Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
Related Information
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
For Gas
■■General terms and conditions.............. F-3
■■Glossary of terms........................ P.1563~
■■Korea’s S-mark.............................. P.1602
■■Selection guide.............................. P.699~
■■General precautions...................... P.1566
Ver.2
Recognition
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Certified
[DP-101(A)/102(A) only]
PARTICULAR
USE SENSORS
* Passed the UL 991 Environment Test
SENSOR
OPTIONS
* UL 61010C-1 compatible, Passed the UL 991
Environment Test based on SEMI S2-0200.
[Category applicable for semiconductor
manufacturing: TWW2, Process Equipment]
[Applicable standards: UL 61010C-1]
[Additional test / evaluation standards as per intended
use: UL 991, SEMI S2-0200]
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
panasonic.net/id/pidsx/global
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Digital
Auto reference With analog
output
Dual 3-color display makes operation easier!
Achieved further efficiency with 4 upgrades, keeping the same operability
UPGRADE 1
Superior visibility
Improved visibility in Digital Display
Improvements to the digital display deliver a wide
viewing angle along with increased clarity. The display
pressure range and set pressure range have also been
increased.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Old DP-100 series
New DP-100 series
Flow
DP-0
DP-100
DP-M
UPGRADE 2
Long-distance transmission of analog output
Addition of analog current output capability to multifunctional models
Users can now select either voltage output or current output as analog output according to their application.
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
APPLICATIONS
Confirming suction of electronic component
714
FIBER
SENSORS
Confirming reference pressure
Air-leak test for PET bottles
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
UPGRADE 3
Reduced environmental impact
14 % lower power consumption (during normal operation)
Thanks to a redesign of its circuitry, power consumption
of the low-power-consumption DP-100 series during
normal operation has been reduced by 14 %. The
display is shut off entirely during ECO / FULL mode
operation for power savings of up to 50 % compared
to normal operation, and display brightness is lowered
during ECO / STD mode operation for power savings of
up to 30 % compared to normal operation.
14 % lower
after update
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Old DP-100 series New DP-100 series
840 mW (normal operation) 720 mW (normal operation)
Up to 50 % lower
in ECO mode
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
Normal operation ECO / FULL operation
720 mW
360 mW
ENERGY
MANAGEMENT
SOLUTIONS
UPGRADE 4
FA COMPONENTS
Enhanced power circuitry
Addition of a reverse polarity protection circuit to the transistor output circuit
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
To prevent from breakage due to miswiring.
“Current value” and “threshold value” can be checked at the same time!
Dual display allows direct setting of threshold value
Equipped with a 30 mm 1.181 in square compact-sized dual display. The
current value and the threshold value can be checked at the same time, so
the threshold value can be set and checked smoothly without switching to
another screen mode. ON/OFF operations still continue while the threshold
values are being set, so setting to the same sensitivity as dial control-type
sensors is possible. Key lock function is equipped as well.
Current
value
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
Threshold
value
715
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Dual Display Digital Pressure Sensor
3-color display (Red, Green, Orange)
Readable digital display!
The main display changes color in line with changes
in the status of output ON/OFF operation, and it also
changes color while setting is in progress. The sensor
status can therefore be understood easily, and operating
errors can be reduced.
Alphanumeric indication in 12 segments is used. This
improved visual checking.
Main
Display
OFF: Green (or Red)
STATIC
CONTROL
DEVICES
LASER
MARKERS
ON: Red (or Green)
SET: Orange
During normal operation
During setting
BASIC PERFORMANCE
All models in the line-up are compound pressure types
High performance accomplished Low pressure type
No sensor settings are required to switch between positive pressure and negative
pressure, so that the number of registered part numbers can be decreased.
The low pressure type displays measurements in 0.1 kPa
at a resolution of 1/2,000 and has a response time of 2.5
ms (variable up to 5,000 ms), ±0.5 % F.S. temperature
characteristics and ±0.1 % F.S. repeatability, giving it
high performance.
Ideal for applications such
as suction.
No mis-operations due to
vacuum breakdown occur.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
DP-100 SERIES Ver.2
–100 kPa
For low
pressure
0 kPa
Ideal for applications such as
checking reference pressure.
Can also be used for simple
suction.
100 kPa
DP-101□
1 MPa
For high
pressure
DP-102□
Resolution: 1/2,000
Response time: 2.5 ms
Temperature characteristics: ±0.5 % F.S.
Repeatability: ±0.1 % F.S.
Displays measurements in 0.1 kPa
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
FUNCTIONS
Copy function reduces man-hours and human error
Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data
to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when
machinery design are changed, there would be less change in work orders.
Details transmitted
Copying via wiring
Master sensor
Power supply
+V
+V
0V
0V
Comparative output 1
Comparative output 1
Comparative output 2
Comparative output 2
Details received
Slave sensor
Detail
s cop
ied
Note: Settings cannot be copied from the new version (Ver. 2) to the old version.
However, settings can be copied from the old version to the new version (Ver. 2).
Flow
DP-0
DP-100
DP-M
The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use
The setting levels are clearly separated into “RUN mode”
for operation settings that are carried out daily, “MENU
SETTING mode” for basic settings, and “PRO mode”
for special and detailed setting. These make setting
operations easy to understand and easy to carry out.
Simple setting
RUN mode
MENU SETTING mode
Special and
detailed setting
PRO mode
RUN mode
Settings such as threshold value
adjustment and key lock operation
can be carried out while the sensor
is operating.
MENU SETTING mode
Basic settings such as output mode
setting and NO/NC switching can be
carried out.
PRO mode
High-level function settings such as
hysteresis adjustment and the copy
function can be carried out.
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
FUNCTIONS
Equipped with independent dual output and three output modes
Equipped with two independent comparative outputs,
and separate sensing modes can be selected for each
of them. Since there are two comparative outputs, one
of the comparative outputs can even be used for alarm
output. In addition, output, which is not being used, can
be disabled.
1
Pressure
Suction checking
Comparative output
0
ON
OFF
Hysteresis mode
Vacuum breakdown checking
0 kPa
P-2
Reference pressure alarm output is possible during reference pressure checking!
ON
Reference
pressure
checking
Comparative output 1
Hysteresis mode
OFF
Alarm output
ON
Comparative output 2
EASY mode
OFF
H (Hysteresis)
Lo
0
ON
Comparative output
OFF
Note: “
” or “
output 1, and “
3
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
Hi
H: 1 digit or more
” appears in the sub display for comparative
” or “
” appears for comparative output 2.
Window comparator mode
This mode is used for setting comparative output ON
and OFF at pressures within the setting range.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
Lo-1
Hi-1
Pressure
0 kPa
H: Fixed
This mode is used for setting comparative output hysteresis
to the desired level and for carrying out ON/OFF control.
P-1
FIBER
SENSORS
AREA
SENSORS
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “
”appears in the sub display for comparative output 1, and
“
” appears for comparative output 2.
Pressure
–100 kPa
H (Hysteresis)
P
2
ON
Comparative output 2
EASY mode
OFF
EASY mode
This mode is used for comparative output ON/OFF control.
Vacuum breakdown can also be notified during suction applications!
