0
登录后你可以
  • 下载海量资料
  • 学习在线课程
  • 观看技术视频
  • 写文章/发帖/加入社区
创作中心
发布
  • 发文章

  • 发资料

  • 发帖

  • 提问

  • 发视频

创作活动
DP-102-J

DP-102-J

  • 厂商:

    NAIS(松下)

  • 封装:

    Module

  • 描述:

    SENSOR PRESSURE -0.1 - 1MPA

  • 数据手册
  • 价格&库存
DP-102-J 数据手册
713 FIBER SENSORS Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 Related Information LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS For Gas ■■General terms and conditions.............. F-3 ■■Glossary of terms........................ P.1563~ ■■Korea’s S-mark.............................. P.1602 ■■Selection guide.............................. P.699~ ■■General precautions...................... P.1566 Ver.2 Recognition AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Certified [DP-101(A)/102(A) only] PARTICULAR USE SENSORS * Passed the UL 991 Environment Test SENSOR OPTIONS * UL 61010C-1 compatible, Passed the UL 991 Environment Test based on SEMI S2-0200. [Category applicable for semiconductor manufacturing: TWW2, Process Equipment] [Applicable standards: UL 61010C-1] [Additional test / evaluation standards as per intended use: UL 991, SEMI S2-0200] SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS panasonic.net/id/pidsx/global STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Digital Auto reference With analog output Dual 3-color display makes operation easier! Achieved further efficiency with 4 upgrades, keeping the same operability UPGRADE 1 Superior visibility Improved visibility in Digital Display Improvements to the digital display deliver a wide viewing angle along with increased clarity. The display pressure range and set pressure range have also been increased. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Old DP-100 series New DP-100 series Flow DP-0 DP-100 DP-M UPGRADE 2 Long-distance transmission of analog output Addition of analog current output capability to multifunctional models Users can now select either voltage output or current output as analog output according to their application. Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 APPLICATIONS Confirming suction of electronic component 714 FIBER SENSORS Confirming reference pressure Air-leak test for PET bottles LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS UPGRADE 3 Reduced environmental impact 14 % lower power consumption (during normal operation) Thanks to a redesign of its circuitry, power consumption of the low-power-consumption DP-100 series during normal operation has been reduced by 14 %. The display is shut off entirely during ECO / FULL mode operation for power savings of up to 50 % compared to normal operation, and display brightness is lowered during ECO / STD mode operation for power savings of up to 30 % compared to normal operation. 14 % lower after update SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Old DP-100 series New DP-100 series 840 mW (normal operation) 720 mW (normal operation) Up to 50 % lower in ECO mode STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Normal operation ECO / FULL operation 720 mW 360 mW ENERGY MANAGEMENT SOLUTIONS UPGRADE 4 FA COMPONENTS Enhanced power circuitry Addition of a reverse polarity protection circuit to the transistor output circuit MACHINE VISION SYSTEMS UV CURING SYSTEMS To prevent from breakage due to miswiring. “Current value” and “threshold value” can be checked at the same time! Dual display allows direct setting of threshold value Equipped with a 30 mm 1.181 in square compact-sized dual display. The current value and the threshold value can be checked at the same time, so the threshold value can be set and checked smoothly without switching to another screen mode. ON/OFF operations still continue while the threshold values are being set, so setting to the same sensitivity as dial control-type sensors is possible. Key lock function is equipped as well. Current value Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DP-0 DP-100 DP-M Threshold value 715 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Dual Display Digital Pressure Sensor 3-color display (Red, Green, Orange) Readable digital display! The main display changes color in line with changes in the status of output ON/OFF operation, and it also changes color while setting is in progress. The sensor status can therefore be understood easily, and operating errors can be reduced. Alphanumeric indication in 12 segments is used. This improved visual checking. Main Display OFF: Green (or Red) STATIC CONTROL DEVICES LASER MARKERS ON: Red (or Green) SET: Orange During normal operation During setting BASIC PERFORMANCE All models in the line-up are compound pressure types High performance accomplished Low pressure type No sensor settings are required to switch between positive pressure and negative pressure, so that the number of registered part numbers can be decreased. The low pressure type displays measurements in 0.1 kPa at a resolution of 1/2,000 and has a response time of 2.5 ms (variable up to 5,000 ms), ±0.5 % F.S. temperature characteristics and ±0.1 % F.S. repeatability, giving it high performance. Ideal for applications such as suction. No mis-operations due to vacuum breakdown occur. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS DP-100 SERIES Ver.2 –100 kPa For low pressure 0 kPa Ideal for applications such as checking reference pressure. Can also be used for simple suction. 100 kPa DP-101□ 1 MPa For high pressure DP-102□ Resolution: 1/2,000 Response time: 2.5 ms Temperature characteristics: ±0.5 % F.S. Repeatability: ±0.1 % F.S. Displays measurements in 0.1 kPa PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated FUNCTIONS Copy function reduces man-hours and human error Sensors can be connected to a master sensor one by one, and a copy of the setting details for the master sensor can be transmitted as data to other sensors. If making the same settings for multiple sensors, this prevents setting errors among other sensors and in addition, when machinery design are changed, there would be less change in work orders. Details transmitted Copying via wiring Master sensor Power supply +V +V 0V 0V Comparative output 1 Comparative output 1 Comparative output 2 Comparative output 2 Details received Slave sensor Detail s cop ied Note: Settings cannot be copied from the new version (Ver. 2) to the old version. However, settings can be copied from the old version to the new version (Ver. 2). Flow DP-0 DP-100 DP-M The sensor’s setting operation mode has a 3-level configuration to suit the frequency of use The setting levels are clearly separated into “RUN mode” for operation settings that are carried out daily, “MENU SETTING mode” for basic settings, and “PRO mode” for special and detailed setting. These make setting operations easy to understand and easy to carry out. Simple setting RUN mode MENU SETTING mode Special and detailed setting PRO mode RUN mode Settings such as threshold value adjustment and key lock operation can be carried out while the sensor is operating. MENU SETTING mode Basic settings such as output mode setting and NO/NC switching can be carried out. PRO mode High-level function settings such as hysteresis adjustment and the copy function can be carried out. Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 FUNCTIONS Equipped with independent dual output and three output modes Equipped with two independent comparative outputs, and separate sensing modes can be selected for each of them. Since there are two comparative outputs, one of the comparative outputs can even be used for alarm output. In addition, output, which is not being used, can be disabled. 1 Pressure Suction checking Comparative output 0 ON OFF Hysteresis mode Vacuum breakdown checking 0 kPa P-2 Reference pressure alarm output is possible during reference pressure checking! ON Reference pressure checking Comparative output 1 Hysteresis mode OFF Alarm output ON Comparative output 2 EASY mode OFF H (Hysteresis) Lo 0 ON Comparative output OFF Note: “ ” or “ output 1, and “ 3 LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS Hi H: 1 digit or more ” appears in the sub display for comparative ” or “ ” appears for comparative output 2. Window comparator mode This mode is used for setting comparative output ON and OFF at pressures within the setting range. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC Lo-1 Hi-1 Pressure 0 kPa H: Fixed This mode is used for setting comparative output hysteresis to the desired level and for carrying out ON/OFF control. P-1 FIBER SENSORS AREA SENSORS Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) “ ”appears in the sub display for comparative output 1, and “ ” appears for comparative output 2. Pressure –100 kPa H (Hysteresis) P 2 ON Comparative output 2 EASY mode OFF EASY mode This mode is used for comparative output ON/OFF control. Vacuum breakdown can also be notified during suction applications! ON Comparative output 1 EASY mode OFF Standard type 716 P-2 H (Hysteresis) Hi H (Hysteresis) Lo 0 ON Comparative output OFF H: Fixed Notes: 1) Hysteresis can be fixed to one of eight different levels. 2) “ ” or “ ” appears in the sub display for comparative output 1, and “ ” or “ ” appears for comparative output 2. Possible to switch over analog output and external input Multi-function type HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Multi-function type that enables the selection of analog output (voltage/current) or external input (auto-reference/ remote zero-adjustment) is available. It complies a wide range of applications. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Comparative output Selection Multi-function type Analog output or External input is lighting. Voltage Low pressure type: 1 to 5 V, High pressure type: 0.6 to 5 V Current Low pressure type: 4 to 20 mA, High pressure type: 2.4 to 20 mA Auto-reference/remote zero-adjust Flow DP-0 DP-100 DP-M 717 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Dual Display Digital Pressure Sensor FUNCTIONS Equipped with auto-reference/remote zero-adjustment functions. More precise pressure management is achieved with a minimum of effort Multi-function type If the reference pressure of the device changes, two functions are selectable. One is auto-reference function, which partially shift the comparative output judgment level by the amount that the reference pressure shifts. The other is remote zero-adjustment function, which can reset the display value to zero via external input. These functions are ideal for places where the reference pressure fluctuates wildly, or where fine settings are required. With auto-reference function applied SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS Sets the absolute threshold level Auto-reference input The display remains at “30” and only the threshold level is changed. 30 LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS Comparative output: Window comparator mode Hi-1…0, Lo-1…–5 Sets the absolute threshold level Remote zero-adjustment input The display is forced to “0”, and only the filling pressure drop range is displayed. 30 OK 25 20 Threshold level after applying auto-reference input 15 0 –5 25 OK 20 Threshold level after applying remote zero-adjustment input 15 Threshold level before applying auto-reference input MEASUREMENT SENSORS STATIC CONTROL DEVICES With remote zero-adjustment function applied Comparative output: Window comparator mode Hi-1…0, Lo-1…–5 PARTICULAR USE SENSORS SENSOR OPTIONS DP-100 SERIES Ver.2 Threshold level before applying remote zero-adjustment input Trial 1 Pressure 0 –5 Trial 1 Pressure 0 Auto-reference input value… Time When auto-reference input is applied, the reference pressure “30” is added to the threshold level. If the reference pressure changes to “20” or “40”, the auto-reference input compensates for this every time by changing the threshold level, so any variation in the filling pressure can be ignored. –5 Displayed when remote zero-adjustment input is applied… Time When remote zero-adjustment input is applied, the reference pressure is forced to “0”. If the reference pressure changes to “20” or “40”, the remote zero-adjustment input adjusts the reference pressure to “0” every time the reference pressure changes, so any variation in the filling pressure can be ignored. Sub display can be customized Setting details can be recognized at a glance The sub display can be set to indicate any other desired values or letters apart from the threshold value. This eliminates the need for tasks such as affixing a label to the device to indicate the normal pressure value. The DP-100 setting details appear in the digital display. Because the settings are in numeric form that can be easily understood, it is useful such as when receiving technical support by telephone. UV CURING SYSTEMS 2nd digit: Setting status for comparative output 2 1st digit: Setting status for comparative output 1 3rd digit: Threshold value setting 4th digit: Display color setting Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow 5th digit: Response time setting 6th digit: Display unit setting DP-0 DP-100 DP-M 8th digit: ECO mode setting 7th digit: Display refresh rate setting Peak hold and Bottom hold functions Energy-saving design! Equipped with an ECO mode The peak values and bottom values for fluctuating pressures can be displayed using the dual display. This mode lowers the display luminance to cut power consumption by approximately 30 %. The displays can also be turned off completely to achieve a power saving of approximately 50 %. Power consumption Normal Approx. Power consumption Approx. ECO-STD 30 % less ECO-FULL 50 % less Current consumption for 24 V power supply: 20 mA or less Current consumption for 24 V power supply: 15 mA or less