0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
70G-IDC24S

70G-IDC24S

  • 厂商:

    GRAYHILL

  • 封装:

  • 描述:

    70G-IDC24S - Contact Closure DC Input Modules - Grayhill, Inc

  • 数据手册
  • 价格&库存
70G-IDC24S 数据手册
Contact Closure DC Input Modules FEATURES • Wire Dry Contact Sensors Directly to Module, Eliminate External Power Supply • 2500 Vac Isolation • Built-In Status LED • UL, CSA, CE Mark, TÜV Certified (TÜV not available on OpenLine®) • Simplifies Field Wiring 70L-IDL 70G-IDC CIRCUITRY: Negative True Logic G5 +1 VDC I/O MODULE PIN # + 1 1 FILTER OPTICAL ISOLATION OpenLine ® TYPICAL WIRING FOR MODULE 0 6 A 7 HYSTERESIS INPUT DEVICE 2 Vcc CH. A STATUS GND TRANSFORMER ISOLATION – 2 CONTACT DEBOUNCE 5 2 + +VCC 3 OUTPUT 4 GROUND 5 10KΩ OUTPUT DRIVER CIRCUIT + DC SUPPLY INPUT DEVICE 3 3 FILTER OPTICAL ISOLATION B HYSTERESIS 8 CH. B STATUS – TERMINAL BLOCK # 4 BASE OR RACK 4 – 0Ω 9 MODULE ID MODULE SPECIFICATIONS: Specifications apply over operating temperature range unless noted otherwise. OpenLine® Vibration: .15mm, 10 to 50 Hz per IEC68-2-6 Mechanical Shock: 50 G's, 0.5 mS, sinsoidal per IEC68-2-27 Storage Temperature Range: -40°C to +100°C Operating Temperature Range: -40°C to +85°C per MIL–STD–202, Method 213, Condition F Storage Temperature Range: -40°C to +125°C Operating Temperature Range: 0°C to +60°C All Modules Output Specifications Output Current Range: 1-50 mA Breakdown Voltage: 50 Vdc minimum Off State Leakage Current: 1 µA maximum On State Voltage Drop: 0.45 Vdc at 50 mA maximum I/O Modules G5 Vibration: 20 G's peak or .06" double amplitude 10–2000 Hz per MIL–STD–202, Method 204, Condition D Mechanical Shock: 1500 G's 0.5 mS half-sine Available from your local Grayhill Distributor. For prices and discounts, contact a local Sales Office, an authorized local Distributor or Grayhill. General Characteristics Isolation Voltage Field to Logic: 2500 Vac (rms) minimum SPECIFICATIONS: By Part Number Type/Function G5, Dry Contact Specifications Maximum Dry Contact Voltage Rating Minimum Dry Contact Current Rating Maximum Turn-on Time Maximum Turn-off Time Contact Resistance (Output Low) Contact Resistance (Output High) Nominal Logic Voltage (Vcc) Logic Voltage Range: G5 Max. Logic Supply Current @ Nominal Vcc 1 Grayhill Part Number 70L-IDC5S Units Vdc mA mSec mSec Ω Ω Vdc Vdc mA 25 5 10 10 ≤ 1.25K 25K 5 4.5-5.5 1201 25 5 3.0 3.0 ≤ 1.25K 25K 5 4.5-6 41 25 5 3.0 3.0 ≤ 1.25K 25K 24 15-30 41 70G-IDC5S 70G-IDC24S WHEN BOTH CHANNELS ARE ACTIVATED I/O 20 G rayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com Analog I/O Modules Engineering Information and Selection Chart ANALOG I/O MODULES Analog output modules are used in proportional control of devices such as valves, motors, and heaters. Analog input modules are used in data gathering and proportional control applications. All modules are potted for industrial environments. They operate under high vibration (IEC68-2-6; 0.15 mm/sec2 at 10150Hz) mechanical shock (IEC68-2-27; 11 mS, sinusoidal 30 gS) and high relative humidity (IEC68-2-3; 5-95% non-condensing). They feature a high level of noise immunity and accuracy. All models provide isolation from field to logic, field to power supply and module to module. 