SM8001

SM8001

  • 厂商:

    IFM(易福门)

  • 封装:

  • 描述:

    MAGNETIC-INDUCTIVE FLOW METER, 4

  • 数据手册
  • 价格&库存
SM8001 数据手册
SM8001 Magnetic-inductive flow meter SMR11GGXFRKG/US-100 Product characteristics Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Measuring range 6...1584 gph Process connection 0.1...26.4 gpm threaded connection G 1 DN25 flat seal Application Special feature Gold-plated contacts Application totaliser function; for industrial applications Installation connection to pipe by means of an adapter Media conductive liquids; water; hydrous media Note on media conductivity: ≥ 20 µS/cm viscosity: < 70 mm²/s (40 °C) Medium temperature [°F] 14...158 Pressure rating [bar] 16 Pressure rating [psi] 232 MAWP (for applications according to CRN) [bar] 11.2 Electrical data Operating voltage Current consumption [V] [mA] Protection class 95; (24 V) III Reverse polarity protection Power-on delay time 18...30 DC; (to SELV/PELV) yes [s] 5 Inputs / outputs Number of inputs and outputs Number of digital outputs: 2; Number of analogue outputs: 1 Inputs Inputs counter reset ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM8001-03 — 13.04.2023 — SM8001 Magnetic-inductive flow meter SMR11GGXFRKG/US-100 Outputs Total number of outputs 2 Output signal switching signal; analogue signal; pulse signal; IO-Link; (configurable) Electrical design PNP/NPN Number of digital outputs 2 Output function normally open / normally closed; (parameterisable) Max. voltage drop switching output DC [V] Permanent current rating of switching output DC [mA] 2 200 Number of analogue outputs Analogue current output Max. load 1 [mA] 4...20; (scalable) [Ω] 500 Analogue voltage output [V] 0...10; (scalable) Min. load resistance [Ω] 2000 Pulse output flow rate meter Short-circuit protection yes Type of short-circuit protection pulsed Overload protection yes Measuring/setting range Measuring range 6...1584 gph 0.1...26.4 gpm Display range -1902...1902 gph -31.7...31.7 gpm Resolution 2 gph 0.05 gpm Set point SP 14...1586 gph 0.25...26.4 gpm Reset point rP 6...1578 gph 0.1...26.25 gpm Analogue start point ASP 0...1272 gph 0...21.2 gpm Analogue end point AEP 312...1586 gph 5.2...26.4 gpm In steps of 2 gph 0.05 gpm Volumetric flow quantity monitoring Pulse value Pulse length 0.01...100 000 000 gal [s] 0,0025...2 Measuring range [°F] -4...176 Resolution [°F] 0.5 Set point SP [°F] -2.5...176 Reset point rP [°F] -3.5...175 Analogue start point [°F] -4...140.5 Analogue end point [°F] 31.5...176 In steps of [°F] 0.5 Temperature monitoring Accuracy / deviations Flow monitoring Accuracy (in the measuring range) Repeatability ± (0,8 % MW + 0,5 % MEW) ± 0,2% MEW ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM8001-03 — 13.04.2023 — SM8001 Magnetic-inductive flow meter SMR11GGXFRKG/US-100 Temperature monitoring Accuracy [K] ± 2,5 (Q > 0,26 gpm) Response time [s] 0.15; (dAP = 0, T19) Delay time programmable dS, dr [s] Damping process value dAP [s] 0...5 [s] T09 = 20 (Q > 0,26 gpm) Response times Flow monitoring 0...50 Temperature monitoring Dynamic response T05 / T09 Software / programming Parameter setting options Flow monitoring; quantity meter; Preset counter; Temperature monitoring; hysteresis / window; normally open / normally closed; switching logic; current/ voltage/pulse output; start-up delay; display can be deactivated; Display unit Interfaces Communication interface IO-Link Transmission type COM2 (38,4 kBaud) IO-Link revision 1.1 SDCI standard IEC 61131-9 Profiles Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis SIO mode yes Required master port type A Process data analogue 3 Process data binary 2 Min. process cycle time [ms] Supported DeviceIDs 5 Type of operation DeviceID Default 576 Operating conditions Ambient temperature [°F] 14...140 Storage temperature [°F] -13...176 Protection IP 67 Tests / approvals EMC DIN EN 60947-5-9 Shock resistance DIN IEC 68-2-27 Vibration resistance MTTF DIN IEC 68-2-6 [years] Pressure Equipment Directive 20 g (11 ms) 5 g (10...2000 Hz) 145 Sound engineering practice; can be used for group 2 fluids; group 1 fluids on request Mechanical data Weight [g] Materials Materials (wetted parts) Process connection 26 stainless steel (1.4404 / 316L); PBT-GF20; PC; FKM; TPE stainless steel (1.4404 / 316L); PEEK; FKM threaded connection G 1 DN25 flat seal ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM8001-03 — 13.04.2023 — SM8001 Magnetic-inductive flow meter SMR11GGXFRKG/US-100 Displays / operating elements Display Display unit 6 x LED, green (gpm, gph, gal, °F, 10³, 1000 x 10³) switching status 2 x LED, yellow measured values alphanumeric display, 4-digit programming alphanumeric display, 4-digit Remarks Remarks MW = measured value MEW = Final value of the measuring range Pack quantity 1 pcs. Electrical connection Connector: 1 x M12; coding: A; Contacts: gold-plated Connection OUT1: OUT2: BK = BN = BU = WH = colours to DIN EN 60947-5-2 switching output volumetric flow quantity monitoring Pulse output quantity meter signal output Preset counter IO-Link switching output volumetric flow quantity monitoring switching output Temperature monitoring analogue output volumetric flow quantity monitoring analogue output Temperature monitoring input counter reset Core colours : black brown blue white ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM8001-03 — 13.04.2023 — SM8001 Magnetic-inductive flow meter SMR11GGXFRKG/US-100 Diagrams and graphs Pressure loss dP Pressure loss Q volumetric flow quantity ifm electronic gmbh • Friedrichstraße 1 • 45128 Essen — We reserve the right to make technical alterations without prior notice. — EN-GB — SM8001-03 — 13.04.2023 —
SM8001 价格&库存

很抱歉,暂时无法提供与“SM8001”相匹配的价格&库存,您可以联系我们找货

免费人工找货