Blinks alternately Current consumption for 24 V power supply: 30 mA or less Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 MOUNTING FIBER SENSORS Tight installation to panels is possible LASER SENSORS An exclusive mounting bracket that is suitable for 1 to 6 mm 0.039 to 0.236 in panel thickness is available. Tight installation is possible Neat and space saving PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Front protection cover available MS-DP1-3 AREA SENSORS A single mounting hole! An exclusive mounting bracket (MS-DP1-1) that supports tight installation is available • MS-DP1-5 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Space savings can also be achieved even when an L-shaped mounting bracket is used. • MS-DP1-1 718 Tight installation is possible SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS Ceiling mounting Floor mounting Rear mounting Positioning bosses for easier mounting bracket installation PLC HUMAN MACHINE INTERFACES Cable can be connected with one-touch Types without connector attached cable are also available Connector attached cable (2 m 6.562 ft), as an accessory, can be connected easily with one-touch connection. Commercially-available connectors can be used for cable connections. Cables in required length can be used, so this contributes to reduction in waste of unwanted cables. DP-10□-J ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Environmentally friendly * Connection cable * Options: 1 m 3.281 ft / 3 m 9.843 ft / 5 m 16.404 ft types are also available. Commercially-available parts can be used! * Refer to p.721 for recommended commercially-available connectors. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DP-0 DP-100 DP-M 719 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 VARIETIES DP-10□-M Short pressure port type is lightweight and takes up little space Compact size with a depth of only 30 mm 1.181 in, so that it can easily fit into narrow spaces. Further, 10 g lighter than standard types. This reduces the loads on movable parts such as robot arms. Standard type M5 female thread + R 1/8 male thread Elbow joint Short pressure port type DP-10□-M(-P) SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Short pressure port type DP-10□-M(-P) Shortened to 12.5 mm 0.492 in ! Light weight 30g approx. PARTICULAR USE SENSORS SENSOR OPTIONS 30 mm 1.181 in SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS M5 female thread [Material: Stainless steel (SUS)] *T  he illustration shows connection using an elbow joint. The elbow joint is sold separately. M8 plug-in connector types are also available (Only for Europe) STATIC CONTROL DEVICES Mating cable CN-24A-C2 (cable length 2 m 6.562 ft) CN-24A-C5 (cable length 5 m 16.404 ft) LASER MARKERS DP-11□-E-P-J M8 connector PLC HUMAN MACHINE INTERFACES G 1/8 male thread M5 female thread ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow Flat installation on the wall by shifting the direction For short pressure port type of the pressure port Rc1/8 conversion bushing is available. Compatible with conventional model For short pressure port type By mounting the flat attachment to DP-10□-M(-P), pressure port and cable can now be pulled out in downward, left or right directions. Flat mounting on surfaces such as the wall is made possible. By equipping the push-in converter with DP-10□-M(-P), pressure port can be converted from M5 female thread to Rc1/8 female thread. Bore diameter conversion to the DP2 / DP3 series is possible. Conventional model DP2 / DP3 series can be switched over to DP-100 series. Conventional model M5 female thread Rc1/8 female thread Flat attachment MS-DP1-F□ DP-0 20 mm 0.787 in pitch DP-100 DP-M Model No. 3 possible directions to mount 20 mm 0.787 in pitch Pressure port MS-DP1-FM M5 female thread MS-DP1-FR Rc1/8 female thread MS-DP1-FN NPT1/8 female thread MS-DP1-FE G1/8 female thread Conversion bushing MS-DP1-7 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 ORDER GUIDE 720 FIBER SENSORS LASER SENSORS Type Asia Standard Multi-function M8 plug-in connector type Europe Multi-function North America Standard pressure port type Standard Standard Multi-function Appearance Model No. For low pressure −100.0 to +100.0 kPa DP-101 For high pressure −0.100 to +1.000 MPa DP-102 For low pressure −100.0 to +100.0 kPa DP-101A For high pressure −0.100 to +1.000 MPa DP-102A For low pressure −100.0 to +100.0 kPa DP-101-E-P For high pressure −0.100 to +1.000 MPa For low pressure −100.0 to +100.0 kPa For high pressure −0.100 to +1.000 MPa For low pressure −100.0 to +100.0 kPa DP-111-E-P-J For high pressure −0.100 to +1.000 MPa DP-112-E-P-J For low pressure −100.0 to +100.0 kPa For high pressure −0.100 to +1.000 MPa For low pressure −100.0 to +100.0 kPa Standard For high pressure For low pressure Multi-function For high pressure * CN-14A-C2 Connector attached cable 2 m 6.562 ft is attached. Excluding M8 plug-in connector type ( ( −0.100 to +1.000 MPa ) ) −100.0 to +100.0 kPa −0.100 to +1.000 MPa For low pressure −100.0 to +100.0 kPa For high pressure −0.100 to +1.000 MPa Standard Asia Short pressure port type Rated pressure range For low pressure −100.0 to +100.0 kPa Multi-function For high pressure −0.100 to +1.000 MPa Pressure port Comparative output M5 female thread + NPN open-collector transistor R 1/8 male thread M5 female thread DP-102-E-P + PNP open-collector transistor G 1/8 DP-101A-E-P male thread DP-102A-E-P PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS M5 female thread + PNP open-collector transistor G 1/8 DP-111A-E-P-J male thread PARTICULAR USE SENSORS DP-101-N NPN open-collector transistor DP-101-N-P PNP open-collector transistor SIMPLE WIRE-SAVING UNITS DP-112A-E-P-J DP-102-N NPN open-collector transistor M5 female thread PNP open-collector transistor DP-102-N-P + NPT 1/8 NPN open-collector transistor DP-101A-N male thread PNP open-collector transistor DP-101A-N-P DP-102A-N NPN open-collector transistor DP-102A-N-P PNP open-collector transistor DP-101-M NPN open-collector transistor DP-101-M-P PNP open-collector transistor DP-102-M NPN open-collector transistor DP-102-M-P PNP open-collector transistor DP-101A-M M5 female thread NPN open-collector transistor DP-101A-M-P PNP open-collector transistor DP-102A-M NPN open-collector transistor DP-102A-M-P PNP open-collector transistor Type without connector attached cable SENSOR OPTIONS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Type without connector attached cable CN-14A-C2 is available. When ordering this type, suffix “-J” to the Model No. (Excluding M8 plug-in connector type and short pressure port type) (e.g.) Type without connector attached cable of DP-101-N is “DP-101-N-J” Accessory • CN-14A-C2 (Connector attached cable 2 m 6.562 ft) Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DP-0 DP-100 DP-M 721 Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 