12-bit value that is right justified and packed in a 16-bit word that represents the equivalent analog value sensed. OpenLine® thermocouple inputs linearize the thermocouple reading and returns degrees to the controller. Start Pulse: High for 6.4 µS Min., then low for 3.2 µS Data Packet: Each bit is 12.8 µS long. High for first 3.2 µS of the bit. Middle 6.4 µS determines the value of the data bit (High = 1, Low = 0). Low for last 3.2 µS of the bit. Stop Pulse: Low for 500 µS minimum Times shown are ± 10%, except minimums. SERIAL DATA FORMAT** Openline® Analog Output For analog output modules, the output of these modules is zero scale on power up, then it is the analog equivalent of the 12-bit value sent to the module over the communication lines. G5 Analog Input G5 voltage or current input modules are actually frequency converters. The input to these modules is a signal from a sensor. The output from these modules is a squarewave whose frequency varies linearly from 14.4 to 72 KHz and is proportional to the input signal. The controller must be able to measure this frequency and convert it back to a signal level. G5 thermocouple modules pass through the thermocouple reading and do not linearize the signal. Linearization must take place within the controller. G5 Analog Output The output (voltage or current level) of these modules varies proportionally to the 12-bit serial data string sent to them by a control circuit. The data string is typically 213.2 µSec. long as detailed in Figure 1. Once a data string is received, the output is set and remains constant until another data string is sent. Therefore, the output level of the module could be changed almost 4700 times a second. For more information on programming Grayhill analog output modules, request a copy of Bulletin No. 581. OpenLine® Analog OpenLine a nalog modules communicate serially with the controller. Each module has a separate transmit and receive line that operates at 115,200 baud with no parity bits, 8 data bits, and 1 stop bit (115.2K,N,8,1). The command structure and responses for all modules are detailed in Bulletin No. 743. Each module has a microcontroller and non-volatile serial EEPROM memory. The calibration data is stored within the EEPROM, and may be changed using the appropriate commands and the 70L-PROG field calibration unit. The software provided with the calibration unit communicates with the modules through the serial port of a PC. Calibration equipment is not provided. ® Agency Approvals OpenLine® analog modules are EN50082-2 and EN50081-2 compliant and meet the requirements of 89/336/EEC EMC directive. They are also EN60950 (61010-1) compliant. Meeting these requirements allows the modules to bear the CE mark. Additionally, the modules are CSA certified to CSA 22.2 No. 14-95M and CSA 22.2 No. 213-M1987 Class I, Div. 2 Groups A, B, C and D and are UL recognized to UL 508. START 9.6µS 12 BIT DATA 153.6µS END 500µS OpenLine® Analog Input Modules Upon request, analog input modules return a Figure 1 PART NUMBER EXPLANATION: Analog I/O Modules Module Type 73G = Analog Module, G5 Package, Single Channel 73L = Analog Module, OpenLine® Package, Dual Channel Function OV = Analog Output, Voltage OI = Analog Output, Current IV = Analog Input, Voltage Suffix Analog Modules: II = Analog Input, Current IT = Analog Input, Temperature I/O Modules 73G-IV50M 5 5B 1 CJ CK CR CT = = = = = = = 0–5 Vdc -5–5 Vdc 0–1 Vdc J type TC K type TC R type TC T type TC 10 = 0 - 10 Vdc 10B = -10 - 10 Vdc 020 = 0 to 20 mA 420 = 4 to 20 mA 5000 = 0 to 5 A AC120 = 28 to 140 Vac AC240 = 28 to 280 Vac 50M 100M R100 R3100 R4100 = 0–50 mV = 0–100 mV = RTD = 3 Wire RTD = 4 Wire RTD Grayhill, Inc. • 561 Hillgrove Avenue • LaGrange, Illinois 60525-5997 • USA • Phone: 708-354-1040 • Fax: 708-354-2820 • www.grayhill.com I/O 21
70G-IDC24S 价格&库存

很抱歉,暂时无法提供与“70G-IDC24S”相匹配的价格&库存,您可以联系我们找货

免费人工找货