10BASE-T INTERFACE TRANSFORMER
Reinforced Insulation Per EN 41003/EN 60950
Turns Ratio ( + 5% )
Parameter Min.
1CT:2.5CT
Max. Units
Meets IEE 802.3 and ANSI X3.263 Standards. Transformer can be used for Transmit or Receive side. Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. 0.5mm minimum insulation thickness between primary and secondary. Parts shipped in anti-static tubes. 31 pieces per tube
Open Circuit Inductance Leakage Inductance Interwinding Capacitance (CW/W) Primary DC Resistance Secondary DC Resistance Isolation (HI-POT)
200 0.7 15 0.4 0.8 4000
µH µH pF ohms ohms V RMS
OPERATING TEMPERATURE RANGE: -400C TO +850C
Physical Dimensions inches (mm)
Schematic Diagram
Leads are #22 AWG solderable
PRELIMINARY!
RHOMBUS P/N: T-1481 CUST P/N: DATE: 10/05/01 NAME: SHEET: 1 OF 1
R hombus Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 FAX: (714) 896-0971