OPTIONS FIBER SENSORS LASER SENSORS Designation PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Model No. Connector attached cable AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Connector attached cable Bending-resistant cable ( ) M8 connector attached cable CN-14A-C1 CN-14A-C2 (Note) CN-14A-C3 CN-14A-C5 CN-14A-R-C1 CN-14A-R-C2 CN-14A-R-C3 CN-14A-R-C5 Length: 1 m 3.281 ft CN-24A-C2 Length: 2 m 6.562 ft CN-24A-C5 Length: 3 m 9.843 ft Length: 5 m 16.404 ft Length: 1 m 3.281 ft Length: 3 m 9.843 ft Length: 5 m 16.404 ft Set of 10 housings and 40 contacts MS-DP1-1 MS-DP1-5 Allows sensors to be installed on the wall. Multiple sensors can also be mounted closely. MS-DP1-2 Allows installation to panels with thickness of 1 to 6 mm 0.039 to 0.236 in. Multiple sensors can also be mounted closely. MS-DP1-4 Allows replacement from DP2 / DP3 series to DP-100 series. For newly designed set-up, please use panel mounting bracket MS-DP1-2 for panel mounting. MS-DP1-3 Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket MS-DP1-2) DPX-04 Protects the adjustment surfaces of sensors. (Can be attached when using the panel mounting bracket MS-DP1-4) Conversion bushing MS-DP1-7 By equipping with DP-10□-M(-P), pressure port can be converted to Rc1/8 female thread. Replacement from DP2 / DP3 series is possible. MS-DP1-FM MS-DP1-FR MS-DP1-FN MS-DP1-FE M5 female thread Flat attachment Sensor mounting bracket Panel mounting bracket Front protection cover M8 connector attached cable • CN-24A-C□ For M8 plug-in connector type The connector on one end Length: 5 m 16.404 ft Cable outer diameter: ø4 mm ø0.157 in Allows sensors to be installed on the flooring or ceiling. Multiple sensors can also be mounted closely. For DP-10□-M(-P) Pressure port and cable can now be pulled out in downward, left or right 1 NPT /8 female thread directions. Flat mounting on surfaces such as the wall is made possible. G1/8 female thread Rc1/8 female thread Note: The connector attached cable CN-14A-C2 is supplied with the DP-100 series. (Excluding M8 plug-in connector type). 31.4 1.236 • MS-DP1-2 • MS-DP1-3 • MS-DP1-4 Front protection cover DPX-04 (optional) can be installed on MS-DP1-4. Front protection cover MS-DP1-3 Sensor mounting bracket • MS-DP1-1 M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-1 ( ) Sensor mounting bracket MS-DP1-1 • MS-DP1-5 M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-5 ( DP2 / DP3 DP 2-2 0 ñ101 .3kP a OUT 1 OUT 2 0-AD J MOD E Remove Insert Panel mounting bracket MS-DP1-2 • MS-DP1-FM (Unit: mm in) ) Sensor mounting bracket MS-DP1-5 Remove DP-100 Flat attachment ø4 ø0.157 ø9 ø0.354 Panel mounting bracket, Front protection cover Flow DP-M 0.2 mm2 4-core bending-resistant cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in Length: 2 m 6.562 ft CN-14A Connector Pressure/ Head-separated DP-100 • CN-14A-C□ • CN-14A-R-C□ 0.2 mm2 4-core cabtyre cable with connector on one end Cable outer diameter: ø3.7 mm ø0.146 in Length: 2 m 6.562 ft Pressure/ Digital Display DP-0 Connector attached cable Description Mounting holes for DP2 / DP3 series can be used as is. Conversion bushing • MS-DP1-7 M5 female thread Rc1/8 female thread Panel mounting bracket MS-DP1-4 • MS-DP1-FR • MS-DP1-FN • MS-DP1-FE Conversion bushing MS-DP1-7 Recommended connector Net weight: MS-DP1-FM 15g approx. MS-DP1-FR/FN/FE 25g approx. Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. Contact: SPHD-001T-P0.5, Housing: PAP-04V-S (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended crimping tool Model No.: YC-610R (Manufactured by J.S.T. Mfg. Co., Ltd.) Note: Contact the manufacturer for details of the recommended products. Recommended connector (e-CON) Applicable connector: 37104-3122-000 FL (Manufactured by 3M Japan Limited) Note: Contact the manufacturer for details of the recommended products. Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 722 SPECIFICATIONS Standard Model No. Type Item FIBER SENSORS For low pressure DP-101(-M)(-P) DP-101-E-P DP-111-E-P-J DP-101-N(-P) Asia (Note 2) Europe M8 plug-in connector type North America (Note 2) For high pressure DP-102(-M)(-P) DP-102-E-P DP-112-E-P-J DP-102-N(-P) CE marking directive compliance MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Gauge pressure Rated pressure range −100.0 to +100.0 kPa −101.0 to +101.0 kPa −1.030 to +1.030 kgf/cm2 −1.010 to +1.010 bar −14.64 to +14.64 psi −757 to +757 mmHg −29.8 to 29.8 inHg Set pressure range 500 kPa Pressure withstandability −0.100 to +1.000 MPa −0.101 to +1.010 MPa −101 to +1,010 kPa −1.03 to +10.30 kgf/cm2 −1.01 to +10.10 bar −14.6 to +146.4 psi −100.0 to +100.0 kPa −101.0 to +101.0 kPa −1.030 to +1.030 kgf/cm2 −1.010 to +1.010 bar −14.64 to +14.64 psi −757 to +757 mmHg −29.8 to 29.8 inHg 1.5 MPa −0.100 to +1.000 MPa −0.101 to +1.010 MPa −101 to +1,010 kPa −1.03 to +10.30 kgf/cm2 −1.01 to +10.10 bar −14.6 to +146.4 psi 500 kPa Non-corrosive gas Selectable unit For low pressure: kPa, kgf/cm2, bar, psi, mmHg, inHg, For high pressure: MPa, kPa, kgf/cm2, bar, psi Supply voltage 12 to 24 V DC ±10 % Ripple P-P 10 % or less Normal operation: 720 mW or less (Current consumption 30 mA or less at 24 V supply voltage) ECO mode: 480 mW or less at STD (Current consumption 20 mA or less at 24 V supply voltage) 360 mW or less at FULL (Current consumption 15 mA or less at 24 V supply voltage) NPN open-collector transistor PNP open-collector transistor • Maximum sink current: 100 mA • Maximum source current: 100 mA • Applied voltage: 30 V DC or less (between comparative output and 0 V) • Applied voltage: 30 V DC or less (between comparative output and +V) • Residual voltage: 2 V or less (at 100 mA sink current) • Residual voltage: 2 V or less (at 100 mA source current) Output operation / Output modes PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS 1.5 MPa Applicable fluid Comparative output Comparative output 1, Comparative output 2 (Note 3) PHOTOELECTRIC SENSORS EMC Directive, RoHS Directive Type of pressure Power consumption LASER SENSORS Multi-function For low pressure For high pressure DP-101A(-M)(-P) DP-102A(-M)(-P) DP-101A-E-P DP-102A-E-P DP-111A-E-P-J DP-112A-E-P-J DP-101A-N(-P) DP-102A-N(-P) SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES NO/NC (selectable by key operation) / EASY mode / Hysteresis mode / Window comparator mode Hysteresis LASER MARKERS Minimum 1 digit (variable) (however, 2 digits when using psi unit) Repeatability ±0.1 % F.S. (within ±2 digits) Response time ±0.2 % F.S. (within ±2 digits) ±0.1 % F.S. (within ±2 digits) ±0.2 % F.S. (within ±2 digits) 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms, 5,000 ms, selectable by key operation Short-circuit protection Incorporated ON voltage: 0.4 V DC or less OFF voltage: 5 to 30 V DC, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more External input (Note 4) Auto-reference function / Remote zero-adjustment function PLC ON voltage: 5 V to +V DC OFF voltage: 0.6 V DC or less, or open Input impedance: 10 kΩ approx. Input time: 1 ms or more Analog voltage output (Note 4) Output voltage: 1 to 5 V DC Zero point: within 3 V ±5 % F.S. Span: within 4 V ±5 % F.S. Linearity: within ±1 % F.S. Output impedance: 1 kΩ approx. Output voltage: 0.6 to 5 V Zero point: within 1 V ±5 % F.S. Span: within 4.4 V ±5 % F.S. Linearity: within ±1 % F.S. Output impedance: 1 kΩ approx. Analog current output (Note 4) Output current: 4 to 20 mA Zero point: 12 mA ±5 % F.S. Span: 16 mA ±5 % F.S. Linearity: within ±1 % F.S. Load resistance: 250 Ω (max.) Output current: 2.4 to 20 mA Zero point: 4 mA ±5 % F.S. Span: 17.6 mA ±5 % F.S. Linearity: within ±1 % F.S. Load resistance: 250 Ω (max.) Display 4 digits + 4 digits 3-color LCD display (Display refresh rate: 250 ms, 500 ms, 1,000 ms, selectable by key operation) −101.0 to +101.0 kPa −101.0 to +101.0 kPa −0.101 to +1.010 MPa −0.101 to +1.010 MPa −1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa −1.030 to +1.030 kgf/cm2 −101 to +1,010 kPa 2 −1.010 to +1.010 bar −1.010 to +1.010 bar −1.03 to +10.30 kgf/cm −1.03 to +10.30 kgf/cm2 −14.64 to +14.64 psi −14.64 to +14.64 psi −1.01 to +10.10 bar −1.01 to +10.10 bar −757 to +757 mmHg −757 to +757 mmHg −14.6 to +146.4 psi −14.6 to +146.4 psi −29.8 to 29.8 inHg −29.8 to 29.8 inHg Displayable pressure range Environmental resistance Indicator ( Orange LED Comparative output 1 operation indicator, comparative output 2 operation indicator: Lights up when each comparative output is ON Ambient humidity Voltage withstandability Insulation resistance Vibration resistance Shock resistance )( Material Connecting method / Cable length Weight Accessories ) 1,000 V AC for one min. between all supply terminals connected together and enclosure 100 m/s2 acceleration (10 G approx.) in X, Y and Z directions three times each Asia: M5 female thread + R (PT) 1/8 male thread [excluding DP-□-M(-P)], Europe: M5 female thread + G 1/8 male thread, North America: M5 female thread + NPT 1/8 male thread Within ±1 % F.S. (at +20 °C +68 °F) Within ±0.5 % F.S. (at +20 °C +68 °F) UV CURING SYSTEMS Flow 50MΩ or more with 500 V DC megger between all supply terminals connected together and enclosure 10 to 500 Hz frequency, 3 mm 0.118 in double amplitude or maximum acceleration 196 m/s2, in X, Y and Z directions for two hours each (when panel is mounted: 10 to 150 Hz frequency, 0.75 mm 0.030 in amplitude or maximum acceleration 49 m/s2, in X, Y and Z directions for two hours each) Pressure port MACHINE VISION SYSTEMS Pressure/ Head-separated 35 to 85 % RH (No dew condensation or icing allowed), Storage: 35 to 85 % RH Within ±0.5 % F.S. (at +20 °C +68 °F) FA COMPONENTS Pressure/ Digital Display −10 to +50 °C +14 to +122 °F, Storage: −10 to +60 °C +14 to +140 °F Temperature characteristics ENERGY MANAGEMENT SOLUTIONS Selection Guide IP40 (IEC) Protection Ambient temperature Orange LED Comparative output 1 operation indicator: Lights up when comparative output is ON, Analog voltage output operation indicator: Lights up when setting HUMAN MACHINE INTERFACES Within ±1 % F.S. (at +20 °C +68 °F) Enclosure: PBT (glass fiber reinforced), LCD display: Acrylic, Pressure port: Stainless steel (SUS303) , Mounting threaded part: Brass (nickel plated), Switch part: Silicone rubber Connector / Total length up to 100 m 328.084 ft (less than 30 m 98.425 ft when conforming to CE marking) is possible with 0.3 mm2, or more, cable. Net weight: 40 g approx. (DP-10□-M(-P): 30 g approx.), Gross weight: 130 g approx. (DP-10□-M(-P):120 g approx.) CN-14A-C2 (Connector attached cable 2 m 6.562 ft): 1pc. (excluding M8 plug-in connector type) Notes: 1) Where measurement conditions have not been specified precisely, the conditions used were an ambient temperature of +20 °C +68 °F. 2) Model Nos. of Asia type having “-M” are short pressure port type. Model Nos. of Asia and North America types having the suffix “-P” are PNP output type. 3) Only standard type is equipped with comparative output 2. 4) Cannot be used at the same time. DP-0 DP-100 DP-M 723 Dual Display Digital Pressure Sensor I/O CIRCUIT AND WIRING DIAGRAMS FIBER SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS I/O circuit diagrams ZD1 PARTICULAR USE SENSORS SENSOR OPTIONS D3 (Black) Load Comparative output 1 2 5V Load 100 mA max. (White) Comparative output 2 3 Internal circuit PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Pressure/ Head-separated Flow Standard type Designation 1 +V Comparative output 1 + − ZD1 Tr1 D 100 mA max. Users’ circuit Standard type: Comparative output 2 Multi-function type: Analog output or External input 4 0V Tr2 2 + (Black) Comparative output 1 100 mA max. 3 (White) Comparative output 2 (Blue) 0 V Internal circuit − Load 12 to 24 V DC ±10 % Tr2 3 D2 Internal circuit Terminal arrangement diagram 3 D3 1kΩ (Black) Comparative output 1 (White) Analog output Load or External input + − (Blue) 0 V Users’ circuit Designation 1 +V 2 Comparative output 1 3 Standard type: Comparative output 2 Multi-function type: Analog output or External input 4 0V DP-11□-E-P-J PNP output type I/O circuit diagrams Standard type ZD1 Tr1 D 1 Multi-function type Terminal No. Color code of connection cable (Brown) +V D1 100 mA max. ZD2 Tr2 4 2 3 Internal circuit + (Black) Comparative output 1 100 mA max. (White) Comparative output 2 (Blue) 0 V Load − Terminal arrangement diagram 4 1 Tr2 D2 Internal circuit Terminal (Brown) +V 100 mA max. 4 1k 2 3 Users’ circuit 2 12 to 24 V DC ±10 % Terminal No. Color code of connection cable ZD Tr1 Load Symbols • • • D : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : PNP output transistor 3 12 to 24 V DC ±10 % Symbols • • • D1 to D3 : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr1 : PNP output transistor Tr2 : NPN input transistor Terminal 4 (Brown) +V 100 mA max. 2 4 Users’ circuit 2 ZD Tr1 1 D1 Load Symbols • • • D : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : PNP output transistor 1 Terminal No. Color code of connector attached cable Multi-function type Terminal No. Color code of connector attached cable 100 mA max. ZD2 1 12 to 24 V DC ±10 % (Blue) 0 V 3 (Brown) +V 1 4 Sensor circuit DP-M (Black) Comparative output 1 Symbols • • • D1 to D3 : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr1 : PNP input transistor Tr2 : NPN output transistor Terminal 4 (White) Analog output or External input Load PNP output type I/O circuit diagrams DP-0 DP-100 3 2 (Brown) +V DP-10□-P Selection Guide Pressure/ Digital Display 2 D2 1kΩ ZD Users’ circuit 2 Sensor circuit LASER MARKERS Tr2 3 4 Terminal arrangement diagram 1 Tr1 Internal circuit Symbols • • • D1 to D3 : Reverse supply polarity protection diode ZD1, ZD2 : Surge absorption zener diode Tr1, Tr2 : NPN output transistor WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES − 12 to 24 V DC ±10 % 1 D1 D3 (Blue) 0 V 4 SIMPLE WIRE-SAVING UNITS MEASUREMENT SENSORS + 100 mA max. ZD2 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS D2 Tr1 Tr2 (Brown) +V 1 D1 Terminal No. Color code of connector attached cable Multi-function type Terminal No. Color code of connector attached cable Standard type Sensor circuit AREA SENSORS NPN output type Sensor circuit MICRO PHOTOELECTRIC SENSORS DP-10□ Sensor circuit PHOTOELECTRIC SENSORS Sensor circuit LASER SENSORS DP-100 SERIES Ver.2 (Black) Comparative output 1 (White) Analog voltage output Load or External input Users’ circuit Symbols • • • D1, D2 : Reverse supply polarity protection diode ZD : Surge absorption zener diode Tr1 : PNP output transistor Tr2 : NPN input transistor Designation +V 2 Standard type: Comparative output 2 Multi-function type: Analog output or External input 4 − (Blue) 0 V 1 3 + 0V Comparative output 1 12 to 24 V DC ±10 % Dual Display Digital Pressure Sensor PRECAUTIONS FOR PROPER USE • Never use this product as a sensing device for personnel protection. • In case of using sensing devices for personnel protection, use products which meet laws and standards, such as OSHA, ANSI or IEC etc., for personnel protection applicable in each region or country. • The DP-100 series is designed for use with non-corrosive gas. It cannot be used with liquid or corrosive gas. DP-100 SERIES Ver.2 Refer to p.1566 for general precautions. • The MS-DP1-4 panel mounting bracket is available when switching from the DP2 / DP3 series. DP2 / DP3 DP 2-2 0 ñ10 1.3k Front protective cover DPX-04 (optional) can be installed on MS-DP1-4. Pa OUT Remove 1 OUT 2 0-AD J MO DE DP-100 Sub display PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS Mounting holes for DP2 / DP3 series can be used as is. Panel mounting bracket MS-DP1-4 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS Mode selection Decrement key key Increment key Wiring • Make sure that the power supply is off while wiring. • Verify that the supply voltage variation is within the rating. • If power is supplied from a commercial switching regulator, ensure that the frame ground (F.G.) terminal of the power supply is connected to an actual ground. • In case noise generating equipment (switching regulator, inverter motor, etc.) is used in the vicinity of this sensor, connect the frame ground (F.G.) terminal of the equipment to an actual ground. • Do not run the wires together with high-voltage lines or power lines or put them in the same raceway. This can cause malfunction due to induction. • Incorrect wiring will cause problems with operation. Connection • Do not apply stress directly to the connection cable leader or to the connector. Connector attached cable [CN-14A(-R)-C□] Mounting • MS-DP1-1 / MS-DP1-5 sensor mounting brackets are available separately, and it should be used for mounting. When tightening the sensor to the sensor mounting bracket, use a tightening torque of 0.5 N·m or less. • An conversion bushing is available for when using the DP-10□-M short pressure port type. It can be used to switch between this model and the DP2 / DP3 series. When connecting to the pressure port, use a M5 female thread Rc 1 8 female thread tightening torque of 1.0 N·m or less. SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS Conversion bushing MS-DP1-7 • The MS-DP1-F□ flat attachment is available for when using the DP-10□-M short pressure port type. If using the MS-DP1-F□ flat attachment (optional), install by following the procedures given below. 1 Decide the direction of this product to mount with the sensor. STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS Pressure port faces downward Pressure port faces leftward Pressure port faces rightward Note: It is not possible to mount this product such that the pressure port faces upward. 2 Mount this product with the M3 female threads of the sensor by using the attached M3 (length 8 mm 0.315 in) screws. The tightening torque should be 0.5 N·m or less. M3 female thread ) FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Pressure port faces upward M3 (length 6 mm 0.236 in) screws with washers Accessory for MS-DP1-1 and MS-DP1-5 ( LASER SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS Insert Main display FIBER SENSORS AREA SENSORS Remove Part description Comparative output 1 operation indicator Comparative output 2 operation indicator Work as analog voltage output operation indicator in Multi-function type 724 M3 (length 8 mm 0.315 in) screw (Accessory) Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DP-0 Sensor mounting bracket MS-DP1-1 (Optional) DP-100 M3 female thread DP-M 3 • The MS-DP1-2 panel mounting bracket (optional) and the MS-DP1-3 front protection cover (optional) are also available. Mount this product with the mounting surface by using the attached M4 (length 20 mm 0.787 in) screws. The tightening torque should be 1.2 N·m or less. Groove Front protection cover MS-DP1-3 (optional) Connector attached cable M4 (length 20 mm 0.787 in) screw (Accessory) Note: Take care that if the cable with connector is sticking out of the side groove of this product when mounting, the cable may disconnected. Panel mounting bracket MS-DP1-2 (optional) 725 FIBER SENSORS LASER SENSORS PHOTOELECTRIC SENSORS MICRO PHOTOELECTRIC SENSORS AREA SENSORS SAFETY LIGHT CURTAINS / SAFETY COMPONENTS PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS PARTICULAR USE SENSORS SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES Dual Display Digital Pressure Sensor DP-100 SERIES Ver.2 PRECAUTIONS FOR PROPER USE Conditions in use for CE conformity • The DP-100 series is a CE conformity product complying with EMC Directive. The harmonized standard with regard to immunity that applies to this product is EN 61000-6-2 and the following condition must be met to conform to that standard. Condition • The line to connect with this sensor should be less than 30 m 98.425 ft. Piping 12 mm 0.472 in • If connecting a commercially-available spanner coupling to the pressure port, attach a 12 mm 0.472 in spanner (14 mm 0.551 in spanner for DP-100-E type) to the hexagonal section of the pressure port to secure it, and tighten at a torque of 9.8 N·m or less. If it is tightened using excessive torque, it may damage the coupling or the pressure port. In addition, wrap sealing tape around the coupling when connecting it to prevent leaks. • If connecting a commercially-available joint to the pressure port of the DP-10□-M(-P), hold the main unit in your hand to steady it, and tighten to a torque of 1.0 N·m or less. If it is tightened to an excessive torque, the joint or the main unit may become damaged. • If connecting a commercially-available joint to the pressure port of the MS-DP1-7, tighten to a torque of 9.8 N·m or less. 14 mm 0.551 in spanner ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS • The tightening torque should be 1 N·m or less when connecting a coupling to the pressure port of MS-DP1-FM. Selection Guide Pressure/ Digital Display Pressure/ Head-separated Flow DP-0 DP-100 DP-M Pressure port Coupling (Purchase separately.) • When connecting the coupling to the pressure port of MS-DP1-FR/FE/FN, hold the pressure port with a 14 mm 0.551 in spanner and make sure that the tightening torque is 9.8 N·m or less. In addition, in order to prevent any leakage, wind a sealing tape on the coupling when connecting. 