BP5013

BP5013

  • 厂商:

    ROHM(罗姆)

  • 封装:

    -

  • 描述:

    IC AC/DC CONV ZC NONISO

  • 数据手册
  • 价格&库存
BP5013 数据手册
Data Sheet Non-Isolated AC/DC Converter with Built-In Zero Cross Signal Output BP5013 Absolute Maximum Ratings Parameter Input voltage Zero-cross input voltage Operating temperature range Storage temperature range Maximum surface temperature Maximum output power Symbol Vi V1 Topr Tstg Tsmax Po Limits −170 120 −20 to +85 −25 to +105 105 12 Unit V Vrms °C °C °C W 220VAC Input/12W Output Dimensions (Unit : mm) 38.5MAX. 11.2MAX. MARKING SIDE 1 3 6 0.5±0.1 1.3±0.2 2.54±0.2 3.25MAX 8 9 10 11 12 13 14 0.25±0.05 3.65MAX. 7.55MAX. 2.54�13=33.02TYP 23.2MAX. Electrical Characteristics Symbol Min. Parameter −113 Input voltage range Vi −11 Output voltage Vo − Output current Io − Line regulation Vr − Load regulation Vl − Output ripple voltage Vp 75 Power conversion efficiency η 0 Zero-cross signal H VzH −4.6 Zero-cross signal L VzL (Vo=12V, R2=open) (Unless otherwise specified, Ta=25°C, Vi= −141V, Io=1000mA, V2=−5V,R1=10kΩ) Typ. −141 −12 − 0.03 0.13 0.22 83 − −5.0 Max. −170 −13 1000 0.2 0.2 0.35 − −0.3 −5.3 Unit V V mA V V Vp-p % V V Conditions DC − − Vi= −113 to −170V Io=0 to 1000mA − − V1 = −141V V1=0V Derating Curve Output Power (W) 4.0±1.0 ∗1 ∗2 Derating Curve 14 12 10 8 6 Operation Range 4 2 0 -30 -20 -10 0 10 20 30 40 50 60 70 80 90 100 Ambient Temperature Ta (°C) ∗1 Max output current should be reduced according to the surrounding temperature. ∗2 The output ripple voltage may vary depending on the capacitance, environment, and location of peripheral components. Conversion Efficiency 100 90 80 70 60 50 40 30 20 10 0 Conversion Efficiency (Vi=-141V, R2=open, Ta=25°C) Conversion Efficiency (%) Application Circuit Pin No. 1 2 3 4 5 6 7 8 9 10 11 12 13 14 Function Zero-cross input 1 (ACin) Skip Input (Vi) Skip Skip Coil 1 (Coil-1) Skip Coil 2 (Coil-2) Output (Vo) ADJ (VoADJ) Common Test Zero-cross signal output (Zcout) Zero-cross signal input (-5V) (Zc) BP5013 Be sure to use a fuse for safety 1 3 F1 AC100V D1 − ZNR C1 + C3 R3 L1 D2 − + C2 R1 V2=−5V Vo 6 8 9 10 11 12 13 14 14 0 R2 Zero-cross signal Io 200 400 600 800 Output Current Io (mA) 1000 Load Regulation -14.0 Output Voltage Vo (V) -12.0 -10.0 -8.0 -6.0 -4.0 -2.0 0.0 0 200 400 600 800 1000 1200 1400 Output Current Io (mA) Maximum Io=1000mA Load Regulation (Vi=-141V, R2=open, Ta=25°C) Coil start Please verify operation and characteristics in the customer's circuit before actual usage. Ensure that the load current does not exceed the maximum rating. External Component Specifications F1: FUSE C1: Input capacitor C2: Output capacitor C3: Noise removal capacitor R3 : Noise removal resistor D1: Rectifier diode D2: Flywheel Diode L1: Power inductor ZNR: Varistor R1: Pull-up resister R2: Output voltage setting resistor Use a fast-acting fuse of 2.0A. Rated voltage : Beyond 250V, capacitance : 47 to 220µF Rated ripple current : 0.22Arms or higher Rated voltage : Please ensure a rated voltage (whose value is proportional to the output voltage) with sufficient margin capacitance : 330 to 1000µF, low impedance type ESR : Less than 0.08Ω Rated ripple current : Byond 1.0Arms Evaluate under actual operating conditions since it affects the output ripple voltage. Rated voltage : Beyond 250V, Capacity : 0.1 to 0.22µF Film or ceramic capacitor Resistance : 10 to 22Ω, Power : More than 1/4W Peak reverse voltage : More than 400V Mean rectifying current : More than 1.0A Peak forward surge current : More than 20A Full-wave rectification can be used. Peak reverse voltage : More than 400V Mean rectifying current : More than 3.0A, Fast recovery diode Please note that both the switching and efficiency characteristics of the module are affected by this diode. Recommended products : RF2001T4S (Rohm), 31DF4 (Nihon Inter), RU30 (Sanken). Inductance : 330µH (Vo=-12V) Rated current : More than 1.3A Please refer to the Output Voltage Settings table to the right. A varistor is required to protect against lightning surges and static electricity. 