ON
Comparative output 1
EASY mode
OFF
Standard type
716
P-2
H (Hysteresis)
Hi
H (Hysteresis)
Lo
0
ON
Comparative output
OFF
H: Fixed
Notes: 1) Hysteresis can be fixed to one of eight different levels.
2) “
” or “
” appears in the sub display for comparative
output 1, and “
” or “
” appears for comparative output 2.
Possible to switch over analog output and external input
Multi-function type
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/
remote zero-adjustment) is available. It complies a wide range of applications.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Comparative output
Selection
Multi-function type
Analog output
or
External input
is lighting.
Voltage Low pressure type: 1 to 5 V,
High pressure type: 0.6 to 5 V
Current Low pressure type: 4 to 20 mA,
High pressure type: 2.4 to 20 mA
Auto-reference/remote zero-adjust
Flow
DP-0
DP-100
DP-M
717
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Dual Display Digital Pressure Sensor
FUNCTIONS
Equipped with auto-reference/remote zero-adjustment functions. More precise pressure management is achieved with a minimum of effort Multi-function type
If the reference pressure of the device changes, two functions are selectable.
One is auto-reference function, which partially shift the comparative output
judgment level by the amount that the reference pressure shifts. The other
is remote zero-adjustment function, which can reset the display value to zero
via external input. These functions are ideal for places where the reference
pressure fluctuates wildly, or where fine settings are required.
With auto-reference function applied
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
Sets the absolute threshold level
Auto-reference input
The display remains at “30” and
only the threshold level is changed.
30
LASER
MARKERS
PLC
HUMAN MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
Sets the absolute threshold level
Remote zero-adjustment input
The display is forced to “0”, and only the
filling pressure drop range is displayed.
30
OK
25
20
Threshold level after applying
auto-reference input
15
0
–5
25
OK
20
Threshold level after applying
remote zero-adjustment input
15
Threshold level before applying
auto-reference input
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
With remote zero-adjustment function applied
Comparative output: Window comparator mode
Hi-1…0, Lo-1…–5
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
DP-100 SERIES Ver.2
Threshold level before applying
remote zero-adjustment input
Trial 1
Pressure 0
–5
Trial 1
Pressure 0
Auto-reference input value…
Time
When auto-reference input is applied, the reference pressure “30”
is added to the threshold level. If the reference pressure changes
to “20” or “40”, the auto-reference input compensates for this
every time by changing the threshold level, so any variation in
the filling pressure can be ignored.
–5
Displayed when remote zero-adjustment
input is applied…
Time
When remote zero-adjustment input is applied, the reference
pressure is forced to “0”. If the reference pressure changes to
“20” or “40”, the remote zero-adjustment input adjusts the
reference pressure to “0” every time the reference pressure
changes, so any variation in the filling pressure can be ignored.
Sub display can be customized
Setting details can be recognized at a glance
The sub display can be set to indicate any other desired
values or letters apart from the threshold value. This
eliminates the need for tasks such as affixing a label to
the device to indicate the normal pressure value.
The DP-100 setting details appear in the digital display.
Because the settings are in numeric form that can be
easily understood, it is useful such as when receiving
technical support by telephone.
UV CURING
SYSTEMS
2nd digit: Setting status for
comparative output 2
1st digit: Setting status for
comparative output 1
3rd digit: Threshold value setting
4th digit: Display color setting
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
5th digit: Response time
setting
6th digit: Display unit setting
DP-0
DP-100
DP-M
8th digit: ECO mode setting
7th digit: Display refresh rate setting
Peak hold and Bottom hold functions
Energy-saving design! Equipped with an ECO mode
The peak values and bottom values for fluctuating
pressures can be displayed using the dual display.
This mode lowers the display luminance to cut power
consumption by approximately 30 %. The displays can
also be turned off completely to achieve a power saving
of approximately 50 %.
Power consumption
Normal
Approx.
Power consumption
Approx.
ECO-STD 30 % less
ECO-FULL 50 % less
Current consumption for
24 V power supply: 20 mA or less
Current consumption for
24 V power supply: 15 mA or less
Blinks alternately
Current consumption for
24 V power supply: 30 mA or less
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
MOUNTING
FIBER
SENSORS
Tight installation to panels is possible
LASER
SENSORS
An exclusive mounting bracket that is suitable for 1 to 6
mm 0.039 to 0.236 in panel thickness is available.
Tight installation is possible
Neat and
space
saving
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Front protection
cover available
MS-DP1-3
AREA
SENSORS
A single mounting hole!
An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available
• MS-DP1-5
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE SENSORS
Space savings can also be achieved even when an L-shaped mounting bracket is used.
• MS-DP1-1
718
Tight installation is possible
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
Ceiling mounting
Floor mounting
Rear mounting
Positioning bosses for easier
mounting bracket installation
PLC
HUMAN MACHINE
INTERFACES
Cable can be connected with one-touch
Types without connector attached
cable are also available
Connector attached cable (2 m
6.562 ft), as an accessory, can be
connected easily with one-touch
connection.
Commercially-available connectors can be used for
cable connections. Cables in required length can
be used, so this contributes to reduction in waste of
unwanted cables.
DP-10□-J
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Environmentally
friendly
* Connection cable
* Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available.
Commercially-available
parts can be used!
* Refer to p.721 for recommended commercially-available connectors.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
719
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
VARIETIES
DP-10□-M
Short pressure port type is lightweight and takes up little space
Compact size with a depth of only 30 mm 1.181 in, so
that it can easily fit into narrow spaces.
Further, 10 g lighter than standard types. This reduces
the loads on movable parts such as robot arms.
Standard type
M5 female thread + R 1/8 male thread
Elbow joint
Short pressure
port type DP-10□-M(-P)
SAFETY LIGHT
CURTAINS /
SAFETY COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Short pressure port type
DP-10□-M(-P)
Shortened to
12.5 mm 0.492 in !
Light weight
30g approx.
PARTICULAR
USE SENSORS
SENSOR
OPTIONS
30 mm
1.181 in
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
M5 female thread
[Material: Stainless steel (SUS)]
*T
he illustration shows connection using an elbow joint.
The elbow joint is sold separately.
M8 plug-in connector types are also available (Only for Europe)
STATIC
CONTROL
DEVICES
Mating cable
CN-24A-C2 (cable length 2 m 6.562 ft)
CN-24A-C5 (cable length 5 m 16.404 ft)
LASER
MARKERS
DP-11□-E-P-J
M8 connector
PLC
HUMAN MACHINE
INTERFACES
G 1/8 male thread
M5 female thread
ENERGY
MANAGEMENT
SOLUTIONS
FA COMPONENTS
MACHINE VISION
SYSTEMS
UV CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
Flat installation on the wall by shifting the direction
For short pressure port type
of the pressure port
Rc1/8 conversion bushing is available. Compatible
with conventional model For short pressure port type
By mounting the flat
attachment to DP-10□-M(-P),
pressure port and cable can
now be pulled out in downward,
left or right directions. Flat
mounting on surfaces such as
the wall is made possible.
By equipping the push-in converter with DP-10□-M(-P),
pressure port can be converted from M5 female thread
to Rc1/8 female thread.
Bore diameter conversion to the DP2 / DP3 series is
possible.