14 mm 0.551 in spanner Note: Do not tighten the pressure port by holding the product with the spanner. It may cause the product breakage. Refer to p.1566 for general precautions. Flat attachment • Make sure to mount MS-DP1-F□ with the sensor properly. If it is not mounted properly, air leakage may occur. • Take care that the excessive mounting and dismounting of this product may cause deterioration of the O-ring. • If you touch the O-ring of MS-DP1-F□, or any scratch or dust, etc. is attached to it, air leakage may occur and the sensing performance may deteriorate. Take sufficient care when using and storing MS-DP1-F□. Others • Use within the rated pressure range. • Do not apply pressure exceeding the pressure withstandability value. The diaphragm will get damaged and correct operation shall not be maintained. • Do not use during the initial transient time (0.5 sec. approx.) after the power supply is switched on. • Avoid dust, dirt, and steam. • Take care that the sensor does not come in direct contact with water, oil, grease, or organic solvents, such as, thinner, etc. • Do not insert wires, etc., into the pressure port. The diaphragm will get damaged and correct operation shall not be maintained. • Do not operate the keys with pointed or sharp objects. RUN mode • This is the normal operating mode. Setting item Description Threshold value setting The threshold values for ON/OFF operation can be changed directly by pressing the increment key (UP) and the decrement key (DOWN). Zero-adjustment function This forces the pressure value display to be reset to zero when the pressure port is open on the atmospheric pressure side. Key lock function Stops key operations from being accepted. Peak hold / bottom hold function Displays the peak value and bottom value for fluctuating pressure. The peak value appears in the main display, and the bottom value appears in the sub display. MENU SETTING mode • If the mode selection key is pressed and held for 2 seconds in RUN mode, the mode will switch to MENU SETTING mode. • If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Setting item Comparative output 1 output mode setting Description Sets the output mode for comparative output 1. Comparative output 2 output mode Sets the output mode for comparative output 2. setting (standard type only) Analog output / external input switching (multi-function type only) Allows switching between analog voltage output / analog current output, and auto-reference input / remote zero-adjust-ment input. NO/NC switching Sets normally open (NO) or normally closed (NC). Response time setting Sets the response time. The response time can be selected from 2.5 ms, 5 ms, 10 ms, 25 ms, 50 ms, 100 ms, 250 ms, 500 ms, 1,000 ms and 5,000 ms. Display color switching for main display Allows the color for the main display to be changed. The colors can be set to ‘red / green’ or ‘green / red’ to correspond to ON/OFF output, or it can be fixed at ‘red’ or ‘green’ all the time. Unit switching Pressure unit can be changed. Dual Display Digital Pressure Sensor PRECAUTIONS FOR PROPER USE Sub display switching Display refresh rate switching Changes the display refresh rate for the pressure value displayed in the main display. Hysteresis fix value switching Sets the hysteresis for EASY mode and window comparator mode. (8 steps) Linked display color switching (standard type only) Allows the display color for the main display to be switched in line with the output operation for comparative output 1 or comparative output 2. ECO mode setting Allows power consumption to be reduced by dimming the display or turning it off. Setting check code Allows the setting details to be checked via codes. Setting copy mode Allows the setting details for the master sensor to be copied to slave sensors. Reset setting Resets the settings to the factory settings. Code Standard type Hysteresis NO OFF NC EASY NO NC Window comparator NC — — — NO NC NO Hysteresis NO — OFF Window comparator NC — ADJ. NO — — NC — — — — — — Comparative output 1 Comparative output 2 Comparative output 1 Comparative output 2 Comparative Always output 1 red Comparative output 2 Comparative Always output 1 green Comparative output 2 Analog voltage P-1, Lo-1 Red output when ON Autoreference Hi-1 Remote zero-adjustment P-2, Lo-2 Green when ON Analog current Hi-2 output 20 0.787 7.5 9.5 0.295 0.374 R (PT) 1/ 8 male thread (North America: NPT 1/ 8) 1.5 0.059 5th digit Response time 2.5 ms 5 ms 10 ms 25 ms 50 ms 100 ms 250 ms 500 ms 1,000 ms 5,000 ms 6th digit Unit switching MPa kPa kgf/cm2 bar psi mmHg inchHg — — — Connector 12 0.472 7th digit Display refresh rate 250 ms 500 ms 1,000 ms — — — — — — — 8th digit ECO mode OFF STD FULL — — — — — — — Europe 14 0.551 G 1/ 8 male thread 20 0.787 M5 female thread, 4 0.157 deep DP-11□-E-P-J Sensor 20 0.787 7 0.276 9.5 0.374 4.5 0.177 1.5 0.059 15 0.591 SENSOR OPTIONS SIMPLE WIRE-SAVING UNITS LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Pressure/ Digital Display DP-0 DP-100 connector M3 female thread, 4 0.157 deep 30 1.181 PARTICULAR USE SENSORS DP-M ø8.3 ø0.327 47.5 25.5 1.870 1.004 INDUCTIVE PROXIMITY SENSORS Flow 20 0.787 4.5 0.177 1.5 0.059 PRESSURE / FLOW SENSORS Pressure/ Head-separated Sensor 30 1.181 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 10 7 0.394 0.276 M5 female thread M3 female thread, 4 0.157 deep DP-10□-M(-P) 30 1.181 25.5 1.004 AREA SENSORS STATIC CONTROL DEVICES Code 25.5 1.004 MICRO PHOTOELECTRIC SENSORS MEASUREMENT SENSORS Sensor 42.5 1.673 PHOTOELECTRIC SENSORS WIRE-SAVING SYSTEMS 20 0.787 30 1.181 4th digit Standard type only The CAD data can be downloaded from the website. 