10BASE-T INTERFACE TRANSFORMER
Reinforced Insulation Per EN 41003/EN 60950
Turns Ratio ( + 5% )
Parameter Min.
1CT:2.5CT
Max. Units
Meets IEE 802.3 and ANSI X3.263 Standards. Transformer can be used for Transmit or Receive side. Flammability: Materials used in the production of these units meet requirements of UL94-VO and IEC 695-2-2 needle flame test. 0.5mm minimum insulation thickness between primary and secondary. Parts shipped in anti-static tubes. 31 pieces per tube
Open Circuit Inductance Leakage Inductance Interwinding Capacitance (CW/W) Primary DC Resistance Secondary DC Resistance Isolation (HI-POT)
200 0.7 15 0.4 0.8 4000
µH µH pF ohms ohms V RMS
OPERATING TEMPERATURE RANGE: -400C TO +850C
Physical Dimensions inches (mm)
.560 (14.22) MAX. .400 (10.16) MAX. .010 (0.25) TYP. .035 (0.89) TYP. .110 (2.79) TYP. .740 (18.80) .710 (18.03) .560 (14.22) MAX.
Schematic Diagram
PRI 1 SEC 10
3
8
.020 .100 (0.51) (2.54) TYP. TYP.
5
6
10
6
PRELIMINARY!
RHOMBUS P/N: T-1481G
1 5
CUST P/N: DATE: 10/05/01
NAME: SHEET: 1 OF 1
R hombus Industries Inc.
Transformers & Magnetic Products
www.rhombus-ind.com
15801 Chemical Lane, Huntington Beach, CA 92649-1595 Phone: (714) 898-0960 FAX: (714) 896-0971