Conventional model DP2 / DP3
series can be switched over to
DP-100 series.
Conventional model
M5 female thread
Rc1/8 female thread
Flat attachment
MS-DP1-F□
DP-0
20 mm
0.787 in pitch
DP-100
DP-M
Model No.
3 possible directions to mount
20 mm
0.787 in pitch
Pressure port
MS-DP1-FM
M5 female thread
MS-DP1-FR
Rc1/8 female thread
MS-DP1-FN
NPT1/8 female thread
MS-DP1-FE
G1/8 female thread
Conversion bushing
MS-DP1-7
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
ORDER GUIDE
720
FIBER
SENSORS
LASER
SENSORS
Type
Asia
Standard
Multi-function
M8 plug-in connector type
Europe
Multi-function
North America
Standard pressure port type
Standard
Standard
Multi-function
Appearance
Model No.
For low pressure
−100.0 to +100.0 kPa
DP-101
For high pressure
−0.100 to +1.000 MPa
DP-102
For low pressure
−100.0 to +100.0 kPa
DP-101A
For high pressure
−0.100 to +1.000 MPa
DP-102A
For low pressure
−100.0 to +100.0 kPa
DP-101-E-P
For high pressure
−0.100 to +1.000 MPa
For low pressure
−100.0 to +100.0 kPa
For high pressure
−0.100 to +1.000 MPa
For low pressure
−100.0 to +100.0 kPa
DP-111-E-P-J
For high pressure
−0.100 to +1.000 MPa
DP-112-E-P-J
For low pressure
−100.0 to +100.0 kPa
For high pressure
−0.100 to +1.000 MPa
For low pressure
−100.0 to +100.0 kPa
Standard
For high pressure
For low pressure
Multi-function
For high pressure
* CN-14A-C2
Connector attached
cable 2 m 6.562 ft
is attached.
Excluding M8 plug-in
connector type
(
(
−0.100 to +1.000 MPa
)
)
−100.0 to +100.0 kPa
−0.100 to +1.000 MPa
For low pressure
−100.0 to +100.0 kPa
For high pressure
−0.100 to +1.000 MPa
Standard
Asia
Short pressure port type
Rated pressure range
For low pressure
−100.0 to +100.0 kPa
Multi-function
For high pressure
−0.100 to +1.000 MPa
Pressure port
Comparative output
M5 female thread
+
NPN open-collector transistor
R 1/8
male thread
M5 female thread
DP-102-E-P
+
PNP open-collector transistor
G 1/8
DP-101A-E-P
male thread
DP-102A-E-P
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
M5 female thread
+
PNP open-collector transistor
G 1/8
DP-111A-E-P-J
male thread
PARTICULAR
USE
SENSORS
DP-101-N
NPN open-collector transistor
DP-101-N-P
PNP open-collector transistor
SIMPLE
WIRE-SAVING
UNITS
DP-112A-E-P-J
DP-102-N
NPN open-collector transistor
M5 female thread
PNP open-collector transistor
DP-102-N-P
+
NPT 1/8
NPN open-collector transistor
DP-101A-N
male thread
PNP open-collector transistor
DP-101A-N-P
DP-102A-N
NPN open-collector transistor
DP-102A-N-P
PNP open-collector transistor
DP-101-M
NPN open-collector transistor
DP-101-M-P
PNP open-collector transistor
DP-102-M
NPN open-collector transistor
DP-102-M-P
PNP open-collector transistor
DP-101A-M
M5 female thread
NPN open-collector transistor
DP-101A-M-P
PNP open-collector transistor
DP-102A-M
NPN open-collector transistor
DP-102A-M-P
PNP open-collector transistor
Type without connector attached cable
SENSOR
OPTIONS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Type without connector attached cable CN-14A-C2 is available.
When ordering this type, suffix “-J” to the Model No. (Excluding M8 plug-in connector type and short pressure port type)
(e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J”
Accessory
• CN-14A-C2
(Connector attached cable 2 m 6.562 ft)
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
721
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
OPTIONS
FIBER
SENSORS
LASER
SENSORS
Designation
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Model No.
Connector
attached cable
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Connector
attached cable
Bending-resistant
cable
(
)
M8 connector
attached cable
CN-14A-C1
CN-14A-C2 (Note)
CN-14A-C3
CN-14A-C5
CN-14A-R-C1
CN-14A-R-C2
CN-14A-R-C3
CN-14A-R-C5
Length: 1 m 3.281 ft
CN-24A-C2
Length: 2 m 6.562 ft
CN-24A-C5
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Length: 1 m 3.281 ft
Length: 3 m 9.843 ft
Length: 5 m 16.404 ft
Set of 10 housings and 40 contacts
MS-DP1-1
MS-DP1-5
Allows sensors to be installed on the wall. Multiple sensors
can also be mounted closely.
MS-DP1-2
Allows installation to panels with thickness of 1 to 6 mm 0.039
to 0.236 in. Multiple sensors can also be mounted closely.
MS-DP1-4
Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed
set-up, please use panel mounting bracket MS-DP1-2 for panel mounting.
MS-DP1-3
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket MS-DP1-2)
DPX-04
Protects the adjustment surfaces of sensors.
(Can be attached when using the panel mounting bracket MS-DP1-4)
Conversion
bushing
MS-DP1-7
By equipping with DP-10□-M(-P), pressure port can be converted to
Rc1/8 female thread. Replacement from DP2 / DP3 series is possible.
MS-DP1-FM
MS-DP1-FR
MS-DP1-FN
MS-DP1-FE
M5 female thread
Flat
attachment
Sensor
mounting
bracket
Panel mounting
bracket
Front protection
cover
M8 connector attached cable
• CN-24A-C□
For M8 plug-in connector type
The connector on one end
Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in
Allows sensors to be installed on the flooring or ceiling.
Multiple sensors can also be mounted closely.
For DP-10□-M(-P)
Pressure port and cable can now be
pulled out in downward, left or right
1
NPT /8 female thread directions. Flat mounting on surfaces
such as the wall is made possible.
G1/8 female thread
Rc1/8 female thread
Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series.
(Excluding M8 plug-in connector type).
31.4
1.236
• MS-DP1-2
• MS-DP1-3
• MS-DP1-4
Front protection cover
DPX-04 (optional)
can be installed on
MS-DP1-4.
Front protection cover
MS-DP1-3
Sensor mounting bracket
• MS-DP1-1
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-1
(
)
Sensor mounting
bracket
MS-DP1-1
• MS-DP1-5
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for
MS-DP1-5
(
DP2 / DP3
DP
2-2
0
ñ101
.3kP
a
OUT
1
OUT
2
0-AD
J
MOD
E
Remove
Insert
Panel mounting bracket
MS-DP1-2
• MS-DP1-FM
(Unit: mm in)
)
Sensor mounting
bracket
MS-DP1-5
Remove
DP-100
Flat attachment
ø4
ø0.157
ø9
ø0.354
Panel mounting bracket, Front protection cover
Flow
DP-M
0.2 mm2 4-core bending-resistant cabtyre
cable with connector on one end
Cable outer diameter: ø3.7 mm ø0.146 in
Length: 2 m 6.562 ft
CN-14A
Connector
Pressure/
Head-separated
DP-100
• CN-14A-C□
• CN-14A-R-C□
0.2 mm2 4-core cabtyre cable with
connector on one end
Cable outer diameter: ø3.7 mm ø0.146 in
Length: 2 m 6.562 ft
Pressure/
Digital Display
DP-0
Connector attached cable
Description
Mounting holes
for DP2 / DP3 series
can be used as is.