10kΩ 1/10W Refer to the Output Voltage Settings table to the right. Output Voltage Settings Vo −12V −15V −24V −30V Io 1000mA 800mA 500mA 400mA R2 open 75kΩ 8.2kΩ 1.8kΩ L1 330µH 470µH 1mH 1mH Vo R2 10 VoADJ 9 47kΩ + − Vref=6.9V 12kΩ 36kΩ 11 COM Output block diagram www.rohm.com ©2010 ROHM Co., Ltd. All rights reserved. 1/1 2010.01 - Rev.A Notice Notes No copying or reproduction of this document, in part or in whole, is permitted without the consent of ROHM Co.,Ltd. The content specified herein is subject to change for improvement without notice. The content specified herein is for the purpose of introducing ROHM's products (hereinafter "Products"). If you wish to use any such Product, please be sure to refer to the specifications, which can be obtained from ROHM upon request. Examples of application circuits, circuit constants and any other information contained herein illustrate the standard usage and operations of the Products. The peripheral conditions must be taken into account when designing circuits for mass production. Great care was taken in ensuring the accuracy of the information specified in this document. However, should you incur any damage arising from any inaccuracy or misprint of such information, ROHM shall bear no responsibility for such damage. The technical information specified herein is intended only to show the typical functions of and examples of application circuits for the Products. ROHM does not grant you, explicitly or implicitly, any license to use or exercise intellectual property or other rights held by ROHM and other parties. ROHM shall bear no responsibility whatsoever for any dispute arising from the use of such technical information. The Products specified in this document are intended to be used with general-use electronic equipment or devices (such as audio visual equipment, office-automation equipment, communication devices, electronic appliances and amusement devices). The Products specified in this document are not designed to be radiation tolerant. While ROHM always makes efforts to enhance the quality and reliability of its Products, a Product may fail or malfunction for a variety of reasons. Please be sure to implement in your equipment using the Products safety measures to guard against the possibility of physical injury, fire or any other damage caused in the event of the failure of any Product, such as derating, redundancy, fire control and fail-safe designs. ROHM shall bear no responsibility whatsoever for your use of any Product outside of the prescribed scope or not in accordance with the instruction manual. The Products are not designed or manufactured to be used with any equipment, device or system which requires an extremely high level of reliability the failure or malfunction of which may result in a direct threat to human life or create a risk of human injury (such as a medical instrument, transportation equipment, aerospace machinery, nuclear-reactor controller, fuelcontroller or other safety device). ROHM shall bear no responsibility in any way for use of any of the Products for the above special purposes. If a Product is intended to be used for any such special purpose, please contact a ROHM sales representative before purchasing. If you intend to export or ship overseas any Product or technology specified herein that may be controlled under the Foreign Exchange and the Foreign Trade Law, you will be required to obtain a license or permit under the Law. Thank you for your accessing to ROHM product informations. More detail product informations and catalogs are available, please contact us. ROHM Customer Support System http://www.rohm.com/contact/ www.rohm.com © 2010 ROHM Co., Ltd. All rights reserved. R1010A
BP5013 价格&库存

很抱歉,暂时无法提供与“BP5013”相匹配的价格&库存,您可以联系我们找货

免费人工找货
BP5013
    •  国内价格 香港价格
    • 1+47.196291+5.72026
    • 10+38.6982110+4.69028
    • 50+34.5098150+4.18264
    • 100+33.67699100+4.08170
    • 500+32.78756500+3.97390
    • 1000+31.639391000+3.83474

    库存:0