T1/CEPT PULSE TRANSFORMER
UL 1459 Recognized
Turns Ratio ( + 5% )
R
1:0.5:0.5
Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. Temperature Characteristics: -40o C 900 µH min. (40% drop in inductance) +85o C 1.7 mH min. (15% growth in inductance) Typical part: 2.0 mH @ +25o C 2.3 mH @ +85o C 1.2 mH @ -40o C
PARAMETER
1
MIN. 1.5
MAX.
UNITS mHy µHy µHy
Open Circuit Inductance
1
Primary Leakage Inductance
0.3
1
Secondary Leakage Inductance
0.4
1
Interwinding Capacitance (CW/W)
18 0.7 0.5 1.5 Kv 16
pF ohms ohms VRMS V-µS
Primary DC Resistance Secondary DC Resistance Isolation (HI-POT) E.T.
Parts shipped in anti-static tubes. 50 pieces per tube
*Primary Pins 5-6. A center tap can be formed by shorting pins 1+4 creating a 1:1CT Transformer.
1
PHYSICAL DIMENSIONS All dimensions in inches (mm):
Tested at 772 kHz & 100 mV
SCHEMATIC DIAGRAM:
RHOMBUS INDUSTRIES INC. FSCM NO. 16714
RHOMBUS P/N: T-10221 CUST P/N: 11/04/97 DATE: NAME: SHEET: 1 OF 1
Rhombus Industries Inc.
Transformers & Magnetic Products
15801 Chemical Lane, Huntington Beach, CA 92649 Phone: (714) 898-0960 FAX: (714) 896-0971
www.rhombus-ind.com
很抱歉,暂时无法提供与“T-10221”相匹配的价格&库存,您可以联系我们找货