Conversion bushing
• MS-DP1-7
M5 female
thread
Rc1/8 female
thread
Panel mounting bracket MS-DP1-4
• MS-DP1-FR
• MS-DP1-FN
• MS-DP1-FE
Conversion bushing
MS-DP1-7
Recommended connector
Net weight:
MS-DP1-FM 15g approx.
MS-DP1-FR/FN/FE 25g approx.
Two M3 (length 8 mm 0.315 in) screws,
two M4 (length 20 mm 0.787 in) screws
are attached.
Contact: SPHD-001T-P0.5, Housing: PAP-04V-S
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the
recommended products.
Recommended crimping tool
Model No.: YC-610R
(Manufactured by J.S.T. Mfg. Co., Ltd.)
Note: Contact the manufacturer for details of the
recommended products.
Recommended connector (e-CON)
Applicable connector: 37104-3122-000 FL
(Manufactured by 3M Japan Limited)
Note: Contact the manufacturer for details of the
recommended products.
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
722
SPECIFICATIONS
Standard
Model No.
Type
Item
FIBER
SENSORS
For low pressure
DP-101(-M)(-P)
DP-101-E-P
DP-111-E-P-J
DP-101-N(-P)
Asia (Note 2)
Europe
M8 plug-in connector type
North America (Note 2)
For high pressure
DP-102(-M)(-P)
DP-102-E-P
DP-112-E-P-J
DP-102-N(-P)
CE marking directive compliance
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Gauge pressure
Rated pressure range
−100.0 to +100.0 kPa
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to +1.010 bar
−14.64 to +14.64 psi
−757 to +757 mmHg
−29.8 to 29.8 inHg
Set pressure range
500 kPa
Pressure withstandability
−0.100 to +1.000 MPa
−0.101 to +1.010 MPa
−101 to +1,010 kPa
−1.03 to +10.30 kgf/cm2
−1.01 to +10.10 bar
−14.6 to +146.4 psi
−100.0 to +100.0 kPa
−101.0 to +101.0 kPa
−1.030 to +1.030 kgf/cm2
−1.010 to +1.010 bar
−14.64 to +14.64 psi
−757 to +757 mmHg
−29.8 to 29.8 inHg
1.5 MPa
−0.100 to +1.000 MPa
−0.101 to +1.010 MPa
−101 to +1,010 kPa
−1.03 to +10.30 kgf/cm2
−1.01 to +10.10 bar
−14.6 to +146.4 psi
500 kPa
Non-corrosive gas
Selectable unit
For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi
Supply voltage
12 to 24 V DC ±10 % Ripple P-P 10 % or less
Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage)
ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage)
360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage)
NPN open-collector transistor
PNP open-collector transistor
• Maximum sink current: 100 mA
• Maximum source current: 100 mA
• Applied voltage: 30 V DC or less (between comparative output and 0 V)
• Applied voltage: 30 V DC or less (between comparative output and +V)
• Residual voltage: 2 V or less (at 100 mA sink current)
• Residual voltage: 2 V or less (at 100 mA source current)
Output operation / Output modes
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
1.5 MPa
Applicable fluid
Comparative output
Comparative output 1,
Comparative output 2 (Note 3)
PHOTOELECTRIC
SENSORS
EMC Directive, RoHS Directive
Type of pressure
Power consumption
LASER
SENSORS
Multi-function
For low pressure
For high pressure
DP-101A(-M)(-P)
DP-102A(-M)(-P)
DP-101A-E-P
DP-102A-E-P
DP-111A-E-P-J
DP-112A-E-P-J
DP-101A-N(-P)
DP-102A-N(-P)
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
NO/NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode
Hysteresis
LASER
MARKERS
Minimum 1 digit (variable) (however, 2 digits when using psi unit)
Repeatability
±0.1 % F.S. (within ±2 digits)
Response time
±0.2 % F.S. (within ±2 digits)
±0.1 % F.S. (within ±2 digits)
±0.2 % F.S. (within ±2 digits)
2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation
Short-circuit protection
Incorporated
ON voltage: 0.4 V DC or less
OFF voltage: 5 to 30 V DC, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
External input (Note 4)
Auto-reference function /
Remote zero-adjustment
function
PLC
ON voltage: 5 V to +V DC
OFF voltage: 0.6 V DC or less, or open
Input impedance: 10 kΩ approx.
Input time: 1 ms or more
Analog voltage output (Note 4)
Output voltage: 1 to 5 V DC
Zero point: within 3 V ±5 % F.S.
Span: within 4 V ±5 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
Output voltage: 0.6 to 5 V
Zero point: within 1 V ±5 % F.S.
Span: within 4.4 V ±5 % F.S.
Linearity: within ±1 % F.S.
Output impedance: 1 kΩ approx.
Analog current output (Note 4)
Output current: 4 to 20 mA
Zero point: 12 mA ±5 % F.S.
Span: 16 mA ±5 % F.S.
Linearity: within ±1 % F.S.
Load resistance: 250 Ω (max.)
Output current: 2.4 to 20 mA
Zero point: 4 mA ±5 % F.S.
Span: 17.6 mA ±5 % F.S.
Linearity: within ±1 % F.S.
Load resistance: 250 Ω (max.)
Display
4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation)
−101.0 to +101.0 kPa
−101.0 to +101.0 kPa
−0.101 to +1.010 MPa
−0.101 to +1.010 MPa
−1.030 to +1.030 kgf/cm2
−101 to +1,010 kPa
−1.030 to +1.030 kgf/cm2
−101 to +1,010 kPa
2
−1.010 to +1.010 bar
−1.010 to +1.010 bar
−1.03 to +10.30 kgf/cm
−1.03 to +10.30 kgf/cm2
−14.64 to +14.64 psi
−14.64 to +14.64 psi
−1.01 to +10.10 bar
−1.01 to +10.10 bar
−757 to +757 mmHg
−757 to +757 mmHg
−14.6 to +146.4 psi
−14.6 to +146.4 psi
−29.8 to 29.8 inHg
−29.8 to 29.8 inHg
Displayable pressure range
Environmental resistance
Indicator
(
Orange LED
Comparative output 1 operation indicator, comparative output 2 operation indicator:
Lights up when each comparative output is ON
Ambient humidity
Voltage withstandability
Insulation resistance
Vibration resistance
Shock resistance
)(
Material
Connecting method / Cable length
Weight
Accessories
)
1,000 V AC for one min. between all supply terminals connected together and enclosure
100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each
Asia: M5 female thread + R (PT) 1/8 male thread [excluding DP-□-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread
Within ±1 % F.S. (at +20 °C +68 °F)
Within ±0.5 % F.S. (at +20 °C +68 °F)
UV
CURING
SYSTEMS
Flow
50MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure
10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each
(when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each)
Pressure port
MACHINE
VISION
SYSTEMS
Pressure/
Head-separated
35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH
Within ±0.5 % F.S. (at +20 °C +68 °F)
FA
COMPONENTS
Pressure/
Digital Display
−10 to +50 °C +14 to +122 °F, Storage: −10 to +60 °C +14 to +140 °F
Temperature characteristics
ENERGY
MANAGEMENT
SOLUTIONS
Selection
Guide
IP40 (IEC)
Protection
Ambient temperature
Orange LED
Comparative output 1 operation indicator: Lights up when comparative output is ON,
Analog voltage output operation indicator: Lights up when setting
HUMAN
MACHINE
INTERFACES
Within ±1 % F.S. (at +20 °C +68 °F)
Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber
Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable.