30 1.181 30 1.181 Multi-function 3rd digit type Comparative output 2 NO/NC Analog voltage output / Threshold Display color for Display Comparative output 1 NO/NC switching output mode switching External input value display main display color linking output mode DIMENSIONS (Unit: mm in) 30 1.181 2nd digit 1st digit EASY FIBER SENSORS LASER SENSORS Table of codes Description Changes the information in the sub display during RUN mode operation to the desired alphanumeric display. DP-10□(-P) 726 Refer to p.1566 for general precautions. PRO mode • If the mode selection key is pressed and held for 5 seconds in RUN mode, the mode will switch to PRO mode. • If the mode selection key is pressed while a setting is being made, the mode will switch to RUN mode. In this case, the settings that have been changed will be entered. Setting item DP-100 SERIES Ver.2 G 1/8 male thread 7 0.276 20 0.787 M8 connector 14 0.551 M5 female thread M3 female thread, 4 0.157 deep 727 FIBER SENSORS LASER SENSORS Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) Sensor mounting bracket (Optional) Assembly dimensions ø2.3 ø0.091 MICRO PHOTOELECTRIC SENSORS 9.5 14.5 0.571 0.374 AREA SENSORS 22 0.866 30 1.181 20 0.787 13 0.512 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS SENSOR OPTIONS 22 0.866 14.5 0.571 4.2 0.165 2-ø3.5 ø0.138 25.5 1.004 42.5 1.673 9.5 0.374 7.5 0.295 5.3 (0.209 ) 5.5 0.217 20 0.787 2-R2.1 R0.083 9.5 0.374 2-R2.1 R0.083 R13 20 0.787 R0.512 t2 t 0.079 Mounting drawing with DP-10□(-P) 1 0.039 4.2 0.165 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS SIMPLE WIRE-SAVING UNITS The CAD data can be downloaded from the website. MS-DP1-1 PHOTOELECTRIC SENSORS PARTICULAR USE SENSORS DP-100 SERIES Ver.2 45 1.772 44 1.732 30 1.181 45 1.772 12 0.472 30 1.181 15 0.591 1.5 0.059 30 1.181 Material: Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) t2 t 0.079 Two M3 (length 6 mm 0.236 in) screws with washers are attached. WIRE-SAVING SYSTEMS MEASUREMENT SENSORS STATIC CONTROL DEVICES LASER MARKERS PLC HUMAN MACHINE INTERFACES ENERGY MANAGEMENT SOLUTIONS FA COMPONENTS MS-DP1-5 Sensor mounting bracket (Optional) Assembly dimensions Mounting drawing with DP-10□-M(-P) R6.75 R0.266 22.75 0.896 29.5 1.161 20 0.787 4.5 0.177 16 0.630 28 1.102 8.5 0.335 30 1.181 4.5 0.177 44.5 30 1.752 1.181 20 0.787 MACHINE VISION SYSTEMS UV CURING SYSTEMS ø4.5 ø0.177 13.5 0.531 20 0.787 2-ø3.5 ø0.138 49.5 (1.949 ) t 1.5 t 0.059 ø8.3 ø0.327 20 49.5 0.787 28.5 1.949 1.122 ø4.5 ø0.177 Material: Stainless steel (SUS304) 20 0.787 29.5 1.161 30 1.181 Two M3 (length 6 mm 0.236 in) screws with washers are attached. MS-DP1-2 MS-DP1-3 1.5 0.059 28 1.102 53.5 2.106 4.5 0.177 t 1.5 t 0.059 Panel mounting bracket (Optional), Front protection cover (Optional) Selection Guide Assembly dimensions Pressure/ Digital Display Mounting drawing with DP-10□(-P) Panel cut-out dimensions Pressure/ Head-separated When 1 unit is installed 0 31−0.4 0 1.220 −0.016 Flow 0 DP-0 39.3 ( 1.547 ) DP-100 34.5 1.358 DP-M ( 34.5 20 1.358 0.787 7.2 0.283 11 0.433 Front protection cover ) 50 1.969 33.4 1.315 31−0.4 0 1.220 −0.016 (Note 2) 9.5 18.3 7.5 0.374 0.720 0.295 8.7 0.343 When “n” units are installed horizontally in series When “n” units are installed vertically in series 0 12 (Note 2) 0.472 R 1/ 8 male thread (Note 1) 31−0.4 0 1.220 −0.016 31 1.220 Xn + 3.5 0.138 X (n-1) 0 31−0.4 0 1.220 −0.016 55 2.165 or more Panel thickness dimension 1 to 6 mm 0.039 to 0.236 in Connector 33.4 1.315 M5 female thread, 4 0.157 deep (52 2.047 max) View A M3 female thread, 4 0.157 deep 31 1.220 Xn + 3.5 0.138 X (n-1) Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. 55 2.165 or more Note: The panel thickness should be 1 to 6 mm 0.039 to 0.236 in. Material: Polyacetal (Panel mounting bracket) Polycarbonate (Front protection cover) Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N (-P)has a NPT1/8 male thread. 2) In case of DP-10□-E-P, the dimension 7.5 become to be 10, the dimension 9.5 become to be 7 and the dimension 12 become to be 14. Dual Display Digital Pressure Sensor DIMENSIONS (Unit: mm in) DP-100 SERIES Ver.2 728 The CAD data can be downloaded from the website. MS-DP1-4 Panel mounting bracket (Replacement from conventional model) (Optional) Assembly dimensions ( 42.7 1.681 40 1.575 30 1.181 ) 36 1.417 26.5 1.043 6.5 0.256 3 0.118 (0.3829.7) 40 30 1.575 1.181 Front protection cover (DPX-04) Panel thickness dimension 1 to 3.2 mm 0.039 to 0.126 in 36 1.417 M5 female thread Panel mounting bracket body 8 0.315 AREA SENSORS Connector 12 0.472 42.7 1.681 MICRO PHOTOELECTRIC SENSORS 56 2.205 R 1/ 8 male thread (Note 1) Spacer +0.5 0 +0.020 0 SAFETY LIGHT CURTAINS / SAFETY COMPONENTS 36 +0.5 0 1.417+0.020 0 80 3.150 PRESSURE / FLOW SENSORS INDUCTIVE PROXIMITY SENSORS Panel mounting bracket PARTICULAR USE SENSORS Material: Nylon 6 (Panel mounting bracket body) Stainless steel (SUS304) (Panel mounting bracket) Cold rolled carbon steel (SPCC) (Trivalent uni-chrome plated) (Spacer) SENSOR OPTIONS Notes: 1) DP-10□-E-P has a G1/8 male thread. DP-10□-N (-P)has a NPT1/8 male thread. 2) The panel tickness should be 1 to 32 mm 0.039 to 1.260 in. MS-DP1-FM Flat attachment (Optional) SIMPLE WIRE-SAVING UNITS MS-DP1-FR/FN/FE Flat attachment (Optional) Assembly dimensions Assembly dimensions Mounting drawing with DP-10□-M(-P) Mounting drawing with DP-10□-M(-P) 44.5 (1.752 ) 24 (0.945 ) 37 1.457 11.5 0.453 30 1.181 44.5 1.752 6.5 0.256 5.5 0.217 20 0.787 24 0.945 30 1.181 2-ø4.3 ø0.169 24 0.945 PLC HUMAN MACHINE INTERFACES 24 0.945 Material: Polybutylene terephthalate (PBT) (Glass fiber reinforced) (Enclosure) Stainless steel (SUS303) (Pressure port) Hydrogenated Nitrile Butadiene Rubber (H-NBR) (O-ring) Weight: 15 g approx. (flat attachment only) 14 0.551 20 0.787 24 0.945 30 1.181 2-ø4.3 ø0.169 Pressure port G1/8 female thread (Note) Two M3 (length 8 mm 0.315 in) screws, 8.5 0.335 two M4 (length 20 mm 0.787 in) screws are attached. MEASUREMENT SENSORS LASER MARKERS 11.5 0.453 6.5 0.256 5.5 0.217 13.5 0.531 17.5 0.689 M5 female thread 37 1.457 11 0.433 30 1.181 52.5 2.067 WIRE-SAVING SYSTEMS STATIC CONTROL DEVICES 52.5 ( 2.067 ) 24 (0.945 ) 11 0.433 LASER SENSORS PHOTOELECTRIC SENSORS Panel cut-out dimensions Mounting drawing with DP-10□(-P) FIBER SENSORS ENERGY MANAGEMENT SOLUTIONS Product distinguishing mark MS-DP1-FR: 0 line MS-DP1-FN: 1 line MS-DP1-FE: 2 line FA COMPONENTS 8.5 0.335 17.5 0.689 Material: Polybutylene terephthalate (PBT) (Glass fiber reinforced) (Enclosure) Stainless steel (SUS303) (Pressure port) Hydrogenated Nitrile Butadiene Rubber (H-NBR) (O-ring) Weight: 25 g approx. (flat attachment only) Two M3 (length 8 mm 0.315 in) screws, two M4 (length 20 mm 0.787 in) screws are attached. MACHINE VISION SYSTEMS UV CURING SYSTEMS Selection Guide Note: MS-DP1-FR has a Rc1/8 female thread. MS-DP1-FN has a NPT1/8 female thread. Pressure/ Digital Display Pressure/ Head-separated Flow MS-DP1-7 Conversion bushing (Optional) CN-14A(-R)-C□ 15.8 0.622 (0.3158 ) ( 35 1.378 ) Connector attached cable (Optional, CN-14A-C2 is attached to the sensor) ( 0.5 0.020 11 0.433 ) 10 0.394 7.8 0.307 M5 male thread Gasket ( 50 1.969 ø3.7 ø0.146 cable • Length L Model No. 8 0.315 Rc1/8 female thread Material: Brass (Nickel plated) Weight: 10 g approx. DP-100 DP-M L 14 0.551 3.5 0.138 DP-0 Length L (mm in) CN-14A(-R)-C1 1,000 39.370 CN-14A(-R)-C2 2,000 78.740 CN-14A(-R)-C3 3,000 118.110 CN-14A(-R)-C5 5,000 196.850 ) (0.3158 )
DP-102-J 价格&库存

很抱歉,暂时无法提供与“DP-102-J”相匹配的价格&库存,您可以联系我们找货

免费人工找货