX41
CK40
CX41
IX series: IX50, IX70
IX2 series: IX51, IX71, IX81
SZX12
810-00032X
810-00032X
810-00032X
810-00032X
810-00032X
810-00077X
810-00031X
810-00031X
810-00032X
TBD
810-10032X
810-10032X
810-10032X
TBD
TBD
810-10031X
810-10031X
810-10032X
TBD
810-10032X
810-10032X
TBD
TBD
TBD
TBD
TBD
TBD
Microscope Model
Notes:
X-Cite and microscope models in italics have been discontinued.
June 2021
MG
X-Cite® illuminators have been qualified for the following microscopes:
Light Guide Adaptor
For: X-Cite 120Q series, XLED1,
110LED, TURBO, XYLIS, NOVEM
Also: 200DC, exacte, FIRE
Direct Coupling Flange
For: X-Cite mini+
Also: 120LED, 120LEDmini
Direct Coupling Flange
For: X-Cite 120LEDBoost
ACCU-SCOPE
EXC-400
EXC-500
EXI-310
EXI-600
TBD
TBD
TBD
810-00022X
810-10096X
810-10032X
810-10032X
810-10022X
TBD
TBD
TBD
TBD
MOTIC
AE31
BA400
810-00055
810-00055
N/A
N/A
N/A
N/A
Microscope Model
Notes:
X-Cite and microscope models in italics have been discontinued.
June 2021
MG