Net weight: 40 g approx. (DP-10□-M(-P): 30 g approx.), Gross weight: 130 g approx. (DP-10□-M(-P):120 g approx.)
CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type)
Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F.
2) Model Nos. of Asia type having “-M” are short pressure port type. Model Nos. of Asia and North America types having the suffix “-P” are PNP output type.
3) Only standard type is equipped with comparative output 2.
4) Cannot be used at the same time.
DP-0
DP-100
DP-M
723
Dual Display Digital Pressure Sensor
I/O CIRCUIT AND WIRING DIAGRAMS
FIBER
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
I/O circuit diagrams
ZD1
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
D3
(Black)
Load
Comparative output 1
2
5V
Load
100 mA max.
(White) Comparative output 2
3
Internal circuit
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Pressure/
Head-separated
Flow
Standard type
Designation
1
+V
Comparative output 1
+
−
ZD1
Tr1
D
100 mA max.
Users’ circuit
Standard type: Comparative output 2
Multi-function type: Analog output or External input
4
0V
Tr2
2
+
(Black) Comparative output 1
100 mA max.
3
(White) Comparative output 2
(Blue) 0 V
Internal circuit
−
Load
12 to 24 V DC
±10 %
Tr2
3
D2
Internal circuit
Terminal arrangement diagram
3
D3
1kΩ
(Black) Comparative output 1
(White) Analog output Load
or External input
+
−
(Blue) 0 V
Users’ circuit
Designation
1
+V
2
Comparative output 1
3
Standard type: Comparative output 2
Multi-function type: Analog output or External input
4
0V
DP-11□-E-P-J
PNP output type
I/O circuit diagrams
Standard type
ZD1
Tr1
D
1
Multi-function type
Terminal No.
Color code of connection cable
(Brown) +V
D1
100 mA max.
ZD2
Tr2
4
2
3
Internal circuit
+
(Black) Comparative output 1
100 mA max.
(White) Comparative output 2
(Blue) 0 V
Load
−
Terminal arrangement diagram
4
1
Tr2
D2
Internal circuit
Terminal
(Brown) +V
100 mA max.
4
1k
2
3
Users’ circuit
2
12 to 24 V DC
±10 %
Terminal No.
Color code of connection cable
ZD
Tr1
Load
Symbols • • • D : Reverse supply polarity protection diode
ZD1, ZD2 : Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
3
12 to 24 V DC
±10 %
Symbols • • • D1 to D3 : Reverse supply polarity protection diode
ZD : Surge absorption zener diode
Tr1 : PNP output transistor
Tr2 : NPN input transistor
Terminal
4
(Brown) +V
100 mA max.
2
4
Users’ circuit
2
ZD
Tr1
1
D1
Load
Symbols • • • D : Reverse supply polarity protection diode
ZD1, ZD2 : Surge absorption zener diode
Tr1, Tr2 : PNP output transistor
1
Terminal No.
Color code of connector attached cable
Multi-function type
Terminal No.
Color code of connector attached cable
100 mA max.
ZD2
1
12 to 24 V DC
±10 %
(Blue) 0 V
3
(Brown) +V
1
4
Sensor circuit
DP-M
(Black) Comparative output 1
Symbols • • • D1 to D3 : Reverse supply polarity protection diode
ZD : Surge absorption zener diode
Tr1 : PNP input transistor
Tr2 : NPN output transistor
Terminal
4
(White) Analog output
or External input Load
PNP output type
I/O circuit diagrams
DP-0
DP-100
3
2
(Brown) +V
DP-10□-P
Selection
Guide
Pressure/
Digital Display
2
D2
1kΩ
ZD
Users’ circuit
2
Sensor circuit
LASER
MARKERS
Tr2
3
4
Terminal arrangement diagram
1
Tr1
Internal circuit
Symbols • • • D1 to D3 : Reverse supply polarity protection diode
ZD1, ZD2 : Surge absorption zener diode
Tr1, Tr2 : NPN output transistor
WIRE-SAVING
SYSTEMS
STATIC
CONTROL
DEVICES
−
12 to 24 V DC
±10 %
1
D1
D3
(Blue) 0 V
4
SIMPLE
WIRE-SAVING
UNITS
MEASUREMENT
SENSORS
+
100 mA max.
ZD2
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
D2
Tr1
Tr2
(Brown) +V
1
D1
Terminal No.
Color code of connector attached cable
Multi-function type
Terminal No.
Color code of connector attached cable
Standard type
Sensor circuit
AREA
SENSORS
NPN output type
Sensor circuit
MICRO
PHOTOELECTRIC
SENSORS
DP-10□
Sensor circuit
PHOTOELECTRIC
SENSORS
Sensor circuit
LASER
SENSORS
DP-100 SERIES Ver.2
(Black) Comparative output 1
(White) Analog voltage output Load
or External input
Users’ circuit
Symbols • • • D1, D2 : Reverse supply polarity protection diode
ZD : Surge absorption zener diode
Tr1 : PNP output transistor
Tr2 : NPN input transistor
Designation
+V
2
Standard type: Comparative output 2
Multi-function type: Analog output or External input
4
−
(Blue) 0 V
1
3
+
0V
Comparative output 1
12 to 24 V DC
±10 %
Dual Display Digital Pressure Sensor
PRECAUTIONS FOR PROPER USE
• Never use this product as a sensing device for
personnel protection.
• In case of using sensing devices for personnel
protection, use products which meet laws and standards,
such as OSHA, ANSI or IEC etc., for personnel
protection applicable in each region or country.
• The DP-100 series is designed for use with non-corrosive
gas. It cannot be used with liquid or corrosive gas.
DP-100 SERIES Ver.2
Refer to p.1566 for general precautions.
• The MS-DP1-4 panel mounting bracket is available when
switching from the DP2 / DP3 series.
DP2 / DP3
DP
2-2
0
ñ10
1.3k
Front protective cover
DPX-04 (optional)
can be installed on
MS-DP1-4.
Pa
OUT
Remove
1
OUT
2
0-AD
J
MO
DE
DP-100
Sub display
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
Mounting holes
for DP2 / DP3 series
can be used as is.
Panel mounting bracket MS-DP1-4
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
Mode selection Decrement
key
key
Increment
key
Wiring
• Make sure that the power supply is off while wiring.
• Verify that the supply voltage variation is within the rating.
• If power is supplied from a commercial switching regulator,
ensure that the frame ground (F.G.) terminal of the power
supply is connected to an actual ground.
• In case noise generating equipment (switching regulator,
inverter motor, etc.) is used in the vicinity of this sensor,
connect the frame ground (F.G.) terminal of the equipment
to an actual ground.
• Do not run the wires together with high-voltage lines or
power lines or put them in the same raceway. This can
cause malfunction due to induction.
• Incorrect wiring will cause problems with operation.
Connection
• Do not apply stress directly to
the connection cable leader or
to the connector.
Connector
attached cable
[CN-14A(-R)-C□]
Mounting
• MS-DP1-1 / MS-DP1-5 sensor mounting brackets are
available separately, and it should be used for mounting.
When tightening the sensor to the sensor mounting bracket,
use a tightening torque of 0.5 N·m or less.
• An conversion bushing is available for when using the DP-10□-M
short pressure port type. It can be used to switch between this
model and the DP2 / DP3 series. When connecting to the
pressure port, use a
M5 female thread
Rc 1 8 female thread
tightening torque of
1.0 N·m or less.
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
Conversion bushing MS-DP1-7
• The MS-DP1-F□ flat attachment is available for when using the DP-10□-M
short pressure port type. If using the MS-DP1-F□ flat attachment (optional),
install by following the procedures given below.
1 Decide the direction of this product to mount with the sensor.
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
Pressure port
faces downward
Pressure port
faces leftward
Pressure port
faces rightward
Note: It is not possible to mount this product such
that the pressure port faces upward.
2
Mount this product with the M3 female threads of the
sensor by using the attached M3 (length 8 mm 0.315 in)
screws. The tightening torque should be 0.5 N·m or less.
M3 female thread
)
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Pressure port
faces upward
M3 (length 6 mm 0.236 in)
screws with washers
Accessory for MS-DP1-1
and MS-DP1-5
(
LASER
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
Insert
Main display
FIBER
SENSORS
AREA
SENSORS
Remove
Part description
Comparative output 1 operation indicator
Comparative output 2 operation indicator
Work as analog voltage output operation
indicator in Multi-function type
724
M3 (length 8 mm 0.315 in)
screw (Accessory)
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
Sensor mounting bracket
MS-DP1-1 (Optional)
DP-100
M3 female thread
DP-M
3
• The MS-DP1-2 panel mounting bracket (optional) and the
MS-DP1-3 front protection cover (optional) are also
available.
Mount this product with the mounting surface by using
the attached M4 (length 20 mm 0.787 in) screws. The
tightening torque should be 1.2 N·m or less.
Groove
Front protection cover
MS-DP1-3 (optional)
Connector attached cable
M4 (length 20 mm 0.787 in)
screw (Accessory)
Note: Take care that if the cable with connector is sticking out of the side
groove of this product when mounting, the cable may disconnected.
Panel mounting bracket
MS-DP1-2 (optional)
725
FIBER
SENSORS
LASER
SENSORS
PHOTOELECTRIC
SENSORS
MICRO
PHOTOELECTRIC
SENSORS
AREA
SENSORS
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
PARTICULAR
USE
SENSORS
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
Dual Display Digital Pressure Sensor
DP-100 SERIES Ver.2
PRECAUTIONS FOR PROPER USE
Conditions in use for CE conformity
• The DP-100 series is a CE conformity product complying
with EMC Directive. The harmonized standard with regard to
immunity that applies to this product is EN 61000-6-2 and the
following condition must be met to conform to that standard.
Condition
• The line to connect with this sensor should be less than
30 m 98.425 ft.
Piping
12 mm 0.472 in
• If connecting a commercially-available
spanner
coupling to the pressure port, attach a
12 mm 0.472 in spanner (14 mm
0.551 in spanner for DP-100-E type)
to the hexagonal section of the
pressure port to secure it, and tighten
at a torque of 9.8 N·m or less. If it is
tightened using excessive torque, it may
damage the coupling or the pressure port.
In addition, wrap sealing tape around the coupling when
connecting it to prevent leaks.
• If connecting a commercially-available joint to the
pressure port of the DP-10□-M(-P), hold the main unit in
your hand to steady it, and tighten to a torque of 1.0 N·m
or less. If it is tightened to an excessive torque, the joint or
the main unit may become damaged.
• If connecting a commercially-available joint to the
pressure port of the MS-DP1-7, tighten to a torque of 9.8
N·m or less.
14 mm 0.551 in
spanner
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
• The tightening torque should be 1 N·m or less when
connecting a coupling to the pressure port of MS-DP1-FM.
Selection
Guide
Pressure/
Digital Display
Pressure/
Head-separated
Flow
DP-0
DP-100
DP-M
Pressure port
Coupling (Purchase separately.)
• When connecting the coupling to the pressure port of
MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm
0.551 in spanner and make sure that the tightening torque
is 9.8 N·m or less.
In addition, in order to prevent any leakage, wind a sealing
tape on the coupling when connecting.
14 mm 0.551 in
spanner
Note: Do not tighten the pressure port by holding the product with the
spanner. It may cause the product breakage.
Refer to p.1566 for general precautions.
Flat attachment
• Make sure to mount MS-DP1-F□ with the sensor properly.
If it is not mounted properly, air leakage may occur.
• Take care that the excessive mounting and dismounting of
this product may cause deterioration of the O-ring.
• If you touch the O-ring of MS-DP1-F□, or any scratch or
dust, etc. is attached to it, air leakage may occur and the
sensing performance may deteriorate.
Take sufficient care when using and storing MS-DP1-F□.
Others
• Use within the rated pressure range.
• Do not apply pressure exceeding the pressure withstandability
value. The diaphragm will get damaged and correct operation
shall not be maintained.
• Do not use during the initial transient time (0.5 sec. approx.)
after the power supply is switched on.
• Avoid dust, dirt, and steam.
• Take care that the sensor does not come in direct contact with
water, oil, grease, or organic solvents, such as, thinner, etc.
• Do not insert wires, etc., into the pressure port. The
diaphragm will get damaged and correct operation shall not
be maintained.
• Do not operate the keys with pointed or sharp objects.
RUN mode
• This is the normal operating mode.
Setting item
Description
Threshold value
setting
The threshold values for ON/OFF operation can be
changed directly by pressing the increment key
(UP) and the decrement key (DOWN).
Zero-adjustment
function
This forces the pressure value display to be reset to zero when
the pressure port is open on the atmospheric pressure side.
Key lock function
Stops key operations from being accepted.
Peak hold /
bottom hold function
Displays the peak value and bottom value for fluctuating
pressure. The peak value appears in the main display,
and the bottom value appears in the sub display.
MENU SETTING mode
• If the mode selection key is pressed and held for 2
seconds in RUN mode, the mode will switch to MENU
SETTING mode.
• If the mode selection key is pressed while a setting is
being made, the mode will switch to RUN mode. In this
case, the settings that have been changed will be entered.
Setting item
Comparative output 1
output mode setting
Description
Sets the output mode for comparative output 1.
Comparative output 2 output mode
Sets the output mode for comparative output 2.
setting (standard type only)
Analog output / external
input switching
(multi-function type only)
Allows switching between analog voltage output /
analog current output, and auto-reference input /
remote zero-adjust-ment input.
NO/NC switching
Sets normally open (NO) or normally closed (NC).
Response time setting
Sets the response time.
The response time can be selected from 2.5 ms,
5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms,
500 ms, 1,000 ms and 5,000 ms.
Display color switching
for main display
Allows the color for the main display to be changed.
The colors can be set to ‘red / green’ or ‘green / red’
to correspond to ON/OFF output, or it can be fixed
at ‘red’ or ‘green’ all the time.
Unit switching
Pressure unit can be changed.
Dual Display Digital Pressure Sensor
PRECAUTIONS FOR PROPER USE
Sub display switching
Display refresh rate
switching
Changes the display refresh rate for the
pressure value displayed in the main display.
Hysteresis fix value
switching
Sets the hysteresis for EASY mode and window
comparator mode. (8 steps)
Linked display color
switching
(standard type only)
Allows the display color for the main display to
be switched in line with the output operation for
comparative output 1 or comparative output 2.
ECO mode setting
Allows power consumption to be reduced by
dimming the display or turning it off.
Setting check code
Allows the setting details to be checked via
codes.
Setting copy mode
Allows the setting details for the master sensor
to be copied to slave sensors.
Reset setting
Resets the settings to the factory settings.
Code
Standard type
Hysteresis
NO
OFF
NC
EASY
NO
NC
Window
comparator
NC
—
—
—
NO
NC
NO
Hysteresis
NO
—
OFF
Window
comparator
NC
—
ADJ.
NO
—
—
NC
—
—
—
—
—
—
Comparative
output 1
Comparative
output 2
Comparative
output 1
Comparative
output 2
Comparative
Always output 1
red
Comparative
output 2
Comparative
Always output 1
green Comparative
output 2
Analog voltage
P-1, Lo-1 Red
output
when ON
Autoreference Hi-1
Remote
zero-adjustment P-2, Lo-2 Green
when ON
Analog current
Hi-2
output
20
0.787
7.5 9.5
0.295 0.374
R (PT) 1/ 8
male thread
(North America: NPT 1/ 8)
1.5
0.059
5th digit
Response time
2.5 ms
5 ms
10 ms
25 ms
50 ms
100 ms
250 ms
500 ms
1,000 ms
5,000 ms
6th digit
Unit switching
MPa
kPa
kgf/cm2
bar
psi
mmHg
inchHg
—
—
—
Connector
12
0.472
7th digit
Display refresh rate
250 ms
500 ms
1,000 ms
—
—
—
—
—
—
—
8th digit
ECO mode
OFF
STD
FULL
—
—
—
—
—
—
—
Europe
14
0.551
G 1/ 8
male thread
20
0.787
M5 female thread,
4 0.157 deep
DP-11□-E-P-J
Sensor
20
0.787
7
0.276
9.5
0.374
4.5 0.177
1.5
0.059
15
0.591
SENSOR
OPTIONS
SIMPLE
WIRE-SAVING
UNITS
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Pressure/
Digital Display
DP-0
DP-100
connector
M3 female thread,
4 0.157 deep
30
1.181
PARTICULAR
USE
SENSORS
DP-M
ø8.3
ø0.327
47.5
25.5 1.870
1.004
INDUCTIVE
PROXIMITY
SENSORS
Flow
20
0.787
4.5
0.177
1.5
0.059
PRESSURE /
FLOW
SENSORS
Pressure/
Head-separated
Sensor
30
1.181
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
10 7
0.394 0.276
M5 female thread
M3 female thread, 4 0.157 deep
DP-10□-M(-P)
30
1.181
25.5
1.004
AREA
SENSORS
STATIC
CONTROL
DEVICES
Code
25.5
1.004
MICRO
PHOTOELECTRIC
SENSORS
MEASUREMENT
SENSORS
Sensor
42.5
1.673
PHOTOELECTRIC
SENSORS
WIRE-SAVING
SYSTEMS
20
0.787
30
1.181
4th digit
Standard
type only
The CAD data can be downloaded from the website.
30
1.181
30
1.181
Multi-function 3rd digit
type
Comparative output 2 NO/NC Analog voltage output / Threshold Display color for Display
Comparative output 1 NO/NC
switching output mode
switching External input
value display main display color linking
output mode
DIMENSIONS (Unit: mm in)
30
1.181
2nd digit
1st digit
EASY
FIBER
SENSORS
LASER
SENSORS
Table of codes
Description
Changes the information in the sub display
during RUN mode operation to the desired
alphanumeric display.
DP-10□(-P)
726
Refer to p.1566 for general precautions.
PRO mode
• If the mode selection key is pressed and held for 5
seconds in RUN mode, the mode will switch to PRO
mode.
• If the mode selection key is pressed while a setting is
being made, the mode will switch to RUN mode. In this
case, the settings that have been changed will be entered.
Setting item
DP-100 SERIES Ver.2
G 1/8 male thread
7 0.276
20
0.787
M8 connector
14
0.551
M5 female thread
M3 female thread,
4 0.157 deep
727
FIBER
SENSORS
LASER
SENSORS
Dual Display Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
Sensor mounting bracket (Optional)
Assembly dimensions
ø2.3
ø0.091
MICRO
PHOTOELECTRIC
SENSORS
9.5
14.5
0.571 0.374
AREA
SENSORS
22
0.866
30
1.181
20
0.787
13
0.512
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
SENSOR
OPTIONS
22
0.866
14.5
0.571
4.2
0.165
2-ø3.5 ø0.138
25.5
1.004
42.5
1.673
9.5
0.374
7.5
0.295
5.3
(0.209
)
5.5
0.217
20
0.787
2-R2.1 R0.083
9.5
0.374
2-R2.1 R0.083
R13
20
0.787 R0.512
t2
t 0.079
Mounting drawing with DP-10□(-P)
1
0.039
4.2
0.165
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
SIMPLE
WIRE-SAVING
UNITS
The CAD data can be downloaded from the website.
MS-DP1-1
PHOTOELECTRIC
SENSORS
PARTICULAR
USE
SENSORS
DP-100 SERIES Ver.2
45
1.772
44
1.732
30
1.181 45
1.772
12
0.472
30
1.181
15
0.591
1.5
0.059
30
1.181
Material: Cold rolled carbon steel (SPCC)
(Trivalent uni-chrome plated)
t2
t 0.079
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
WIRE-SAVING
SYSTEMS
MEASUREMENT
SENSORS
STATIC
CONTROL
DEVICES
LASER
MARKERS
PLC
HUMAN
MACHINE
INTERFACES
ENERGY
MANAGEMENT
SOLUTIONS
FA
COMPONENTS
MS-DP1-5
Sensor mounting bracket (Optional)
Assembly dimensions
Mounting drawing with DP-10□-M(-P)
R6.75
R0.266
22.75
0.896
29.5
1.161
20
0.787
4.5
0.177
16
0.630
28
1.102
8.5
0.335
30
1.181
4.5
0.177
44.5
30 1.752
1.181
20
0.787
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
ø4.5
ø0.177
13.5
0.531
20
0.787
2-ø3.5 ø0.138
49.5
(1.949
)
t 1.5
t 0.059
ø8.3
ø0.327
20
49.5
0.787 28.5 1.949
1.122
ø4.5
ø0.177
Material: Stainless steel (SUS304)
20
0.787
29.5
1.161
30
1.181
Two M3 (length 6 mm 0.236 in) screws with washers are attached.
MS-DP1-2 MS-DP1-3
1.5
0.059
28
1.102
53.5
2.106
4.5
0.177
t 1.5
t 0.059
Panel mounting bracket (Optional), Front protection cover (Optional)
Selection
Guide
Assembly dimensions
Pressure/
Digital Display
Mounting drawing with DP-10□(-P)
Panel cut-out dimensions
Pressure/
Head-separated
When 1 unit is installed
0
31−0.4
0
1.220 −0.016
Flow
0
DP-0
39.3
( 1.547
)
DP-100
34.5
1.358
DP-M
(
34.5 20
1.358 0.787
7.2
0.283
11
0.433
Front
protection
cover
)
50
1.969
33.4
1.315
31−0.4
0
1.220 −0.016
(Note 2)
9.5
18.3 7.5
0.374
0.720 0.295
8.7
0.343
When “n” units are installed horizontally in series When “n” units are
installed vertically in series
0
12 (Note 2)
0.472
R 1/ 8
male thread (Note 1)
31−0.4
0
1.220 −0.016
31 1.220 Xn + 3.5 0.138 X (n-1)
0
31−0.4
0
1.220 −0.016
55 2.165
or more
Panel thickness dimension
1 to 6 mm 0.039 to 0.236 in
Connector
33.4
1.315
M5 female thread,
4 0.157 deep
(52 2.047 max)
View A
M3 female thread,
4 0.157 deep
31 1.220 Xn + 3.5 0.138 X (n-1)
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
55 2.165
or more
Note: The panel thickness should be
1 to 6 mm 0.039 to 0.236 in.
Material: Polyacetal (Panel mounting bracket)
Polycarbonate (Front protection cover)
Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N
(-P)has a NPT1/8 male thread.
2) In case of DP-10□-E-P, the dimension 7.5 become to be 10, the dimension 9.5 become to be 7 and the dimension 12 become to be 14.
Dual Display Digital Pressure Sensor
DIMENSIONS (Unit: mm in)
DP-100 SERIES Ver.2
728
The CAD data can be downloaded from the website.
MS-DP1-4
Panel mounting bracket (Replacement from conventional model) (Optional)
Assembly dimensions
(
42.7
1.681
40
1.575
30
1.181
)
36
1.417
26.5
1.043
6.5 0.256
3 0.118
(0.3829.7)
40 30
1.575 1.181
Front protection cover
(DPX-04)
Panel thickness dimension 1 to 3.2 mm
0.039 to 0.126 in
36
1.417
M5 female
thread
Panel mounting
bracket body
8
0.315
AREA
SENSORS
Connector
12
0.472
42.7
1.681
MICRO
PHOTOELECTRIC
SENSORS
56
2.205
R 1/ 8
male thread
(Note 1)
Spacer
+0.5
0
+0.020
0
SAFETY LIGHT
CURTAINS /
SAFETY
COMPONENTS
36 +0.5
0
1.417+0.020
0
80
3.150
PRESSURE /
FLOW
SENSORS
INDUCTIVE
PROXIMITY
SENSORS
Panel mounting
bracket
PARTICULAR
USE
SENSORS
Material: Nylon 6 (Panel mounting bracket body)
Stainless steel (SUS304) (Panel mounting bracket)
Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) (Spacer)
SENSOR
OPTIONS
Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N
(-P)has a NPT1/8 male thread.
2) The panel tickness should be 1 to 32 mm 0.039 to 1.260 in.
MS-DP1-FM
Flat attachment (Optional)
SIMPLE
WIRE-SAVING
UNITS
MS-DP1-FR/FN/FE
Flat attachment (Optional)
Assembly dimensions
Assembly dimensions
Mounting drawing with DP-10□-M(-P)
Mounting drawing with DP-10□-M(-P)
44.5
(1.752
)
24
(0.945
)
37
1.457
11.5
0.453
30
1.181
44.5
1.752
6.5 0.256
5.5 0.217
20
0.787
24
0.945
30
1.181
2-ø4.3 ø0.169
24
0.945
PLC
HUMAN
MACHINE
INTERFACES
24
0.945
Material: Polybutylene terephthalate (PBT)
(Glass fiber reinforced) (Enclosure)
Stainless steel (SUS303) (Pressure port)
Hydrogenated Nitrile Butadiene Rubber
(H-NBR) (O-ring)
Weight: 15 g approx. (flat attachment only)
14
0.551
20
0.787
24
0.945
30
1.181
2-ø4.3
ø0.169
Pressure port
G1/8 female thread (Note)
Two M3 (length 8 mm 0.315 in) screws,
8.5 0.335 two M4 (length 20 mm 0.787 in) screws
are attached.
MEASUREMENT
SENSORS
LASER
MARKERS
11.5
0.453
6.5 0.256
5.5 0.217 13.5
0.531
17.5
0.689
M5 female thread
37
1.457
11
0.433
30
1.181
52.5
2.067
WIRE-SAVING
SYSTEMS
STATIC
CONTROL
DEVICES
52.5
( 2.067
)
24
(0.945
)
11
0.433
LASER
SENSORS
PHOTOELECTRIC
SENSORS
Panel cut-out dimensions
Mounting drawing with DP-10□(-P)
FIBER
SENSORS
ENERGY
MANAGEMENT
SOLUTIONS
Product distinguishing mark
MS-DP1-FR: 0 line
MS-DP1-FN: 1 line
MS-DP1-FE: 2 line
FA
COMPONENTS
8.5
0.335
17.5
0.689
Material: Polybutylene terephthalate (PBT)
(Glass fiber reinforced) (Enclosure)
Stainless steel (SUS303) (Pressure port)
Hydrogenated Nitrile Butadiene Rubber (H-NBR)
(O-ring)
Weight: 25 g approx. (flat attachment only)
Two M3 (length 8 mm 0.315 in) screws, two M4
(length 20 mm 0.787 in) screws are attached.
MACHINE
VISION
SYSTEMS
UV
CURING
SYSTEMS
Selection
Guide
Note: MS-DP1-FR has a Rc1/8 female thread.
MS-DP1-FN has a NPT1/8 female thread.
Pressure/
Digital Display
Pressure/
Head-separated
Flow
MS-DP1-7
Conversion bushing (Optional)
CN-14A(-R)-C□
15.8
0.622
(0.3158 )
(
35
1.378
)
Connector attached cable (Optional, CN-14A-C2 is attached to the sensor)
(
0.5
0.020
11 0.433
)
10 0.394
7.8
0.307
M5 male thread
Gasket
(
50
1.969
ø3.7 ø0.146 cable
• Length L
Model No.
8
0.315
Rc1/8 female thread
Material: Brass (Nickel plated)
Weight: 10 g approx.
DP-100
DP-M
L
14
0.551
3.5
0.138
DP-0
Length L (mm in)
CN-14A(-R)-C1
1,000 39.370
CN-14A(-R)-C2
2,000 78.740
CN-14A(-R)-C3
3,000 118.110
CN-14A(-R)-C5
5,000 196.850
)
(0.3158 )